Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Indoor Air ; 32(11): e13153, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437662

RESUMEN

We performed a cross-sectional survey of 2143 female students in a university in Tianjin, China regarding perceived air quality (PAQ) and sick building syndrome (SBS) symptoms in the student dormitory. The prevalence of general, mucosal, and skin symptoms was 22.1%, 21.9%, and 26.3%, respectively. The three most prevalent PAQ complaints were "dry air" (48.9% often), "stuffy odor" (18.2%), and "other unpleasant odors" (5.1%), and they were significant risk factors for 11-12 out of 12 SBS symptoms (adjusted odds ratios [AOR]: 1.6-5.8). Survey data of 1471 undergraduates, whose dorms were of uniform layout and furnishing, were used to further investigate the influences of occupancy level and occupant behaviors on PAQ and SBS symptoms. Frequent use of air freshener/perfume was a significant risk factor for "dry air," less frequent room cleaning and higher occupancy density were significant risk factors for "stuffy odor," and less natural ventilation was a significant risk factor for both "stuffy odor" and "pungent odor." These factors were also significantly associated with some SBS symptoms. In particular, the use of air freshener/perfume exhibited a significant dose-response pattern with "fatigue" (sometimes: AOR 1.3; often: AOR 2.0) and with "irritated, stuffy, or runny nose" (sometimes: AOR 1.6; often: AOR 2.2).


Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Perfumes , Síndrome del Edificio Enfermo , Humanos , Femenino , Síndrome del Edificio Enfermo/epidemiología , Síndrome del Edificio Enfermo/etiología , Estudios Transversales , Contaminación del Aire Interior/efectos adversos , Estudiantes
2.
Indoor Air ; 32(8): e13084, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-36040279

RESUMEN

House dust mites produce well-known allergens for asthma and allergy among children. To study house dust mite allergen exposure level in northeast China and characterize its association with indoor environmental factors and cleaning habits, we inspected 399 homes in Tianjin area and collected dust from mattresses. Dermatophagoides farinae (Der f) and Dermatophagoides pteronyssinus (Der p) were detected by the enzyme-linked immunosorbent assay (ELISA) method. The medians of total allergen concentrations for spring, summer, autumn, and winter were 524 ng/g, 351 ng/g, 1022 ng/g, and 1010 ng/g. High indoor air relative humidity (RH), low air change rate, indoor dampness, and frequent changing of quilt cover/bedsheet/pillow case were significantly associated with high house dust mite allergen concentration (relative risk [RR]: RH, 1.18-1.34; air change rate, 0.97-1.00; dampness, 2.92-3.83; changing quilt cover/bedsheet/pillow case, 0.66-0.75). The decrease in the absolute humidity gradient between indoors and outdoors that occurs with increased air change rate may explain why a high ventilation reduces house dust mite allergen concentration. The findings of this study show the importance of ventilation and cleaning for controlling house dust mite allergens. We found that the decrease in additional absolute humidity (e.g., humidity indoor -humidity outdoor ) with increased air change rate may be the main reason that a high ventilation rate reduces house dust mite allergen concentration. Ventilation and cleaning should be both considered for creating a healthy home environment.


Asunto(s)
Contaminación del Aire Interior , Ambiente en el Hogar , Contaminación del Aire Interior/análisis , Alérgenos/análisis , Animales , Antígenos Dermatofagoides , Niño , Polvo/análisis , Humanos , Estilo de Vida , Pyroglyphidae
3.
Indoor Air ; 32(11): e13178, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437656

RESUMEN

Ozone and byproducts of ozone-initiated reactions are among the primary pollutants in aircraft cabins. However, investigations of the spatial distribution and reaction mechanisms of these pollutants are insufficient. This study established a computational fluid dynamics-based model to evaluate ozone and byproduct distribution, considering ozone reactions in air, adsorption onto surfaces, and byproduct desorption from surfaces. The model was implemented in an authentic single-aisle aircraft cabin and validated by measurements recorded during the aircraft cruise phase. Ozone concentrations in the supply air-dominated area were approximately 50% higher than that in the passenger breathing zone, suggesting that human surfaces represent a significant ozone sink. The deposition velocity onto human bodies was 21.83 m/h, surpassing 3.97 m/h on other cabin interior surface areas. Our model provides a mechanistic tool to analyze ozone and byproduct concentration distributions, which would be useful for assessing passenger health risks and for developing strategies for healthier aircraft cabin environments.


Asunto(s)
Contaminación del Aire Interior , Contaminantes Ambientales , Ozono , Humanos , Ozono/análisis , Contaminación del Aire Interior/análisis , Aeronaves , Hidrodinámica
4.
Indoor Air ; 32(10): e13141, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36305078

RESUMEN

Exposure to formaldehyde causes a variety of adverse health outcomes, while the distributions of indoor formaldehyde in different building types are still not clear in China. In this study, based on the systematic review of previously published data and Monte Carlo simulation, we assessed geographical and temporal distributions of indoor formaldehyde concentrations in residences, schools, and offices across China. A total of 397 studies covered 34 provincial-level regions since 1986 were collected. The results showed that indoor formaldehyde concentrations in residences, schools, and offices in nationwide were decreasing over years due to the publishment of indoor air quality standards since 2002. During 2011 to 2015, the median concentrations of indoor formaldehyde in newly renovated residences, schools, and offices were 153 µg/m3 , 163 µg/m3 , and 94 µg/m3 , with an exceeding rate of 82%, 46%, and 91% considering a standard threshold of 100 µg/m3 at that time, while the exceeding rate was less than 5% for buildings that were renovated beyond one year. Our findings release the temporal trends and geographic distributions of indoor formaldehyde concentrations in residences, schools, and offices in China in the past 30 years, and provide basic data for the comprehensive evaluation of disease burden attributable to indoor formaldehyde exposure.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Hipersensibilidad Respiratoria , Humanos , Contaminación del Aire Interior/análisis , Formaldehído/análisis , Vivienda , Instituciones Académicas , Hipersensibilidad Respiratoria/inducido químicamente , China , Contaminantes Atmosféricos/análisis
5.
Indoor Air ; 32(1): e12918, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34337784

RESUMEN

A questionnaire survey on dermal symptoms and home environment was performed in eight Chinese cities (40 279 participants). Data on city level temperature, precipitation, PM10 , NO2, and gross domestic product (GDP) per capita were collected. In total, 2.2% had eczema, 2.4% facial erythema (FE) and 2.6% seborrheic dermatitis symptoms (SD). Higher temperature was associated with eczema (OR = 1.09). Higher GDP per capita was related to less SD. Higher PM10 was related to SD. Suburban living was protective for eczema (OR = 0.77) (vs. urban). Living in old buildings (built before 1991) was related to eczema (OR = 1.42). Living near heavily trafficked roads was related to FE (OR = 1.33) and SD (OR = 1.35). Having new furniture was related to all symptoms (OR = 1.26-1.47). Burning mosquito coils (OR = 1.37-1.57) and incense (OR = 1.33-1.37) were associated with eczema, FE, or SD. Presence of cockroaches and rats/mice was associated with FE or SD (OR = 1.31-1.40). Using air conditioner, daily cleaning and frequently exposing bedding to sunshine were protective (OR = 0.60-0.83). In conclusion, higher temperature, higher PM10 , urban living, living near heavily trafficked roads, old buildings, new furniture, burning mosquito coils and incense, and presence of cockroaches/rats/mice increased the risk of eczema, FE, or SD. Higher GDP, air conditioner, daily cleaning, and exposing bedding to sunshine were protective.


Asunto(s)
Contaminación del Aire , Dermatitis Seborreica , Eccema , Eritema , Contaminantes Atmosféricos/análisis , Contaminantes Atmosféricos/toxicidad , Contaminación del Aire/análisis , Contaminación del Aire/estadística & datos numéricos , Contaminación del Aire Interior/análisis , Contaminación del Aire Interior/estadística & datos numéricos , Animales , China/epidemiología , Dermatitis Seborreica/epidemiología , Eccema/epidemiología , Eritema/epidemiología , Eritema/etiología , Ambiente en el Hogar , Humanos , Ratones , Material Particulado/análisis , Material Particulado/toxicidad , Ratas , Factores de Riesgo , Adulto Joven
6.
Indoor Air ; 32(6): e13063, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35762240

RESUMEN

Common cold is usually considered to be associated with outdoor climate, but the evidence linking with indoor environmental factors is lacking. The role of indoor renovations during which critical timing window on childhood common cold remains unclear. Therefore, we investigated the effect of exposure to new furniture and/or redecoration during prenatal and postnatal periods on the occurrence and duration of common cold in preschool children. We conducted a retrospective cohort study of 39 782 children aged 3-6 years in seven cities of China. The occurrence and duration of common cold in children, and their lifetime exposures to indoor new furniture and redecoration (including pregnancy, the first year of life, and after one year old) were assessed using a questionnaire administered by the parents. Associations between high frequency (>5 colds) and long duration (≥2 weeks per cold) of common cold during past 12 months and exposure to indoor new furniture/redecoration were examined by logistic regression models in terms of odds ratio (OR) and 95% confidence interval (CI). We found that the prevalence of high frequency and long duration of common cold in preschool children in China were, respectively, 9.2% and 11.9%. Frequent common cold was significantly associated with exposure to indoor new furniture/redecoration during pregnancy, first year, and after 1 year old, respectively, with the ORs (95% CI) = 1.25 (1.12-1.39), 1.11 (1.00-1.25), and 1.09 (1.01-1.18). Furthermore, childhood long duration per cold was associated with exposure to indoor new furniture/redecoration during pregnancy with OR (95% CI) of 1.14 (1.03-1.25) but not with postnatal exposure. We identified that prenatal exposure to home renovation was more critical than postnatal exposure for an increased risk of high frequency and long duration of common cold. Sensitivity analysis showed that the association between prenatal exposure to indoor renovations and the risk of childhood common cold was consistent and robust, and the associations were modified by some personal and indoor environmental factors. Our findings indicated that prenatal and postnatal exposure to home renovation played an important role in the risk of childhood common cold, supporting the hypothesis of "fetal origin of childhood infection."


Asunto(s)
Contaminación del Aire Interior , Resfriado Común , Efectos Tardíos de la Exposición Prenatal , Contaminación del Aire Interior/análisis , Preescolar , China/epidemiología , Resfriado Común/epidemiología , Exposición a Riesgos Ambientales , Femenino , Humanos , Lactante , Embarazo , Estudios Retrospectivos , Factores de Riesgo
7.
Indoor Air ; 32(11): e13154, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437653

RESUMEN

Indoor radon exposure is thought to be associated with adverse health effect as lung cancer. Lung cancer incidences in China have been the highest worldwide during the past two decades. It is important to quantitively address indoor radon exposure and its health effect, especially in countries like China. In this paper, we have conducted a meta-analysis based on indoor radon and its health effect studies from a systematic review between 2000 and 2020. A total of 8 studies were included for lung cancer. We found that the relative risk (RR) was 1.01 (95% CI: 1.01-1.02) per 10 Bq/m3 increase of indoor radon for lung cancer in China. The subgroup analysis found no significant difference between the conclusions from the studies from China and other regions. The health effect of indoor radon exposure is relatively consistent for the low-exposure and high-exposure groups in the subgroup analysis. With a better understanding of exposure level of indoor radon, the outcomes and conclusions of this study will provide supports for next phase of researches on estimation of environmental burden of disease by indoor radon exposures in countries like China.


Asunto(s)
Contaminación del Aire Interior , Neoplasias Pulmonares , Radón , Humanos , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Factores de Riesgo , Radón/efectos adversos , Radón/análisis , Neoplasias Pulmonares/epidemiología , Neoplasias Pulmonares/etiología , China/epidemiología
8.
Indoor Air ; 32(11): e13170, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437665

RESUMEN

The burden of disease attributed to the indoor exposure to sulfur dioxide (SO2 ), nitrogen dioxide (NO2 ), ozone (O3 ), and carbon monoxide (CO) is not clear, and the quantitative concentration-response relationship is a prerequisite. This is a systematic review to summarize the quantitative concentration-response relationships by screening and analyzing the polled effects of population-based epidemiological studies. After collecting literature published between 1980 and 2019, a total of 19 health outcomes in 101 studies with 182 health risk estimates were recruited. By meta-analysis, the leave-one-out sensitivity analysis and Egger's test for publication bias, the robust and reliable effects were found for SO2 (per 10 µg/m3 ) with chronic obstructive pulmonary diseases (COPD) (pooled relative risks [RRs] 1.016, 95% CI: 1.012-1.021) and cardiovascular diseases (CVD) (RR 1.012, 95%CI: 007-1.018), respectively. NO2 (per 10 µg/m3 ) had the pooled RRs for childhood asthma, preterm birth, lung cancer, diabetes, and COPD by 1.134 (1.084-1.186), 1.079 (1.007-1.157), 1.055 (1.010-1.101), 1.019 (1.009-1.029), and 1.016 (1.012-1.120), respectively. CO (per 1 mg/m3 ) was significantly associated with Parkinson's disease (RR 1.574, 95% CI: 1.069-2.317) and CVD (RR 1.024, 95% CI: 1.011-1.038). No robust effects were observed for O3 . This study provided evidence and basis for further estimation of the health burden attributable to the four gaseous pollutants.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Contaminación del Aire , Enfermedades Cardiovasculares , Ozono , Nacimiento Prematuro , Enfermedad Pulmonar Obstructiva Crónica , Recién Nacido , Femenino , Humanos , Niño , Dióxido de Nitrógeno , Monóxido de Carbono , Dióxido de Azufre , Contaminación del Aire/análisis , Contaminantes Atmosféricos/efectos adversos , Contaminantes Atmosféricos/análisis , Exposición a Riesgos Ambientales/efectos adversos , Exposición a Riesgos Ambientales/análisis , Azufre
9.
Indoor Air ; 32(9): e13091, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36168233

RESUMEN

The last two decades have witnessed rapid urbanization and economic growth accompanied by severe indoor air pollution of volatile organic compounds (VOCs) in China. However, indoor VOC pollution across China has not been well characterized and documented. This study is a systematic review of field measurements of eight target VOCs (benzene, toluene, xylenes, acetaldehyde, p-dichlorobenzene, butadiene, trichloroethylene, and tetrachloroethylene) in residences, offices, and schools in China from 2000 to 2021. The results show that indoor pollution of benzene, toluene, and xylenes has been more serious in China than in other countries. Spatiotemporal distribution shows lower indoor VOC levels in east and south-east regions and a declining trend from 2000 to 2021. Moving into a dwelling more than 1 year after decoration and improving ventilation could significantly reduce exposure to indoor VOCs. Reducing benzene exposure is urgently needed because it is associated with greater health risks (4.5 × 10-4 for lifetime cancer risk and 8.3 for hazard quotient) than any other VOCs. The present study enriches the database of indoor VOC levels and provides scientific evidence for improving national indoor air quality standards as well as estimating the attributable disease burden caused by VOCs in China.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Tetracloroetileno , Tricloroetileno , Compuestos Orgánicos Volátiles , Acetaldehído , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Benceno/análisis , Butadienos , China , Monitoreo del Ambiente , Medición de Riesgo , Instituciones Académicas , Tolueno , Compuestos Orgánicos Volátiles/análisis , Xilenos/análisis
10.
Indoor Air ; 32(5): e13038, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35622720

RESUMEN

Exposure to volatile organic compounds (VOCs) indoors is thought to be associated with several adverse health effects. However, we still lack concentration-response (C-R) relationships between VOC levels in civil buildings and various health outcomes. For this paper, we conducted a systematic review and meta-analysis of observational studies to summarize related associations and C-R relationships. Four databases were searched to collect all relevant studies published between January 1980 and December 2017. A total of 39 studies were identified in the systematic review, and 32 of these were included in the meta-analysis. We found that the pooled relative risk (RR) for leukemia was 1.03 (95% CI: 1.01-1.05) per 1 µg/m3 increase of benzene and 1.25 (95%CI: 1.14-1.37) per 0.1 µg/m3 increase of butadiene. The pooled RRs for asthma were 1.08 (95% CI: 1.02-1.14), 1.02 (95% CI: 1.00-1.04), and 1.04 (95% CI: 1.02-1.06) per 1 µg/m3 increase of benzene, toluene, and p-dichlorobenzene, respectively. The pooled RR for low birth weight was 1.12 (95% CI: 1.05-1.19) per 1 µg/m3 increase of benzene. Our findings provide robust evidence for associations between benzene and leukemia, asthma, and low birth weight, as well as for health effects of some other VOCs.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Asma , Leucemia , Compuestos Orgánicos Volátiles , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Benceno/análisis , Humanos , Leucemia/epidemiología , Leucemia/etiología , Estudios Observacionales como Asunto , Compuestos Orgánicos Volátiles/análisis
11.
Indoor Air ; 32(4): e13030, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35481931

RESUMEN

China's profoundly rapid modernization in the past two decades has resulted in dramatic changes in indoor environmental exposures. Among these changes, exposure to phthalates has attracted increasing attention. We aimed to characterize indoor phthalate exposure and to estimate the disease burden attributable to indoor phthalate pollution from 2000 to 2017 in China. We integrated the national exposure level of indoor phthalates from literature through systematic review and Monte Carlo simulation. Dose-response relationships between phthalate exposure and health outcomes were obtained by systematic review and meta-analysis. Based on existing models for assessing probabilities of causation and a comprehensive review of available data, we calculated the disability-adjusted life years (DALYs) among the general Chinese population resulting from exposure to indoor phthalate pollution. We found that DnBP, DiBP, and DEHP were the most abundant phthalates in indoor environments of residences, offices, and schools with medians of national dust phase concentration from 74.5 µg/g to 96.3 µg/g, 39.6 µg/g to 162.5 µg/g, 634.2 µg/g to 1,394.7 µg/g, respectively. The national equivalent exposure for children to phthalates in settled dust was higher than that of adults except for DiBP and DnOP. Dose-response relationships associated with DEP, DiBP, DnBP, BBzP, and DEHP exposures were established. Between 2000 and 2017, indoor phthalate exposure in China has led to 3.32 million DALYs per year, accounting for 0.90% of total DALYs across China. The annual DALY associated with indoor phthalate pollution in China was over 2000 people per million, which is about 2~3 times of the DALY loss due to secondhand smoke (SHS) in six European countries or the sum of the DALY loss caused by indoor radon and formaldehyde in American homes. Our study indicates a considerable socioeconomic impact of indoor phthalate exposure for a modernizing human society. This suggest the need for relevant national standard and actions to reduce indoor phthalate exposure.


Asunto(s)
Contaminación del Aire Interior , Dietilhexil Ftalato , Adulto , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Niño , China/epidemiología , Costo de Enfermedad , Dietilhexil Ftalato/análisis , Polvo/análisis , Humanos , Ácidos Ftálicos , Estados Unidos
12.
Indoor Air ; 32(1): e12920, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34432341

RESUMEN

After decades of development, the indoor environment in China has changed. A systematic review was conducted from peer-reviewed scientific papers with field test data of indoor radon in China from 2000 to 2020 for three types of buildings. The mean concentrations of indoor radon for dwellings, school buildings, and office buildings are 54.6, 56.1, and 54.9 Bq/m3 . The indoor radon concentration was related to seasons, climate regions, ventilation, decoration, and other factors such as soil and outdoor air. Colder seasons, especially in severe colder areas of China, newer decorated buildings, closed windows, and doors were all associated with higher indoor radon concentrations. Variables like climate region and ventilation showed statistical significance in the correlation analysis. Regarding the increasing trend of indoor radon concentration in China during the last two decades, further study of indoor radon is necessary especially for school buildings and office buildings, and will help access its environmental burden of disease in China more accurately.


Asunto(s)
Contaminantes Radiactivos del Aire , Contaminación del Aire Interior , Monitoreo de Radiación , Radón , Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , China , Vivienda , Radón/análisis , Instituciones Académicas
13.
Indoor Air ; 31(2): 383-391, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32939827

RESUMEN

Building ventilation is important for occupants' health. There are few studies of associations between home ventilation and occupant's health in China. During 2013-2016, we measured ventilation in 399 homes in Tianjin and Cangzhou, China, and surveyed the health history of children. Ventilation rates were measured using mass balance of occupant generated CO2 . The associations of home ventilation with children's asthma and allergy were analyzed in different strata of time and space. A low bedroom ventilation at night was significantly associated with an increased proportion of rhinitis among children (rhinitis current, adjusted odds ratio (AOR): 1.59; 95% confidence interval (CI): 1.01-2.49; diagnosed rhinitis, AOR: 3.02 (1.16-7.89)). Our findings suggest a dose-response relationship between ventilation rate at night in children's bedrooms and rhinitis current. The night-time ventilation rate in bedrooms has a greater association with rhinitis than the whole home ventilation rate during daytime.


Asunto(s)
Contaminación del Aire Interior/estadística & datos numéricos , Asma/epidemiología , Hipersensibilidad/epidemiología , Ventilación , Niño , China/epidemiología , Exposición a Riesgos Ambientales , Vivienda , Humanos , Respiración , Rinitis , Factores de Riesgo
14.
Indoor Air ; 31(6): 2200-2212, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34164852

RESUMEN

Carbon dioxide (CO2 ) is an important environmental parameter in aircraft cabins. To understand the most recent, real-time CO2 concentration levels and their key influencing factors in aircraft cabins, we conducted in-flight measurements of 52 randomly selected commercial flights with different aircraft types and durations from August 2017 to August 2019. The spatial temporal characteristics of CO2 concentrations on board were analyzed and summarized. For the flight time scale, the CO2 concentrations during the boarding phase (1680 ± 558 ppmv) were notably higher than that in other phases, whereas the condition of the cruising phase was the lowest in most flights. The flight average CO2 concentrations of the cruising phase were 1253 ± 164 ppmv, and the corresponding estimated outside airflow rates were 6.2 ± 1.3 L/s/p in the economy class across all flights. Single-aisle and twin-aisle flights did not show noticeable differences for the same phases. Relatively uniform CO2 concentrations were observed at different positions of the same class. By comparing the results of this study with those previously reported, CO2 concentrations showed a slightly decreasing trend over the last 30 years. This suggested a slightly increased ventilation rate and potentially superior air quality on board.


Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Contaminación del Aire Interior/análisis , Aeronaves , Dióxido de Carbono/análisis
15.
Indoor Air ; 31(6): 2084-2098, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34240486

RESUMEN

Volatile organic compounds (VOCs) as a non-negligible aircraft cabin air quality (CAQ) factor influence the health and comfort of passengers and crew members. On-board measurements of carbonyls (short-chain (C1 -C6 )) and other volatile organic compounds (VOCs, long-chain (C6 -C16 )) with a total of 350 samples were conducted in 56 commercial airliner cabins covering 8 aircraft models in this study. The mean concentration for each individual carbonyl compound was between 0.3 and 8.3 µg/m3 (except for acrolein & acetone, average = 20.7 µg/m3 ) similar to the mean concentrations of other highly detected VOCs (long-chain (C6 -C16 ), 97% of which ranged in 0-10 µg/m3 ) in aircraft cabins. Formaldehyde concentrations in flights were significantly lower than in residential buildings, where construction materials are known formaldehyde sources. Acetone is a VOC emitted by humans, and its concentration in flights was similar to that in other high-occupant density transportation vehicles. The variation of VOC concentrations in different flight phases of long-haul flights was the same as that of CO2 concentration except for the meal phase, which indicates the importance of cabin ventilation in diluting the gaseous contaminants, while the sustained and slow growth of the VOC concentrations during the cruising phase in short-haul flights indicated that the ventilation could not adequately dilute the emission of VOCs. For the different categories of VOCs, the mean concentration during the cruising phase of benzene series, aldehydes, alkanes, other VOCs (detection rate > 50%), and carbonyls in long-haul flights was 44.2 µg/m3 , 17.9 µg/m3 , 18.6 µg/m3 , 31.5 µg/m3 , and 20.4 µg/m3  lower than those in short-haul flights, respectively. Carbonyls and d-limonene showed a significant correlation with meal service (p < 0.05). Unlike the newly decorated rooms or new vehicles, the inner materials were not the major emission sources in aircraft cabins. Practical Implications. The on-board measurements of 56 flights enrich the VOC database of cabin environment, especially for carbonyls. The literature review of carbonyls in the past 20 years contributes to the understanding the current status of cabin air quality (CAQ). The analysis of VOC concentration variation for different flight phases, flight duration, and aircraft age lays a foundation for exploring effective control methods, including ventilation and purification for cabin VOC pollution. The enriched VOC data is helpful to explore the key VOCs of aircraft cabin environment and to evaluate the acute/chronic health exposure risk of pollutants for passengers and crew members.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Contaminación del Aire , Compuestos Orgánicos Volátiles , Contaminantes Atmosféricos/análisis , Contaminación del Aire/análisis , Contaminación del Aire Interior/análisis , Aeronaves , Formaldehído/análisis , Humanos , Compuestos Orgánicos Volátiles/análisis
16.
Indoor Air ; 31(4): 1018-1028, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33620091

RESUMEN

The indoor environment influences occupants' health. From March 1, 2018, to February 28, 2019, we continuously monitored indoor temperature (T), relative humidity (RH), and CO2 concentration in bedrooms via an online system in 165 residences that covered all five climate zones of China. Meanwhile, we asked one specific occupant in each home to complete questionnaires about perceived air quality and sick building syndrome (SBS) symptoms at the end of each month. Higher CO2 concentration was significantly associated with a higher percentage of perceived stuffy odor and skin SBS symptoms. Higher relative humidity was associated with higher percentage of perceived moldy odor and humid air, while lower RH was associated with a higher percentage of perceived dry air. Occupants who lived in residences with high RH were less likely to have mucosal and skin SBS symptoms (adjusted odds ratio (AOR): 0.73-0.78). However, the benefit of high humidity for perceived dry air and skin dryness symptoms is weaker if there is a high CO2 concentration level.


Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Síndrome del Edificio Enfermo , Contaminación del Aire Interior/análisis , Dióxido de Carbono , China/epidemiología , Humanos , Humedad , Síndrome del Edificio Enfermo/epidemiología , Síndrome del Edificio Enfermo/etiología , Temperatura
17.
Indoor Air ; 31(6): 1691-1706, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34181775

RESUMEN

Indoor ammonia (NH3 ) pollution has been paid more and more attention in view of its health risk. However, few studies have investigated the exposure level in the non-occupational environment in China. This study systematically reviewed the indoor ammonia exposure level in different regions, the equivalent exposure concentration of different populations, and the factors that influence indoor air ammonia in residences, offices, and schools in China. The literature published in 1980-2019 from main databases was searched and detailed screened, and finally, 56 related studies were selected. The results illustrated that the median concentration of indoor air ammonia in residences, offices, and school buildings was 0.21 mg/m3 , 0.26 mg/m3 , and 0.15 mg/m3 . There were 46.4%, 71.4%, and 40% of these samples exceeding the NH3  standard, respectively. The national concentrations and the equivalent exposure levels of adults and children were calculated and found to be higher than 0.20 mg/m3 . The concentration of ammonia varied greatly in different climate zones and economic development regions. Higher concentrations were found in the severe cold zone and the regions with higher economic level. This review reveals a high exposure risk of indoor air ammonia and the crucial impact of human emission, indoor air temperature, new concrete, and economic level, suggesting further investigation on indoor air ammonia evaluation and health effects.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Adulto , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Amoníaco/análisis , Niño , China , Monitoreo del Ambiente , Humanos , Instituciones Académicas
18.
Indoor Air ; 30(5): 827-840, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32297363

RESUMEN

During 2010-2012, we surveyed 40,010 3- to 6-year-old children in seven Chinese cities (Beijing, Taiyuan, Urumqi, Shanghai, Nanjing, Changsha, and Chongqing). Their parents reported information on household renovation, including the timing of renovation and the choice of materials for walls and floors in the child's room, and the incidence of their child's rhinitis. Multivariate and two-level (city-child) logistic regression analyses yielding adjusted odds ratios (AOR) with 95% confidence intervals were performed. Sensitivity analyses stratifying data for location and economic level were also performed. About 48.0% of the children had ever had allergic rhinitis, 41.2% had current allergic rhinitis, and 9.0% had had doctor-diagnosed rhinitis. Exposure to household renovation during early lifetime (birth to 1-year-old) had an AOR of 1.43 (1.04-1.9) for allergic rhinitis. The incidence of allergic rhinitis was significantly different in children exposed to different floor and wall covering materials. Floor or wall covering material composed of organic materials significantly increased the risk of childhood allergic rhinitis compared with tile flooring or lime wall covering. Oil paint had an AOR of 1.66 (1.28-2.14) for diagnosed rhinitis compared with lime wall covering. Adding new furniture the year before pregnancy was associated with an AOR of 1.18 (1.10-1.27) and 1.18 (1.11-1.25) for lifetime and current rhinitis. Solid wood or tiles/ceramic as floor materials, and using wallpaper, oil paint, or emulsion panels as wall materials were risk factors for doctor-diagnosed rhinitis. Sensitivity analyses showed that children living in southern or higher economic level China cities were more likely to have allergic rhinitis with household renovation.


Asunto(s)
Contaminación del Aire Interior/estadística & datos numéricos , Vivienda/estadística & datos numéricos , Rinitis Alérgica/epidemiología , Niño , Preescolar , China/epidemiología , Exposición a Riesgos Ambientales/estadística & datos numéricos , Composición Familiar , Femenino , Pisos y Cubiertas de Piso , Humanos , Masculino , Prevalencia , Encuestas y Cuestionarios
19.
Indoor Air ; 30(6): 1147-1165, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32845998

RESUMEN

Microbes in buildings have attracted extensive attention from both the research community and the general public due to their close relationship with human health. However, there still lacks comprehensive information on the indoor exposure level of microbes in China. This study systematically reviews exposure levels, the community structures, and the impact factors of airborne bacteria and fungi in residences, schools, and offices in China. We reviewed the major literature databases between 1980 and 2019 and selected 55 original studies based on a set of criteria. Results show that the concentration of indoor bacteria varies from 72.5 to 7500 CFU/m3 , with a median value of 1000 CFU/m3 , and the concentration of fungi varies from 12 to 9730 CFU/m3 , with a median value of 526 CFU/m3 . The concentration level of microbes varies in different climate zones, with higher bacterial concentrations in the severe cold zone, and higher fungal concentrations in the hot summer and warm winter zone. Among different buildings, classrooms have the highest average bacteria and fungi levels. This review reveals that a unified assessment system based on health effects is needed for evaluating the exposure levels of bacteria and fungi.


Asunto(s)
Microbiología del Aire , Contaminación del Aire Interior/estadística & datos numéricos , Exposición a Riesgos Ambientales/estadística & datos numéricos , Bacterias , Monitoreo del Ambiente , Hongos , Vivienda , Humanos , Instituciones Académicas , Estaciones del Año , Lugar de Trabajo
20.
Indoor Air ; 29(5): 828-839, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31230391

RESUMEN

The ventilation modalities in most Chinese residences are infiltration and opening windows. We measured infiltration rates and air change rates at night, with no attempt to change occupants' behaviors, of urban residences in five climate zones of China during four seasons. Using the CO2 decay method, we found the median infiltration rate for 294 residences to be 0.34 h-1 . Using occupant-generated CO2 as tracer gas, we determined air change rates over the course of 1 year in 46 bedrooms at night from mass balance considerations. In 54% of the measurements, windows were closed, so ventilation was only by infiltration. Windows were mainly closed when the outdoor temperature was below 15°C and above 26°C. The median infiltration rates did not differ appreciably among seasons and climate zones and were always less than 0.45 h-1 .


Asunto(s)
Vivienda , Ventilación/métodos , China , Bases de Datos Factuales , Humanos , Estaciones del Año , Población Urbana
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA