Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Clin Chem Lab Med ; 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37838925

RESUMEN

Reporting a measurement procedure and its analytical performance following method evaluation in a peer-reviewed journal is an important means for clinical laboratory practitioners to share their findings. It also represents an important source of evidence base to help others make informed decisions about their practice. At present, there are significant variations in the information reported in laboratory medicine journal publications describing the analytical performance of measurement procedures. These variations also challenge authors, readers, reviewers, and editors in deciding the quality of a submitted manuscript. The International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Method Evaluation Protocols (IFCC WG-MEP) developed a checklist and recommends its adoption to enable a consistent approach to reporting method evaluation and analytical performance characteristics of measurement procedures in laboratory medicine journals. It is envisioned that the LEAP checklist will improve the standardisation of journal publications describing method evaluation and analytical performance characteristics, improving the quality of the evidence base that is relied upon by practitioners.

2.
Scand J Clin Lab Invest ; 83(7): 467-469, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37838359

RESUMEN

Reporting a measurement procedure and its analytical performance following method evaluation in a peer-reviewed journal is an important means for clinical laboratory practitioners to share their findings. It also represents an important source of evidence base to help others make informed decisions about their practice. At present, there are significant variations in the information reported in laboratory medicine journal publications describing the analytical performance of measurement procedures. These variations also challenge authors, readers, reviewers, and editors in deciding the quality of a submitted manuscript.The International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Method Evaluation Protocols (IFCC WG-MEP) developed a checklist and recommends its adoption to enable a consistent approach to reporting method evaluation and analytical performance characteristics of measurement procedures in laboratory medicine journals. It is envisioned that the LEAP checklist will improve the standardisation of journal publications describing method evaluation and analytical performance characteristics, improving the quality of the evidence base that is relied upon by practitioners.


Asunto(s)
Lista de Verificación , Servicios de Laboratorio Clínico , Humanos , Estándares de Referencia , Laboratorios , Laboratorios Clínicos
3.
Clin Chem Lab Med ; 60(8): 1225-1233, 2022 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-35607271

RESUMEN

OBJECTIVES: The 5α-reductase-type-2 deficiency (5ARD2) is a rare autosomal recessive 46,XY disorder of sex development caused by the mutated 5α-reductase type 2 (SRD5A2) gene. In this disease, defective conversion of testosterone to dihydrotestosterone leads to variable presentations of male ambiguous genitalia during fetal development. We aimed to examine characteristics of patients presenting with 5ARD2 over a 4 year period. METHODS: Random urine samples of control and patients with suspected 5ARD2 were collected and urine steroidomic metabolites were measured by Gas chromatography-mass spectrometry (GC-MS) in the period from 2017 to 2021 at National Children's Hospital, Hanoi Vietnam. 5α- to 5ß-reduced steroid metabolite ratio, 5a-tetrahydrocortisol to tetrahydrocortisol (5α-THF/THF), was reviewed by receive operator characteristics (ROC) curve analysis. Molecular testing was offered to 25 patients who were diagnosed with 5ARD2 by GC-MS urinary steroid analysis. RESULTS: Urine steroidomic profiling was conducted for 104 male controls and 25 patients between the ages of 6 months and 13 years old. Twelve of the twenty-five 5ARD2 patients agreed to undertake genetic analysis, and two mutations of the SRD5A2 gene were detected in each patient, confirming the diagnosis. All patients showed a characteristically low ratio of 5α-THF/THF. There was no overlap of 5α-THF/THF ratio values between control and 5ARD2 groups. The ROC of 5α-THF/THF ratio at 0.19 showed 100% sensitivity and 100% specificity for boys between 6 months and 13 years of age. CONCLUSIONS: Analysis of the urine steroid metabolome by GC-MS can be used to assist in the diagnosis of 5ARD2. We recommend consideration of random urine steroid analysis as a first-line test in the diagnosis of 5ARD2.


Asunto(s)
Oxidorreductasas , Esteroides , 3-Oxo-5-alfa-Esteroide 4-Deshidrogenasa/deficiencia , 3-Oxo-5-alfa-Esteroide 4-Deshidrogenasa/genética , Pueblo Asiatico , Niño , Trastorno del Desarrollo Sexual 46,XY , Cromatografía de Gases y Espectrometría de Masas , Humanos , Hipospadias , Lactante , Masculino , Proteínas de la Membrana , Errores Congénitos del Metabolismo Esteroideo , Esteroides/orina , Tetrahidrocortisol/orina , Vietnam
4.
Ann Clin Biochem ; 61(1): 3-7, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37838926

RESUMEN

Reporting a measurement procedure and its analytical performance following method evaluation in a peer-reviewed journal is an important means for clinical laboratory practitioners to share their findings. It also represents an important source of evidence base to help others make informed decisions about their practice. At present, there are significant variations in the information reported in laboratory medicine journal publications describing the analytical performance of measurement procedures. These variations also challenge authors, readers, reviewers and editors in deciding the quality of a submitted manuscript. The International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Method Evaluation Protocols (IFCC WG-MEP) developed a checklist and recommends its adoption to enable a consistent approach to reporting method evaluation and analytical performance characteristics of measurement procedures in laboratory medicine journals. It is envisioned that the LEAP checklist will improve the standardisation of journal publications describing method evaluation and analytical performance characteristics, improving the quality of the evidence base that is relied upon by practitioners.


Asunto(s)
Lista de Verificación , Servicios de Laboratorio Clínico , Humanos , Estándares de Referencia , Laboratorios
5.
Pract Lab Med ; 39: e00355, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38313811

RESUMEN

Reporting a measurement procedure and its analytical performance following method evaluation in a peer-reviewed journal is an important means for clinical laboratory practitioners to share their findings. It also represents an important source of evidence base to help others make informed decisions about their practice. At present, there are significant variations in the information reported in laboratory medicine journal publications describing the analytical performance of measurement procedures. These variations also challenge authors, readers, reviewers, and editors in deciding the quality of a submitted manuscript. The International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Method Evaluation Protocols (IFCC WG-MEP) developed a checklist and recommends its adoption to enable a consistent approach to reporting method evaluation and analytical performance characteristics of measurement procedures in laboratory medicine journals. It is envisioned that the LEAP checklist will improve the standardisation of journal publications describing method evaluation and analytical performance characteristics, improving the quality of the evidence base that is relied upon by practitioners.

6.
Biochem Med (Zagreb) ; 33(3): 030505, 2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37841772

RESUMEN

Reporting a measurement procedure and its analytical performance following method evaluation in a peer-reviewed journal is an important means for clinical laboratory practitioners to share their findings. It also represents an important source of evidence base to help others make informed decisions about their practice. At present, there are significant variations in the information reported in laboratory medicine journal publications describing the analytical performance of measurement procedures. These variations also challenge authors, readers, reviewers, and editors in deciding the quality of a submitted manuscript. The International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Method Evaluation Protocols (IFCC WG-MEP) developed a checklist and recommends its adoption to enable a consistent approach to reporting method evaluation and analytical performance characteristics of measurement procedures in laboratory medicine journals. It is envisioned that the Laboratory Evaluation and Analytical Performance Characteristics (LEAP) checklist will improve the standardisation of journal publications describing method evaluation and analytical performance characteristics, improving the quality of the evidence base that is relied upon by practitioners.


Asunto(s)
Lista de Verificación , Servicios de Laboratorio Clínico , Humanos , Laboratorios
7.
Clin Chim Acta ; 551: 117605, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37844680

RESUMEN

Reporting a measurement procedure and its analytical performance following method evaluation in a peer-reviewed journal is an important means for clinical laboratory practitioners to share their findings. It also represents an important source of evidence base to help others make informed decisions about their practice. At present, there are significant variations in the information reported in laboratory medicine journal publications describing the analytical performance of measurement procedures. These variations also challenge authors, readers, reviewers, and editors in deciding the quality of a submitted manuscript. The International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Method Evaluation Protocols (IFCC WG-MEP) developed a checklist and recommends its adoption to enable a consistent approach to reporting method evaluation and analytical performance characteristics of measurement procedures in laboratory medicine journals. It is envisioned that the LEAP checklist will improve the standardisation of journal publications describing method evaluation and analytical performance characteristics, improving the quality of the evidence base that is relied upon by practitioners.


Asunto(s)
Lista de Verificación , Servicios de Laboratorio Clínico , Humanos , Estándares de Referencia , Laboratorios
8.
BMJ Open ; 6(6): e011173, 2016 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-27329441

RESUMEN

OBJECTIVE: The prevalence of coeliac disease (CD) in Vietnam is unknown. To fill this void, we assessed the prevalence of serological markers of CD autoimmunity in a population of children in Hanoi. SETTING: The outpatient blood drawing laboratory of the largest paediatric hospital in North Vietnam was used for the study, which was part of an international project of collaboration between Italy and Vietnam. PARTICIPANTS: Children having blood drawn for any reason were included. Exclusion criteria were age younger than 2 years, acquired or congenital immune deficiency and inadequate sample. A total of 1961 children (96%) were enrolled (838 females, 1123 males, median age 5.3 years). OUTCOMES: Primary outcome was the prevalence of positive autoimmunity to both IgA antitransglutaminase antibodies (anti-tTG) assessed with an ELISA test and antiendomysial antibodies (EMA). Secondary outcome was the prevalence of CD predisposing human leucocyte antigens (HLA) (HLA DQ2/8) in the positive children and in a random group of samples negative for IgA anti-tTG. RESULTS: The IgA anti-tTG test was positive in 21/1961 (1%; 95% CI 0.61% to 1.53%); however, EMA antibodies were negative in all. HLA DQ2/8 was present in 7/21 (33%; 95% CI 14.5% to 56.9%) of the anti-tTG-positive children and in 72/275 (26%; 95% CI 21% to 32%) of those who were negative. CONCLUSIONS: Coeliac autoimmunity is rare in Vietnam, although prevalence of HLA DQ2/8 is similar to that of other countries. We hypothesise that the scarce exposure to gluten could be responsible for these findings.


Asunto(s)
Autoanticuerpos/sangre , Autoinmunidad/genética , Enfermedad Celíaca/genética , Antígenos HLA-DQ/sangre , Inmunoglobulina A/sangre , Transglutaminasas/sangre , Autoinmunidad/inmunología , Biomarcadores/sangre , Enfermedad Celíaca/sangre , Enfermedad Celíaca/epidemiología , Niño , Preescolar , Estudios Transversales , Ensayo de Inmunoadsorción Enzimática , Femenino , Genotipo , Humanos , Italia , Masculino , Prevalencia , Vietnam/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA