Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Ann Surg Oncol ; 28(5): 2529-2542, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33221977

RESUMEN

BACKGROUND: Accurate identification of the tumor bed after breast-conserving surgery (BCS) ensures appropriate radiation to the tumor bed while minimizing normal tissue exposure. The BioZorb® three-dimensional (3D) bioabsorbable tissue marker provides a reliable target for radiation therapy (RT) planning and follow-up evaluation while serving as a scaffold to maintain breast contour. METHODS: After informed consent, 818 patients (826 breasts) implanted with the BioZorb® at 14 U.S. sites were enrolled in a national registry. All the patients were prospectively followed with the BioZorb® implant after BCS. The data collected at 3, 6, 12, and 24 months included all demographics, treatment parameters, and provider/patient-assessed cosmesis. RESULTS: The median follow-up period was 18.2 months (range, 0.2-53.4 months). The 30-day breast infection rate was 0.5 % of the patients (n = 4), and re-excision was performed for 8.1 % of the patients (n = 66), whereas 2.6 % of the patients (n = 21) underwent mastectomy. Two patients (0.2 %) had local recurrence. The patient-reported cosmetic outcomes at 6, 12, and 24 months were rated as good-to-excellent by 92.4 %, 90.6 %, and 87.3 % of the patients, respectively and similarly by the surgeons. The radiation oncologists reported planning of target volume (PTV) reduction for 46.2 % of the patients receiving radiation boost, with PTV reduction most commonly estimated at 30 %. CONCLUSIONS: This report describes the first large multicenter study of 818 patients implanted with the BioZorb® tissue marker during BCS. Radiation oncologists found that the device yielded reduced PTVs and that both the patients and the surgeons reported good-to-excellent long-term cosmetic outcomes, with low adverse effects. The BioZorb® 3D tissue marker is a safe adjunct to BCS and may add benefits for both surgeons and radiation oncologists.


Asunto(s)
Neoplasias de la Mama , Implantes Absorbibles , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Humanos , Mastectomía , Mastectomía Segmentaria , Recurrencia Local de Neoplasia/radioterapia , Medición de Resultados Informados por el Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA