Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38490816

RESUMEN

BACKGROUND: Portal vein thrombosis (PVT) is thought to arise from stagnant blood flow, yet conclusive evidence is lacking. Relative residence time (RRT) assessed using 4D Flow MRI may offer insight into portal flow stagnation. PURPOSE: To explore the relationship between RRT values and the presence of PVT in cirrhotic participants. STUDY TYPE: Prospective. POPULATION: Forty-eight participants with liver cirrhosis (27 males, median age 67 years [IQR: 57-73]) and 20 healthy control participants (12 males, median age 45 years [IQR: 40-54]). FIELD STRENGTH/SEQUENCE: 3 T/4D Flow MRI. ASSESSMENT: Laboratory (liver and kidney function test results and platelet count) and clinical data (presence of tumors and other imaging findings), and portal hemodynamics derived from 4D Flow MRI (spatiotemporally averaged RRT [RRT-mean], flow velocity, and flow rate) were analyzed. STATISTICAL TESTS: We used multivariable logistic regression, adjusted by selected covariates through the Lasso method, to explore whether RRT-mean is an independent risk factor for PVT. The area under the ROC curve (AUC) was also calculated to assess the model's discriminative ability. P < 0.05 indicated statistical significance. RESULTS: The liver cirrhosis group consisted of 16 participants with PVT and 32 without PVT. Higher RRT-mean values (odds ratio [OR] 11.4 [95% CI: 2.19, 118]) and lower platelet count (OR 0.98 per 1000 µL [95% CI: 0.96, 0.99]) were independent risk factors for PVT. The incorporation of RRT-mean (AUC, 0.77) alongside platelet count (AUC, 0.75) resulted in an AUC of 0.84. When including healthy control participants, RRT-mean had an adjusted OR of 12.4 and the AUC of the combined model (RRT-mean and platelet count) was 0.90. DATA CONCLUSION: Prolonged RRT values and low platelet count were significantly associated with the presence of PVT in cirrhotic participants. RRT values derived from 4D Flow MRI may have potential clinical relevance in the management of PVT. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.

2.
Radiology ; 308(3): e230709, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37750777

RESUMEN

Background Percutaneous transhepatic portal vein (PV) embolization (PVE) is a standard preoperative procedure for advanced biliary cancer when the future liver remnant (FLR) is insufficient, yet the effect of this procedure on portal hemodynamics is still unclear. Purpose To assess whether four-dimensional (4D) MRI flowmetry can be used to estimate FLR volume and to identify the optimal time for this measurement. Materials and Methods This prospective single-center study enrolled consecutive adult patients with biliary cancer who underwent percutaneous transhepatic PVE for the right liver between June 2020 and November 2022. Portal hemodynamics were assessed using 4D flow MRI before PVE and within 1 day (0-day group) or 3-4 days (3-day group) after PVE. FLR volume was measured using CT before PVE and after PVE but before surgery. Blood flow changes were analyzed with the Wilcoxon signed rank test, and correlations with Spearman rank correlation. Results The 0-day group included 24 participants (median age, 72 years [IQR, 69-77 years]; 17 male participants), and the 3-day group included 13 participants (median age, 71 years [IQR, 68-78 years]; eight male participants). Both groups showed increased left PV (LPV) flow rate after PVE (0-day group: from median 3.72 mL/sec [IQR, 2.83-4.55 mL/sec] to 9.48 mL/sec [IQR, 8.12-10.7 mL/sec], P < .001; 3-day group: from median 3.65 mL/sec [IQR, 2.14-3.79 mL/sec] to 8.16 mL/sec [IQR, 6.82-8.98 mL/sec], P < .001). LPV flow change correlated with FLR volume change relative to the number of days from PVE to presurgery CT only in the 3-day group (ρ = 0.62, P = .02; 0-day group, P = .11). The output of the regression equation for estimating presurgery FLR volume correlated with CT-measured volume (ρ = 0.78; P = .002). Conclusion Four-dimensional flow MRI demonstrated increased blood flow in residual portal branches 3-4 days after PVE, offering insights for estimating presurgery FLR volume. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Roldán-Alzate and Oechtering in this issue.


Asunto(s)
Neoplasias del Sistema Biliar , Embolización Terapéutica , Neoplasias Hepáticas , Adulto , Humanos , Masculino , Anciano , Vena Porta/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Hígado/diagnóstico por imagen , Embolización Terapéutica/métodos , Imagen por Resonancia Magnética , Hemodinámica , Hepatectomía/métodos , Resultado del Tratamiento
3.
J Magn Reson Imaging ; 57(4): 1199-1211, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35861188

RESUMEN

BACKGROUND: Although endovascular aneurysmal repair (EVAR) is a preferred treatment for abdominal aortic aneurysm (AAA) owing to its low invasiveness, its impact on the local hemodynamics has not been fully assessed. PURPOSE: To elucidate how EVAR affects the local hemodynamics in terms of energy loss (EL). STUDY TYPE: Prospective single-arm study. FIELD STRENGTH/SEQUENCE: A 3.0 T/4D flow MRI using a phase-contrast three-dimensional cine-gradient-echo sequence. POPULATION: A total of 13 consecutive patients (median [interquartile range] age: 77.0 [73.0, 78.8] years, 11 male) scheduled for EVAR as an initial treatment for fusiform AAA. ASSESSMENT: 4D flow MRI covering the abdominal aorta and bilateral common iliac arteries and the corresponding stent-graft (SG) lumen was performed before and after EVAR. Plasma brain natriuretic peptide (BNP) was measured within 1 week before and 1 month after EVAR. The hemodynamic data, including mean velocity and the local EL, were compared pre-/post-EVAR. EL was correlated with AAA neck angle and with BNP. Patients were subdivided into deformed (N = 5) and undeformed SG subgroups (N = 8) and pre-/post-EVAR BNP compared in each. STATISTICS: Parametric or nonparametric methods. Spearman's rank correlation coefficients (r). The interobserver/intraobserver variabilities with Bland-Altman plots. A P value < 0.05 is considered significant. RESULTS: The mean velocity (cm/sec) at the AAA was five times greater after EVAR: 4.79 ± 0.32 vs. 0.91 ± 0.02. The total EL (mW) increased by 1.7 times after EVAR: 0.487 (0.420, 0.706) vs. 0.292 (0.192, 0.420). The total EL was proportional to the AAA neck angle pre-EVAR (r = 0.691) and post-EVAR (r = 0.718). BNP (pg/mL) was proportional to the total EL post-EVAR (r = 0.773). In the deformed SG group, EL (0.349 [0.261, 0.416]) increased 2.4-fold to 0.848 (0.597, 1.13), and the BNP 90.3 (53.6, 105) to 100 (67.2, 123) post-EVAR. CONCLUSION: The local EL showed a 1.7-fold increase after EVAR. The larger increase in the EL in the deformed SG group might be a potential concern for frail patients. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Humanos , Masculino , Imagen por Resonancia Magnética , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento , Femenino
4.
Eur J Vasc Endovasc Surg ; 66(1): 17-26, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36736616

RESUMEN

OBJECTIVE: To predict sac enlargement with type II endoleak (ELII) before endovascular aneurysm repair (EVAR) using four dimensional flow sensitive magnetic resonance imaging (4D flow MRI). METHODS: A single centre retrospective analysis of prospectively collected data was conducted. Patients with an abdominal aortic aneurysm (AAA) who underwent EVAR between 2013 and 2019 were included. Aortic branches occluded pre-EVAR, and patients with endoleaks other than ELII were excluded. The aortic branch diameter, peak flow velocity (PFVe), and amplitude of the dynamics of flow volume (AFV) were measured in each aortic branch pre-EVAR. Total flow volume per minute (TFV/min), defined as the sum of AFV/min, was calculated in each case. According to computed tomography findings one year post-EVAR, the aortic branches and patients were divided into patent vessel and occluded vessel groups and sac expanding and non-expanding groups. PFVe, AFV/min, and TFV/min were analysed via receiver operating characteristic curve analysis. RESULTS: The patent aortic branches pre-EVAR (69 inferior mesenteric arteries [IMAs]; 249 lumbar arteries [LAs]) of 100 patients were included. Patent IMAs (n = 14) and occluded IMAs (n = 55), patent LAs (n = 23) and occluded LAs (n = 226), and expanding (n = 9) and non-expanding (n = 91) groups were compared, respectively. No statistically significant difference was observed in branch diameters (IMA; patent, 2.5 ± 0.8 mm, occluded, 2.5 ± 0.8 mm, p < .78 and LA; patent, 1.5 ± 0.3 mm, occluded, 1.5 ± 0.4 mm, p < .35). PFVe (IMA; patent, 262.6 mm2/sec, occluded, 183.4 mm2/sec and LA; patent, 142.6 mm2/sec, occluded, 47.7 mm2/sec) and AFV/min (IMA; patent, 8.4 mL, occluded, 5.2 mL and LA; patent, 4.2 mL, occluded, 1.4 mL) were higher in the patent vessel group (p < .050). TFV/min was statistically significantly higher in the expanding group (24.1 mL/min) than in the non-expanding group (7.0 mL/min) (p < .010). CONCLUSION: Pre-EVAR haemodynamic analyses using 4D flow MRI were useful to detect aortic branches responsible for ELII and to predict AAA cases with sac enlargement. This analysis suggests a new strategy for pre-EVAR aortic branch embolisation.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/patología , Estudios Retrospectivos , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/cirugía , Aorta Abdominal/patología , Factores de Riesgo , Imagen por Resonancia Magnética , Resultado del Tratamiento
5.
Radiology ; 305(2): 341-349, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35852428

RESUMEN

Background Changing iodinated contrast media (ICM) may reduce the risk of recurrent ICM-induced hypersensitivity reactions in patients with a prior reaction. Purpose To perform a systematic review on the effectiveness of ICM change in comparison with no change to prevent recurrent ICM immediate hypersensitivity reactions. Materials and methods Multiple data bases were searched without language restriction between January 1990 and August 2021 to identify comparative studies of any design that included patients with a prior ICM hypersensitivity reaction to low-osmolality ICM and re-exposure to intravascular ICM. The methods used included a duplicate assessment of eligibility, double extraction of quantitative data, validity assessment, and random-effects meta-analysis. The primary outcome was the incidence of all-grade immediate recurrent hypersensitivity reactions. Secondary outcomes were the incidence of severe immediate recurrent hypersensitivity reactions and other adverse events associated with ICM change. Results Six retrospective observational studies at moderate to severe risk of bias assessed 7155 adult patients (4329 in the ICM change group and 2826 in the no-change group). Studies adopted nonstandardized switching methods, and the proportions of the ICM change group ranged between 19% (five of 27 examinations) and 80% (3104 of 3880 examinations). A Bayesian meta-analysis revealed that changing ICM was associated with a reduced risk of recurrent hypersensitivity reaction by 61% (risk ratio = 0.39; 95% credible interval [CrI]: 0.24, 0.58). The wide-ranging estimates of risk reduction were not explained by the risk of bias ratings, the event rates in the no-change group, the index-reaction severity, or the co-administered nonstandard premedication. Rare severe recurrent reactions (five studies with five events) precluded a conclusion (risk ratio = 0.34, favoring ICM change; CrI: 0.01, 3.74). Adverse events associated with ICM change were not reported. Conclusion In observational evidence of limited quality, iodinated contrast media (ICM)-change was associated with a reduced risk of recurrent immediate hypersensitivity reaction in patients with a prior ICM-induced hypersensitivity reaction. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by McDonald in this issue.


Asunto(s)
Hipersensibilidad Inmediata , Hipersensibilidad , Compuestos de Yodo , Adulto , Humanos , Medios de Contraste/efectos adversos , Estudios Retrospectivos , Teorema de Bayes , Compuestos de Yodo/efectos adversos , Hipersensibilidad Inmediata/inducido químicamente , Hipersensibilidad/etiología
6.
J Magn Reson Imaging ; 55(2): 323-335, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33140551

RESUMEN

BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE: Systematic consensus process using a modified Delphi method. POPULATION: Not applicable. SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts. RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Riñón , Imagen por Resonancia Magnética , Consenso , Técnica Delphi , Humanos , Estudios Multicéntricos como Asunto , Circulación Renal
7.
Europace ; 24(8): 1284-1290, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34919657

RESUMEN

AIMS: This study aimed to investigate the intraventricular blood flow pattern of patients with left bundle branch block (LBBB) using four-dimensional flow magnetic resonance imaging (4D-flow MRI). METHODS AND RESULTS: We performed 4D-flow MRI for 16 LBBB patients (LBBB group) and 16 propensity score-matched patients with a normal QRS duration (non-LBBB group). The energy loss (EL) in the left ventricle was evaluated. In both groups, blood flow from the mitral valve to the apex of the heart and left ventricular (LV) outflow tract during LV diastole were observed. Vortices were also observed in both groups. There were two patterns of vortices: unidirectional clockwise rotation and counterclockwise rotation taking place from the mid-diastole to the systole (reverse pattern). The reverse pattern was observed significantly more frequently in the LBBB group (LBBB 94% vs. non-LBBB 19%, P < 0.001). The interobserver agreement for the streamline analysis was good (kappa = 0.68). The maximum EL was significantly higher in the LBBB group [LBBB 12 (11-15) mW vs. non-LBBB 8.0 (6.2-9.7) mW, P < 0.001]. CONCLUSION: Left bundle branch block patients may suffer from inefficient LV haemodynamics reflected by non-physiological counterclockwise vortices and increased EL. Thus, the shape of the vortices and EL in the left ventricle can serve as markers of LV mechanical dyssynchrony in LBBB patients and could be investigated as predictors of response to cardiac resynchronization therapy.


Asunto(s)
Terapia de Resincronización Cardíaca , Disfunción Ventricular Izquierda , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Ventrículos Cardíacos , Humanos , Imagen por Resonancia Magnética , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda
8.
Radiol Med ; 127(11): 1181-1198, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36123520

RESUMEN

Thus far, ultrasound, CT, and 2D cine phase-contrast MRI has been adopted to evaluate blood flow and vascular morphology in the portal venous system; however, all these techniques have some shortcomings, such as limited field of view and difficulty in accurately evaluating blood flow. A new imaging technique, namely 3D cine phase-contrast (4D Flow) MRI, can acquire blood flow data of the entire abdomen at once and in a time-resolved manner, allowing visual, quantitative, and comprehensive assessment of blood flow in the portal venous system. In addition, a retrospective blood flow analysis, i.e., "retrospective flowmetry," is possible. Although the development of 4D Flow MRI for the portal system has been delayed compared to that for the arterial system owing to the lower flow velocity of the portal venous system and the presence of respiratory artifacts, several useful reports have recently been published as the technology has advanced. In the first part of this narrative review article, technical considerations of image acquisition and analysis methods of 4D Flow MRI for the portal venous system and the validations of their results are described. In the second part, the current clinical application of 4D Flow MRI for the portal venous system is reviewed.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Imagenología Tridimensional/métodos , Velocidad del Flujo Sanguíneo/fisiología , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Abdomen
9.
Hepatol Res ; 51(3): 343-349, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33434371

RESUMEN

Diagnosis and severity assessments of portosystemic shunts (PSSs) are important because the pathology sometimes results in severe hepatic encephalopathy, which can be treated almost completely by shunt embolization. At present, morphological assessment of PSS is performed mainly by computed tomography, and ultrasound is used for blood flow assessment. In two cases of PSS-related hepatic encephalopathy, we used time-resolved 3D cine phase-contrast (4D-flow) magnetic resonance imaging (MRI) to assess blood flow before and after shunt embolization. Before the intervention, blood flow in the main trunk of the superior mesenteric vein was mostly hepatofugal. However, post-interventional 4D-flow MRI revealed hepatopetal superior mesenteric vein flow with significantly increased portal vein blood flow. 4D-flow MRI is an ideal adjunct to Doppler ultrasonography, allowing for objective and visual assessment of morphology and blood flow of the portal venous system, including PSSs, and is useful in determining the indications for, and outcome of, PSS embolization.

10.
Radiol Med ; 125(9): 838-850, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32671554

RESUMEN

4D Flow is an emerging MR technique enabling three-dimensional and cardiac phase-resolved flowmetry with ECG-gated phase-contrast MRI that increased the speed of data acquisitions, accuracy and robustness. The method is promoting researches in areas that have not been fully addressed before in the cardiovascular system, such as flowmetry of the bloodstream across the valves, within the heart chambers, complexed flow dynamics such as vortex, helical or retrograde. Wall shear stress and other potential biomarkers derived from 4D Flow are known to be related to vascular wall diseases such as atherosclerosis. In this review, fundamental concepts of 4D Flow technique and post-processing, benefits and limitations as well as its clinical applications are discussed, and the importance of quality control and validation of the method is emphasized. New ideas inspired by 4D Flow can help clinicians and MR scientists further understand the role of flow dynamics in health sciences, diseases and various aspects of cardiovascular physiology.


Asunto(s)
Circulación Coronaria/fisiología , Imagen por Resonancia Cinemagnética/métodos , Velocidad del Flujo Sanguíneo , Electrocardiografía/métodos , Humanos , Hidrodinámica , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Flujo Sanguíneo Regional/fisiología , Resistencia al Corte/fisiología
11.
J Vasc Surg ; 70(1): 107-116.e1, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30792053

RESUMEN

OBJECTIVE: The objective of this study was to investigate the hemodynamic parameters of type II endoleaks (T2ELs) to predict sac expansion using four-dimensional flow-sensitive magnetic resonance imaging (4D-flow MRI) analysis. METHODS: Patients who underwent endovascular aneurysm repair (EVAR) and were diagnosed with a T2EL were included in the study. Using 4D-flow MRI at 7 days, the peak flow velocity and amplitude of dynamics of blood flow per minute were measured in each T2EL vessel. The peak flow velocity was defined as the maximum of the absolute value of the blood flow velocity. The amplitude of dynamics of blood flow in the tributary arteries was defined as the sum of the absolute values of the inflow and outflow volume in each vessel. The amplitude of dynamics of blood flow in the tributary arteries per sac was calculated in each sac. The aneurysm sac diameter was measured by computed tomography (CT) at 1 year. The patients were divided into two groups according to the presence or absence of sac expansion. RESULTS: Of 155 patients who underwent EVAR, both CT angiography and 4D-flow MRI were performed in 107 patients at 7 days after EVAR. Among them, 39 (36.4%) were found to have a T2EL, of whom 28 were re-evaluated with CT angiography and 4D-flow at 1 year; 7 patients had expanding sacs (expanding group), whereas 21 had nonexpanding sacs (not-expanding group). At 7 days, 28 patients had 80 T2EL vessels detected by 4D-flow MRI, of which 39 vessels (48.8%) had stopped flowing at 1 year (transient vessels); 41 vessels (51.3%) had sustained flow (persistent vessels). The persistent vessels had significantly larger peak flow velocity and amplitude of dynamics of blood flow. The comprehensive analysis of T2EL vessels per sac identified that the amplitude of dynamics of blood flow in the tributary arteries per sac was significantly higher in the expanding group than in the not-expanding group. A receiver operating characteristic curve analysis revealed that the sensitivity and specificity of sac enlargement at a cutoff value of 3750 mm3/min were 85.7% and 76.2%, respectively. CONCLUSIONS: The fate of aneurysm sacs with T2ELs after EVAR has remained difficult to predict. A comprehensive analysis of concurrent multiple T2EL vessels using 4D-flow MRI analysis may enable prediction of the sac expansion after EVAR.


Asunto(s)
Aorta/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Hemodinámica , Imagen por Resonancia Magnética , Imagen de Perfusión/métodos , Anciano , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Velocidad del Flujo Sanguíneo , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Progresión de la Enfermedad , Endofuga/etiología , Endofuga/fisiopatología , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
13.
Neuroradiology ; 60(5): 545-555, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29520642

RESUMEN

PURPOSE: We performed computational fluid dynamics (CFD) for patients with and without paraclinoid internal carotid artery (ICA) aneurysms to evaluate the distribution of vascular biomarkers at the aneurysm initiation sites of the paraclinoid ICA. METHODS: This study included 35 patients who were followed up for aneurysms using 3D time of flight (TOF) magnetic resonance angiography (MRA) and 3D cine phase-contrast MR imaging. Fifteen affected ICAs were included in group A with the 15 unaffected contralateral ICAs in group B. Thirty-three out of 40 paraclinoid ICAs free of aneurysms and arteriosclerotic lesions were included in group C. We deleted the aneurysms in group A based on the 3D TOF MRA dataset. We performed CFD based on MR data set and obtained wall shear stress (WSS), its derivatives, and streamlines. We qualitatively evaluated their distributions at and near the intracranial aneurysm initiation site among three groups. We also calculated and compared the normalized highest (nh-) WSS and nh-spatial WSS gradient (SWSSG) around the paraclinoid ICA among three groups. RESULTS: High WSS and SWSSG distribution were observed at and near the aneurysm initiation site in group A. High WSS and SWSSG were also observed at similar locations in group B and group C. However, nh-WSS and nh-SWSSG were significantly higher in group A than in group C, and nh-SWSSG was significantly higher in group A than in group B. CONCLUSION: Our findings indicated that nh-WSS and nh-SWSSG were good biomarkers for aneurysm initiation in the paraclinoid ICA.


Asunto(s)
Biomarcadores/sangre , Arteria Carótida Interna , Hemorreología , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/fisiopatología , Angiografía por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad
14.
J Magn Reson Imaging ; 46(2): 595-603, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28152259

RESUMEN

PURPOSE: To assess the performance of four-dimensional phase-contrast vastly undersampled isotropic projection reconstruction (4D PC-VIPR) at 3.0T in depicting intrarenal arteries compared with computed tomography angiography (CTA), and its correlation with arterial flowmetry in comparison with Doppler ultrasonography (DUS). MATERIALS AND METHODS: In our prospective single-arm study, subjects were 25 patients who underwent renal transplant-related surgery at our hospital between July 2011 and June 2015. In the morphological study, depictions of renal artery branches delineated by magnetic resonance angiography (MRA)/4D PC-VIPR without gadolinium contrast agent were compared in seven living transplant recipients with the same kidney delineated by CTA in seven living transplant donors. In the flowmetric study, flow velocities in the renal (main stem), segmental, and interlobar arteries during systole and diastole were measured in 12 recipients using noncontrast MRA/4D PC-VIPR, and were compared with those obtained from DUS. RESULTS: Concerning MRA, average confidence levels of delineation rated by six observers for secondary to third level renal artery branches were 82.9-100% and for the fourth to fifth branches were 60.8-89.7% (average kappa value of 0.588 [95% confidence interval: 0.522-0.653]). Total flow velocities measured using 4D PC-VIPR and DUS demonstrated significant correlations during both systole and diastole with acceptable bias (r = 0.902; P < 0.001 in systole and r = 0.734; P < 0.001 in diastole). CONCLUSION: 4D PC-VIPR was useful in generating both morphological and hemodynamic information for evaluation of transplant intrarenal arteries without the need for contrast media. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:595-603.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Riñón/diagnóstico por imagen , Arteria Renal/diagnóstico por imagen , Insuficiencia Renal/diagnóstico por imagen , Ultrasonografía Doppler , Adulto , Anciano , Velocidad del Flujo Sanguíneo , Medios de Contraste/química , Femenino , Gadolinio/química , Hemodinámica , Humanos , Aumento de la Imagen , Interpretación de Imagen Asistida por Computador , Trasplante de Riñón , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Insuficiencia Renal/cirugía , Reproducibilidad de los Resultados , Factores de Tiempo , Tomografía Computarizada por Rayos X , Receptores de Trasplantes
15.
Heart Vessels ; 32(8): 1032-1044, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28444501

RESUMEN

Computational fluid dynamics (CFD) are the gold standard in studying blood flow dynamics. However, CFD results are dependent on the boundary conditions and the computation model. The purpose of this study was to validate CFD methods using comparison with actual measurements of the blood flow vector obtained with four-dimensional (4D) flow magnetic resonance imaging (MRI). 4D Flow MRI was performed on a healthy adult and a child with double-aortic arch. The aortic lumen was segmented to visualize the blood flow. The CFD analyses were performed for the same geometries based on three turbulent models: laminar, large eddy simulation (LES), and the renormalization group k-ε model (RNG k-ε). The flow-velocity vector components, namely the wall shear stress (WSS) and flow energy loss (EL), of the MRI and CFD results were compared. The flow rate of the MRI results was underestimated in small vessels, including the neck vessels. Spiral flow in the ascending aorta caused by the left ventricular twist was observed by MRI. Secondary flow distal to the aortic arch was well realized in both CFD and MRI. The average correlation coefficients of the velocity vector components of MRI and CFD for the child were the highest for the RNG k-ε model (0.530 in ascending aorta, 0.768 in the aortic arch, 0.584 in the descending aorta). The WSS and EL values of MRI were less than half of those of CFD, but the WSS distribution patterns were quite similar. The WSS and EL estimates were higher in RNG k-ε and LES than in the laminar model because of eddy viscosity. The CFD computation realized accurate flow distal to the aortic arch, and the WSS distribution was well simulated compared to actual measurement using 4D Flow MRI. However, the helical flow was not simulated in the ascending aorta. The accuracy was enhanced by using the turbulence model, and the RNG k-ε model showed the highest correlation with 4D Flow MRI.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología , Simulación por Computador , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Modelos Cardiovasculares , Estrés Mecánico , Aorta Torácica/fisiología , Femenino , Voluntarios Sanos , Humanos , Persona de Mediana Edad
16.
J Magn Reson Imaging ; 44(6): 1493-1503, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27185516

RESUMEN

PURPOSE: To examine how left ventricular (LV) volume and function affect flow dynamics by analyzing 3D intra-LV vortex features using 4D-Flow. MATERIALS AND METHODS: Twenty-one patients with preserved (LVEF > 60%) and 14 with impaired LV function (LVEF < 40%) underwent 4D-Flow (at 3T). RESULTS: In patients with preserved LV function, the intra-LV vortices developed in both the early and late diastolic phases. The shift of inflow vectors at the basal LV toward the posterior-lateral side of the LV and the mid-ventricular turn of inflow vectors toward the LV outflow could explain clearer vortex formation in the late diastolic phase. In patients with impaired LV function, the intra-LV vortices during the diastolic phase located at the more apical LV were larger and more spherically shaped. Both the distance to the vortex core and the vortex area correlated significantly with LV end-diastolic volume (r = 0.66 and 0.73), LVEF (r = -0.74 and -0.68), LV sphericity index (r = -0.60 and -0.65), and peak filling rate (r = -0.61 and -0.64), respectively (P < 0.01). The intra-LV vortices developed during the systolic phase in 10 cases. In those, some of the particles at the apical LV rotated within the LV, whereas in patients with preserved LV function, all of the particles were directed straight to the ascending aorta with accelerated flow velocity (256.8 ± 120.2 cm/s vs. 414.3 ± 88.2 cm/s, P < 0.01). CONCLUSION: Vortex formation during the diastolic phase may be critical for both LV filling and ejection. 4D-Flow showed the 3D alterations of intra-LV flow dynamics by LV dilatation and dysfunction in a noninvasive and comprehensive manner. J. Magn. Reson. Imaging 2016;44:1493-1503.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Adulto , Algoritmos , Velocidad del Flujo Sanguíneo , Técnicas de Imagen Cardíaca/métodos , Medios de Contraste , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
J Magn Reson Imaging ; 43(2): 384-90, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26149267

RESUMEN

PURPOSE: 1) To assess the usefulness of an elastic belt bracing the upper abdomen for reducing the miscalculated areas of the pancreas on 3.0T magnetic resonance elastography (MRE); 2) to test whether MRE can detect difference of stiffness between normal pancreas and the focal pancreatic diseases. MATERIALS AND METHODS: Using an initial eight normal volunteers, miscalculated areas were compared between MRE with the elastic belt and without the belt on 3.0T MRI. Then, using the belt, MRE of the normal pancreas was measured using 14 volunteers and 11 patients with focal pancreatic lesions. RESULTS: The median (95% confidence interval [CI]) percentages of correctly calculated areas were 57.4% (32.9-63.0) with the elastic belt and 35.3% (11.4-60.4) without the belt (P = 0.0078). The stiffness of each pancreatic segment of the normal volunteers (mean ± SE) was 2.37 ± 0.16 kPa for the head, 2.46 ± 0.17 kPa for the body, and 2.58 ± 0.26 kPa for the tail. The stiffness of seven pancreatic cancers was 6.06 ± 0.49 kPa, which was higher than the overall pancreatic stiffness of the normal volunteers (2.47 ± 0.11 kPa, P < 0.0001). Stiffness of the pancreatic lesions in the head of 6.03 ± 0.42 kPa, body of 5.57 ± 0.82 kPa, and tail of 5.9 ± 1.9 kPa were also higher than those of corresponding segments of the normal volunteers (P = 0.0011, 0.0029, and 0.029, respectively). CONCLUSION: With the elastic belt, miscalculation of the pancreatic stiffness was reduced. MRE showed differences of stiffness between normal pancreas and pancreatic lesions.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/instrumentación , Diagnóstico por Imagen de Elasticidad/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Páncreas/patología , Neoplasias Pancreáticas/patología , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Proyectos Piloto , Valores de Referencia , Reproducibilidad de los Resultados
18.
Circ J ; 80(8): 1715-25, 2016 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-27357219

RESUMEN

BACKGROUND: An endoleak is a common complication of endovascular abdominal aortic aneurysm repair (EVAR), and it can be associated with aneurysmal growth. This pilot study used 4-dimensional flow-sensitive magnetic resonance imaging (4D-flow) to assess the hemodynamics of different types of endoleaks (I-IV). METHODS AND RESULTS: Magnetic resonance angiography, 4D-flow, and computed tomography angiography (CTA) were performed in 31 patients after nitinol-based stent-graft deployment. With 4D-flow, the 3D streamlines of endoleaks appear as integrated traces along the instantaneous velocity vector field that are color-coded according to the local velocity magnitude of the leak. The 4D-flow analysis identified endoleaks in 18 patients (58.1%), whereas CTA identified endoleaks in 13 patients (41.9%). The 4D-flow analysis created a characteristic image of each type of endoleak. Among patients with endoleaks, 4D-flow identified concomitant multiple endoleaks in 7 (39%) patients, and it further differentiated type II endoleaks from type IIa endoleaks (to-and-fro biphasic flow pattern from a branch vessel) and from type IIb endoleaks (monophasic flow pattern with a connection between the inflow and outflow branches). CONCLUSIONS: The 4D-flow analysis was more sensitive than CTA for detecting an endoleak, and it could subclassify type II endoleaks. In addition, 4D-flow differentiated between concomitant endoleak types in a single patient. (Circ J 2016; 80: 1715-1725).


Asunto(s)
Aneurisma de la Aorta Abdominal , Endofuga , Angiografía por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/cirugía , Aortografía/métodos , Velocidad del Flujo Sanguíneo , Endofuga/diagnóstico por imagen , Endofuga/fisiopatología , Femenino , Humanos , Masculino
19.
J Magn Reson Imaging ; 41(1): 165-8, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24615925

RESUMEN

Renovascular hypertension (RVH) is an important cause of hypertension in children. It is essential to assess the hemodynamics of RVH lesions in detail. We herein report the case of a 9-year-old female with RVH caused by left renal artery stenosis in which the hemodynamics of the lesions were assessed with time-resolved three-dimensional cine phase-contrast MRI (3D cine PC MRI) with a vastly undersampled 3D radial projection imaging trajectory before and after percutaneous transluminal renal angioplasty (PTRA). The utility of 3D cine PC MRA for diagnosing RVH and evaluating the renal blood flow pre- and post-PTRA is presented.


Asunto(s)
Hemodinámica/fisiología , Hipertensión Renovascular/fisiopatología , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Angioplastia de Balón/métodos , Niño , Femenino , Humanos , Hipertensión Renovascular/terapia , Resultado del Tratamiento
20.
J Neurooncol ; 121(3): 549-56, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25479828

RESUMEN

Pseudo-continuous arterial spin labeling (PCASL) can measure tumor blood flow (TBF) reliably. We investigated meningioma TBF using PCASL and assessed for any correlation with histopathological microvascular density (MVD) and the World Health Organization (WHO) classification. Conventional MRI with contrast T1-weighted images and PCASL were acquired with a 3 T scanner before surgery in 25 consecutive patients with meningiomas. Using the PCASL perfusion map, the mean and maximum TBF were calculated from regions of interest placed in the largest cross-sectional plane of each tumor. Tissue sections from 16 patients were stained with CD31 to evaluate MVD and were assigned a WHO classification. The TBFs were statistically compared with MVD and the histopathological meningioma subtypes. There were 16 meningothelial meningiomas, four angiomatous meningiomas, two fibrous meningiomas, one transitional meningioma, and two atypical meningiomas. We observed significant correlation between MVD and both mean and maximum TBF (p < 0.05). The mean and maximum TBF ((mean)TBF, (max)TBF) in angiomatous meningiomas are significantly higher than that in non-angiomatous meningiomas (p < 0.05). PCASL is useful in assessing meningioma vascularity, and in differentiating angiomatous meningiomas from non-angiomatous meningiomas.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias Meníngeas/irrigación sanguínea , Neoplasias Meníngeas/patología , Meningioma/irrigación sanguínea , Meningioma/patología , Adulto , Anciano , Anciano de 80 o más Años , Circulación Cerebrovascular/fisiología , Estudios Transversales , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Marcadores de Spin
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA