Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ren Fail ; 36(1): 119-22, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24059653

RESUMEN

Various reasons such as malignancies and chronic infections may cause weight loss in kidney transplant patients. In this report, iron overload as a rare cause of weight loss in a kidney transplant patient is presented. Forty-seven-year-old male patient who transplanted from a deceased donor 5 years ago was hospitalized because of 20 kg of weight loss. In medical history, he had history of hemodialysis for 89 months and received 100-300 mg of intravenous iron therapy per week before transplantation and transfused eight units of blood. In physical examination, weight and height were 45 kg and 185 cm, respectively. Respiratory and cardiac auscultation was normal. Laboratory results revealed as follow: glucose 76 mg/dL, urea 60 mg/dL, creatinine 1.35 mg/dL, aspartate aminotransferase 74 U/L, alanine aminotransferase 77 U/L, C-reactive protein 2.59 mg/dL, albumin 3.3 g/dL, globulin 3.4 g/dL, white blood cells 3200/mm(3), hemoglobin 13.1 g/dL and platelets 190,000/mm(3). Chest and abdominal tomography didn't reveal any pathology. Portal Doppler ultrasound showed signs of early cirrhosis. Viral and autoimmune hepatitis markers were negative. Ferritin was 5300 ng/mL and transferrin saturation was 82%. In liver biopsy, hemosiderosis was diagnosed and heterozygous H63D gene mutation was detected. Totally, 19 units of phlebotomy were performed. Liver function tests and serum ferritin decreased gradually. At outpatient follow-up in 6 months, he returned to former weight. In conclusion, there can be several causes of weight loss in kidney transplant patients. Iron overload can come across as a rare cause of weight loss. In these patients, ferritin levels should be checked and diagnosis should be clarified by liver biopsy and gene mutation analysis.


Asunto(s)
Sobrecarga de Hierro/complicaciones , Trasplante de Riñón , Complicaciones Posoperatorias/etiología , Pérdida de Peso , Hepatitis Autoinmune/etiología , Hepatitis Autoinmune/genética , Hepatitis Autoinmune/metabolismo , Humanos , Sobrecarga de Hierro/genética , Masculino , Persona de Mediana Edad , Mutación , Complicaciones Posoperatorias/genética , Complicaciones Posoperatorias/metabolismo , Pérdida de Peso/genética , Pérdida de Peso/inmunología
2.
J Biomech ; 82: 62-69, 2019 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-30384999

RESUMEN

Knee joint laxity or instability is a common problem that may have detrimental consequences for patients. Unfortunately, assessment of knee joint laxity is limited by current methodologies resulting in suboptimal diagnostics and treatment. This paper presents a novel method for accurately measuring non-invasive knee joint laxity in four degrees-of-freedom (DOF). An arthrometer, combining a parallel manipulator and a six-axis force/moment sensor, was developed to be used in combination with a low-dose biplanar x-ray system and 3D image data to reconstruct tibiofemoral position and orientation of laxity measurements. As proof-of-concept, four cadaveric knees were tested in the device. Each cadaveric knee was mounted in the device at approximately 30° of flexion and twelve monoplanar anteroposterior, mediolateral and internal/external load cases were applied. Additionally, four biplanar load cases were applied, consisting of different combinations of anteroposterior and internal/external loads. The arthrometer was limited to four DOF to address the specific measurements. For validation purposes, the pose reconstructions of tibia and femur were compared with pose reconstructions of bone pin marker frames mounted on each bone. The measurements from the arthrometer in terms of translation and rotations displayed comparable values to what have previously been presented in the literature. Furthermore, the measurements revealed coupled motions in multiple planes, demonstrating the importance of multi DOF laxity measurements. The validation displayed an average mean difference for translations of 0.08 mm and an average limit of agreement between -1.64 mm and 1.80 mm. The average mean difference for rotations was 0.10° and the limit of agreement was between -0.85° and 1.05°. The presented method eliminates several limitations present in current methods and may prove a valuable tool for assessing knee joint laxity.


Asunto(s)
Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/fisiopatología , Articulación de la Rodilla/fisiopatología , Fenómenos Mecánicos , Fenómenos Biomecánicos , Cadáver , Humanos , Masculino , Rango del Movimiento Articular
3.
Nucl Med Commun ; 39(10): 901-907, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30086076

RESUMEN

OBJECTIVES: The value of baseline renal transplant scintigraphy (RTS) with technetium-99m diethylenetriaminepentaacetic acid (Tc-DTPA) performed within 2 days after transplantation in predicting early renal transplant outcome in pediatric recipients was assessed in this study. PATIENTS AND METHODS: Baseline RTS of 48 pediatric patients were studied retrospectively. Hilson's perfusion index, graft index (GI), time between peak perfusion and iliac artery (ΔP), and the ratios of peak perfusion to plateau (P : Pl), to peak iliac artery (P : A), and to peak uptake (P : U) were obtained. In 14 patients younger than 9 years old, because of faint visualization of iliac artery, the perfusion indices and GI could not be calculated. The 'Bedside Schwartz' formula was used for calculation of follow-up estimated glomerular filtrate rate (eGFR) values. The need for dialysis in the first week or decreasing serum creatinine of less than 10%/day during 3 consecutive days after the transplantation was accepted as delayed graft function (DGF). The patients, whose creatinine reduction ratio was less than 70% on day 7 after transplantation without DGF, were accepted as slow graft function (SGF). RESULTS: The means of GI, P : U, and Hilson's perfusion index were significantly high in SGF/DGF (n=10). GI and P : U had very high accuracy in the diagnosis of DGF/SGF (area under the curve>0.90). A strong correlation was found between P : U and same day and between GI and day 15 eGFR values. GI, P : U, and P : A were significant for the prediction of follow-up eGFR of less than 60 ml/min/1.73 m. GI was more accurate than the others. CONCLUSION: Our experience in this study underlines the importance of RTS, especially with the use of GI and P : U, which are very valuable in diagnosing DGF/SGF and predicting early transplant outcome in pediatric recipients.


Asunto(s)
Funcionamiento Retardado del Injerto/diagnóstico por imagen , Trasplante de Riñón , Valor Predictivo de las Pruebas , Niño , Femenino , Humanos , Masculino , Cintigrafía , Pentetato de Tecnecio Tc 99m , Factores de Tiempo
4.
Adv Clin Exp Med ; 21(5): 633-6, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23356200

RESUMEN

BACKGROUND: Clinical diagnosis of appendicitis is often difficult in atypical patients. OBJECTIVES: The authors aim to determine the diagnostic accuracy of ultrasonography (US) for acute appendicitis. MATERIAL AND METHODS: 121 consecutive patients with right lower abdomen pain were evaluated. Of them, 25 were excluded due to not having performed a preoperative US and 5 were obese (Body Mass Index > 30). A total of 91 patients were evaluated. The patients were assessed clinically and radiologically. Blood and urine analysis was carried out in all patients. US was performed with a Toshiba Fomio 8 brand machine with 3.75 and 8 MHz linear probes. Patients underwent an operation and an appendicectomy was done. Specimens were sent for histopathology to confirm appendicitis. RESULTS: Ultrasound supported the diagnosis of acute appendicitis in 58 (63.7%) patients. In the US with positive findings, 55 patients (94.8%) had inflamed appendices on histopathology and 5 (8.6%) had normal appendices. The overall sensitivity of ultrasonography was 71.4% and specificity was 78.5%. Positive predictive value (PPV), negative predictive value (NPV) and the diagnostic accuracy of ultrasonography are 94.8%, 33.3%, and 72.5% respectively. CONCLUSIONS: All diagnostic tests are adjunctive to the clinician. US should be the first step in the care of patients with right lower abdominal pain after the physical examination.


Asunto(s)
Apendicitis/diagnóstico por imagen , Dolor Abdominal/diagnóstico por imagen , Dolor Abdominal/etiología , Adolescente , Adulto , Apendicectomía , Apendicitis/complicaciones , Apendicitis/cirugía , Biopsia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sensibilidad y Especificidad , Ultrasonografía , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA