Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur Heart J ; 45(10): 823-833, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38289867

RESUMEN

BACKGROUND AND AIMS: An electrical storm (ES) is a clinical emergency with a paucity of established treatment options. Despite initial encouraging reports about the safety and effectiveness of percutaneous stellate ganglion block (PSGB), many questions remained unsettled and evidence from a prospective multicentre study was still lacking. For these purposes, the STAR study was designed. METHODS: This is a multicentre observational study enrolling patients suffering from an ES refractory to standard treatment from 1 July 2017 to 30 June 2023. The primary outcome was the reduction of treated arrhythmic events by at least 50% comparing the 12 h following PSGB with the 12 h before the procedure. STAR operators were specifically trained to both the anterior anatomical and the lateral ultrasound-guided approach. RESULTS: A total of 131 patients from 19 centres were enrolled and underwent 184 PSGBs. Patients were mainly male (83.2%) with a median age of 68 (63.8-69.2) years and a depressed left ventricular ejection fraction (25.0 ± 12.3%). The primary outcome was reached in 92% of patients, and the median reduction of arrhythmic episodes between 12 h before and after PSGB was 100% (interquartile range -100% to -92.3%). Arrhythmic episodes requiring treatment were significantly reduced comparing 12 h before the first PSGB with 12 h after the last procedure [six (3-15.8) vs. 0 (0-1), P < .0001] and comparing 1 h before with 1 h after each procedure [2 (0-6) vs. 0 (0-0), P < .001]. One major complication occurred (0.5%). CONCLUSIONS: The findings of this large, prospective, multicentre study provide evidence in favour of the effectiveness and safety of PSGB for the treatment of refractory ES.


Asunto(s)
Taquicardia Ventricular , Anciano , Femenino , Humanos , Masculino , Estudios Prospectivos , Ganglio Estrellado , Volumen Sistólico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Resultado del Tratamiento , Fibrilación Ventricular/etiología , Función Ventricular Izquierda , Persona de Mediana Edad
2.
Europace ; 25(2): 366-373, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36164853

RESUMEN

AIMS: There is an increasing trend evaluating the role of non-pulmonary vein (PV) triggers to improve ablation outcomes in persistent atrial fibrillation (AF) as pulmonary vein isolation (PVI) strategy alone has modest outcomes. We investigated the long-term safety and efficacy of left atrial appendage isolation (LAAi) in addition to PVI using cryoballoon (CB) in persistent AF. METHODS AND RESULTS: In this multicentre retrospective analysis, we included a total of 193 persistent AF patients (mean age: 60 ± 11 years, 50.3% females) who underwent PVI and LAAi using CB. Baseline and follow-up data including electrocardiography (ECG), 24 h Holter ECGs, and echocardiography were recorded for all patients. Atrial tachyarrhythmia (ATa) recurrence was defined as the detection of AF, atrial flutter, or atrial tachycardia (≥30 s) after a 3-month blanking period. At a median follow-up of 55 (36.5-60.0) months, 85 (67.9%) patients with PVI + LAAi were in sinus rhythm after the index procedure. Ischaemic stroke/transient ischemic attack occurred in 14 (7.2%) patients at a median of 24 (2-53) months following catheter ablation. Multivariate regression analysis revealed heart failure with preserved ejection fraction [hazard ratio (HR) 2.29, 95% confidence interval (CI) 1.04-5.02; P = 0.038], male gender (HR 0.53, 95% CI 0.29-0.96; P = 0.037), and LA area (HR 1.04, 95% CI 0.53-1.32; P = 0.023) as independent predictors of ATa recurrence. CONCLUSION: Our findings demonstrated that the LAAi + PVI strategy using CB had acceptable long-term outcomes in patients with persistent AF. Systemic thrombo-embolic events are an important concern throughout the follow-up, which were mostly observed in case of non-adherence to anticoagulants.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Isquemia Encefálica , Ablación por Catéter , Criocirugía , Venas Pulmonares , Accidente Cerebrovascular , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Estudios Retrospectivos , Isquemia Encefálica/etiología , Resultado del Tratamiento , Criocirugía/efectos adversos , Criocirugía/métodos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
3.
Europace ; 25(3): 873-879, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36695332

RESUMEN

AIMS: The aim of this study was to compare procedural efficacy and safety, including 1-year freedom from AF recurrence, between the novel cryoballoon system PolarX (Boston Scientific) and the Arctic Front Advance Pro (AFA-Pro) (Medtronic), in patients with paroxysmal AF undergoing PVI. METHODS AND RESULTS: This multicentre prospective observational study included 267 consecutive patients undergoing a first cryoablation procedure for paroxysmal AF (137 PolarX, 130 AFA-Pro). Kaplan-Meier curves with the log-rank test was used to compare the 1-year freedom from AF recurrence between both groups. Multivariate Cox model was performed to evaluate whether the type of procedure (PolarX vs. AFA-Pro) had an impact on the occurrence of AF recurrences after adjustment on potentially confounding factors. The PolarX reaches lower temperatures than the AFA-Pro (LSPV 52 ± 5, vs. 59 ± 6; LIPV 49 ± 6 vs. 56 ± 6; right superior pulmonary vein: 49 ± 6 vs. 57 ± 7; right inferior pulmonary vein: 52 ± 6 vs. 59 ± 6; P < 0.0001). A higher rate of transient phrenic nerve palsy was found in patients treated with the PolarX system (15% vs. 7%, P = 0.05). After a mean follow-up of 15 ± 5 months, 20 patients (15%) had recurrences in AFA-Pro group and 27 patients (19%) in PolarX group (P = 0.35). Based on survival analysis, no significant difference was observed between both groups with a 12-month free of recurrence survival of 91.2% (85.1-95.4%) vs. 83.7% (76.0%-89.1%) (log-rank test P = 0.11). In multivariate Cox model hazard ratio of recurrence for PolarX vs. AFA-Pro was not significant [HR = 1.6 (0.9-2.8), P = 0.12]. CONCLUSION: PolarX and AFA-Pro have comparable efficacy and safety profiles for pulmonary veins isolation in paroxysmal atrial fibrillation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Estudios Prospectivos , Criocirugía/efectos adversos , Criocirugía/métodos , Modelos de Riesgos Proporcionales , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Recurrencia
4.
Artículo en Inglés | MEDLINE | ID: mdl-39317656

RESUMEN

BACKGROUND: Electrical Storm (ES) is a life-threatening condition requiring a rapid management. Percutaneous Stellate Ganglion Block (PSGB) proved to be safe and effective on top of standard therapy, but no data are available about its early use. METHODS: We considered all patients enrolled from 1st July 2017 to 30th April 2024 in the STAR registry (STellate ganglion block for Arrhythmic stoRm), a multicentre, international, observational, prospective registry. We aimed to assess the effectiveness of the first PSGB only. Patients were divided into two groups depending on whether they received PSGB before (Early-PSGB, often due to AAD contraindication) or after (Delayed-PSGB) intravenous antiarrhythmic drugs (AADs other than beta-blockers). RESULTS: We considered 180 PSGB (26 Early-PSGB and 154 AAD-first). In the early-PSGB group we observed a statistically significant reduction of treated arrhythmic events in the hour after PSGB compared to the hour before: 0 (0-0) vs 4.5 (1-10), p<0.001 and the extent of the reduction was similar in the Early-PSGB and delayed-PSGB group [-4.5 (-7 to -2) vs. -2.5 (-3.5 to -1.5), p=ns]. The percentage of patients free from arrhythmias was similar in the two groups up to 12 hours after PSGB (81%vs 84%, p=0.6 after one hour; 77% vs 79%, p=0.8 at three hours and 65% vs 69%, p= 0.7 after 12 hours). CONCLUSIONS: PSGB proved to be effective also when used early in the treatment of ES. Due to its rapidity of action, our results may suggest its early use to reduce the number of defibrillations and possibly to reduce the likelihood of a refractory ES.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA