Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Am Coll Cardiol ; 20(3): 552-8, 1992 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-1512332

RESUMEN

OBJECTIVES: This study compares 24-h parasympathetic activity in aerobically trained and untrained healthy young men. BACKGROUND: Higher values of parasympathetic nervous system activity are associated with a low mortality rate in patients after myocardial infarction, but it remains uncertain what therapeutic interventions can be used to increase parasympathetic activity. Although it is thought that exercise training can increase parasympathetic activity, studies have reported conflicting results, perhaps because this variable was measured for only brief intervals and usually inferred from changes in reflex responses induced by pharmacologic blockade. METHODS: Parasympathetic activity was assessed noninvasively from 24-h ECG recordings by calculating high frequency (0.15 to 0.40 Hz) beat to beat heart period variability in eight endurance-trained men (maximal oxygen consumption greater than or equal to 55 ml/kg per min) and eight age-matched (mean = 29 yr) untrained men (maximal oxygen consumption less than or equal to 40 ml/kg per min). The data were analyzed separately for sleeping hours when parasympathetic activity is dominant and also for waking hours. RESULTS: The geometric mean of high frequency power was greater in the trained than in the untrained men during the day (852 vs. 177 ms2, p less than 0.005), during the night (1,874 vs. 427 ms2, p less than 0.005) and over the entire 24 h (1,165 vs. 276 ms2, p less than 0.001). CONCLUSIONS: Parasympathetic activity is substantially greater in trained than in untrained men, and this effect is present during both waking and sleeping hours. These data suggest that exercise training may increase parasympathetic activity over the entire day and may therefore prove to be a useful adjunct or alternative to drug therapy in lessening the derangements of autonomic balance found in many cardiovascular diseases.


Asunto(s)
Ejercicio Físico/fisiología , Corazón/fisiología , Sistema Nervioso Parasimpático/fisiología , Resistencia Física/fisiología , Adulto , Ritmo Circadiano/fisiología , Electrocardiografía Ambulatoria , Humanos , Masculino , Aptitud Física/fisiología , Sueño/fisiología
2.
J Am Coll Cardiol ; 21(3): 729-36, 1993 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-8436755

RESUMEN

OBJECTIVES: To determine whether spectral measures of heart period (RR) variability predict death when measured late after infarction, we studied patients in the Cardiac Arrhythmia Pilot Study (CAPS) who survived for 1 year and had a 24-h electrocardiographic (ECG) recording made after the CAPS drug was washed out. BACKGROUND: Four components of the heart period power spectrum--ultra low frequency (< 0.0033 Hz), very low frequency (0.0033 to < 0.04 Hz), low frequency (0.04 to < 0.15 Hz) and high frequency power (0.15 to < 0.40 Hz)--plus total power (1.157 x 10(-5) to < 0.40 Hz) and the ratio of low to high frequency power predict mortality when measured < 30 days after myocardial infarction. However, these variables increase to steady state values by 3 months after infarction and the prognostic significance of recovery values is unknown. METHODS: The 24-h power spectral density was computed from ECG recordings made 1 year after infarction using fast Fourier transforms and the six measures listed were calculated. The values were dichotomized at cut points that maximized the association with mortality. RESULTS: Each measure of RR variability had a strong and significant univariate association with mortality; the relative risks for these variables ranged from 2.5 to 5.6. After adjustment for age, New York Heart Association functional class, rales in the coronary care unit, left ventricular ejection fraction and ventricular arrhythmias, some measures of heart period variability still had a strong and significant independent association with all-cause mortality. CONCLUSIONS: Spectral measures of heart period variability, measured late after infarction, predict death.


Asunto(s)
Electrocardiografía Ambulatoria/métodos , Infarto del Miocardio/mortalidad , Procesamiento de Señales Asistido por Computador , Femenino , Estudios de Seguimiento , Análisis de Fourier , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/fisiopatología , Valor Predictivo de las Pruebas , Pronóstico , Factores de Riesgo , Análisis de Supervivencia , Factores de Tiempo
3.
J Am Coll Cardiol ; 23(3): 733-40, 1994 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-7509355

RESUMEN

OBJECTIVES: This study was designed to test the hypothesis that antiarrhythmic drugs that decrease RR variability will predict all-cause mortality during follow-up after myocardial infarction. BACKGROUND: RR variability, a noninvasive indicator of autonomic nervous system activity, predicts death after acute myocardial infarction independently of other risk predictors and changes substantially in response to some drugs. A previous study in patients with chronic heart disease and frequent ventricular premature complexes reported that flecainide decreased vagal modulation of RR intervals but amiodarone did not. The investigators of that study speculated that changes in RR variability during antiarrhythmic drug therapy predict an increased mortality rate during long-term drug treatment. To explore this hypothesis further, we compared the effects of encainide and flecainide, which increase long-term mortality substantially, on RR variability with the effects of placebo and moricizine, which have no significant effect on mortality during long-term treatment of unsustained ventricular arrhythmias after myocardial infarction. METHODS: The 24-h power spectral density was computed from the baseline electrocardiographic recordings and drug evaluation tapes, and six frequency domain measures of RR variability were calculated: ultra-low frequency (< 0.0033 Hz), very low frequency (0.0033 to < 0.04 Hz), low frequency (0.04 to < 0.15 Hz) and high frequency power (0.15 to < 0.40 Hz), plus total power (< 0.40 Hz) and the ratio of low to high frequency power. Changes in power spectral measures were related to drug treatment and to mortality. RESULTS: In the placebo group, values for RR interval and RR variability increased because of recovery from the effects of acute myocardial infarction. Contrasting placebo treatment with all three active antiarrhythmic drug treatments taken together showed that of all the measures of RR variability, only NN50, pNN50 and low frequency power changed significantly during drug treatment (Bonferroni adjusted p value < 0.025); these variables all decreased during drug therapy. Contrasting encainide and flecainide with moricizine, we found that the encainide and flecainide groups taken together showed a larger decrease in dLF than moricizine, but the difference was of borderline significance (Bonferroni adjusted p value < 0.08). Survival was significantly worse in the groups treated with encainide and flecainide than in the groups treated with placebo or moricizine (relative risk > 2.0, adjusted p < 0.05). The antiarrhythmic drug-induced change in measures of RR variability was not a significant predictor of all-cause mortality during a year of follow-up after myocardial infarction. CONCLUSIONS: Encainide, flecainide and moricizine all caused a decrease in RR variability in patients studied approximately 1 month after acute myocardial infarction. Encainide and flecainide caused a significant increase in mortality rates; placebo and moricizine did not. Baseline measurements of RR variability also predicted all-cause mortality after myocardial infarction. The decrease in RR variability produced by the three antiarrhythmic drugs did not predict mortality during follow-up.


Asunto(s)
Antiarrítmicos/uso terapéutico , Complejos Cardíacos Prematuros/tratamiento farmacológico , Electrocardiografía Ambulatoria/métodos , Sistema de Conducción Cardíaco/efectos de los fármacos , Infarto del Miocardio/mortalidad , Procesamiento de Señales Asistido por Computador , Encainida/uso terapéutico , Femenino , Flecainida/uso terapéutico , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Moricizina/uso terapéutico , Factores de Riesgo
4.
J Am Coll Cardiol ; 18(7): 1643-9, 1991 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-1960309

RESUMEN

Four components of the heart period power spectrum--ultra low frequency (less than 0.0033 Hz), very low frequency (0.0033 to less than 0.04 Hz), low frequency (0.04 to less than 0.15 Hz) and high frequency power (0.15 to 0.40 Hz)--plus total power (1.157 x 10(-5) to 0.4 Hz for a 24-h electrocardiographic [ECG] recording) all predict mortality after myocardial infarction. To determine the time course and magnitude of recovery for these measures of heart period variability, 68 patients in the Cardiac Arrhythmia Pilot Study (CAPS) placebo group who had 24-h ECG recordings at baseline, 3, 6 and 12 months after myocardial infarction were studied. The 24-h power spectral density was computed with use of fast Fourier transforms and divided into the four components listed previously. The values for the five frequency domain measures of heart period variability in the CAPS patients were similar to those found in 715 patients who participated in the Multicenter Post Infarction Program (MPIP), indicating that the CAPS sample is generally representative of postinfarction patients with respect to these measures. The values for the five measures were one third to one half of those found in 95 normal persons of similar age and gender. There was a substantial increase in all measures of heart period variability between the baseline 24-h ECG recording and the 3-month recording (p less than 0.001). Between 3 and 12 months, the values were quite stable for the group as a whole, as well as for individual patients (intraclass correlation coefficients greater than or equal to 0.66).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrocardiografía Ambulatoria/normas , Electrofisiología , Frecuencia Cardíaca , Infarto del Miocardio/mortalidad , Anciano , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Femenino , Estudios de Seguimiento , Análisis de Fourier , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/fisiopatología , Proyectos Piloto , Valor Predictivo de las Pruebas , Pronóstico , Factores de Tiempo
5.
J Am Coll Cardiol ; 17(2): 480-4, 1991 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-1991906

RESUMEN

Several time and frequency domain measures of heart period variability are reduced 1 to 2 weeks after myocardial infarction, and a reduced standard deviation of normal RR intervals over a 24 h period (SDNN) is associated with increased mortality. The predictive accuracy of heart period variability may be reduced by drugs used to treat patients after myocardial infarction. Accordingly, a randomized, three period, placebo-controlled, crossover (Latin square) design was used to determine the effect of atenolol and diltiazem on time and frequency measures of heart period variability calculated from 24 h continuous electrocardiographic recordings during treatment with atenolol, diltiazem and placebo in 18 normal volunteers. During atenolol treatment, the 24 h average normal RR (NN) interval increased 24% (p less than 0.001). The three measures of tonic vagal activity were significantly increased (p less than 0.001) during atenolol treatment: percent of successive normal RR intervals greater than 50 ms = 69%, root mean square successive difference of normal RR intervals = 61% and high frequency power in the heart period power spectrum = 84%. Low frequency power also increased 45% (p less than 0.01), indicating that this variable also is an indicator of tonic vagal activity over 24 h. Diltiazem had no significant effect on the 24 h average NN interval or on any measure of heart period variability. The decreased mortality rate after myocardial infarction associated with beta-adrenergic blocker but not calcium channel blocker therapy may be attributed in part to an increase in vagal tone caused by beta-blockers.


Asunto(s)
Atenolol/farmacología , Diltiazem/farmacología , Corazón/efectos de los fármacos , Adulto , Electrocardiografía Ambulatoria , Femenino , Corazón/inervación , Humanos , Masculino , Contracción Miocárdica/efectos de los fármacos , Infarto del Miocardio/tratamiento farmacológico , Sistema Nervioso Parasimpático/efectos de los fármacos , Sistema Nervioso Simpático/efectos de los fármacos
6.
J Am Coll Cardiol ; 14(6): 1511-8, 1989 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-2809012

RESUMEN

In animals, baroreflex sensitivity is inversely related to the likelihood of ventricular fibrillation during myocardial ischemia. After myocardial infarction in human patients, reduced baroreflex sensitivity is associated with increased mortality. A reduced standard deviation of normal RR intervals over a 24 h period is also associated with reduced survival after myocardial infarction. Therefore, 32 normotensive men who had survived their first myocardial infarction were studied to define the relation between baroreflex sensitivity assessed with phenylephrine injection and three Holter electrocardiographic measures of tonic vagal activity: the percent of successive normal RR intervals greater than 50 ms, the root mean square successive difference of normal RR intervals and the power in the high frequency energy of the normal RR interval power spectrum. Correlations among the Holter measures of heart period variability were greater than or equal to 0.94, indicating that these measures are so strongly correlated that any one of them can be used to represent the others. Baroreflex sensitivity showed weaker correlations with the three Holter variables (0.57 to 0.63), indicating that the Holter measures did not accurately predict baroreflex sensitivity. Baroreflex sensitivity showed a stronger correlation with the three Holter variables during the night than during the day. Baroreflex sensitivity and tonic vagal activity reflected by Holter variables were reduced more in patients with inferior myocardial infarction than in those with anterior infarction. The relative utility of baroreflex sensitivity and Holter measures of tonic vagal activity in predicting sudden cardiac death after myocardial infarction needs to be evaluated in a large prospective study.


Asunto(s)
Ritmo Circadiano/fisiología , Frecuencia Cardíaca , Infarto del Miocardio/fisiopatología , Presorreceptores/fisiología , Electrocardiografía Ambulatoria , Humanos , Masculino , Persona de Mediana Edad , Fenilefrina , Pronóstico , Volumen Sistólico
7.
Am J Cardiol ; 69(8): 718-23, 1992 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-1546643

RESUMEN

To determine the reproducibility of frequency domain measures of heart period variability in patients with previous myocardial infarction, 2 random samples of 40 patients each (1 from the Cardiac Arrhythmia Pilot Study [CAPS] [unsustained ventricular arrhythmias], and 1 from the Electrophysiologic Studies Versus Electrocardiographic Monitoring [ESVEM] [sustained ventricular arrhythmias] trial) were studied. For each patient, two 24-hour continuous electrocardiographic recordings were analyzed, and the average normal RR interval, total power and 4 components of total power were calculated. Group means and standard deviations for each sample were virtually identical for the pairs of 24-hour recordings. Furthermore, measurements for individual patients were stable from day to day, as measured by the intraclass correlation coefficients and the standard errors of measurement. Reproducibility of heart period variability measurements is excellent in patients with previous myocardial infarction and ventricular arrhythmias, and is comparable to the high stability previously found in a small group of normal subjects. The stability of measures of heart period variability facilitates distinguishing real changes due to progression or regression of cardiac disease or to drug effects from apparent changes due to random variation.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Frecuencia Cardíaca , Infarto del Miocardio/fisiopatología , Adulto , Anciano , Distribución de Chi-Cuadrado , Electrocardiografía Ambulatoria , Electrofisiología , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Factores de Tiempo
8.
Am J Cardiol ; 61(4): 208-15, 1988 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-3341195

RESUMEN

A high degree of heart rate (HR) variability is found in persons with normal hearts, whereas low HR variability can be found in patients with severe coronary artery disease, congestive heart failure and diabetic neuropathy. Two weeks after acute myocardial infarction, low HR variability predicted reduced long-term survival even after adjusting for clinical risk indicators, left ventricular ejection fraction, HR and ventricular arrhythmias. The present study elucidated the causes of differences in HR and HR variability between patients with low and high HR variability. In a matched-pair study, 10 patients with low HR variability (24-hour standard deviation of N-N intervals less than 50 ms) were randomly selected. For each of these 10 patients, a control patient with high HR variability (24-hour standard deviation of N-N intervals greater than or equal to 100 ms), matched for age, left ventricular ejection fraction and rales in the coronary care unit was selected. Patients who were taking either digitalis or beta-adrenergic blocking drugs were excluded. Analysis of 24-hour electrocardiograms showed that for the low HR variability group compared with the high: (1) the daytime and nighttime average HR was faster; (2) the difference between daytime and nighttime HR was less; (3) the proportion of differences greater than 50 ms between successive N-N intervals was smaller; and (4) the number of HR "spikes" per day (increase in HR greater than or equal to 10 beats/min, lasting from 3 to 15 minutes) was less.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Frecuencia Cardíaca , Infarto del Miocardio/fisiopatología , Adulto , Anciano , Ritmo Circadiano , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Volumen Sistólico
9.
Am J Cardiol ; 80(8): 1101-4, 1997 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-9352991

RESUMEN

To determine the effect of beta blockade on parasympathetic nervous system activity, we assessed RR variability during 24-hour Holter monitoring in 10 patients with congestive heart failure before and after 3 to 4 months of treatment with the beta blocker carvedilol. High-frequency power increased from 26 to 64 ms2, root-mean-square of successive differences in RR interval increased from 14.3 to 23.7 ms2, and percentage of absolute differences >50 ms between successive normal RR intervals increased from 0.8% to 4.7%, all p <0.01, indicating a substantial increase in parasympathetic modulation of RR intervals.


Asunto(s)
Antagonistas Adrenérgicos beta/farmacología , Carbazoles/farmacología , Electrocardiografía/efectos de los fármacos , Insuficiencia Cardíaca/tratamiento farmacológico , Sistema Nervioso Parasimpático/efectos de los fármacos , Propanolaminas/farmacología , Antagonistas Adrenérgicos beta/administración & dosificación , Antagonistas Adrenérgicos beta/uso terapéutico , Adulto , Anciano , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Carbazoles/administración & dosificación , Carbazoles/uso terapéutico , Carvedilol , Enfermedad Crónica , Digoxina/uso terapéutico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Propanolaminas/administración & dosificación , Propanolaminas/uso terapéutico
10.
Am J Cardiol ; 69(9): 891-8, 1992 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-1550018

RESUMEN

Seven hundred fifteen participants from a multicenter natural history study of acute myocardial infarction were studied (1) to determine the correlations among time and frequency domain measures of heart period variability, (2) to determine the correlations between the measures of heart period variability and previously established post-infarction risk predictors, and (3) to determine the predictive value of time domain measures of heart period variability for death during follow-up after acute myocardial infarction. Twenty-four hour electrocardiographic recordings obtained 11 +/- 3 days after acute myocardial infarction were analyzed and 11 measures of heart period variability were computed. Each of 4 bands in the heart period power spectrum had 1 or 2 corresponding variables in the time domain that correlated with it so strongly (r greater than or equal to 0.90) that the variables were essentially equivalent: ultra low frequency power with SDNN* and SDANN index,* very low frequency power and low-frequency power with SDNN index,* and high-frequency power with r-MSSD* and pNN50.* As expected from theoretical considerations, SDNN and the square root of total power were almost perfectly correlated. Correlations between the time and frequency domain measures of heart period variability and previously identified postinfarction risk predictors, e.g., left ventricular ejection fraction and ventricular arrhythmias, are remarkably weak. Time domain measures of heart period variability, especially those that measure ultra low or low-frequency power, are strongly and independently associated with death during follow-up. * Defined in Table II.


Asunto(s)
Frecuencia Cardíaca , Infarto del Miocardio/fisiopatología , Electrocardiografía Ambulatoria , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Factores de Riesgo , Análisis de Supervivencia
11.
Am J Cardiol ; 75(16): 1145-50, 1995 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-7762502

RESUMEN

The objective of this study was to characterize the autonomic effects of 2 interventions, head-up tilt and isoproterenol infusion, which alter autonomic balance by different mechanisms but produce the same RR intervals. We compared the effect of head-up tilt with the effect of isoproterenol on autonomic balance as measured by power spectral analysis of RR variability. Fifteen normal subjects had baseline measurements and then underwent head-up tilt. After return to baseline supine values, isoproterenol was infused at a rate of 1 microgram/min (low-dose isoproterenol), which was then increased to 2.1 +/- 0.5 microgram/min (high-dose isoproterenol). All subjects underwent a second tilt during high-dose isoproterenol, and 9 subjects completed this second tilt study. During the experiment, normal RR intervals were recorded and 5-minute segments were used to calculate power spectra. High-frequency (HF) power (0.15 to 0.40 Hz) was used as a measure of vagal activity. The effects of head-up tilt were compared with the effects of low-dose isoproterenol. Despite nearly identical mean RR intervals (784 ms with tilt vs 792 ms with low-dose isoproterenol, p = NS), there was significantly (p < 0.05) less HF power during head-up tilt in the drug-free state (172 ms2) than during low-dose isoproterenol in the supine position (307 ms2). A second head-up tilt was performed during the infusion of high-dose isoproterenol. During high-dose isoproterenol, tilt caused a decrease in RR intervals (from 573 to 491 ms; p < 0.01) and a decrease in HF power (from 68 to 28 ms2; p < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Electrocardiografía , Corazón/fisiología , Isoproterenol/farmacología , Postura , Nervio Vago/fisiología , Adulto , Femenino , Análisis de Fourier , Corazón/efectos de los fármacos , Humanos , Infusiones Intravenosas , Isoproterenol/administración & dosificación , Masculino , Posición Supina , Pruebas de Mesa Inclinada
12.
Am J Cardiol ; 72(1): 95-9, 1993 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-8517437

RESUMEN

To test the effects of digitalis and angiotensin-converting enzyme inhibition on the RR interval variability in an electrocardiogram, 20 normal subjects were given digoxin 0.25 mg, enalapril 10 mg, and placebo twice daily in a randomized, double-blind, crossover study. Continuous 24-hour electrocardiographic recordings obtained on day 5 of each treatment were analyzed and several time domain and power spectral measures of heart period variability were calculated. Digoxin markedly increased (up to 51%) indexes of vagal modulation of heart period without changing mean RR interval. Enalapril did not change any measure of heart period variability despite a modest hypotensive effect. To determine the effect of each treatment on the response to orthostatic stress, 10 subjects also underwent 15 minutes of 60 degrees head-up tilt; power spectra were calculated for 15 minutes at 0 degree and at 60 degrees of tilt. Neither active treatment affected the response to head-up tilt.


Asunto(s)
Digoxina/farmacología , Enalapril/farmacología , Frecuencia Cardíaca/efectos de los fármacos , Adulto , Sistema Nervioso Autónomo/efectos de los fármacos , Sistema Nervioso Autónomo/fisiología , Ritmo Circadiano , Método Doble Ciego , Electrocardiografía Ambulatoria/efectos de los fármacos , Femenino , Cabeza , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Postura/fisiología
13.
Med Sci Sports Exerc ; 29(6): 812-7, 1997 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9219210

RESUMEN

The association between increasing age and decreasing vagal modulation is well known. However, the importance of fitness as a determinant of the decline in vagal modulation with age is not established. To test the hypothesis that decreasing vagal modulation is largely a function of declining fitness rather than increasing age, we studied a sample of healthy volunteers with a wide range of fitness levels, but a narrow age range. We assessed fitness by measuring the maximal oxygen uptake (VO2max) achieved during incremental bicycle exercise. Vagal modulation was assessed by calculating high frequency power (0.15-0.40 Hz) of the RR variability power spectrum from 24-h ECG recordings. We studied 37 healthy volunteers who were 22-44 yr old. In our sample, VO2max ranged from 25 to 70 mL.min-1.kg-1 (mean of 45 +/- 13). Age was not significantly related to high frequency power, but VO2max was highly correlated with high frequency power (r = 0.74, P = 0.0001), indicating that physical fitness is strongly associated with vagal modulation. Thus, the decline in vagal modulation often attributed to increasing age may, instead, be the result of a decline in fitness.


Asunto(s)
Ejercicio Físico/fisiología , Consumo de Oxígeno , Aptitud Física , Nervio Vago/fisiología , Adulto , Electrocardiografía Ambulatoria , Prueba de Esfuerzo , Femenino , Humanos , Masculino
14.
Biol Psychol ; 37(2): 89-99, 1994 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8003592

RESUMEN

Although many laboratory studies have demonstrated changes in cardiac autonomic control during psychological stress, few have attempted to demonstrate this effect in ambulatory subjects. To address this issue, 24-h electrocardiographic recordings of 33 healthy subjects were analyzed for RR interval and heart period variability (HPV) responses associated with periodic diary entries measuring physical position, negative effect, and time of day. A total of 362 diary entries were made during the 24-h sessions, each in response to a device which signaled on an average of once per hour. HPV was analyzed in the frequency domain, yielding estimates of spectral power in low (LF) and high (HF) frequency bands, as well as the LF/HF ratio. Because of the high correlations of the measures of negative affect (alpha = 0.91), they were combined to create a single index of stress. Multivariate analysis was used to assess the effect of individual subject differences, physical position, and stress on RR interval and HPV. Results revealed significant effects of individual differences, stress, and physical position on RR interval, with increases in stress associated with decreases in RR interval as expected. HF power was significantly lower and the LF/HF ratio significantly higher in the standing compared with the sitting position. Psychological stress was significantly associated with an increase in the LF/HF ratio, suggesting increases in the relative predominance of sympathetic nervous system activity during stressful periods of the day. Overall, these findings suggest that in ambulatory normal subjects, cardiac autonomic control varies throughout the day as a function of self-reported stress.


Asunto(s)
Nivel de Alerta/fisiología , Sistema Nervioso Autónomo/fisiología , Ritmo Circadiano/fisiología , Frecuencia Cardíaca/fisiología , Estrés Psicológico/complicaciones , Adulto , Enfermedad Coronaria/fisiopatología , Electrocardiografía Ambulatoria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Procesamiento de Señales Asistido por Computador , Estrés Psicológico/fisiopatología
15.
Biol Psychol ; 38(2-3): 133-42, 1994 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7873698

RESUMEN

Heart period variability (HPV) measured from 24 h ECG recordings predicts mortality following myocardial infarction and may be a measure of cardiovascular health in the general population. Since epidemiologic evaluation of healthy people will require alternatives less intensive than 24 h recording, we investigated the relationship between HPV derived from 24 h and 5 min recordings, using two approaches for obtaining RR intervals. Template-matching (TM) algorithms were applied to 24 h ECG recordings from 41 normal subjects (mean age 35.7 +/- 13 years). Five min of ECG data during this 24 h period also were collected by an on-line microcomputer-based system for peak detection (PD) analysis. Intraclass correlations comparing the TM and PD approaches on the 5 min period were .80 or greater for all measures of HPV. Pearson correlation coefficients between the 5 min (TM) estimates and 24 h data and 5 min (PD) estimates and 24 h data exceeded .60 and .55, respectively, for all but one variable, with all p values < .05. Thus, in healthy adults, TM and PD approaches to HPV estimation from short segments of ECG data are highly consistent and the correlations between HPV obtained from brief intervals and 24 h measures were substantial, suggesting that assessment of HPV as a screening measure of cardiac autonomic control in healthy adults may be feasible.


Asunto(s)
Causas de Muerte , Electrocardiografía Ambulatoria/estadística & datos numéricos , Electrocardiografía/estadística & datos numéricos , Frecuencia Cardíaca/fisiología , Infarto del Miocardio/mortalidad , Adulto , Algoritmos , Nivel de Alerta/fisiología , Sistema Nervioso Autónomo/fisiopatología , Femenino , Análisis de Fourier , Trasplante de Corazón/fisiología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/fisiopatología , Valores de Referencia , Reproducibilidad de los Resultados , Factores de Riesgo , Procesamiento de Señales Asistido por Computador
20.
Am J Physiol ; 274(5): H1761-6, 1998 05.
Artículo en Inglés | MEDLINE | ID: mdl-9612388

RESUMEN

High-frequency power, measured from power spectral analysis of R-R variability, reflects vagal modulation of the sinus node. Unexpectedly, a recent study reported a decrease in high-frequency power during the infusion of phenylephrine despite a prolongation of R-R intervals, indicating an increase in vagal activity. To better define the limitations of high-frequency power to quantify vagal modulation, we measured high-frequency power during the infusion of phenylephrine (0.4, 0.8, and 1.2 micrograms.kg-1.min-1) into 10 normal subjects. We found increasing doses of phenylephrine produced progressive increases in systolic blood pressure from 118 +/- 4 to 129 +/- 5 mmHg (P < 0.005), R-R intervals from 881 +/- 44 to 1,274 +/- 69 ms (P < 0.0001), and the logarithm of high-frequency power from 5.83 +/- 0.22 to 7.73 +/- 0.24 ln(ms2) (P < 0.0001). The conclusion was high-frequency power increases with increasing doses of phenylephrine. These data strongly support the ability of high-frequency power to detect an increase in vagal modulation during baroreceptor activation from an increase in systolic blood pressure with the infusion of phenylephrine.


Asunto(s)
Frecuencia Cardíaca/fisiología , Corazón/inervación , Corazón/fisiología , Sistema Nervioso Parasimpático/fisiología , Fenilefrina/administración & dosificación , Simpatomiméticos/farmacología , Nervio Vago/fisiología , Adulto , Femenino , Humanos , Masculino , Sistema Nervioso Parasimpático/efectos de los fármacos , Nervio Vago/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA