RESUMEN
Goal-directed fluid therapy (GDFT) is usually recommended in patients undergoing major surgery and is essential in enhanced recovery after surgery (ERAS) protocols. This fluid regimen is usually guided by dynamic hemodynamic parameters and aims to optimize patients' cardiac output to maximize oxygen delivery to their vital organs. While many studies have shown that GDFT benefits patients perioperatively and can decrease postoperative complications, there is no consensus on which dynamic hemodynamic parameters to guide GDFT with. Furthermore, there are many commercialized hemodynamic monitoring systems to measure these dynamic hemodynamic parameters, and each has its pros and cons. This review will discuss and review the commonly used GDFT dynamic hemodynamic parameters and hemodynamic monitoring systems.
Asunto(s)
Objetivos , Complicaciones Posoperatorias , Humanos , Hemodinámica , Fluidoterapia/métodosRESUMEN
We describe the use of a Total Control Introducer (TCI) in combination with video laryngoscopy (VL) to place a left-sided double-lumen endotracheal tube (DLT) in a patient with a history of difficult laryngoscopy undergoing video-assisted thoracoscopic surgery (VATS). VL was used to obtain visualisation of the glottis and a TCI articulating introducer was used to dynamically navigate the airway and access the trachea. A 39 French DLT was subsequently passed over the TCI shaft and into the trachea under indirect visualisation. The TCI shaft was removed and the DLT was gently guided into the left main bronchus. Successful endobronchial intubation was confirmed with capnography, auscultation and fibreoptic bronchoscopy. We propose that the combined use of VL and a TCI can facilitate placement of a DLT in a patient with a known difficult airway who may otherwise be limited to a bronchial blocker placement for lung isolation during VATS.
Asunto(s)
Laringoscopios , Laringoscopía , Bronquios , Broncoscopía , Humanos , Intubación IntratraquealRESUMEN
The newly-discovered tectal longitudinal column (TLC) spans the paramedian region of the mammalian tectum. It has connections with several nuclei of the auditory system. In this report, we provide the first detailed description of the responses of TLC neurons to auditory stimuli, including monaural and binaural tones and amplitude modulated tones. For comparison, responses in the inferior colliculus (IC) were also recorded. Neurons in the TLC were sensitive to similar ranges of frequency as IC neurons, could have comparably low thresholds, and showed primarily excitatory responses to stimulation of the contralateral ear with either phasic or sustained response patterns. Differences of TLC compared to IC neurons included broader frequency tuning, higher average threshold, longer response latencies, little synchronization or rate tuning to amplitude modulation frequency and a smaller degree of inhibition evoked by stimulation of the ipsilateral ear. These features of TLC neurons suggest a role for the TLC in descending auditory pathways.
Asunto(s)
Vías Auditivas/fisiología , Colículos Inferiores/fisiología , Neuronas/metabolismo , Estimulación Acústica , Acústica , Animales , Electrodos , Potenciales Evocados Auditivos/fisiología , Modelos Biológicos , Ratas , Ratas Long-Evans , Ratas Sprague-Dawley , Tiempo de Reacción/fisiologíaRESUMEN
A critical binaural cue important for sound localization and detection of signals in noise is the interaural time difference (ITD), or difference in the time of arrival of sounds at each ear. The ITD can be determined by cross-correlating the sounds at the two ears and finding the ITD where the correlation is maximal. The amount of interaural correlation is affected by properties of spaces and can therefore be used to assess spatial attributes. To examine the neural basis for sensitivity to the overall level of the interaural correlation, we identified subcollicular neurons and neurons in the inferior colliculus (IC) and auditory cortex of unanesthetized rabbits that were sensitive to ITDs and examined their responses as the interaural correlation was varied. Neurons at each brain level could show linear or non-linear responses to changes in interaural correlation. The direction of the non-linearities in most neurons was to increase the slope of the response change for correlations near 1.0. The proportion of neurons with non-linear responses was similar in subcollicular and IC neurons but increased in the auditory cortex. Non-linear response functions to interaural correlation were not related to the type of response as determined by the tuning to ITDs across frequencies. The responses to interaural correlation were also not related to the frequency tuning of the neuron, unlike the responses to ITD, which broadens for neurons tuned to lower frequencies. The neural discriminibility of the ITD using frozen noise in the best neurons was similar to the behavioral acuity in humans at a reference correlation of 1.0. However, for other reference ITDs the neural discriminibility was more linear and generally better than the human discriminibility of the interaural correlation, suggesting that stimulus rather than neural variability is the basis for the decline in human performance at lower levels of interaural correlation.