Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
ACS Omega ; 5(31): 19469-19477, 2020 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-32803041

RESUMEN

Fluorescence sensing of oxalate has garnered some attention in the past two decades as a result of this anion's prominence and impact on society. Previous work on oxalate sensors and other divalent anion sensors has led to the conclusion that the sensors are selective for the anion under investigation. However, sensor selectivity is often determined by testing against a relatively small array of "guest" molecules or analytes and studies often exclude potentially interfering compounds. For example, studies on oxalate sensors have excluded compounds such as citrate and urate, which are anions in the biological matrices where oxalate is measured (e.g., urine, blood, and bacterial lysate). In the present study, we reassessed the selectivity of a dinuclear copper(II) macrocycle (Cu2L) in an eosin Y displacement assay using biologically relevant anions. Although previously reported as selective for oxalate, we found greater indicator displacement (fluorescence response) for urate and oxaloacetate and a significant response to citrate. These anions are larger than oxalate and do not appear to fit into the putative binding pocket of Cu2L. Consistent with previous reports, Cu2L did not release eosin Y in the presence of several other dicarboxylates, including adipate, glutarate, malate (except at 10 mM), fumarate, succinate, or malonate (except at 10 mM), and the monocarboxylate acetate. This was demonstrated by the failure of the anions to reverse eosin Y quenching by Cu2L. We also assessed, for the first time, other monocarboxylates, including butyrate, pyruvate, lactate, propionate, and formate. None of these anions were able to displace eosin Y, indicating no interaction with Cu2L that interfered with the eosin Y binding site. Single-crystal X-ray crystallography revealed that nonselective binding of the anions is likely partly caused by readily accessible copper(II) ions on the external surface of Cu2L. In addition, π-π stacking of urate with the aromatic groups of Cu2L cannot be ruled out as a contributor to binding. We conclude that Cu2L is not suitable for oxalate sensing in a biological matrix unless interfering compounds are selectively removed or masked.

2.
Biol Open ; 8(4)2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-30837228

RESUMEN

ClopHensor, a fluorescent fusion protein, is a dual function biosensor that has been utilized as a tool for the simultaneous measurement of intracellular chloride and pH in cells. ClopHensor has traditionally been used in conjunction with fluorescence microscopy for single cell measurements. Here, we present a promising multi-well format advancement for the use of ClopHensor as a potential high-throughput method capable of measuring fluorescence signal intensity across a well of confluent cells with highly reproducible results. Using this system, we gained mechanistic insight into an endogenous oxalate transporter in Chinese hamster ovary (CHO) cells expressing ClopHensor and the human chloride transporter, SLC26A3. SLC26A3, a known anion exchanger, has been proposed to play a role in colonic oxalate absorption in humans. Our attempt to study the role of SLC26A3 in oxalate transport revealed the presence of an endogenous oxalate transporter in CHO cells. This transporter was strongly inhibited by niflumate, and exhibited clear saturability. Use of ClopHensor in a multi-well cell assay allowed us to quickly demonstrate that the endogenous oxalate transporter was unable to exchange chloride for bicarbonate, unlike SLC26A3.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA