Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circulation ; 148(21): 1665-1676, 2023 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-37638968

RESUMEN

BACKGROUND: The optimal duration of anticoagulation therapy for isolated distal deep vein thrombosis in patients with cancer is clinically relevant, but the evidence is lacking. The prolonged anticoagulation therapy could have a potential benefit for prevention of thrombotic events; however, it could also increase the risk of bleeding. METHODS: In a multicenter, open-label, adjudicator-blinded, randomized clinical trial at 60 institutions in Japan, we randomly assigned patients with cancer with isolated distal deep vein thrombosis, in a 1-to-1 ratio, to receive either a 12-month or 3-month edoxaban treatment. The primary end point was a composite of a symptomatic recurrent venous thromboembolism (VTE) or VTE-related death at 12 months. The major secondary end point was major bleeding at 12 months, according to the criteria of the International Society on Thrombosis and Haemostasis. The primary hypothesis was that a 12-month edoxaban treatment was superior to a 3-month edoxaban treatment with respect to the primary end point. RESULTS: From April 2019 through June 2022, 604 patients were randomized, and after excluding 3 patients who withdrew consent, 601 patients were included in the intention-to-treat population: 296 patients in the 12-month edoxaban group and 305 patients in the 3-month edoxaban group. The mean age was 70.8 years, 28% of the patients were men, and 20% of the patients had symptoms of deep vein thrombosis at baseline. The primary end point of a symptomatic recurrent VTE event or VTE-related death occurred in 3 of the 296 patients (1.0%) in the 12-month edoxaban group and in 22 of the 305 patients (7.2%) in the 3-month edoxaban group (odds ratio, 0.13; 95% CI, 0.03-0.44). The major secondary end point of major bleeding occurred in 28 of the 296 patients (9.5%) in the 12-month edoxaban group and in 22 of the 305 patients (7.2%) in the 3-month edoxaban group (odds ratio, 1.34; 95% CI, 0.75-2.41). The prespecified subgroups did not affect the estimates on the primary end point. CONCLUSIONS: In patients with cancer with isolated distal deep vein thrombosis, 12 months was superior to 3 months for an edoxaban treatment with respect to the composite outcome of a symptomatic recurrent VTE or VTE-related death. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03895502.


Asunto(s)
Neoplasias , Trombosis , Tromboembolia Venosa , Trombosis de la Vena , Masculino , Humanos , Anciano , Femenino , Anticoagulantes/efectos adversos , Tromboembolia Venosa/tratamiento farmacológico , Tromboembolia Venosa/complicaciones , Hemorragia/complicaciones , Trombosis/complicaciones , Trombosis de la Vena/complicaciones , Neoplasias/complicaciones , Neoplasias/tratamiento farmacológico
2.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37438144

RESUMEN

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Angiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Estimación de Kaplan-Meier , Riñón/diagnóstico por imagen , Resultado del Tratamiento
3.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38008428

RESUMEN

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Modelos de Riesgos Proporcionales , Cateterismo Cardíaco
4.
Circ J ; 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38462535

RESUMEN

BACKGROUND: Patients with appropriately selected low-risk pulmonary embolism (PE) can be treated at home, although it has been controversial whether applies to patients with cancer, who are considered not to be at low risk.Methods and Results: The current predetermined companion report from the ONCO PE trial evaluated the 3-month clinical outcomes of patients with home treatment and those with in-hospital treatment. The ONCO PE trial was a multicenter, randomized clinical trial among 32 institutions in Japan investigating the optimal duration of rivaroxaban treatment in cancer-associated PE patients with a score of 1 using the simplified version of the Pulmonary Embolism Severity Index (sPESI). Among 178 study patients, there were 66 (37%) in the home treatment group and 112 (63%) in the in-hospital treatment group. The primary endpoint of a composite of PE-related death, recurrent venous thromboembolism (VTE) and major bleeding occurred in 3 patients (4.6% [0.0-9.6%]) in the home treatment group and in 2 patients (1.8% [0.0-4.3%]) in the in-hospital treatment group. In the home treatment group, there were no cases of PE-related death or recurrent VTE, but major bleeding occurred in 3 patients (4.6% [0.0-9.6%]), and 2 patients (3.0% [0.0-7.2%]) required hospitalization due to bleeding events. CONCLUSIONS: Active cancer patients with PE of sPESI score=1 could be potential candidates for home treatment.

5.
Circ J ; 87(4): 517-524, 2023 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-36624061

RESUMEN

BACKGROUND: Transesophageal echocardiography (TEE) has been used for percutaneous atrial septal defect (ASD) closure, with intracardiac echocardiography (ICE) guidance recently being introduced.Methods and Results: The Japanese Structural Heart Disease Registry was established by the Japanese Association of Cardiovascular Intervention and Therapeutics. This study analyzed data from the Registry for 2,859 consecutive cases undergoing percutaneous ASD closure between January 2015 and December 2020. ASD closure was performed under ICE guidance (n=519; 18.2%), TEE guidance (n=1,428; 49.9%), or TEE plus ICE guidance ("Both"; n=900 cases; 31.5%). The success rates were similar in the TEE, ICE, and both groups (99.0%, 99.2%, vs. 98.0%, respectively; P=0.054), as were complication rates (1.2%, 0.5%, vs. 2.1%, respectively; P=0.24). In the TEE and Both groups, 92.4% and 79.6% of patients required general anesthesia, compared with only 2.9% of patients in the ICE group (P<0.001). Fluoroscopic time was longer in the ICE and Both groups than in the TEE group (median [interquartile range] 19 [14-28] and 21 [13-30] vs. 12 [8-19] min, respectively; P<0.001). Rim deficiency and larger defect diameter were inversely related, whereas hospital volume was positively related to ICE guidance. CONCLUSIONS: Percutaneous transcatheter ASD closure was as feasible under ICE as under TEE guidance. ICE guidance is used for less challenging cases in high-volume centers in Japan.


Asunto(s)
Cateterismo Cardíaco , Defectos del Tabique Interatrial , Humanos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Ecocardiografía Transesofágica/métodos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía , Fluoroscopía
6.
Circ J ; 85(7): 1068-1075, 2021 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-33762527

RESUMEN

BACKGROUND: Although diastolic flow reversal (DFR) in the descending aorta, assessed via transesophageal echocardiography (TEE), is a simple and easy indicator for evaluating aortic regurgitation, the association between DFR pattern and clinical outcomes following transcatheter aortic valve implantation (TAVI) is unclear. The purpose of this study was to evaluate the effect of DFR patterns on clinical outcomes following TAVI.Methods and Results:Two-hundred and eleven patients (mean age, 83.6±5.7 years; 69% female) who underwent TAVI were retrospectively assessed via intraprocedural TEE. DFR was evaluated using pulsed-wave Doppler in the descending aorta before and after TAVI. The primary endpoint was major adverse cardio-cerebrovascular events (MACCEs). Although only 7 patients (3.3%) had moderate or severe paravalvular leak, as assessed by color Doppler echocardiography, holo-DFR (HDFR) was observed in 33 patients (16.0%) after TAVI. MACCEs occurred in 40 patients during the median follow up of 282 days (interquartile range: 160-478 days). The estimated cumulative MACCE-free survival at 1 year was significantly lower in patients with HDFR than in those without HDFR. A Cox proportional hazards analysis revealed that HDFR after TAVI was independently associated with MACCEs. CONCLUSIONS: HDFR was associated with an increased risk of MACCEs after TAVI. DFR evaluated by intraprocedural echocardiography could serve as a simple and easy method for predicting clinical outcomes.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
Scand Cardiovasc J ; 55(5): 270-278, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34291701

RESUMEN

Background. Moderate aortic stenosis (AS) increases left ventricular afterload and results in unfavorable outcomes in patients with reduced left ventricular ejection fraction (LVEF). Velocity ratio (VR) may be appropriate for the evaluation of aortic valve (AV) hemodynamics because of the low dependence on flow. Therefore, this study investigated the usefulness of VR on the clinical outcomes of such patients. Method. Clinical data of patients with moderate AS (AV area, 0.60-0.85 cm2/m2; peak AV velocity, 2.0-4.0 m/s) and reduced LVEF (LVEF 20-50%) were analyzed during 2010-2018. VR was calculated as peak left ventricular outflow tract velocity/peak AV velocity. The primary endpoint included all-cause death, heart failure hospitalization, and AV replacement. Results. In total, 104 patients (mean age, 75.9 ± 7.0 years; 62.5% men) were included. LVEF was 39.5% ± 7.8%. The AV area was 0.72 ± 0.08 cm2/m2, peak AV velocity was 2.59 ± 0.40 m/s, and VR was 0.30 ± 0.07. The follow-up period was 1.7 (0.5-3.5) years. Kaplan-Meier estimates for the endpoint were 59.9% at 3 years. Multivariable analysis revealed that VR (hazard ratio, 0.947; 95% confidence interval, 0.905-0.990; p = .018) was significantly related to this endpoint. Patients with a VR <0.25 had significantly higher incidence rates of the endpoint than those with a VR ≥0.25 (85.6% versus 47.8% at 3 years; p < .001). Conclusions. Patients with moderate AS and reduced LVEF have unfavorable clinical outcomes, particularly those with low VR.


Asunto(s)
Estenosis de la Válvula Aórtica , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/fisiopatología , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Humanos , Masculino , Gravedad del Paciente , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología
8.
Heart Vessels ; 36(7): 1072-1079, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33484292

RESUMEN

Preoperative frailty diminishes the potential for functional recovery after transcatheter aortic valve implantation (TAVI). However, perioperative changes in physical status and their impact on prognosis after TAVI have not previously been reported. Therefore, this study aimed to investigate whether perioperative changes in physical function affect prognosis in patients undergoing TAVI. We retrospectively reviewed 257 patients who underwent TAVI. The Short Physical Performance Battery (SPPB), an objective physical status assessment tool, was evaluated pre- and post-TAVI. Patients were divided into two groups: (i) patients whose SPPB score declined in the perioperative period (the decline group) and (ii) patients whose SPPB score did not decline in the perioperative period (the non-decline group). The primary endpoint was unplanned hospitalization owing to heart failure or cardiovascular death following TAVI. The mean follow-up period was 385 ± 151 days, mean age was 83.2 ± 5.8 years, and 67% of the patients were women. Sixteen patients required readmission owing to heart failure, and seven experienced cardiovascular-related death. Kaplan-Meier analysis revealed that the event-free rate was significantly lower in the decline group (log-rank, p = 0.006). A stepwise multivariate logistic regression analysis showed that a perioperative change in SPPB was significantly associated with primary endpoints (odds ratio, 1.51; 95% confidence interval, 1.12-2.04). Perioperative change in physical function was an independent risk factor for heart failure, hospitalization, or cardiovascular death following TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Ejercicio Físico/fisiología , Fragilidad/fisiopatología , Medición de Riesgo/métodos , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/epidemiología , Femenino , Estudios de Seguimiento , Fragilidad/epidemiología , Fragilidad/etiología , Humanos , Incidencia , Japón/epidemiología , Masculino , Readmisión del Paciente/tendencias , Periodo Perioperatorio , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
9.
Circ J ; 84(11): 2015-2022, 2020 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-32999143

RESUMEN

BACKGROUND: Asian patients have smaller aortic annuli. Although 20-mm balloon-expandable (BE) transcatheter heart valves (THV) are manufactured for transcatheter aortic valve implantation (TAVI) in these cases, the supra-annular design of self-expandable (SE) THV is considered more suitable; however, real-world comparative data are scarce.Methods and Results:Consecutive TAVI cases (n=330) in a single Japanese center were reviewed. Based on the cutoff for the new-generation 20-/23-mm BE-THV, a small aortic annulus was defined as <330 mm2. A considerable number of patients had small annuli: 49/302 (16%). Of these, 33 BE-THV and 13 SE-THV using new-generation valves were compared. Although the SE-THV group had smaller annulus area (median 297 (interquartile range, 280-313) vs. 309 (303-323) mm2(P=0.022)), it had more favorable post-procedural parameters; for SE-THV and BE-THV, respectively, effective orifice area (EOA), 1.5 (1.3-1.6) vs. 1.1 cm2(0.9-1.3) (P=0.002); mean pressure gradient, 7.6 (5.6-11.0) vs. 14.2 mmHg (11.2-18.8) (P=0.001); and peak velocity, 1.8 (1.6-2.4) vs. 2.7 m/s (2.3-3.1) (P=0.001). Although new left bundle branch block was higher with SE-THV (24% and 62%, P=0.02), patient-prosthesis mismatch (PPM) ≥ moderate (indexed EOA <0.85 cm2/m2) was significantly less with SE-THV than with BE-THV (8% vs. 55%; P=0.04). Hemodynamic findings were consistent up to 1 year. CONCLUSIONS: Small annuli are often seen in Asian patients, for whom SE-THV implantation results in favorable hemodynamics with less PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Humanos , Diseño de Prótesis , Resultado del Tratamiento
10.
Circ J ; 84(12): 2296-2301, 2020 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-33055458

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment for symptomatic patients with severe aortic stenosis (AS). Sometimes patients with severe AS taking immunosuppressants are encountered. The effect of immunosuppressive therapy on clinical outcomes in patients with AS following TAVI were investigated.Methods and Results:In total, 282 consecutive patients with severe AS who underwent transfemoral TAVI from January 2016 to December 2018 at St. Marianna University School of Medicine were reviewed. They were divided into 2 groups: the immunosuppressants group (IM group) in which patients continually used immunosuppressive drugs (n=22) and the non-immunosuppressants group (non-IM group) (n=260). The composite endpoints of a major adverse cardiovascular and cerebrovascular event (MACCE) defined as non-lethal myocardial infarction, unstable angina pectoris, heart failure requiring hospitalization, stroke, and cardiovascular death were evaluated. There were no differences in the incidence of vascular access complications (32% vs. 20%, P=0.143) and the rate of procedure success (100% vs. 93%, P=0.377) between the IM and non-IM groups. During the median follow-up period of 567 (16-1,312) days after the TAVI procedure, there were no significant differences between the IM and non-IM groups in the incidence of infectious complications (14% vs. 9%, P=0.442) or MACCE (18% vs. 20%, respectively; P=0.845). CONCLUSIONS: The use of IM after TAVI is not associated with increased vascular access complications or mid-term MACCE in patients with severe AS treated with TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Inmunosupresores , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Terapia de Inmunosupresión , Inmunosupresores/efectos adversos , Factores de Riesgo , Resultado del Tratamiento
11.
Circ J ; 84(6): 1012-1019, 2020 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-32224577

RESUMEN

BACKGROUND: Although left bundle-branch block (LBBB) is a known conduction disorder that occurs after transcatheter aortic valve implantation (TAVI), its clinical impact in the Japanese population remains unclear.Methods and Results:Of the 298 consecutive patients who underwent TAVI from January 2016 to December 2018 in a high-volume center in Japan, 68 with prior or periprocedural permanent pacemaker implantation (PPI), pre-existing LBBB, death during hospitalization, aborted procedure, or incomplete data were excluded. Among the final cohort of 230 patients, new-onset LBBB occurred in 90 (39%) after TAVI and persisted at 1-month follow up in 29 patients (13%; persistent new-onset LBBB, PN-LBBB). On multivariable analysis, self-expandable valve (SEV) use was found to be the only predictor of PN-LBBB (odds ratio: 4.39, 95% confidence interval: 1.69-11.41, P=0.002). There were no differences between patients with and without PN-LBBB in terms of overall mortality (18.8% vs. 26.0%, log-rank P=0.90) or need for late PPI (4.0% vs. 3.5%, log-rank P=0.74), yet there was an increased re-admission rate for heart failure (HF) in the PN-LBBB group (15.6% vs. 8.0%, log-rank P=0.046) at a median follow up of 431 (interquartile range, 271-733) days. CONCLUSIONS: PN-LBBB following TAVI was not associated with mortality or late PPI, but with a higher incidence of HF-related re-hospitalization at the mid-term follow up.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/epidemiología , Hospitales de Alto Volumen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/mortalidad , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial , Femenino , Insuficiencia Cardíaca/epidemiología , Humanos , Incidencia , Japón/epidemiología , Masculino , Readmisión del Paciente , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Heart Vessels ; 32(6): 777-779, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28289840

RESUMEN

An expandable polytetrafluoroethylene (ePTFE) covered stent is generally employed to seal coronary artery perforation. The frequency of ePTFE covered stent use is relatively low; thus, only a handful of studies have reported neointimal coverage and endothelialization inside the deployed ePTFE and clinical time course after ePTFE implantation. This case report presents a 78-year-old man treated with an ePTFE covered stent when he suffered from coronary artery perforation after the implantation of two everolimus eluting stents in the left anterior descending artery. Follow-up coronary angiography 9 months after ePTFE covered stent implantation depicted favorable stent patency. Optical coherence tomography showed thin and uneven stent strut coverage at the culprit. Angioscopy also depicted partial white-coated coverage and stent strut exposure. The outcome of this case suggested that long-term dual antiplatelet therapy should be prescribed for preventing thrombosis after ePTFE covered stent implantation.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Vasos Coronarios/lesiones , Stents Liberadores de Fármacos/efectos adversos , Neointima/diagnóstico por imagen , Anciano , Angioplastia Coronaria con Balón/instrumentación , Angioscopía , Angiografía Coronaria , Vasos Coronarios/cirugía , Everolimus/administración & dosificación , Humanos , Masculino , Infarto del Miocardio/cirugía , Diseño de Prótesis , Tomografía de Coherencia Óptica
13.
Circ J ; 79(4): 889-91, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25739720

RESUMEN

BACKGROUND: The Pulmonary Embolism Severity Index (PESI) and simplified PESI (sPESI) have not been fully evaluated in Japan, so the present study aimed to evaluate these risk stratification models in the prediction of mortality of affected patients in Japan. METHODS AND RESULTS: We retrospectively analysed 302 PE patients (63.9±17.2 years of age; 42.4% male) from January 2011 to December 2012 using data from the Tokyo CCU Network. The areas under the receiver-operating characteristic curves were 0.92 (95% confidence interval (CI): 0.88-0.97) for the PESI and 0.88 (95% CI: 0.77-0.98) for the sPESI. CONCLUSIONS: Both scores can be used to predict PE mortality in Japan.


Asunto(s)
Modelos Cardiovasculares , Embolia Pulmonar/mortalidad , Índice de Severidad de la Enfermedad , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo
14.
Heart Vessels ; 29(3): 417-21, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23893269

RESUMEN

A 47-year-old man underwent slow pathway ablation for slow-fast atrioventricular nodal reentrant tachycardia. Following the procedure, he felt palpitations while swallowing, and swallowing-induced atrial tachycardia was diagnosed. Swallowing-induced atrial tachycardia arose from the right atrium-superior vena cava junction and was cured by catheter ablation. After the procedure, the patient's heart rate variability changed significantly, indicating suppression of parasympathetic nerve activity. In this case, swallowing-induced atrial tachycardia was related to the vagal nerve reflex. Analysis of heart rate variability may be helpful in elucidating the mechanism of swallowing-induced atrial tachycardia.


Asunto(s)
Ablación por Catéter , Deglución , Frecuencia Cardíaca , Taquicardia Supraventricular/cirugía , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Reflejo , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento , Nervio Vago/fisiopatología
15.
Cardiovasc Revasc Med ; 58: 68-76, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37500393

RESUMEN

BACKGROUND: Aortic stenosis (AS) and chronic kidney disease (CKD) can coexist. Repeat exposure to contrast media in patients undergoing transcatheter aortic valve implantation (TAVI) has latent mortality risks and increased risk for acute kidney injury. We aimed to assess our "zero-contrast TAVI" protocol for patients with advanced CKD. METHODS: Consecutive patients with severe AS who underwent TAVI at a single center registry were enrolled. Zero-contrast TAVI group included patients who underwent TAVI without contrast and who had an estimated glomerular filtration rate <30 mL/min/1.73 m2. Conventional TAVI group included patients who underwent the regular TAVI procedure. Patients using balloon-expandable valves via transfemoral approach were analyzed. Baseline clinical and procedural characteristics and clinical outcomes were compared between two groups. The primary outcome was early safety as defined by Valve Academic Research Consortium Criteria. Secondary outcomes included the presence of severe prosthesis-patient mismatch, moderate or greater perivalvular leakage, and requirement for new dialysis (within 3 months). RESULTS: A total of 520 patients were analyzed. Among these, 32 (6 %) underwent zero-contrast TAVI and 488 (94 %) conventional TAVI. In the zero-contrast TAVI group, 12 patients (37.5 %) had to use 20.7 (11.0-31.2) mL of contrast media. There were no significant differences in the primary and secondary outcomes between zero-contrast TAVI and conventional TAVI groups (78.1 % vs. 86.8 %, P = 0.184 and 9.4 % vs. 8.1 %, P = 0.738 for the primary and secondary outcomes, respectively). CONCLUSIONS: Zero-contrast TAVI is feasible, safe, and effective in patients with AS and stage 4 CKD.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estudios de Factibilidad , Medios de Contraste/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/terapia , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento
16.
Cardiovasc Interv Ther ; 39(1): 74-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37938532

RESUMEN

The safety and feasibility are still not well known for exercise-induced mitral regurgitation (MR). This study is aimed to assess and compare the hemodynamic and symptomatic changes in patients with significant secondary MR during exercise stress echocardiography (ESE) before and after transcatheter edge-to-edge repair (TEER). The study included a total of 15 patients with secondary MR who underwent ESE before and after TEER using the MitraClip system (Abbott, Abbott Park, IL, USA). Echocardiographic data of ESE were collected both before the procedure and during the follow-up visit at 3 months. During the one-year postoperative observation period, the rate of readmission due to heart failure was 13% (n = 2), with no recorded fatalities. Although no significant differences of ESE data were observed in exercise-induced pulmonary hypertension or cardiac output before and after the repair, the severity of MR was significantly improved after the procedure, both at rest (2 [2-3] vs. 1 [1-2], p = 0.0125) and during ESE (3 [3-3] vs. 1 [1-1], p < 0.0001). Furthermore, the New York Heart Association Functional Classification was improved (3 [3-3] vs. 1 [1-1], p < 0.0001) after treatment. For a supplemental analysis, MR during ESE was significantly improved not only in cases with atrial secondary MR but also in ventricular secondary MR. Transcatheter edge-to-edge repair for exercise-induced MR resulted in a significant improvement in postoperative MR severity and subjective symptoms. These results are novel, as they have not been extensively reported previously, particularly among Japanese patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Ecocardiografía de Estrés , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco
17.
Am J Cardiol ; 210: 259-265, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37875233

RESUMEN

Aortic stenosis is a prevalent valvular heart disease, especially in the older people. They often coexist with other co-morbidities, and noncardiac surgery carries a higher risk because of the underlying valve condition. Despite the growing concern about the safety and optimal management of noncardiac surgery post-transcatheter aortic valve replacement (TAVR), there is limited evidence on this matter. This study aims to assess the clinical outcomes of noncardiac surgeries after TAVR. This retrospective study included 718 patients who underwent TAVR. Of these, 36 patients underwent noncardiac surgery after TAVR. The primary end point was the incidence of cardiovascular adverse events post-TAVR and the secondary end point was the incidence of structural valve deterioration. Composite end points included disabling stroke, heart failure requiring hospitalization, and cardiac death as defined by Valve Academic Research Consortium 3. Most of these surgeries were orthopedic and classified as intermediate risk. All noncardiac surgeries were performed without perioperative adverse events. There was no observed structural valve deterioration, and the incidence of composite end points did not significantly differ between the surgical and nonsurgical groups during the follow-up period. Noncardiac surgery after TAVR can be performed safely and does not have a negative impact on prognosis. Further studies are warranted to determine the optimal strategy for noncardiac surgery after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Prevalencia , Factores de Riesgo , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
19.
Thromb Res ; 235: 107-115, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38335565

RESUMEN

BACKGROUND: The multicenter, open-label, randomized clinical trial ONCO DVT compared 3-month and 12-month edoxaban treatment regimens for isolated distal deep vein thrombosis (DVT) and suggested potential benefits of prolonged edoxaban treatment in terms of thrombotic risk. However, the risk-benefit balance of prolonged edoxaban treatment in patients with renal function remains unclear. OBJECTIVES: To compare the safety and efficacy of 3-month and 12-month edoxaban treatment regimens in patients with cancer-associated isolated distal DVT and different renal functions. METHODS: This pre-specified subgroup analysis of the ONCO DVT study included 601 patients divided into subgroups according to renal function using a 50 mL/min creatinine clearance (Ccr) cutoff. The primary endpoint was symptomatic recurrent venous thromboembolism (VTE) and VTE-related death at 12 months and the major secondary endpoint was major bleeding at 12 months. RESULTS: Among the 601 patients, 131 (21.8 %) comprised the renal dysfunction subgroup. The primary endpoint occurred in 6 (9.7 %) and 1 (1.4 %) patients in the 3-month and 12-month edoxaban groups in the renal dysfunction subgroup, respectively, and in 16 (6.6 %) and 2 (0.9 %) patients in the no renal dysfunction subgroup, respectively. The major secondary endpoint occurred in 9 (14.5 %) and 7 (10.1 %) patients in the 12-month and 3-month edoxaban groups in the renal dysfunction subgroup, and in 13 (5.3 %) and 21 (9.3 %) patients in the no renal dysfunction subgroup, respectively. CONCLUSIONS: A 12-month edoxaban regiment was superior to a 3-month treatment in terms of thrombotic risk irrespective of renal function. A higher bleeding risk was not identified in patients with renal dysfunction who received prolonged edoxaban treatment.


Asunto(s)
Enfermedades Renales , Neoplasias , Piridinas , Tiazoles , Tromboembolia Venosa , Trombosis de la Vena , Humanos , Neoplasias/complicaciones , Trombosis de la Vena/tratamiento farmacológico , Trombosis de la Vena/etiología , Riñón
20.
Artículo en Inglés | MEDLINE | ID: mdl-38650055

RESUMEN

BACKGROUND: The ONCO DVT study revealed the superiority of 12-month relative to 3-month edoxaban treatment for cancer-associated isolated distal deep vein thrombosis (DVT) regarding the thrombotic risk. METHODS: In this pre-specified subgroup analysis of the ONCO DVT study, we stratified the patients into those with a standard edoxaban dose (60 mg/day; N=151) and those with a reduced edoxaban dose (30 mg/day; N=450) and evaluated the clinical outcomes for the 12-month and 3-month treatments. RESULTS: The cumulative 12-month incidence of symptomatic recurrent venous thromboembolism was lower in the 12-month than 3-month group for both the 60 mg (1.3% vs. 11.6%, P=0.02; odds ratio [OR], 0.12; 95% CI, 0.01-0.97) and 30 mg (1.1% vs. 7.6%, P=0.002; OR, 0.14; 95% CI, 0.03-0.60) edoxaban subgroups, which was consistent across the edoxaban doses without a significant interaction (P =0.90). The 12-month cumulative incidence of major bleeding was higher in the 12-month group than 3-month group for the 60 mg edoxaban subgroup (14.3% vs. 4.4%, P=0.046; OR, 3.61; 95% CI, 0.97-13.52), whereas it did not significantly differ between the two groups for the 30 mg edoxaban subgroup (8.7% vs. 8.6%, P=0.89; OR, 0.97; 95% CI, 0.49-1.91), signaling there was a potential interaction (P=0.07). CONCLUSIONS: A 12-month edoxaban regimen for cancer-associated isolated distal DVT was consistently superior to a 3-month regimen, across the edoxaban doses for the thrombotic risk. However, caution was suggested for the standard dose of edoxaban due to the potential for an increased risk of bleeding with prolonged anticoagulation therapy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA