Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Neurourol Urodyn ; 40(1): 256-264, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33064316

RESUMEN

AIMS: Postprostatectomy incontinence is a major complication of prostatectomy. Although pelvic floor muscle training can successfully treat postprostatectomy incontinence, evidence for how muscle movement affects continence recovery is lacking. We evaluated dynamic factors of prostatectomy patients using cine magnetic resonance imaging to identify risk factors for postprostatectomy incontinence and reveal the contribution of pelvic floor muscles to continence recovery. METHODS: A total of 128 prostate cancer patients who underwent robot-assisted laparoscopic surgery were enrolled. Cine magnetic resonance imaging was performed preoperatively and 6 months after surgery. Continence was defined as pad-free or use of safety pads. We defined the bladder neck elevation distance during pelvic floor muscle training as the bladder elevation distance. Patients with continence recovery within 1 month comprised the continence group (n = 48); other patients comprised the incontinence group (n = 80). RESULTS: The preoperative bladder elevation distance was significantly longer in the continence group than in the incontinence group (10.4 vs. 8.2 mm; p < .001). The postoperative bladder elevation distance of the continence group tended to be longer (9.9 vs. 8.9 mm; p = .057). Multivariate analysis showed that the preoperative bladder elevation distance significantly contributed to continence recovery (p = .016). Patients with a longer preoperative bladder elevation distance (>8.5 mm) experienced continence recovery significantly faster than patients with a shorter distance (<8.5mm) (p = .038). CONCLUSIONS: Bladder elevation distance, a novel dynamic parameter, was strongly associated with early continence recovery. Cine magnetic resonance imaging can assess a patient's risk of postprostatectomy incontinence and guide pelvic floor muscle training.


Asunto(s)
Imagen por Resonancia Cinemagnética/métodos , Diafragma Pélvico/fisiopatología , Prostatectomía/efectos adversos , Neoplasias de la Próstata/complicaciones , Incontinencia Urinaria/diagnóstico por imagen , Incontinencia Urinaria/etiología , Anciano , Humanos , Masculino , Persona de Mediana Edad , Prostatectomía/métodos
2.
Biomed J ; : 100753, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38906327

RESUMEN

BACKGROUND: The high prevalence of desynchronized biological rhythms is becoming a primary public health concern. We assess complex and diverse inter-modulations among multi-frequency rhythms present in blood pressure (BP) and heart rate (HR). SUBJECTS: and Methods: We performed 7-day/24-hour Ambulatory BP Monitoring in 220 (133 women) residents (23 to 74 years) of a rural Japanese town in Kochi Prefecture under everyday life conditions. RESULTS: A symphony of biological clocks contributes to the preservation of a synchronized circadian system. (1) Citizens with an average 12.02-h period had fewer vascular variability disorders than those with shorter (11.37-h) or longer (12.88-h) periods (P<0.05), suggesting that the circasemidian rhythm is potentially important for human health. (2) An appropriate BP-HR coupling promoted healthier circadian profiles than a phase-advanced BP: lower 7-day nighttime SBP (106.8 vs. 112.9 mmHg, P=0.0469), deeper nocturnal SBP dip (20.5% vs. 16.8%, P=0.0101), and less frequent incidence of masked non-dipping (0.53 vs. 0.86, P=0.0378), identifying the night as an important time window. CONCLUSION: Adaptation to irregular schedules in everyday life occurs unconsciously at night, probably initiated from the brain default mode network, in coordination with the biological clock system, including a reinforced about 12-hour clock, as "a biological clock-guided core integration system".

3.
Br J Radiol ; 91(1084): 20170728, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29271235

RESUMEN

OBJECTIVE: To evaluate the usefulness of quantitative diffusion-weighted (DW) imaging acquired by multivendor magnetic resonance units for predicting grade of hepatocellular carcinoma (HCC). METHODS: 83 patients with 100 histologically diagnosed HCCs who underwent pre-operative liver DW imaging with b = 0 and1000 s mm-2 or b = 0 and800 s mm-2 at any of six institutions were included. Two radiologists independently measured the apparent diffusion coefficient (ADC) of the lesion as well as non-ADC parameters, such as the relative contrast ratio and the contrast-to-noise ratio (CNR) between the lesion and the liver parenchyma on high b-value DW images. The diagnostic performance of the DW parameters in discriminating poorly-differentiated HCCs was compared using receiver operating characteristic (ROC) analysis. RESULTS: The areas under the receiver operating characteristic curves for the CNR (86.4% [95% confidence interval (CI) (77.2-95.6] and 83.9% [95% CI 71.2-96.6] for b = 1000 and 800 s mm-2, respectively] and the relative contrast ratio (85.3% [95% CI 75.5-94.8] and 83.5% [95% CI 70.5-96.4]) tended to be superior to the ADC [71.1% [95% CI (56.9-85.2)] and 75.7% [95% CI (55.1-96.2)]; p < 0.05 for CNR vs ADC for b = 1000 s mm-2, but not significant for other parameters) for discrimination of poorly-differentiated HCCs. CONCLUSION: All DW parameters could discriminate HCC grade. Non-ADC parameters might be more useful than the ADC for predicting poorly-differentiated HCCs. Advances in knowledge: The utility of quantitative DW parameters for predicting HCC grade was demonstrated by using multivendor MR units.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Imagen de Difusión por Resonancia Magnética/instrumentación , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Anciano , Carcinoma Hepatocelular/cirugía , Medios de Contraste , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Japón , Neoplasias Hepáticas/cirugía , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
Radiat Med ; 25(3): 135-8, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17450339

RESUMEN

PURPOSE: Because superparamagnetic iron oxide is actively taken into the reticuloendothelial system, the signal intensity observed on T2-weighted images is reduced not only in the liver but also in the spleen. There is no difference in the reduction in signal intensity in the liver after contrast between the ferumoxides and ferucarbotran, but the reduction in signal intensity in the spleen is considerable. In the present study, we examined the efficacy of T2*-weighted imaging to compensate for the reduction in signal intensity in the spleen by administering ferucarbotran. MATERIALS AND METHODS: We examined the images obtained from 35 patients who underwent MRI with ferucarbotran. T2-weighted images and T2*-weighted images were obtained before and after administration of ferucarbotran, and the changes in signal intensity in the liver and spleen were then analyzed. RESULTS: A reduction in signal intensity was observed in the liver by both T2- and T2*-weighted imaging. In the spleen, the signal intensity was reduced on T2-weighted images but was not reduced on T2*-weighted images. CONCLUSION: The reduction in signal intensity due to administration of ferucarbotran is low in the spleen. Thus, it was considered necessary to approach the problem of diagnosing ectopic splenic tissue using ferucarbotran with caution.


Asunto(s)
Hierro , Imagen por Resonancia Magnética/métodos , Óxidos , Bazo/patología , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Dextranos , Femenino , Óxido Ferrosoférrico , Humanos , Hígado/patología , Nanopartículas de Magnetita , Masculino , Persona de Mediana Edad , Bazo/anomalías
5.
Radiat Med ; 24(10): 669-74, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17186321

RESUMEN

PURPOSE: The aim of this prospective study was to evaluate and compare acute adverse reactions between contrast medium containing moderate and high concentrations of iodine in patients undergoing computed tomography (CT). MATERIALS AND METHODS: A total of 945 patients undergoing enhanced CT were randomly assigned to receive one of two doses of contrast medium. We then prospectively investigated the incidence of adverse reactions. Iopamidol was used as the contrast medium, with a high concentration of 370 mg I/ml and a moderate concentration of 300 mg I/ml. The frequency of adverse reactions, such as pain at the injection site and heat sensation, were determined. RESULTS: Acute adverse reactions were observed in 2.4% (11/458) of the moderate-concentration group compared to 3.11% (15/482) of the high-concentration group; there was no significant difference in incidence between the two groups. Most adverse reactions were mild, and there was no significant difference in severity. One patient in the high-concentration group was seen to have a moderate adverse reaction. No correlation existed between the incidence of adverse reactions and patient characteristics such as sex, age, weight, flow amount, and flow rate. The incidence of pain was not significantly different between the two groups. In contrast, the incidence of heat sensation was significantly higher in the high-concentration group. CONCLUSIONS: The incidence and severity of acute adverse reactions were not significantly different between the two groups, and there were no severe adverse reactions in either group.


Asunto(s)
Medios de Contraste/efectos adversos , Yodo/efectos adversos , Tomografía Computarizada por Rayos X/efectos adversos , Medios de Contraste/administración & dosificación , Medios de Contraste/química , Femenino , Humanos , Yodo/administración & dosificación , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA