Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Intervalo de año de publicación
1.
Biol Sport ; 41(2): 13-18, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38524805

RESUMEN

The objectives of this study were to evaluate the acute effects of the sequence order of drop jumps (DJ) and dynamic stretching (DS) on sprinting performances in competitive athletes and to investigate the relationships between post-activation performance enhancement (PAPE) in sprint performance and lower limb power. Thirteen male jumpers and sprinters participated in this study (19 ± 2 years; 177 ± 7 cm; 71.7 ± 5.6 kg). Through a randomized crossover design, the athletes were exposed to three different conditions after a standardized warm-up: DS+DJ, DJ+DS, and control. Sprinting performance over 40 m was analysed with consideration of initial (0 to 20 m) and final acceleration (20 to 40 m) phases. The effect of intervention was examined by two-way repeated-measures of ANOVA. Pearson's correlation test was used to determine the association between PAPE during sprinting and jump performance. There was no effect of any factor on 40-m sprint performance. Meanwhile, the performance at 20-40 m was higher after the DS+DJ condition when compared to baseline (8.79 ± 0.43 vs. 8.91 ± 0.35 m/s; p = 0.015). However, the initial acceleration was worsened in the DJ+DS condition when compared to baseline (6.26 ± 0.25 vs. 6.22 ± 0.26 m/s; p = 0.002). There was a negative correlation between CMJ height and the improvement in final acceleration (r = -0.741; p = 0.004). The use of DS prior to DJ is an effective strategy to improve performance in the final acceleration phase (20-40 m). The athletes with lower levels of lower limb power benefited the most from this PAPE strategy.

2.
J Sports Sci Med ; 22(2): 254-262, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37293424

RESUMEN

Warm-up protocols with high intensities before continuous running provide potential benefits for middle-distance runners. Nevertheless, the effect of high-intensity warm-ups on long-distance runners remains unclear. The purpose of this study was to verify the effect of a high-intensity warm-up protocol on 5000 m performance in trained runners. Thirteen male runners (34 ± 10 years, 62 ± 6 kg, 62.7 ± 5.5 ml/kg/min) performed two 5000 m time trials, preceded by two different warm-ups. One high-intensity warm up (HIWU: 1x 500 m (70% of the running intensity) + 3x 250 m (100% of the running intensity) and one low-intensity warm up (LIWU: 1x 500 m (70% of the running intensity) + 3x 250 m (70% of the running intensity)), where the running intensities were calculated using the results obtained in the Cooper test. Physiological and metabolic responses, and endurance running performance parameters, were evaluated by the Counter Movement Jump (CMJ), running rating of perceived exertion (RPE), blood lactate concentration (BLa), and performance running. Total time for the 5000 m was lower using HIWU when compared to LIWU (1141.4 ± 110.4 s vs. 1147.8 ± 111.0 s; p = 0.03; Hedges' g = 0.66). The HIWU warm-up led to an improvement in pacing strategy during the time trial. After warm-up protocols, the performance on the CMJ was improved only when applying HIWU (p = 0.008). Post warm-up BLa was significantly higher for HIWU vs. LIWU (3.5 ± 1.0 mmol·L-1 vs. 2.3 ± 1.0 mmol·L-1; p = 0.02), with similar behavior for the RPE (p = 0.002), internal load of the session (p = 0.03). The study showed that a high-intensity warm-up protocol can improve performance in the 5000 m in trained endurance runners.


Asunto(s)
Ejercicio de Calentamiento , Humanos , Masculino , Ácido Láctico , Movimiento
3.
IUBMB Life ; 72(8): 1765-1779, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32449271

RESUMEN

Parkinson's disease (PD) induced by environmental toxins involves a multifactorial cascade of harmful factors, thus motivating the search for therapeutic agents able to act on the greatest number of molecular targets. This study evaluated the efficacy of 50 mg/kg purified anacardic acids (AAs), isolated from cashew nut shell liquid, on multiple steps of oxidative stress and inflammation induced by rotenone in the substantia nigra (SN) and striatum. Adult mice were divided into four groups: Control, rotenone, AAs + rotenone, and AAs alone. Lipoperoxidation, nitric oxide (NO) levels, and reduced glutathione (GSH)/oxidized gluthatione (GSSG) ratio were evaluated. NF-kB-p65, pro-IL-1ß, cleaved IL-1ß, metalloproteinase-9, Tissue Inhibitory Factor-1 (TIMP-1), tyrosine hydroxylase (TH), and glial fibrillary acidic protein (GFAP) levels were assessed by Western blot. In silico studies were also made using the SwissADME web tool. Rotenone increased lipoperoxidation and NO production and reduced TH levels and GSH/GSSG ratio in both SN and striatum. It also enhanced NF-kB-p65, pro, and cleaved IL-1ß, MMP-9, GFAP levels compared to control and AAs groups. The AAs alone reduced pro-IL-1ß in the striatum while they augmented TIMP1 and reduced MMP-9 amounts in both regions. AAs reversed rotenone-induced effects on lipoperoxidation, NO production, and GSH/GSSG ratio, as well as increased TH and attenuated pro-IL-1ß and MMP-9 levels in both regions, NF-kB-p65 in the SN and GFAP in the striatum. Altogether, the in vivo and in silico analysis reinforced multiple and defined molecular targets of AAs, identifying that they are promising neuroprotective drug candidates for PD, acting against oxidative and inflammatory conditions induced by rotenone.


Asunto(s)
Ácidos Anacárdicos/farmacología , Fármacos Neuroprotectores/farmacología , Enfermedad de Parkinson Secundaria/tratamiento farmacológico , Enfermedad de Parkinson/tratamiento farmacológico , Plaguicidas/toxicidad , Ácidos Anacárdicos/química , Ácidos Anacárdicos/aislamiento & purificación , Animales , Simulación por Computador , Cuerpo Estriado/efectos de los fármacos , Cuerpo Estriado/metabolismo , Cuerpo Estriado/patología , Proteína Ácida Fibrilar de la Glía/genética , Glutatión/metabolismo , Disulfuro de Glutatión/metabolismo , Humanos , Interleucina-1beta/genética , Peroxidación de Lípido/efectos de los fármacos , Metaloproteinasa 9 de la Matriz/genética , Ratones , Óxido Nítrico/metabolismo , Estrés Oxidativo/efectos de los fármacos , Enfermedad de Parkinson/etiología , Enfermedad de Parkinson/genética , Enfermedad de Parkinson/patología , Enfermedad de Parkinson Secundaria/inducido químicamente , Enfermedad de Parkinson Secundaria/genética , Enfermedad de Parkinson Secundaria/patología , Inhibidor Tisular de Metaloproteinasa-1/genética , Factor de Transcripción ReIA/genética , Tirosina 3-Monooxigenasa/genética
4.
Gerodontology ; 37(3): 233-243, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32491236

RESUMEN

OBJECTIVES: To examine the McGill Denture Satisfaction Questionnaire (MDSQ) in terms of dimensionality, item reduction and construct validity in a binational sample of complete denture wearers. MATERIALS AND METHODS: We conducted secondary analyses of baseline data from two studies on implant-retained overdentures: a quasi-experimental study in the United States (n = 145) and a randomised trial in Brazil (n = 120). All participants wore upper/lower dentures and responded at baseline to the MDSQ items concerning their original mandibular dentures. A putative model of the MDSQ items resulted in two question subsets: (a) overall satisfaction, retention/stability, aesthetics, cleaning, speech and comfort, plus general chewing ability; (b) mastication of specific foods. Analyses focused on the internal consistency of each subset and possible item reduction, using Cronbach's alpha (Cα), inter-item correlation and exploratory factor analysis (EFA). RESULTS: The 1st subset showed high inter-item correlation for most question combinations and no redundancy (r ≤ .8). An item on cleaning had low correlation, but its removal does not increase internal consistency (Cα ≥ .83). Results were similar for both studies, with EFA showing a single significant factor (namely "overall satisfaction, lower denture") able to explain nearly 54% of the variance. The 2nd subset also shows strong internal consistency (Cα ≥ .95) and inter-item correlation, with a single factor representing 65% of the variation. CONCLUSIONS: This study discloses the reliability and construct validity of the MDSQ for patient-centred evaluation of complete dental prostheses in the edentulous mandible. Findings also support the use of both "overall satisfaction" and "masticatory ability" as summary scores, for improved outcome assessment.


Asunto(s)
Prótesis Dental de Soporte Implantado , Dentadura Completa , Satisfacción Personal , Brasil , Retención de Dentadura , Dentadura Completa Inferior , Prótesis de Recubrimiento , Estética Dental , Análisis Factorial , Humanos , Masticación , Satisfacción del Paciente , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
5.
Clin Oral Implants Res ; 26(6): 639-43, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24547926

RESUMEN

OBJECTIVES: Although three-implant overdentures have often been used in clinical practice, there are few studies to support this approach. Therefore, this study aimed to determine the magnitude of change in ratings of oral health-related quality of life and to assess patients' satisfaction ratings with mandibular three-implant overdentures. MATERIALS AND METHODS: This quasi-experimental study examined oral health-related quality of life and satisfaction with prosthesis in 135 edentate participants (mean age 61.6 ± 7.9 years) who received mandibular three-implant overdentures from 2006 to 2009 in a private practice in Quebec, Canada. Data were collected from individual's dental records and a follow-up survey. The Oral Health Impact Profile (OHIP-20) was used to assess oral health-related quality of life at baseline and at follow-up. Satisfaction with the mandibular prostheses and perception of rocking movements were measured by use of a denture satisfaction questionnaire at follow-up. Descriptive statistics, bivariate and multivariate statistical analyses were used to analyse the data. RESULTS: Individuals who received mandibular three-implant overdentures had statistically significant improvements in all seven domains of the OHIP-20 from pre- to post-treatment (total OHIP change score -25.1 P < 0.001). Pre-treatment OHIP scores and rotational movement explained 58% of the variance in the OHIP's change score (P ≤ 0.05). More than three quarters of the sample population (75.6%) were completely satisfied with their three-implant overdentures, and 81.5% reported having no rocking movement. General satisfaction with the prostheses was not influenced by gender, type of fixture, or type of attachment. CONCLUSIONS: The treatment of edentulism by three-implant overdentures has favourable patient-based outcomes, with negligible perceptions of rotational movement. However, further research is needed to compare the efficacy of this alternative to other treatment modalities, such as the two-implant overdenture.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Diseño de Dentadura , Retención de Dentadura , Dentadura Completa Inferior , Satisfacción del Paciente , Femenino , Humanos , Masculino , Mandíbula/cirugía , Persona de Mediana Edad , Salud Bucal , Calidad de Vida , Quebec , Encuestas y Cuestionarios , Resultado del Tratamiento
6.
Clin Oral Implants Res ; 25(10): 1137-41, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24016256

RESUMEN

OBJECTIVES: The aim of this study was to systematically examine the outcomes of interest of trials in removable prosthodontics and to assess their overall quality. MATERIAL AND METHODS: Electronic databases were searched up to August 2011 and complemented by hand searching for published randomized controlled trials (RCTs) in the field of removable prosthodontics in the six major prosthodontic and implant journals. The primary outcome of RCTs was considered as the outcome of interest of this review, and only manuscripts in which the study's primary outcome was reported in the abstract were included. Outcomes were classified according to the Strength of Recommendation Taxonomy (SORT) classification. The quality of individual reports of RCTs was assessed following the Cochrane Handbook for Systematic Reviews of Interventions (Higgins & Green, www.cochrane-handbook.org). RESULTS: The search retrieved 86 reports of RCTs. Among these publications, 43% reported a patient-oriented primary outcome. Most of the publications did not present a clear description of sequence generation (54%) or allocation concealment (65%). Blinding of participants, clinicians, and outcomes assessors was not applicable or reported in most trials. Handling of withdrawals and losses was adequate in 52% of trials. CONCLUSIONS: Although published RCTs in removable prosthodontics have increased over time, efforts should be made to increase patient-reported outcomes and the methodological quality of these reports. Such improvement will lead to a better body of evidence in the field, thus providing increased support for clinical decision-making.


Asunto(s)
Evaluación de Resultado en la Atención de Salud , Prostodoncia , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto
7.
J Prosthet Dent ; 112(2): 349-56, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24529654

RESUMEN

STATEMENT OF PROBLEM: Contrasting results have been reported regarding the influence of the use of adhesive on biofilm formation. PURPOSE: The purpose of this study was to evaluate the influence of the use of adhesive on the formation of biofilm on the internal surface of complete dentures and the palatal mucosa of denture wearers. MATERIAL AND METHODS: Thirty participants with well-fitting complete dentures were randomly divided according to the experimental design: protocol 1, adhesive use during the first 15 days, followed by no use of adhesive over the next 15 days; protocol 2, no use of adhesives during the first 15 days, followed by adhesive use over the next 15 days. After each period, material from the mucosa and intaglio of the maxillary dentures was collected. Replicate aliquots were plated onto Petri dishes containing selective media for Candida spp, Streptococcus mutans, and a nonselective culture medium. Colony-forming units were expressed as log (CFU+1)/mL. In addition, the internal surfaces of the maxillary and mandibular complete dentures were stained and photographed. From the photographs, the total internal surface and the surface stained with biofilm were quantified (software ImageTool 3.00), and the percentage of the biofilm-covered area (%) on the maxillary and mandibular dentures was calculated and compared with 2-way ANOVA. For the nonselective culture medium, data were compared with the paired-sample t test, and the Wilcoxon signed rank test was performed to compare the colony counts of Candida spp and Streptococcus mutans (α=.05). RESULTS: Similar colony counts were found with or without the use of adhesive for the mucosa and internal surfaces of maxillary dentures, irrespective of the culture medium (P>.05). The area of dentures covered with biofilm was influenced by the use of adhesive (P=.025), regardless of the type of denture (P=.121). CONCLUSIONS: The use of adhesive did not alter the colony counts of microorganisms from the palatal mucosa and maxillary dentures of complete denture wearers during the 15-day period, but it did influence the area covered with biofilm on the internal surfaces of the complete dentures.


Asunto(s)
Adhesivos/química , Biopelículas/crecimiento & desarrollo , Bases para Dentadura/microbiología , Retención de Dentadura , Hueso Paladar/microbiología , Adhesivos/economía , Anciano , Carga Bacteriana , Candida/aislamiento & purificación , Recuento de Colonia Microbiana , Colorantes , Estudios Cruzados , Medios de Cultivo , Dentadura Completa Inferior/microbiología , Dentadura Completa Superior/microbiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rojo Neutro , Fotograbar , Streptococcus mutans/aislamiento & purificación , Propiedades de Superficie , Factores de Tiempo
8.
Int J Prosthodont ; 0(0)2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37824115

RESUMEN

PURPOSE: This scoping review mapped the literature on CAD/CAM (computer-aided design and manufacturing) removable complete and partial dentures regarding patient and clinician-reported outcomes. MATERIALS AND METHODS: We performed an electronic search of the Cochrane Central Register of controlled trials (CENTRAL), MEDLINE (Ovid), EMBASE, SCOPUS, and Web of Science databases (last update: March 2023). All clinical trials or observational studies investigating CAD/CAM removable dentures (conventional or implant-retained) were included. RESULTS: The search yielded 4035 records and led to 58 included studies. Results suggest that CAD/CAM complete and partial dentures, when compared to the conventional ones, can save time and resources while being rated either non-inferior or superior by patients and clinicians in most studies. However, consensus on which workflow offers fewer adjustments and postoperative sessions is still pending. CONCLUSION: The literature suggests that CAD/CAM complete and partial dentures can combine substantial time and cost savings with patient and clinician experiences at least comparable to the conventional prostheses. Given the low evidence level of existing studies, future well-designed randomized trials with large sample size are required to confirm those advantages.

9.
J Dent ; 135: 104592, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37330036

RESUMEN

PURPOSE: The objective of this study was to compare patient-reported outcomes (PROs) of peri­implant soft tissue inflammation and aesthetics around single-tooth implants in the anterior maxillary region with three different implant-abutment interface designs. METHODS: Participants were randomized to one of three different types of implant-abutment interface designs [Conical (CI), flat-to-flat (FI), and Platform Switched (PS)]. Implants and provisional crowns with prefabricated titanium abutments were placed 5 months following extraction and/or ridge augmentation. Permanent ceramic crowns with zirconia abutments were placed after 12 weeks. To assess PROs, appearance and inflammation questionnaires were completed from provisional crown placement to the 3-year follow-up. RESULTS: Tooth appearance at the 3-year follow-up revealed a difference amongst CI, FI and PS implants (p=0.049; Kruskal-Wallis test). PS was rated better than FI (p=0.047) at 1 year for appearance of soft-tissue and satisfaction with colour. There were no differences for self-consciousness, smile and pain/discomfort while eating/hard food items. CONCLUSIONS: Although participants tended to rate the health of mucosa around PS implants as slighty better than the other two implant systems, the differences were minimal and inconsistent. Thus, patient satisfaction in terms self-perceived gingival health and esthetics was high for all 3 systems tested, suggesting that patients are unable to detect mucosal inflammation. CLINICAL SIGNIFICANCE: Patients find it difficult to perceive mucosal inflammation; hence, it is recommended that patients attend implant follow-up visits, even if they do not perceive inflammation. The study suggests that there is a relationship between the PROs and the clinical outcomes of tested implants.


Asunto(s)
Implantes Dentales de Diente Único , Diente , Humanos , Estética Dental , Implantación Dental Endoósea/efectos adversos , Implantación Dental Endoósea/métodos , Coronas , Circonio , Inflamación , Pilares Dentales
10.
Gerodontology ; 29(2): e474-80, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21696442

RESUMEN

BACKGROUND: Knowledge of benefits caused by a treatment on quality of life is very relevant. Despite the wide use and acceptance of soft denture liners, it is necessary to evaluate the patient's response about the use of these materials with regard to improvement in oral health related quality of life (OHRQoL). OBJECTIVES: The aim of this study was to evaluate the influence of denture relining in the OHRQoL of edentulous patients. MATERIALS AND METHODS: Thirty-two complete denture wearers had their lower dentures relined with a silicone-based material (Mucopren soft, Kettenbach, Germany) according to chairside procedures. OHRQoL was assessed before and after 3 months of relining by means of OHIP-EDENT, and the median scores were compared by Wilcoxon test (p ≤ 0.05). RESULTS: After 3 months of relining, participants reported significant improvement of their OHRQoL (p ≤ 0.01). CONCLUSION: Denture relining with a soft liner may have a positive impact on the perceived oral health of edentulous patients.


Asunto(s)
Materiales Dentales/química , Alineadores Dentales/psicología , Rebasado de Dentaduras/psicología , Boca Edéntula/psicología , Salud Bucal , Calidad de Vida , Siliconas/química , Adulto , Anciano , Ansiedad/psicología , Retención de Dentadura/psicología , Dentadura Completa Inferior/psicología , Escolaridad , Empleo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Masticación/fisiología , Persona de Mediana Edad , Ajuste Oclusal , Dolor/psicología , Satisfacción del Paciente , Estrés Psicológico/psicología
11.
J Prosthodont ; 21(1): 2-6, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21972847

RESUMEN

PURPOSE: Adequate denture hygiene can prevent and treat infection in edentulous patients, who are frequently elderly and have difficulty brushing their teeth. This study evaluated the efficacy of complete denture biofilm removal using a chlorhexidine solution in two concentrations: 0.12% and 2.0%. MATERIALS AND METHODS: Sixty complete denture wearers participated in a trial for 21 days after receiving brushing instructions. They were distributed into three groups, according to the tested solution and regimen (n = 20): (G1) Control (daily overnight soaking in water); (G2) daily immersion at home in 0.12% chlorhexidine for 20 minutes after dinner; and (G3) a single immersion in 2.0% chlorhexidine for 5 minutes at the end of the experimental period, performed by a professional. Biofilm coverage area (%) was quantified on the internal surface of maxillary dentures at baseline and after 21 days. Afterward, the differences between initial and posttreatment results were compared by means of the Kruskal-Wallis test (α= 0.05). RESULTS: Median values for biofilm coverage area after treatment were: (G1) 36.0%; (G2) 5.3%; and (G3) 1.4%. Differences were significant (KW = 35.25; p < 0.001), although G2 and G3 presented similar efficacy in terms of biofilm removal. CONCLUSIONS: Both chlorhexidine-based treatments had a similar ability to remove denture biofilm. Immersion in 0.12% or 2.0% chlorhexidine solutions can be used as an auxiliary method for cleaning complete dentures.


Asunto(s)
Antiinfecciosos Locales/farmacología , Biopelículas/efectos de los fármacos , Clorhexidina/farmacología , Limpiadores de Dentadura/farmacología , Anciano , Anciano de 80 o más Años , Antiinfecciosos Locales/administración & dosificación , Clorhexidina/administración & dosificación , Dentadura Completa , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadísticas no Paramétricas
12.
J Dent ; 127: 104357, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36351489

RESUMEN

OBJECTIVES: To evaluate the benefits of implant therapy for patients with diabetes, we compared (i) healthy, (ii) well controlled T2DM and (iii) poorly controlled T2DM patients, in terms of oral health-related quality of life (OHRQoL) and satisfaction with mandibular 2-implant overdentures over 12 months following restoration. MATERIALS AND METHODS: This single-center, prospective, cohort study recruited 165 edentulous adults (HbA1c<12%) to receive two endosseous implants in the anterior mandible to support mandibular overdentures. Participants were enrolled as having T2DM or not, with T2DM participants divided according to HbA1c into well-controlled (<8.1%) and poorly controlled (≥ 8.1%) groups. Participants provided responses to the OHIP-20 (OHRQoL) and the McGill Denture Satisfaction Questionnaire, before implant therapy and 6 and 12 months after overdenture insertion using Locator attachments. HbA1c was measured at the same time points. The effect of groups and time was verified using generalized estimating equations (α=0.025). RESULTS: At 12 months, 137 participants provided responses. The two diabetes groups showed improvements in OHRQoL to the same extent as the non-diabetic control group at both 6 and 12 months. Patient satisfaction showed similar improvements with no between-group differences and similar increases identified at 6 and 12 months. HbA1c was not affected by time or groups. CONCLUSIONS: Dental implant therapy provided significant improvements in patient-perceived benefits of mandibular two-implant overdentures for T2DM individuals, which are similar to those found for healthy edentulous individuals. Importantly, those benefits extend to those individuals with poorly controlled glycaemia. The addition of 2-implant supported mandibular overdentures did not affect glycaemic status over 12 months following insertion. CLINICAL SIGNIFICANCE: As risks for implant therapy relative to glycaemic status are better understood, this study documents that implant therapy may offer important benefits in QoL for T2DM patients independent of glycaemic status.


Asunto(s)
Implantes Dentales , Diabetes Mellitus Tipo 2 , Arcada Edéntula , Boca Edéntula , Humanos , Prótesis de Recubrimiento , Calidad de Vida , Estudios Prospectivos , Satisfacción Personal , Estudios de Cohortes , Prótesis Dental de Soporte Implantado , Satisfacción del Paciente , Mandíbula , Retención de Dentadura
13.
Lasers Med Sci ; 26(3): 359-67, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21086009

RESUMEN

The purpose of this study was to evaluate the effect of a single application of antimicrobial photodynamic therapy (aPDT) on microbiological profile and cytokine pattern in dogs. Periodontal disease was induced by placing 3.0 silk ligatures around the mandibular pre-molars bilaterally during 8 weeks. The dogs were randomly treated with aPDT using a dye/laser system, scaling and root planning (SRP), or with the association of treatments (SRP + aPDT). Plaque samples were collected at baseline, 1, 3, and 4 weeks, and the mean counts of 40 species were determined using DNA-DNA hybridization. Gingival biopsies were removed and the expression of tumor necrosis factor alpha (TNF-α), receptor activator of NF-kB ligand (RANKL), osteoprotegerin (OPG), matrix metalloproteinase (MMP-1), interleukin (IL) 6, IL-10 and total bacterial load by analysis of 16 S rRNA gene were evaluated through real-time PCR. The results shows that the levels of the majority of the species were reduced 1 week post-therapy for all treatments, however, an increase in counts of Prevotella intermedia (p = 0.00), Prevotella. nigrescens (p = 0.00) and Tannerella forsythia (p = 0.00) was observed for aPDT and SRP + aPDT. After 4 weeks, a regrowth of Porphyromonas gingivalis (p = 0.00) and Treponema denticola (p = 0.00), was observed for all treatments. Also, a strikingly reduction of counts on counts of Aggregatibacter actinomycetemcomitans was observed for the aPDT (p = 0.00). For the cytokine pattern, the results were similar for all treatments, and a reduction in the expression of cytokines and bacterial load was observed throughout the study. Our results suggest that SRP, aPDT in a single application, and SRP + aPDT affects different bacterial species and have similar effects on the expression of cytokines evaluated during the treatment of ligature-induced periodontitis.


Asunto(s)
Periodontitis/tratamiento farmacológico , Periodontitis/microbiología , Fotoquimioterapia , Animales , Bacterias/aislamiento & purificación , Carga Bacteriana , Terapia Combinada , Citocinas/genética , Raspado Dental , Modelos Animales de Enfermedad , Perros , Expresión Génica , Masculino , Mandíbula , Periodontitis/inmunología , Periodontitis/terapia , ARN Mensajero/genética , ARN Mensajero/metabolismo , Aplanamiento de la Raíz
14.
Artículo en Inglés | MEDLINE | ID: mdl-33923769

RESUMEN

The purpose of this study was to investigate the multivariate profile of different types of Brazilian runners and to identify the discriminant pattern of the distinct types of runners, as a runners' ability to self-classify well. The sample comprised 1235 Brazilian runners of both sexes (492 women; 743 men), with a mean age of 37.94 ± 9.46 years. Individual characteristics were obtained through an online questionnaire: Sex, age, body height (m) and body mass (kg), socioeconomic status, and training information (i.e., self-classification, practice time, practice motivation, running pace, frequency and training volume/week). Multivariate analysis of variance was conducted by sex and the discriminant analysis was used to identify which among running pace, practice time, body mass index and volume/training could differentiate groups such as "professional athletes", "amateur athletes" and "recreational athletes". For both sexes, running pace was the variable that better discriminated the groups, followed by BMI and volume/week. The practice time is not a good indicator to differentiate runner's types. In both sexes, semi-professional runners were those that better self-classify themselves, with amateur runners presenting the highest classification error. This information can be used to guide the long-term training, athlete's selection programs, and to identify the strengths and weaknesses of athletes.


Asunto(s)
Carrera , Adulto , Antropometría , Brasil , Análisis Discriminante , Femenino , Humanos , Masculino , Persona de Mediana Edad , Motivación
15.
Artículo en Inglés | MEDLINE | ID: mdl-33922940

RESUMEN

The objective of this study was to analyze the acute effect of hyperoxia during the maximal treadmill test (MTT) of runners. Participants included 10 female street runners who performed the MTT under two different conditions: hyperoxia (HYPX), inhaling oxygen (60% O2) every 3 min; and normoxia (NORM), without additional oxygen inhalation. Both groups performed the MTT with increases in the slope of the run every 3 min until voluntary exhaustion. The variables of lactate concentration, the onset of blood lactate accumulation (OBLA), peripheral oxygen saturation (SpO2), heart rate (HR), and Borg scale were evaluated. It was verified after the comparison (HYPX vs. NORM) that stage 3 (p = 0.012, Cohen's d = 1.76) and stage 4 (p < 0.001; Cohen's d = 5.69) showed a reduction in lactate under the HYPX condition. OBLA under the HYPX condition was identified at a later stage than NORM. There were no differences in Borg scale, SpO2, and HR between the different conditions. It was concluded that the HYPX condition contributed to a reduction in lactate concentration and delayed OBLA in runners.


Asunto(s)
Hiperoxia , Carrera , Prueba de Esfuerzo , Femenino , Humanos , Ácido Láctico , Consumo de Oxígeno
16.
Gerodontology ; 27(3): 193-8, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19545320

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the effect of the domestic use of a disclosing agent for denture hygiene. MATERIALS AND METHODS: Completely edentulous participants wearing maxillary dentures were randomly assigned to one of the three intervention groups: (1) Follow-up only (control; n = 12); (2) Oral and denture hygiene instructions (n = 10); (3) Instructions associated with the home use of a disclosing agent (1% neutral red; n = 10). Biofilm coverage area (%) over internal and external surfaces of the maxillary denture was assessed at baseline and after 14 and 90 days. Data were evaluated by generalised estimating equations based on score tests (alpha = 0.05). RESULTS: The participants presented low changes for areas of biofilm coverage (14 days (%): internal: GI = 1.4 +/- 0.9; GII = 1.5 +/- 1.3; GIII = -0.4 +/- 0.9; external: GI = 1.4 +/- 1.5; GII = 1.5 +/- 1.4; GIII = -0.4 +/- 0.9; 90 days (%): internal: GI = 2.0 +/- 0.9; GII = 2.2 +/- 1.4; GIII = 0.3 +/- 1.0; external: GI = 2.1 +/- 1.4; GII = 2.2 +/- 1.5; GIII = 0.3 +/- 0.9). Changes were similar for the three groups (p = 0.293) and were not influenced by the test time (p = 0.218). CONCLUSION: It can be concluded that the home use of a disclosing agent for denture hygiene does not improve the removal of the biofilm, particularly for patients with adequate oral hygiene habits.


Asunto(s)
Colorantes , Dentadura Completa Superior , Higiene Bucal , Anciano , Biopelículas , Placa Dental/microbiología , Placa Dental/terapia , Dentífricos/uso terapéutico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Rojo Neutro , Educación del Paciente como Asunto , Método Simple Ciego , Propiedades de Superficie , Cepillado Dental/instrumentación , Resultado del Tratamiento
17.
J Dent ; 98: 103356, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32380132

RESUMEN

OBJECTIVES: To evaluate the effectiveness of CCDs produced by two impression procedures for the mandibular ridge, in patients with severe mandibular atrophy. METHODS: Fifty-two completely edentulous patients with severely resorbed mandibles were randomly allocated into two groups according to the impression procedure of the mandibular ridge: SI - single impression (stock tray and irreversible hydrocolloid); TI - two-step impression (custom tray, border molding with compound, and polyether). Assessments of oral health related quality of life (OHRQoL, primary outcome) and denture satisfaction were performed by using validated questionnaires. Denture quality was evaluated by means of functional tests. RESULTS: Regardless of the technique, participants reported better OHRQoL (P < 0.001) in both follow-up periods (3 and 6 months after denture delivery), and groups resulted in similar OHIP-EDENT scores in its different domains (P > 0.05). Between-group differences were insignificant for general satisfaction (3 months, P = 0.699, 6 months, P = 0.392), as well as for aspects such as esthetics, comfort, mastication, speech, and prosthesis retention (P > 0.05). Overall clinical quality of the CCDs (P = 0.383) was similar between-group, as well as in specific aspects - interocclusal distance, occlusion, articulation, retention of the maxillary denture, and stability of both maxillary and mandibular dentures (P > 0.05). CONCLUSIONS: Mandibular CCDs based on a single impression technique showed quality levels comparable to those generated by a two-step impression, both from the patient and clinician perspective. CLINICAL SIGNIFICANCE: A simplified impression technique which eliminates the secondary impression can provide CCDs of good clinical quality, which influences the OHRQoL, and satisfaction in the same extent they would by a two-step procedure, even for patients with severely reabsorbed mandibular ridges. (ClinicalTrials.gov: NCT02339194).


Asunto(s)
Retención de Dentadura , Calidad de Vida , Dentadura Completa , Humanos , Mandíbula , Satisfacción del Paciente , Percepción
18.
J Dent ; 99: 103357, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32437857

RESUMEN

OBJECTIVES: To compare one- vs two-step impression procedures for the provision of conventional complete dentures (CCDs) for edentulous individuals with severe mandibular resorption, in terms of (1) masticatory performance and ability; (2) satisfaction with mandibular CCDs; and (3) post-delivery adjustments. METHODS: Fifty-two patients requiring maxillary + mandibular CCDs were randomly divided into two parallel arms according to the impression method of the mandibular ridge: (SI) single impression with stock trays (irreversible hydrocolloid); (TI) two-step impression in custom trays, with border molding (impression compound) followed by the impression itself (polyether). Mastication performance was evaluated by a colorimetric test, whereas patients answered questions on masticatory ability and satisfaction with mandibular CCDs (100-mm visual analogue scale). The number of post-delivery sessions for adjustments were also quantified. Outcomes were assessed at 3 and 6 months after delivery. RESULTS: The masticatory performance was similar for both groups, regardless of time (3 months, P = 0.62; 6 months, P = 0.61). No significant difference was found for patient-reported (P > 0.05), i.e. masticatory ability (general ease of chewing and quality of grinding food; ability to chew specific foods), general satisfaction with the mandibular CCD (general satisfaction, comfort, aesthetics, ability to speak and to perform correct cleaning, retention and stability). Both methods resulted in a similar number of post-delivery adjustment sessions [SI: 3.8 (1.7); TI: 3.2 (1.4); P = 0.09]. CONCLUSIONS: Compared to a traditional approach, CCDs obtained from a single impression achieve similar masticatory performance/ability and patient satisfaction, even in patients with severely reabsorbed mandibular ridge. Both methods demand the same amount of post-delivery adjustment. CLINICAL SIGNIFICANCE: A simplified impression technique which eliminates the secondary impression can provide CCDs of good clinical quality, which influences the OHRQoL, and satisfaction in the same extent they would by a two-step procedure, even for patients with severely reabsorbed mandibular ridges (ClinicalTrials.gov: NCT02339194).


Asunto(s)
Masticación , Boca Edéntula , Retención de Dentadura , Dentadura Completa , Humanos , Mandíbula , Satisfacción del Paciente
19.
Artículo en Inglés | MEDLINE | ID: mdl-32708894

RESUMEN

The aim of this study is to evaluate the effect of ingesting ibuprofen on post-workout recovery of muscle damage, body temperature and muscle power indicators in Paralympic powerlifting athletes. The study was carried out with eight Paralympic powerlifting athletes (aged 27.0 ± 5.3 years and 79.9 ± 25.5 kg of body mass) competing at the national level, with a minimum training experience of 12 months, who all submitted to two experimental conditions: Ibuprofen (2 × 00 mg) and control. The maximal isometric force of the upper limbs and rate of force development, thermography, and serum biochemical analyzes of creatine kinase, lactate dehydrogenase, aspartate aminotransferase and alanine aminotransferase were measured before, after, 24 h after and 48 h after the intervention. Maximal isometric force only decreased in the placebo condition, which increased back to baseline levels, while no substantial decline in baseline force was seen in the ibuprofen condition, although no effect for exercise condition was detected. After the exercise, the rate of force development decreased significantly for both conditions and did not exceed baseline levels again after 48 h. Muscle temperature decreased significantly at 48-h post-exercise in the placebo condition, when compared with the previous day of measurement; and deltoid muscle temperature at 48-h post-exercise was higher with the ibuprofen condition. Although the results indicate some positive effects of ibuprofen use, they do not enable a clear statement regarding its positive effects on muscle function and muscle damage. Ibuprofen seems to have caused a delay in the anti-inflammatory response following exercise.


Asunto(s)
Antiinflamatorios no Esteroideos , Temperatura Corporal , Ibuprofeno , Músculo Esquelético , Levantamiento de Peso , Adulto , Antiinflamatorios no Esteroideos/farmacología , Atletas , Temperatura Corporal/efectos de los fármacos , Creatina Quinasa , Ejercicio Físico , Humanos , Ibuprofeno/farmacología , Músculo Esquelético/efectos de los fármacos , Adulto Joven
20.
J Prosthodont ; 18(5): 427-31, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19486455

RESUMEN

PURPOSE: The aim of this study was to evaluate the effect of three denture hygiene methods against different microbial biofilms formed on acrylic resin specimens. MATERIALS AND METHODS: The set (sterile stainless steel basket and specimens) was contaminated (37 degrees C for 48 hours) by a microbial inoculum with 10(6) colony-forming units (CFU)/ml (standard strains: Staphylococcus aureus, Streptococcus mutans, Escherichia coli, Candida albicans, Pseudomonas aeruginosa, and Enterococcus faecalis; field strains: S. mutans, C. albicans, C. glabrata, and C. tropicalis). After inoculation, specimens were cleansed by the following methods: (1) chemical: immersion in an alkaline peroxide solution (Bonyplus tablets) for 5 minutes; (2) mechanical: brushing with a dentifrice for removable prostheses (Dentu Creme) for 20 seconds; and (3) a combination of chemical and mechanical methods. Specimens were applied onto a Petri plate with appropriate culture medium for 10 minutes. Afterward, the specimens were removed and the plates incubated at 37 degrees C for 48 hours. RESULTS: Chemical, mechanical, and combination methods showed no significant difference in the reduction of CFU for S. aureus, S. mutans (ATCC and field strain), and P. aeruginosa. Mechanical and combination methods were similar and more effective than the chemical method for E. faecalis, C. albicans (ATCC and field strain), and C. glabrata. The combination method was better than the chemical method for E. coli and C. tropicalis, and the mechanical method showed intermediate results. CONCLUSION: The three denture hygiene methods showed different effects depending on the type of microbial biofilms formed on acrylic base resin specimens.


Asunto(s)
Biopelículas/efectos de los fármacos , Limpiadores de Dentadura , Dentadura Completa/microbiología , Higiene Bucal/métodos , Cepillado Dental/métodos , Resinas Acrílicas , Recuento de Colonia Microbiana , Bases para Dentadura/microbiología , Desinfección/métodos , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA