Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ann Hematol ; 101(8): 1825-1834, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35597847

RESUMEN

COVID-19 in patients with hematological diseases is associated with a high mortality. Moreover, preventive vaccination demonstrated reduced efficacy and the knowledge on influencing factors is limited. In this single-center study, antibody levels of the SARS-CoV-2 spike protein were measured ≥ 2 weeks after 2nd COVID-19 vaccination with a concentration ≥ 0.8 U/mL considered positive. Between July and October 2021, in a total of 373 patients (median age 64 years, 44% women) with myeloid neoplasms (n = 214, 57%), lymphoid neoplasms (n = 124, n = 33%), and other diseases (n = 35, 10%), vaccination was performed with BNT162b2 (BioNTech), mRNA-1273 (Moderna), ChADOx1 (AstraZeneca), or a combination. A total of 229 patients (61%) were on active therapy within 3 months prior vaccination and 144 patients (39%) were previously treated or treatment naïve. Vaccination-related antibody response was negative in 56/373 patients (15%): in 39/124 patients with lymphoid neoplasms, 13/214 with myeloid neoplasms, and 4/35 with other diseases. Active treatment per se was not correlated with negative response. However, rituximab and BTK inhibitor treatment were correlated significantly with a negative vaccination response, whereas younger age and chronic myeloid leukemia (CML) disease were associated with positive response. In addition, 5 of 6 patients with myeloproliferative neoplasm (MPN) and negative vaccination response were on active treatment with ruxolitinib. In conclusion, a remarkable percentage of patients with hematological diseases had no response after 2nd COVID-19 vaccination. Multivariable analysis revealed important factors associated with response to vaccination. The results may serve as a guide for better protection and surveillance in this vulnerable patient cohort.


Asunto(s)
Formación de Anticuerpos , Vacunas contra la COVID-19 , COVID-19 , Enfermedades Hematológicas , Anticuerpos Antivirales , Vacuna BNT162 , COVID-19/prevención & control , Vacunas contra la COVID-19/administración & dosificación , Vacunas contra la COVID-19/inmunología , Femenino , Enfermedades Hematológicas/complicaciones , Humanos , Leucemia Mielógena Crónica BCR-ABL Positiva/complicaciones , Masculino , Persona de Mediana Edad , Trastornos Mieloproliferativos/complicaciones , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , Insuficiencia del Tratamiento , Vacunación
2.
J Clin Microbiol ; 59(9): e0055921, 2021 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-34190575

RESUMEN

External quality assessment (EQA) is a key instrument for achieving harmonization, and thus a high quality, of diagnostic procedures. As reliable test results are crucial for accurate assessment of SARS-CoV-2 infection prevalence, vaccine response, and immunity, and thus for successful management of the ongoing COVID-19 pandemic, the Reference Institute for Bioanalytics (RfB) was the first EQA provider to offer an open scheme for anti-SARS-CoV-2 antibody detection. The main objectives of this EQA were (i) to gain insights into the current diagnostic landscape and the performance of serological tests in Europe and (ii) to provide recommendations for diagnostic improvements. Within the EQA, a blinded panel of precharacterized human serum samples with variable anti-SARS-CoV-2 antibody titers was provided for detection of anti-SARS-CoV-2 IgG, IgA, and IgM antibodies. Across the three distribution rounds in 2020, 284 laboratories from 22 countries reported a total of 3,744 results for anti-SARS-CoV-2 antibody detection using more than 24 different assays for IgG. Overall, 97/3,004 results were false for anti-SARS-CoV-2 IgG, 88/248 for IgA, and 34/124 for IgM. Regarding diagnostic sensitivity and specificity, substantial differences were found between the different assays used, as well as between certified and noncertified tests. For cutoff samples, a drop in the diagnostic sensitivity to 46.3% and high interlaboratory variability were observed. In general, this EQA highlights the current variability of anti-SARS-CoV-2 antibody detection, technical limitations with respect to cutoff samples, and the lack of harmonization of testing procedures. Recommendations are provided to help laboratories and manufacturers further improve the quality of anti-SARS-CoV-2 serological diagnostics.


Asunto(s)
COVID-19 , Pandemias , Anticuerpos Antivirales , Humanos , Inmunoglobulina M , SARS-CoV-2 , Sensibilidad y Especificidad , Pruebas Serológicas
3.
Clin Lab ; 67(12)2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34910436

RESUMEN

BACKGROUND: Despite increasing COVID-19 infection rates, low overall prevalence resulting in a poor positive predictive value (PPV) of serological tests requires strategies to increase specificity. We therefore investigated a dual diagnostic strategy and evaluated the correlation between the severity of a SARS-CoV-2 infection and the detectable immune-response. METHODS: Participants were systematically categorized into positive and control cohorts and a probability score of COVID-19 was calculated based on clinical symptoms. Six hundred eighty-two serum samples were analyzed using a highly specific high-throughput system. Combining the serological test result and probability score was performed as a dual diagnostic strategy. RESULTS: Specificity of 99.61% and sensitivity of 86.0% were the basis of our approach. A dual diagnostic strategy led to increased pre-test probability and thus to a test specificity of 100%. In a flu-like symptomatic population, we estimated a COVID-prevalence of 4.79%. Moreover, we detected significantly higher antibody values in patients with fever than without fever. CONCLUSIONS: Based on sensitivity and specificity results of our study being in line with previous findings, we demonstrated a dual assessment strategy including a symptom-based probability score and serological testing to increase the PPV. Moreover, the presence of fever seems to trigger a stronger immune-response.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , Humanos , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
4.
Cancers (Basel) ; 16(13)2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-39001486

RESUMEN

Introduction The kinetic of C-reactive protein (CRP) in the early phase of therapy with checkpoint inhibitors (CPI) and its prognostic value has already been investigated in several tumor entities. In particular, flare dynamics have been described as a positive prognostic parameter. The aim of this retrospective study is to examine the extent to which such an application can also be transferred to patients with recurrent or metastatic squamous cell carcinoma of the head and neck region (R/M-HNSCC). Material and Methods All patients treated with CPI for R/M-HNSCC at our clinic between 2018 and 2023 were included (n = 44). Demographic, clinical, histopathologic and laboratory data were extracted from the digital patient records and statistically analyzed. We then examined the CRP kinetic using two previously published classifications and proposed a new classification ourselves. Subsequently, correlation analyses were performed with the overall survival (OS) of the patients. Results Of the two CRP kinetic classifications previously published, only one showed a correlation with the result of the first re-staging, and neither showed a correlation with the OS of R/M-HNSCC patients. Our new CRP kinetic classification showed a significant association with OS in R/M-HNSCC patients (p = 0.05). In a multivariate analysis, our CRP kinetic classification (p = 0.007) and the outcome of the first re-staging (p = 0.002) were significant independent factors for OS. Discussion Our novel CRP kinetic classification significantly correlates with OS in R/M-HNSCC patients, indicating a potential prognostic marker. Existing classifications from other cancer entities showed limited prognostic significance, emphasizing the need for tailored markers. For validation, however, testing on larger R/M-HNSCC patient collectives is necessary.

5.
Vaccines (Basel) ; 11(3)2023 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-36992285

RESUMEN

BACKGROUND: Longitudinal humoral SARS-CoV-2 (severe acute respiratory syndrome coronavirus type 2) immunity for up to 15 months due to vaccination, the efficacy of vaccination strategies (homologous, vector-vector versus heterologous, vector-mRNA), the influence of vaccination side effects, and the infection rate in German healthcare workers need to be investigated. METHODS: In this study, 103 individuals vaccinated against SARS-CoV-2 were enrolled to examine their anti-SARS-CoV-2 anti-N- and anti-RBD/S1-Ig levels. A total of 415 blood samples in lithium heparin tubes were prospectively obtained, and a structured survey regarding medical history, type of vaccine, and vaccination reactions was conducted. RESULTS: All participants demonstrated a humoral immune response, among whom no values decreased below the positivity cutoff. Five to six months after the third vaccination, three participants showed anti-RBD/S1 antibodies of less than 1000 U/mL. We observed higher levels for heterologous mRNA-/vector-based combinations compared to pure vector-based vaccination after the second vaccination, which is harmonized after a third vaccination with the mRNA-vaccine only in both cohorts. The incidence of vaccine breakthrough in a highly exposed cohort was 60.3%. CONCLUSION: Sustained long-term humoral immunity was observed, indicating the superiority of a heterologous mRNA-/vector-based combination compared to pure vector-based vaccination. There was longevity of anti-RBD/S1 antibodies of at least 4 and up to 7 months without external stimulus. Regarding vaccination reactogenity, the occurrence of local symptoms as pain at the injection site was increased after the first mRNA application compared to the vector-vector cohort with a general decrease in adverse events at later vaccination time points. Overall, a correlation between the humoral vaccination response and vaccination side effects was not observed. Despite the high prevalence of vaccine breakthroughs, these only occurred in the later course of the study when more infectious variants, which are, however, associated with milder courses, were present. These results provide insights into vaccine-related serologic responses, and the study should be expanded using additional vaccine doses and novel variants in the future.

6.
Viruses ; 15(2)2023 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-36851668

RESUMEN

BACKGROUND: The duration of anti-SARS-CoV-2-antibody detectability up to 12 months was examined in individuals after either single convalescence or convalescence and vaccination. Moreover, variables that might influence an anti-RBD/S1 antibody decline and the existence of a post-COVID-syndrome (PCS) were addressed. METHODS: Forty-nine SARS-CoV-2-qRT-PCR-confirmed participants completed a 12-month examination of anti-SARS-CoV-2-antibody levels and PCS-associated long-term sequelae. Overall, 324 samples were collected. Cell-free DNA (cfDNA) was isolated and quantified from EDTA-plasma. As cfDNA is released into the bloodstream from dying cells, it might provide information on organ damage in the late recovery of COIVD-19. Therefore, we evaluated cfDNA concentrations as a biomarker for a PCS. In the context of antibody dynamics, a random forest-based logistic regression with antibody decline as the target was performed and internally validated. RESULTS: The mean percentage dynamic related to the maximum measured value was 96 (±38)% for anti-RBD/S1 antibodies and 30 (±26)% for anti-N antibodies. Anti-RBD/S1 antibodies decreased in 37%, whereas anti-SARS-CoV-2-anti-N antibodies decreased in 86% of the subjects. Clinical anti-RBD/S1 antibody decline prediction models, including vascular and other diseases, were cross-validated (highest AUC 0.74). Long-term follow-up revealed no significant reduction in PCS prevalence but an increase in cognitive impairment, with no indication for cfDNA as a marker for a PCS. CONCLUSION: Long-term anti-RBD/S1-antibody positivity was confirmed, and clinical parameters associated with declining titers were presented. A fulminant decrease in anti-SARS-CoV-2-anti-N antibodies was observed (mean change to maximum value 30 (±26)%). Anti-RBD/S1 antibody titers of SARS-CoV-2 recovered subjects boosted with a vaccine exceeded the maximum values measured after single infection by 235 ± 382-fold, with no influence on preexisting PCS. PCS long-term prevalence was 38.6%, with an increase in cognitive impairment compromising the quality of life. Quantified cfDNA measured in the early post-COVID-19 phase might not be an effective marker for PCS identification.


Asunto(s)
COVID-19 , Ácidos Nucleicos Libres de Células , Humanos , Anticuerpos Antivirales , Convalecencia , COVID-19/complicaciones , Inmunidad Humoral , Calidad de Vida , SARS-CoV-2 , Vacunas contra la COVID-19 , Síndrome Post Agudo de COVID-19/etiología
7.
Digit Health ; 9: 20552076231211552, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37936956

RESUMEN

Background: A major challenge in healthcare is the interpretation of the constantly increasing amount of clinical data of interest to inpatients for diagnosis and therapy. It is vital to accurately structure and represent data from different sources to help clinicians make informed decisions. Objective: We evaluated the usability of our tool 'Triptychon' - a three-part visualisation dashboard of essential patients' medical data provided by a direct overview of their hospitalisation information, laboratory, and vital parameters over time. Methods: The study followed a cohort of 20 participants using the mixed-methods approach, including interviews and the usability questionnaires, Health Information Technology Usability Evaluation Scale (Health-ITUES), and User Experience Questionnaire (UEQ). The participant's interactions with the dashboard were also observed. A thematic analysis approach was applied to analyse qualitative data and the quantitative data's task completion time and success rates. Results: The usability evaluation of the visualisation dashboard revealed issues relating to the terminology used in the user interface and colour coding in its left and middle panels. The Health-ITUES score was 3.72 (standard deviation (SD) = 1.0), and the UEQ score was 1.6 (SD = 0.74). The study demonstrated improvements in intuitive dashboard use and overall satisfaction with using the dashboard daily. Conclusion: The Triptychon dashboard is a promising new tool for medical data presentation. We identified design and layout issues of the dashboard for improving its usability in routine clinical practice. According to users' feedback, the three panels on the dashboard provided a holistic view of a patient's hospital stay.

8.
Life (Basel) ; 12(7)2022 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-35888058

RESUMEN

Sudden onset of anosmia is a phenomenon often associated with developing COVID-19 disease and has even been described as an initial isolated symptom in individual cases. In this case-control study, we investigated the feasibility of this condition as a suitable screening test in a population at risk. We performed a prospective study with a total of 313 subjects with suspected SARS-CoV-2 infection. In parallel to routine PCR analysis, a modified commercial scent test was performed to objectify the presence of potential anosmia as a predictor of SARS-CoV-2 positivity. Furthermore, a structured interview assessment of the participants was conducted. A total of 12.1% of the study participants had molecular genetic detection of SARS-CoV-2 infection in the nasopharyngeal swab. It could be demonstrated that these subjects had a significantly weaker olfactory identification performance of the scents. Further analysis of the collected data from the scent test and medical history via random forest (Boruta) algorithm showed that no improvement of the prediction power was achieved by this design. The assay investigated in this study may be suitable for screening general olfactory function. For the screening of COVID-19, it seems to be affected by too many external and internal biases and requires too elaborate and selective pre-test screening.

9.
Int J Infect Dis ; 105: 632-638, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33578017

RESUMEN

BACKGROUND: The detection of antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is mandatory for the diagnosis, retrospective assessment of disease progression, and correct evaluation of the current infection situation in the population. Many such assays have been launched by various manufacturers. Unfortunately, the new US Food and Drug Administration emergency use regulations have resulted in a situation where laboratories have to perform their own validation studies but many of these laboratories do not have the biobank needed to conduct the studies. METHODS: We introduce a method that allows institutions to quickly perform a verification study in a low-prevalence infection situation. As proof of concept, we used the Roche Elecsys® anti-SARS-CoV-2 electrochemiluminescence immunoassay and an SAP-based hospital information system. The Shenzhen YHLO Biotech IgM and IgG assay targeting other surface patterns was used as a confirmatory test. RESULTS: The Roche assay demonstrated a limit of detection of 0.069 cutoff index and successfully passed the performance validation according to Clinical and Laboratory Standards Institute EP15-A3. The study population of 627 inpatients has a median age of 64 years, and approximately 13% of the group were under intensive care at the respective time point. All patients included tested negative for SARS-CoV-2 infection by quantitative reverse transcription polymerase chain reaction (cobas® 6800, Roche, Mannheim, Germany). Only one false-positive result was obtained, resulting in a specificity for the Roche Elecsys anti-SARS-CoV-2 test of 99.84% and a negative predictive value of 99.98%. CONCLUSIONS: The anonymized use of residual material enables quick evaluation of anti-SARS-CoV-2 immunoassays, as shown in this work with the Roche Elecsys assay. Comparison of the control population with economic data makes it possible to validate the sampling set and therefore to determine diagnostic specificity. By use of the approach chosen, it was shown that the Roche test achieved very good results in terms of diagnostic specificity, reproducibility, and limit of detection.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Estudios de Validación como Asunto , Anciano , Anticuerpos Antivirales/inmunología , Femenino , Alemania , Humanos , Inmunoensayo/métodos , Laboratorios , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , SARS-CoV-2 , Sensibilidad y Especificidad
10.
Int J Infect Dis ; 107: 221-227, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33932604

RESUMEN

INTRODUCTION: The longevity of antibody levels against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the duration of immunity are current topics of major scientific interest. Antibody kinetics during the acute phase are well studied, whereas the long-term kinetics are yet to be determined, with contradictory results from the studies to date. Here, we present a longitudinal analysis of the serological responses to a SARS-CoV-2 infection following convalescence and the association with post-COVID syndrome (PCS). MATERIALS AND METHODS: A total of 237 serum samples were prospectively collected from 61 participants who had had a SARS-CoV-2 infection, which was confirmed using quantitative reverse-transcription polymerase chain reaction (qRT-PCR). For each participant, anti-nucleocapsid (N) and anti-spike subunit 1 receptor binding domain (RBD/S1) immunoglobulin (Ig) levels were regularly determined over a period of 8 months. COVID-19-associated symptoms were assessed using a standardized questionnaire at study entry and again after 6 months. RESULTS: Antibodies were detectable in 56 of the 61 participants. No substantial decline in anti-SARS-CoV-2 pan-Ig levels was observed for the duration of the follow-up period. Antibody levels correlated positively with the disease severity, body mass index, fever, and smoking status. It was found that 46.8% of the participants suffered from PCS, with olfactory and gustatory dysfunctions being the most commonly reported symptoms. CONCLUSION: The results demonstrate stable anti-SARS-CoV-2 antibody titers and thus may indicate a long-lasting immunity. The results are in line with recently published data and provide further insight concerning asymptomatic to mildly-affected patients, the association with clinical features, and the frequency of PCS.


Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/inmunología , Convalecencia , SARS-CoV-2/inmunología , Adolescente , Adulto , Anciano , Prueba Serológica para COVID-19 , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
11.
Int J Infect Dis ; 103: 590-596, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33310108

RESUMEN

OBJECTIVE: Numerous immunoassays for detecting antibodies directed against SARS-CoV-2 have been rapidly developed and released. Validations of these have been performed with a limited number of samples. The lack of standardisation might lead to significantly different results. This study compared ten automated assays from six vendors in terms of sensitivity, specificity and reproducibility. METHODS: This study compared ten fully automated immunoassays from the following vendors: Diasorin, Epitope Diagnostics, Euroimmun, Roche, YHLO, and Snibe. The retrospective part of the study included patients with a laboratory-confirmed COVID-19 infection, and controls comprised patients with a suspected infection, in whom the disease was excluded. Furthermore, biobanked sera were taken as negative controls (n = 97). The retrospective part involved four groups: (1) laboratory-confirmed COVID-19 infection (n = 183); (1B) suspected COVID-19 infection (n = 167) without a qRT-PCR result but positive serological results from at least two different assays, and suspected COVID-19 infection due to a positive serological result from the Roche assay (n = 295); (2) biobanked sera obtained from patients before the emergence of SARS-CoV-2 (n = 97) as negative controls; and (2A) probably COVID-19-negative sera with negative serological results from at least two different assays (n = 152). RESULTS: Overall diagnostic sensitivities were: Euroimmun (IgA) 87%; Epitope Diagnostics (IgG) 83%; YHLO (IgG) 77%; Roche (IgM/IgG) 77%; Euroimmun (IgG) 75%; Diasorin (IgG) 53%; Epitope Diagnostics (IgM) 52%; Snibe (IgG) 47%; YHLO (IgM) 35%; and Snibe (IgM) 26%. Diagnostic specificities were: YHLO (IgG) 100%; Roche, 100%; Snibe (IgM/IgG) 100%; Diasorin (IgG) 97%; Euroimmun (IgG) 94%; YHLO (IgM) 94%; Euroimmun (IgA) 83%. CONCLUSION: Assays from different vendors substantially varied in terms of their performance. These findings might facilitate selection of appropriate serological assays.


Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/diagnóstico , Inmunoensayo/métodos , SARS-CoV-2/inmunología , Adulto , Prueba de COVID-19 , Femenino , Humanos , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
12.
Clin Chim Acta ; 510: 73-78, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32652161

RESUMEN

BACKGROUND: For epidemiologic, social and economic reasons, assessment of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection prevalence and immunity are important to adapt decisions to current demands. Hence, immunoassays for detection of anti-SARS-CoV-2 antibodies are introduced rapidly without requiring FDA emergency use authorization approval. Thus, evaluation of test performance predominantly relies on laboratories. This study aimed to evaluate the test performance of recently launched commercial immunoassays in serum and plasma samples. METHODS: 51 serum samples from 26 patients with confirmed SARS-CoV-2 infection after end of quarantine and 25 control patients were analyzed using anti-SARS-CoV-2 IgG immunoassays from Roche, Euroimmun and Epitope to assess diagnostic sensitivity and specificity. 20 matching pairs of serum and plasma samples were included to analyze comparability between different specimens. RESULTS: Overall, a diagnostic sensitivity of 92.3%, 96.2-100% and 100% with a respective diagnostic specificity of 100%, 100% and 84-86% for the immunoassays from Roche, Euroimmun and Epitope were determined. In total, 84-96% of samples were correctly classified as negative and 92.3-95.2% as positive. The level of concordance between plasma- and serum-based testing diverged between the assays (Epitope r2 = 0.97; Euroimmun r2 = 0.91; Roche r2 = 0.76). CONCLUSIONS: The immunoassays from Euroimmun and Roche revealed a higher specificity than the Epitope assay without a substantial drop of diagnostic sensitivity. Significant differences between plasma- and serum-based testing highlights the need for determination of appropriate cut-offs per specimen type. Hence, there is an urgent need for test harmonization and establishment of quality standards for an appropriate use of COVID-19 serological tests.


Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus/inmunología , Inmunoensayo/métodos , Adulto , Anciano , Aprobación de Recursos , Femenino , Humanos , Inmunoensayo/instrumentación , Masculino , Persona de Mediana Edad , SARS-CoV-2 , Estados Unidos , United States Food and Drug Administration , Adulto Joven
13.
Neuroscience ; 387: 116-122, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-28978415

RESUMEN

This study aimed to investigate the relation of GABA and glutamate levels in the posterior insula and mechanical pain sensitivity in healthy subjects. Nineteen healthy female individuals underwent single voxel magnetic resonance spectroscopy (MRS) at 3 T. Metabolites were measured in the right posterior insula using MEGA-PRESS spectral editing. Mechanical pain sensitivity was experimentally assessed with pinprick stimuli on a numeric rating scale. Ratings of perceived intensity of 256 mN and 512 mN pinprick stimuli were negatively correlated with GABA levels and positively with glutamate levels in the posterior insula. Pinprick pain ratings were also positively correlated with the glutamate/GABA ratio. No significant correlation for pinprick stimuli of lower forces than 256 mN was observed. The results of our study support the hypothesis that excitatory and inhibitory neurotransmitter levels and/or the ratio of glutamate/GABA levels in the posterior insula are related to individual differences in pain sensitivity. These results are in line with chronic pain studies, where elevated glutamate/GABA ratios in the insular cortex of patients with chronic pain syndromes were observed.


Asunto(s)
Corteza Cerebral/metabolismo , Ácido Glutámico/metabolismo , Umbral del Dolor/fisiología , Ácido gamma-Aminobutírico/metabolismo , Femenino , Voluntarios Sanos , Humanos , Espectroscopía de Resonancia Magnética , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA