Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anesthesiology ; 140(2): 207-219, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37889844

RESUMEN

BACKGROUND: Remimazolam exhibits sedative properties by binding to γ-aminobutyric acid type A receptors. Remimazolam is administered as a bolus dose or continuous infusion, but has not been studied using target-controlled infusion (TCI). The study quantified the relationship between the remimazolam concentration, Modified Observer's Assessment of Alertness and Sedation (MOAAS) score, and bispectral index (BIS) using TCI. METHODS: The authors performed a three-period, crossover, dose-ranging clinical trial in 24 healthy volunteers using age and sex stratification. Data collected in the first period, where remimazolam was administered alone using a step-up and step-down TCI protocol, were used for this analysis. Remimazolam concentrations, MOAAS scores, and BIS values were collected at each step at steady state. Data were analyzed using nonlinear mixed-effects modeling methodology. RESULTS: The relationship between remimazolam, BIS, and MOAAS differed between step-up and step-down infusions at similar remimazolam target concentrations. Tolerance, driven by remimazolam or CNS7054, significantly improved overall model fit (P < 0.01) for both BIS and MOAAS models. After 30 min of repeated bolus dosing, mimicking the regimen in the label for procedural sedation, the BIS and probability of MOAAS 2/3 were predicted to be 54 (95% prediction interval, 44 to 67) and 2% (95% prediction interval, 0 to 32%) versus 58 (95% prediction interval, 48 to 70) and 8% (95% prediction interval, 0 to 36%) in a model without and with tolerance, respectively. After 60 min of continuous infusion, mimicking the regimen in the label for general anesthesia, the BIS and probability of MOAAS 0 were predicted to be 40 (95% prediction interval, 33 to 50) and 87% (95% prediction interval, 18 to 100%) versus 50 (95% prediction interval, 41 to 60) and 59% (95% prediction interval, 6 to 99%) in a model without and with tolerance, respectively. CONCLUSIONS: In this study, it was shown that remimazolam-induced sedation is prone to tolerance development, which is potentially mediated by the CNS7054 concentration. The clinical consequences are, however, limited in situations where remimazolam is titrated to effect.


Asunto(s)
Benzodiazepinas , Hipnóticos y Sedantes , Humanos , Anestesia General , Benzodiazepinas/farmacología , Voluntarios Sanos , Hipnóticos y Sedantes/farmacología , Infusiones Intravenosas
2.
Anaesthesia ; 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38606765

RESUMEN

BACKGROUND: Recommendations exist that aim to mitigate the substantial ecological impact of anaesthesia. One option is to use anaesthetic gas capturing technology at anaesthesia workstation exhausts to harvest and recycle volatile agents. However, the efficiency of such technology is mainly unverified in vivo. METHODS: The efficiency of CONTRAfluran™ in capturing sevoflurane from an anaesthesia workstation exhaust (when set to minimal flow and end-tidal control mode) was evaluated in 70 adult patients scheduled for general or bariatric laparoscopic surgery. The weight of the sevoflurane vaporiser and CONTRAfluran canister was measured before and after each case, to calculate total sevoflurane consumption and retention. Retention was measured after the minimal flow maintenance phase and after the high flow washout phase. The total retention efficiency was the fraction of all consumed sevoflurane captured by the CONTRAfluran canister. The primary objective was to examine the retention efficiency of CONTRAfluran in a clinical surgical setting, where all feasible strategies to minimise sevoflurane consumption and optimise the efficacy of CONTRAfluran were utilised. The secondary objective was to analyse the correlation between mass transfer and the duration of the case. RESULTS: Mean (SD) volume of sevoflurane captured using CONTRAfluran was 4.82 (1.41) ml, representing 45% (95%CI 42-48%) of all sevoflurane administered. The highest amount of retention was found during the washout phase. Retention efficiency did not correlate with the duration of the case. CONCLUSIONS: Over half of the sevoflurane administered was not captured by the CONTRAfluran canister when minimal flow techniques were used, likely due to residual accumulation of sevoflurane in the patient after tracheal extubation or, to a lesser extent, due to ventilation system leakage. However, as every prevented emission is commendable, CONTRAfluran may be a potentially valuable tool for reducing the environmental footprint of sevoflurane-based anaesthesia.

3.
J Clin Monit Comput ; 38(2): 519-529, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38112878

RESUMEN

This single blinded randomized controlled trial aims to assess whether the application of a Bayesian-adjusted CePROP (effect-site of propofol) advisory tool leads towards a more stringent control of the cerebral drug effect during anaesthesia, using qCON as control variable. 100 patients scheduled for elective surgery were included and randomized into a control or intervention group (1:1 ratio). In the intervention group the advisory screen was made available to the clinician, whereas it was blinded in the control group. The settings of the target-controlled infusion pumps could be adjusted at any time by the clinician. Cerebral drug effect was quantified using processed EEG (CONOX monitor, Fresenius Kabi, Bad Homburg, Germany). The time of qCON between the desired range (35-55) during anaesthesia maintenance was defined as our primary end point. Induction parameters and recovery times were considered secondary end points and coefficient of variance of qCON and CePROP was calculated in order to survey the extent of control towards the mean of the population. The desired range of qCON between 35 and 55 was maintained in 84% vs. 90% (p = 0.15) of the case time in the control versus intervention group, respectively. Secondary endpoints showed similar results in both groups. The coefficient of variation for CePROP was higher in the intervention group. The application of the Bayesian-based CePROP advisory system in this trial did not result in a different time of qCON between 35 and 55 (84 [21] vs. 90 [18] percent of the case time). Significant differences between groups were hard to establish, most likely due to a very high performance level in the control group. More extensive control efforts were found in the intervention group. We believe that this advisory tool could be a useful educational tool for novices to titrate propofol effect-site concentrations.


Asunto(s)
Propofol , Humanos , Propofol/farmacología , Anestésicos Intravenosos/farmacología , Teorema de Bayes , Anestesia Intravenosa , Alemania , Electroencefalografía
4.
Int J Mol Sci ; 25(4)2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38397090

RESUMEN

Volatile anesthetics have been shown in different studies to reduce ischemia reperfusion injury (IRI). Ex vivo lung perfusion (EVLP) facilitates graft evaluation, extends preservation time and potentially enables injury repair and improvement of lung quality. We hypothesized that ventilating lungs with sevoflurane during EVLP would reduce lung injury and improve lung function. We performed a pilot study to test this hypothesis in a slaughterhouse sheep DCD model. Lungs were harvested, flushed and stored on ice for 3 h, after which EVLP was performed for 4 h. Lungs were ventilated with either an FiO2 of 0.4 (EVLP, n = 5) or FiO2 of 0.4 plus sevoflurane at a 2% end-tidal concentration (Cet) (S-EVLP, n = 5). Perfusate, tissue samples and functional measurements were collected and analyzed. A steady state of the target Cet sevoflurane was reached with measurable concentrations in perfusate. Lungs in the S-EVLP group showed significantly better dynamic lung compliance than those in the EVLP group (p = 0.003). Oxygenation capacity was not different in treated lungs for delta partial oxygen pressure (PO2; +3.8 (-4.9/11.1) vs. -11.7 (-12.0/-3.2) kPa, p = 0.151), but there was a trend of a better PO2/FiO2 ratio (p = 0.054). Perfusate ASAT levels in S-EVLP were significantly reduced compared to the control group (198.1 ± 93.66 vs. 223.9 ± 105.7 IU/L, p = 0.02). We conclude that ventilating lungs with sevoflurane during EVLP is feasible and could be useful to improve graft function.


Asunto(s)
Trasplante de Pulmón , Animales , Ovinos , Sevoflurano/farmacología , Estudios de Factibilidad , Proyectos Piloto , Preservación de Órganos , Pulmón , Perfusión
5.
Br J Anaesth ; 130(1): 7-8, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36470746

RESUMEN

The British Journal of Anaesthesia organisation is a registered charity comprised of two interlinked missions: provision of impactful publications and funding the generation and dissemination of research to the wider anaesthetic community. This centenary editorial highlights our charitable activity that covers funding of research infrastructure, meeting support and funding of a diverse portfolio of international research grants.


Asunto(s)
Anestesia , Anestesiología , Investigación Biomédica , Humanos , Edición , Organizaciones de Beneficencia
6.
Br J Anaesth ; 131(2): 222-233, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37355412

RESUMEN

BACKGROUND: Propofol and remifentanil are frequently combined for the induction and maintenance of general anaesthesia. Both propofol and remifentanil cause vasodilation and potentially reduce arterial BP. We aimed to develop a mechanism-based model that characterises the haemodynamic interactions between remifentanil and propofol. METHODS: Data from two clinical trials in healthy volunteers were analysed using remifentanil-alone, propofol-alone, and combination groups. We evaluated remifentanil effects on haemodynamics using a previously developed mechanism-based haemodynamic model of propofol. The interaction between propofol and remifentanil was explored using the principles of the general pharmacodynamic interaction (GPDI) model. RESULTS: Remifentanil alone increased the dissipation rate of total peripheral resistance by 50% at 3.0 ng ml-1. Additionally, the dissipation rates of HR and stroke volume were attenuated by 4.8% and 4.9% per 1 ng ml-1 increase in remifentanil concentration, respectively. The maximal effect of propofol alone in decreasing the production rate of total peripheral resistance was 78%, which decreased to 32% when combined with remifentanil 4 ng ml-1. The effects of remifentanil on HR and stroke volume were attenuated by propofol with maximum decreases of 11.9% and 21.2%, respectively. Goodness-of-fit plots and prediction-corrected visual predictive check plots showed good predictive performance of the models. CONCLUSIONS: The structure of the previous mechanism-based haemodynamic model for propofol was able to describe the effects of remifentanil alone on haemodynamic variables. The GPDI model provided a good framework for characterising the pharmacodynamic interaction between remifentanil and propofol on haemodynamic properties. CLINICAL TRIAL REGISTRATION: NCT02043938; NCT03143972.


Asunto(s)
Propofol , Humanos , Anestésicos Intravenosos/farmacología , Voluntarios Sanos , Hemodinámica , Piperidinas/farmacología , Propofol/farmacología , Remifentanilo/farmacología
7.
Sensors (Basel) ; 23(15)2023 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-37571519

RESUMEN

Incorporating technology into healthcare processes is necessary to ensure the availability of high-quality care in the future. Wearable sensors are an example of such technology that could decrease workload, enable early detection of patient deterioration, and support clinical decision making by healthcare professionals. These sensors unlock continuous monitoring of vital signs, such as heart rate, respiration rate, blood oxygen saturation, temperature, and physical activity. However, broad and successful application of wearable sensors on the surgical ward is currently lacking. This may be related to the complexity, especially when it comes to replacing manual measurements by healthcare professionals. This report provides practical guidance to support peers before starting with the clinical application of wearable sensors in the surgical ward. For this purpose, the Non-Adoption, Abandonment, Scale-up, Spread, and Sustainability (NASSS) framework of technology adoption and innovations in healthcare organizations is used, combining existing literature and our own experience in this field over the past years. Specifically, the relevant topics are discussed per domain, and key lessons are subsequently summarized.


Asunto(s)
Dispositivos Electrónicos Vestibles , Humanos , Signos Vitales/fisiología , Frecuencia Cardíaca , Frecuencia Respiratoria , Hospitales
8.
Int J Mol Sci ; 24(6)2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36982720

RESUMEN

Early non-invasive detection and prediction of graft function after kidney transplantation is essential since interventions might prevent further deterioration. The aim of this study was to analyze the dynamics and predictive value of four urinary biomarkers: kidney injury molecule-1 (KIM-1), heart-type fatty acid binding protein (H-FABP), N-acetyl-ß-D-glucosaminidase (NAG), and neutrophil gelatinase-associated lipocalin (NGAL) in a living donor kidney transplantation (LDKT) cohort. Biomarkers were measured up to 9 days after the transplantation of 57 recipients participating in the VAPOR-1 trial. Dynamics of KIM-1, NAG, NGAL, and H-FABP significantly changed over the course of 9 days after transplantation. KIM-1 at day 1 and NAG at day 2 after transplantation were significant predictors for the estimated glomerular filtration rate (eGFR) at various timepoints after transplantation with a positive estimate (p < 0.05), whereas NGAL and NAG at day 1 after transplantation were negative significant predictors (p < 0.05). Multivariable analysis models for eGFR outcome improved after the addition of these biomarker levels. Several donor, recipient and transplantation factors significantly affected the baseline of urinary biomarkers. In conclusion, urinary biomarkers are of added value for the prediction of graft outcome, but influencing factors such as the timing of measurement and transplantation factors need to be considered.


Asunto(s)
Lesión Renal Aguda , Trasplante de Riñón , Humanos , Lipocalina 2 , Trasplante de Riñón/efectos adversos , Proteína 3 de Unión a Ácidos Grasos , Donadores Vivos , Riñón , Lesión Renal Aguda/diagnóstico , Biomarcadores
9.
Int J Mol Sci ; 24(17)2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37686384

RESUMEN

During ischemia and reperfusion injury (IRI), mitochondria may release mitochondrial DNA (mtDNA). mtDNA can serve as a propagator of further injury but in specific settings has anti-inflammatory capacities as well. Therefore, the aim of this study was to study the perioperative dynamics of plasma mtDNA during living donor kidney transplantation (LDKT) and its potential as a marker of graft outcome. Fifty-six donor-recipient couples from the Volatile Anesthetic Protection of Renal Transplants-1 (VAPOR-1) trial were included. Systemic venous, systemic arterial, and renal venous samples were taken at multiple timepoints during and after LDKT. Levels of mtDNA genes changed over time and between vascular compartments. Several donor, recipient, and transplantation-related variables significantly explained the course of mtDNA genes over time. mtDNA genes predicted 1-month and 24-month estimated glomerular filtration rate (eGFR) and acute rejection episodes in the two-year follow-up period. To conclude, mtDNA is released in plasma during the process of LDKT, either from the kidney or from the whole body in response to transplantation. While circulating mtDNA levels positively and negatively predict post-transplantation outcomes, the exact mechanisms and difference between mtDNA genes are not yet understood and need further exploration.


Asunto(s)
ADN Mitocondrial , Trasplante de Riñón , Humanos , ADN Mitocondrial/genética , Riñón , Cinética , Donadores Vivos , Mitocondrias/genética
10.
Curr Opin Anaesthesiol ; 36(5): 602-607, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37678184

RESUMEN

PURPOSE OF REVIEW: There are various pharmacokinetic-dynamic models available, which describe the time course of drug concentration and effect and which can be incorporated into target-controlled infusion (TCI) systems. For anesthesia and sedation, most of these models are derived from narrow patient populations, which restricts applicability for the overall population, including (small) children, elderly, and obese patients. This forces clinicians to select specific models for specific populations. RECENT FINDINGS: Recently, general purpose models have been developed for propofol and remifentanil using data from multiple studies and broad, diverse patient groups. General-purpose models might reduce the risks associated with extrapolation, incorrect usage, and unfamiliarity with a specific TCI-model, as they offer less restrictive boundaries (i.e., the patient "doesn't fit in the selected model") compared with the earlier, simpler models. Extrapolation of a model can lead to delayed recovery or inadequate anesthesia. If multiple models for the same drug are implemented in the pump, it is possible to select the wrong model for that specific case; this can be overcome with one general purpose model implemented in the pump. SUMMARY: This article examines the usability of these general-purpose models in relation to the more traditional models.


Asunto(s)
Anestésicos Intravenosos , Propofol , Niño , Anciano , Humanos , Anestésicos Intravenosos/efectos adversos , Anestesia Intravenosa/efectos adversos , Anestesia General , Propofol/efectos adversos , Remifentanilo/efectos adversos
11.
Anesthesiology ; 136(5): 843-860, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35180291

RESUMEN

Nonsteroidal anti-inflammatory drugs are among the most commonly administered drugs in the perioperative period due to their prominent role in pain management. However, they potentially have perioperative consequences due to immune-modulating effects through the inhibition of prostanoid synthesis, thereby affecting the levels of various cytokines. These effects may have a direct impact on the postoperative outcome of patients since the immune system aims to restore homeostasis and plays an indispensable role in regeneration and repair. By affecting the immune response, consequences can be expected on various organ systems. This narrative review aims to highlight these potential immune system-related consequences, which include systemic inflammatory response syndrome, acute respiratory distress syndrome, immediate and persistent postoperative pain, effects on oncological and neurologic outcome, and wound, anastomotic, and bone healing.


Asunto(s)
Antiinflamatorios no Esteroideos , Dolor Postoperatorio , Antiinflamatorios no Esteroideos/farmacología , Antiinflamatorios no Esteroideos/uso terapéutico , Citocinas , Humanos , Inmunidad , Dolor Postoperatorio/tratamiento farmacológico , Periodo Perioperatorio
12.
Anesthesiology ; 136(2): 279-292, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34851425

RESUMEN

BACKGROUND: Numerous pharmacokinetic models have been published aiming at more accurate and safer dosing of dexmedetomidine. The vast majority of the developed models underpredict the measured plasma concentrations with respect to the target concentration, especially at plasma concentrations higher than those used in the original studies. The aim of this article was to develop a dexmedetomidine pharmacokinetic model in healthy adults emphasizing linear versus nonlinear kinetics. METHODS: The data of two previously published clinical trials with stepwise increasing dexmedetomidine target-controlled infusion were pooled to build a pharmacokinetic model using the NONMEM software package (ICON Development Solutions, USA). Data from 48 healthy subjects, included in a stratified manner, were utilized to build the model. RESULTS: A three-compartment mamillary model with nonlinear elimination from the central compartment was superior to a model assuming linear pharmacokinetics. Covariates included in the final model were age, sex, and total body weight. Cardiac output did not explain between-subject or within-subject variability in dexmedetomidine clearance. The results of a simulation study based on the final model showed that at concentrations up to 2 ng · ml-1, the predicted dexmedetomidine plasma concentrations were similar between the currently available Hannivoort model assuming linear pharmacokinetics and the nonlinear model developed in this study. At higher simulated plasma concentrations, exposure increased nonlinearly with target concentration due to the decreasing dexmedetomidine clearance with increasing plasma concentrations. Simulations also show that currently approved dosing regimens in the intensive care unit may potentially lead to higher-than-expected dexmedetomidine plasma concentrations. CONCLUSIONS: This study developed a nonlinear three-compartment pharmacokinetic model that accurately described dexmedetomidine plasma concentrations. Dexmedetomidine may be safely administered up to target-controlled infusion targets under 2 ng · ml-1 using the Hannivoort model, which assumed linear pharmacokinetics. Consideration should be taken during long-term administration and during an initial loading dose when following the dosing strategies of the current guidelines.


Asunto(s)
Dexmedetomidina/administración & dosificación , Dexmedetomidina/sangre , Sistemas de Liberación de Medicamentos/métodos , Tasa de Depuración Metabólica/efectos de los fármacos , Modelos Biológicos , Dinámicas no Lineales , Adolescente , Adulto , Anciano , Analgésicos no Narcóticos/administración & dosificación , Analgésicos no Narcóticos/sangre , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Infusiones Intravenosas , Modelos Lineales , Masculino , Tasa de Depuración Metabólica/fisiología , Persona de Mediana Edad , Adulto Joven
13.
Br J Anaesth ; 128(5): 806-816, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35249706

RESUMEN

BACKGROUND: The adverse haemodynamic effects of the intravenous anaesthetic propofol are well known, yet few empirical models have explored the dose-response relationship. Evidence suggests that hypotension during general anaesthesia is associated with postoperative mortality. We developed a mechanism-based model that quantitatively characterises the magnitude of propofol-induced haemodynamic effects during general anaesthesia. METHODS: Mean arterial pressure (MAP), heart rate (HR) and pulse pressure (PP) measurements were available from 36 healthy volunteers who received propofol in a step-up and step-down fashion by target-controlled infusion using the Schnider pharmacokinetic model. A mechanistic pharmacodynamic model was explored based on the Snelder model. To benchmark the performance of this model, we developed empirical models for MAP, HR, and PP. RESULTS: The mechanistic model consisted of three turnover equations representing total peripheral resistance (TPR), stroke volume (SV), and HR. Propofol-induced changes were implemented by Emax models on the zero-order production rates of the turnover equations for TPR and SV. The estimated 50% effective concentrations for propofol-induced changes in TPR and SV were 2.96 and 0.34 µg ml-1, respectively. The goodness-of-fit for the mechanism-based model was indistinguishable from the empirical models. Simulations showed that predictions from the mechanism-based model were similar to previously published MAP and HR observations. CONCLUSIONS: We developed a mechanism-based pharmacodynamic model for propofol-induced changes in MAP, TPR, SV, and HR as a potential approach for predicting haemodynamic alterations. CLINICAL TRIAL REGISTRATION: NCT02043938.


Asunto(s)
Propofol , Anestesia General , Anestésicos Intravenosos/farmacocinética , Voluntarios Sanos , Hemodinámica , Humanos , Propofol/efectos adversos
14.
Br J Anaesth ; 128(6): 959-970, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35361490

RESUMEN

BACKGROUND: The advisory system SmartPilot® View (Drägerwerk AG, Lübeck, Germany) provides real-time, demographically adjusted pharmacodynamic information throughout anaesthesia, including time course of effect-site concentrations of administered drugs and a measure of potency of the combined drug effect termed the "'Noxious Stimulation Response Index' (NSRI). This dual-centre, prospective, observational study assesses whether the availability of SmartPilot® View alters the behaviour of anaesthetic drug titration of anaesthetists and improves the Anaesthesia Quality Score (AQS; percentage of time spent with MAP 60-80 mm Hg and Bispectral Index [BIS] 40-60 [blinded]). METHODS: We recruited 493 patients scheduled for elective surgery in two university centres. A control group (CONTROL; n=170) was enrolled to observe drug titration in current practice. Thereafter, an intervention group was enrolled, for which SmartPilot® View was made available to optimise drug titration (SPV; n=188). The AQS, haemodynamic and hypnotic effects, recovery times, pain scores, and other parameters were compared between groups. RESULTS: There were 358 patients eligible for analysis. Anaesthesia quality score was similar between CONTROL and SPV (median AQS [Q1-Q3]) 25.3% [7.4-41.5%] and 22.2% [8.0-44.4%], respectively; P=0.898). Compared with CONTROL, SPV patients had less severe hypotension and hypertension, less BIS <40, faster tracheal extubation, and lower early postoperative pain scores. CONCLUSIONS: Adding SmartPilot® View information did not affect average drug titration behaviour. However, small improvements in control of MAP and BIS and early recovery suggest improved titration for some patients without increasing the risk of overdosing or underdosing. CLINICAL TRIAL REGISTRATION: NCT01467167.


Asunto(s)
Anestesiología , Anestésicos , Anestesia General , Electroencefalografía , Humanos , Periodo Posoperatorio , Estudios Prospectivos
15.
J Anesth ; 36(2): 294-302, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35147768

RESUMEN

This narrative review intends to provide the anesthesiologist with the basic knowledge of the Bayesian concepts and should be considered as a tutorial for anesthesiologists in the concept of Bayesian statistics. The Bayesian approach represents the mathematical formulation of the idea that we can update our initial belief about data with the evidence obtained from any kind of acquired data. It provides a theoretical framework and a statistical method to use pre-existing information within the context of new evidence. Several authors have described the Bayesian approach as capable of dealing with uncertainty in medical decision-making. This review describes the Bayes theorem and how it is used in clinical studies in anesthesia and critical care. It starts with a general introduction to the theorem and its related concepts of prior and posterior probabilities. Second, there is an explanation of the basic concepts of the Bayesian statistical inference. Last, a summary of the applicability of some of the Bayesian statistics in current literature is provided, such as Bayesian analysis of clinical trials and PKPD modeling.


Asunto(s)
Anestesia , Anestesiología , Anestesiólogos , Teorema de Bayes , Humanos
16.
Anesthesiology ; 134(1): 35-51, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33064833

RESUMEN

BACKGROUND: γ-Aminobutyric acid type A (GABAA) receptor agonists are known to cause involuntary muscle movements. The mechanism of these movements is not known, and its relationship to depth of anesthesia monitoring is unclear. We have explored the effect of involuntary muscle movement on the pharmacokinetic-pharmacodynamic model for the GABAA receptor agonist ABP-700 and its effects on the Bispectral Index (BIS) as well as the Modified Observer's Assessment of Alertness/Sedation (MOAA/S) scores. METHODS: Observations from 350 individuals (220 men, 130 women) were analyzed, comprising 6,312 ABP-700 concentrations, 5,658 ABP-700 metabolite (CPM-acid) concentrations, 25,745 filtered BIS values, and 6,249 MOAA/S scores, and a recirculatory model developed. Various subject covariates and pretreatment with an opioid or a benzodiazepine were explored as covariates. Relationships between BIS and MOAA/S models and involuntary muscle movements were examined. RESULTS: The final model shows that the pharmacokinetics of ABP-700 are characterized by small compartmental volumes and rapid clearance. The BIS model incorporates an effect-site for BIS suppression and a secondary excitatory/disinhibitory effect-site associated with a risk of involuntary muscle movements. The secondary effect-site has a threshold that decreases with age. The MOAA/S model did not show excitatory effects. CONCLUSIONS: The GABAA receptor agonist ABP-700 shows the expected suppressive effects for BIS and MOAA/S, but also disinhibitory effects for BIS associated with involuntary muscle movements and reduced by pretreatment. Our model provides information about involuntary muscle movements that may be useful to improve depth of anesthesia monitoring for GABAA receptor agonists.


Asunto(s)
Anestesia , Monitores de Conciencia , Etomidato/análogos & derivados , Agonistas de Receptores de GABA-A/farmacología , Imidazoles/farmacología , Adulto , Algoritmos , Analgésicos Opioides , Benzodiazepinas , Sedación Consciente , Etomidato/farmacocinética , Femenino , Agonistas de Receptores de GABA-A/farmacocinética , Humanos , Imidazoles/farmacocinética , Masculino , Monitoreo Intraoperatorio , Músculo Liso/efectos de los fármacos , Medicación Preanestésica
17.
Br J Anaesth ; 126(2): 386-394, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33317804

RESUMEN

BACKGROUND: Target-controlled infusion (TCI) systems incorporating pharmacokinetic (PK) or PK-pharmacodynamic (PK-PD) models can be used to facilitate drug administration. Existing models were developed using data from select populations, the use of which is, strictly speaking, limited to these populations. Recently a propofol PK-PD model was developed for a broad population range. The aim of the study was to prospectively validate this model in children, adults, older subjects, and obese adults undergoing general anaesthesia. METHODS: The 25 subjects included in each of four groups were stratified by age and weight. Subjects received propofol through TCI with the Eleveld model, titrated to a bispectral index (BIS) of 40-60. Arterial blood samples were collected at 5, 10, 20, 30, 40, and 60 min after the start of propofol infusion, and every 30 min thereafter, to a maximum of 10 samples. BIS was recorded continuously. Predictive performance was assessed using the Varvel criteria. RESULTS: For PK, the Eleveld model showed a bias < ±20% in children, adults, and obese adults, but a greater bias (-27%) in older subjects. Precision was <30% in all groups. For PD, the bias and wobble were <5 BIS units and the precision was close to 10 BIS units in all groups. Anaesthetists were able to achieve intraoperative BIS values of 40-60 using effect-site target concentrations about 85-140% of the age-adjusted Ce50. CONCLUSIONS: The Eleveld propofol PK-PD model showed predictive precision <30% for arterial plasma concentrations and BIS predictions with a low (population) bias when used in TCI in clinical anaesthesia practice.


Asunto(s)
Anestesia General , Anestésicos Intravenosos/farmacocinética , Estado de Conciencia/efectos de los fármacos , Modelos Biológicos , Propofol/farmacocinética , Adolescente , Adulto , Factores de Edad , Anciano , Anestésicos Intravenosos/administración & dosificación , Anestésicos Intravenosos/sangre , Peso Corporal , Niño , Preescolar , Femenino , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Obesidad , Propofol/administración & dosificación , Propofol/sangre , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
18.
Br J Anaesth ; 127(3): 415-423, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34246461

RESUMEN

BACKGROUND: Remimazolam is a new benzodiazepine for procedural sedation and general anaesthesia. The aim of this study was to characterise its pharmacokinetic properties and safety in renally and hepatically impaired subjects. METHODS: Two separate trials were conducted in patients with hepatic (n=11) or renal impairment (n=11) compared with matched healthy subjects (n=9 and n=12, respectively). The hepatic impairment trial was an open-label adaptive 'Reduced Design' trial, using a single bolus of remimazolam 0.1 mg kg-1 i.v., whereas the renal impairment trial was an open-label trial of a single bolus dose of remimazolam 1.5 mg i.v. Remimazolam plasma concentrations over time were analysed by population pharmacokinetic modelling. RESULTS: Remimazolam pharmacokinetic properties were adequately described by a three-compartment, recirculatory model. Exposure in subjects with severe hepatic impairment was 38.1% higher (i.e. clearance was 38.1% lower) compared with healthy volunteers. This increase caused a slightly delayed recovery (8.0 min for healthy, 12.1 min for moderate, and 16.7 min for severe hepatic impairment). With renal impairment, plasma clearance was comparable with that measured in healthy subjects. Simulations of Cmax after a bolus dose of 10 mg showed no relevant impact of hepatic or renal impairment. The overall incidence of adverse events was low, and all adverse events were mild. CONCLUSIONS: As Cmax after a remimazolam bolus i.v. was not affected by hepatic or renal impairment, no dose adjustments are required. No unexpected adverse events related to remimazolam were seen in subjects with renal or hepatic impairment. CLINICAL TRIAL REGISTRATION: Hepatic impairment trial: ClinicalTrials.gov, NCT01790607 (https://clinicaltrials.gov/ct2/show/NCT01790607). Renal impairment trial: EudraCT Number: 2014-004575-23.


Asunto(s)
Benzodiazepinas/farmacocinética , Tasa de Filtración Glomerular , Hipnóticos y Sedantes/farmacocinética , Enfermedades Renales/fisiopatología , Riñón/fisiopatología , Hepatopatías/fisiopatología , Hígado/fisiopatología , Adulto , Benzodiazepinas/administración & dosificación , Benzodiazepinas/efectos adversos , Benzodiazepinas/sangre , Simulación por Computador , Monitoreo de Drogas , Femenino , Humanos , Hungría , Hipnóticos y Sedantes/administración & dosificación , Hipnóticos y Sedantes/efectos adversos , Hipnóticos y Sedantes/sangre , Inyecciones Intravenosas , Enfermedades Renales/diagnóstico , Hepatopatías/diagnóstico , Masculino , Persona de Mediana Edad , Modelos Biológicos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Estados Unidos
19.
BMC Emerg Med ; 21(1): 135, 2021 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-34773982

RESUMEN

BACKGROUND: Clinical reasoning is a crucial task within the Emergency Medical Services (EMS) care process. Both contextual and cognitive factors make the task susceptible to errors. Understanding the EMS care process' structure could help identify and address issues that interfere with clinical reasoning. The EMS care process is complex and only basically described. In this research, we aimed to define the different phases of the process and develop an overarching model that can help detect and correct potential error sources, improve clinical reasoning and optimize patient care. METHODS: We conducted a focused ethnography study utilizing non-participant video observations of real-life EMS deployments combined with thematic analysis of peer interviews. After an initial qualitative analysis of 7 video observations, we formulated a tentative conceptual model of the EMS care process. To test and refine this model, we carried out a qualitative, thematic analysis of 28 video-recorded cases. We validated the resulting model by evaluating its recognizability with a peer content analysis utilizing semi-structured interviews. RESULTS: Based on real-life observations, we were able to define and validate a model covering the distinct phases of an EMS deployment. We have introduced the acronym "SPART" to describe ten different phases: Start, Situation, Prologue, Presentation, Anamnesis, Assessment, Reasoning, Resolution, Treatment, and Transfer. CONCLUSIONS: The "SPART" model describes the EMS care process and helps to understand it. We expect it to facilitate identifying and addressing factors that influence both the care process and the clinical reasoning task embedded in this process.


Asunto(s)
Servicios Médicos de Urgencia , Antropología Cultural , Humanos , Proyectos de Investigación
20.
Br J Anaesth ; 125(4): 483-491, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32654750

RESUMEN

BACKGROUND: Target-controlled infusion (TCI) systems use pharmacokinetic (PK) models to predict the drug infusion rates necessary to achieve a desired target plasma or effect-site concentration. As new PK models are developed and implemented in TCI systems, there can be uncertainty as to which target concentrations are appropriate. Existing dose recommendations can serve as a point of reference to identify target concentrations suitable for clinical applications. METHODS: Simulations of remifentanil TCI were performed using three PK models (Minto, Eleveld, and Kim). We sought to identify models and target concentrations for remifentanil administration in children, adult, older people, and severely obese individuals, consistent with the remifentanil product label. In a typical adult this is an induction dose of 0.5-1 µg kg-1 and starting maintenance infusion rate of 0.25 µg kg-1 min-1. RESULTS: For the Minto, Eleveld, and Kim remifentanil models, a plasma target concentration of ∼ 4 ng ml-1 achieves drug administration consistent with product label recommended initial doses for all groups with minor exceptions. With effect-site targeting in older individuals, a target concentration of ∼2 ng ml-1 is required for induction and ∼4 ng ml-1 for starting maintenance to achieve drug dosages close to product label recommendations. CONCLUSIONS: We identified remifentanil TCI target concentrations that resulted in drug administration similar to product label dosing recommendations. This approach did not necessarily identify target concentrations that achieve desired clinical effect, only those that are consistent with the product label recommended doses. We estimate that plasma target concentrations of 3.1-5.3 ng ml-1 are suitable for initial dosing.


Asunto(s)
Remifentanilo/administración & dosificación , Adolescente , Adulto , Anciano , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Infusiones Intravenosas , Persona de Mediana Edad , Modelos Biológicos , Remifentanilo/farmacocinética , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA