Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Clin Chem Lab Med ; 59(2): 325-332, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-33001848

RESUMEN

Objectives: In this paper, we describe the steps followed for the development of a certified reference material for immunoglobulin G antibodies against ß2-glycoprotein I (also known as apolipoprotein H). These steps include processing of the material, commutability, the impact of dilution, the appropriate reconstitution conditions, homogeneity and stability during transport and storage. Methods: We analysed 69 clinical samples from patients suffering from antiphospholipid syndrome with several commercial enzyme-linked immunosorbent assays (ELISA) purchased from in vitro diagnostic manufacturers. Results: Analysis of the results indicated that the candidate reference material can be safely freeze-dried, and that the user should carefully follow the reconstitution instructions as small changes in e.g. temperature may have unwanted effects. The statistical analysis of the commutability studies indicated that the analytical response of the reference material upon dilution is similar to that of clinical samples, and that correlation between results may differ from assay to assay. Finally yet importantly, the presented and developed candidate reference material is commutable for most assays tested, homogeneous and stable. Conclusions: Immunoglobulin G antibodies against ß2-glycoprotein I are associated with a higher risk of thrombosis and pregnancy complications. Their measurement is essential for the diagnosis and monitoring of antiphospholipid syndrome. These antibodies are detected by specific immunoassays, routinely used in clinical diagnostics, but various of these methods show enormous variability, in part due to the lack of a reference material.


Asunto(s)
Síndrome Antifosfolípido/diagnóstico , Inmunoglobulina G/química , beta 2 Glicoproteína I/sangre , Recolección de Muestras de Sangre , Almacenaje de Medicamentos , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Embarazo , Complicaciones del Embarazo/diagnóstico , Estándares de Referencia , Medición de Riesgo , Trombosis/diagnóstico
2.
Alzheimers Dement ; 16(11): 1493-1503, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32755010

RESUMEN

INTRODUCTION: Reference materials based on human cerebrospinal fluid were certified for the mass concentration of amyloid beta (Aß)1-42 (Aß42 ). They are intended to be used to calibrate diagnostic assays for Aß42 . METHODS: The three certified reference materials (CRMs), ERM-DA480/IFCC, ERM-DA481/IFCC and ERM-DA482/IFCC, were prepared at three concentration levels and characterized using isotope dilution mass spectrometry methods. Roche, EUROIMMUN, and Fujirebio used the three CRMs to re-calibrate their immunoassays. RESULTS: The certified Aß42 mass concentrations in ERM-DA480/IFCC, ERM-DA481/IFCC, and ERM-DA482/IFCC are 0.45, 0.72, and 1.22 µg/L, respectively, with expanded uncertainties (k = 2) of 0.07, 0.11, and 0.18 µg/L, respectively. Before re-calibration, a good correlation (Pearson's r > 0.97), yet large biases, were observed between results from different commercial assays. After re-calibration the between-assay bias was reduced to < 5%. DISCUSSION: The Aß42 CRMs can ensure the equivalence of results between methods and across platforms for the measurement of Aß42 .


Asunto(s)
Péptidos beta-Amiloides/líquido cefalorraquídeo , Inmunoensayo/normas , Calibración , Humanos , Inmunoensayo/métodos , Estándares de Referencia
3.
Clin Chem ; 59(9): 1322-9, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23649128

RESUMEN

BACKGROUND: Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material. METHODS: We performed a commutability study with 30 serum samples and the reference materials ERM-DA470, ERM-DA470k/IFCC, and ERM-DA472/IFCC, using 6 different methods. Data were analyzed according to the CLSI Guideline C53-A to assess whether the reference materials had the same behavior as the serum samples with respect to measurement results obtained with combinations of the methods used. RESULTS: Measurement results from different methods showed a good linear correlation for the serum samples. ERM-DA470 showed marked noncommutability for certain combinations of methods. ERM-DA470k/IFCC and ERM-DA472/IFCC were commutable for more combinations of methods. The lack of commutability of ERM-DA470 for certain combinations of methods correlates with results from the UK National External Quality Assessment Service showing discrepancies between results from these methods. For serum stored in the presence of sodium azide the results from different methods are essentially equivalent. CONCLUSIONS: Ceruloplasmin in ERM-DA470 is a fully documented example of a situation in which, due to lack of commutability, the use of a common material for calibration did not lead to harmonization .


Asunto(s)
Ceruloplasmina/análisis , Pruebas de Enzimas/normas , Suero/enzimología , Calibración , Humanos , Estándares de Referencia
5.
Clin Chem ; 56(12): 1880-8, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20923953

RESUMEN

BACKGROUND: The availability of a suitable matrix reference material is essential for standardization of the immunoassays used to measure serum proteins. The earlier serum protein reference material ERM-DA470 (previously called CRM470), certified in 1993, has led to a high degree of harmonization of the measurement results. A new serum protein material has now been prepared and its suitability in term of homogeneity and stability has been verified; after characterization, the material has been certified as ERM-DA470k/IFCC. METHODS: We characterized the candidate reference material for 14 proteins by applying a protocol that is considered to be a reference measurement procedure, by use of optimized immunoassays. ERM-DA470 was used as a calibrant. RESULTS: For 12 proteins [α(2) macroglobulin (A2M), α(1) acid glycoprotein (orosomucoid, AAG), α(1) antitrypsin (α(1)-protease inhibitor, AAT), albumin (ALB), complement 3c (C3c), complement 4 (C4), haptoglobin (HPT), IgA, IgG, IgM, transferrin (TRF), and transthyretin (TTR)], the results allowed assignment of certified values in ERM-DA470k/IFCC. For CRP, we observed a bias between the lyophilized and liquid frozen materials, and for CER, the distribution of values was too broad. Therefore, these 2 proteins were not certified in the ERM-DA470k/IFCC. Different value transfer procedures were tested (open and closed procedures) and found to provide equivalent results. CONCLUSIONS: A new serum protein reference material has been produced, and values have been successfully assigned for 12 proteins.


Asunto(s)
Proteínas Sanguíneas/normas , Proteínas Sanguíneas/análisis , Humanos , Inmunoensayo/normas , Estándares de Referencia , Suero
6.
Clin Chem Lab Med ; 48(6): 805-13, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20374041

RESUMEN

BACKGROUND: The availability of matrix reference materials is essential for the standardisation of (immuno)assays used to measure proteins. The reference material ERM-DA470 (previously called CRM470) certified in 1993 has led to a large degree of harmonisation of these assays. A new serum protein reference material has now been produced (ERM-DA470k). It is intended to replace ERM-DA470, and will additionally be certified for beta(2)-microglobulin (B2M). METHODS: Serum from 390 healthy donors was pooled and processed so as to stabilise, delipidate and 'maturate' it. Purified C-reactive protein (CRP) and recombinant B2M were added. Pilot batches were produced to study the stability, homogeneity, and commutability of the material. On the basis of the results with the trial batches it was decided to proceed with the processing of the main batch of a candidate reference material. RESULTS: Two pilot batches were produced and the processed and spiked serum lyophilised after filling (1 mL). The B2M in the material was shown to be stable and commutable. For CRP, it was discovered that freeze-drying led to a decrease in measurable protein. The main batch of candidate reference material was produced and fulfilled the required criteria in terms of optical transparency, homogeneity and stability. CONCLUSIONS: A new serum protein reference material has been produced with the properties required for a serum protein reference material for 14 proteins. An apparent loss of CRP of approximately 20% was observed upon freeze-drying of the material.


Asunto(s)
Proteínas Sanguíneas/normas , Inmunoensayo/normas , Electroforesis de las Proteínas Sanguíneas , Proteínas Sanguíneas/análisis , Proteína C-Reactiva/análisis , Proteína C-Reactiva/normas , Liofilización , Proyectos Piloto , Estabilidad Proteica , Proteínas Recombinantes/genética , Estándares de Referencia , Microglobulina beta-2/genética
7.
Anal Bioanal Chem ; 396(6): 1969-75, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19960339

RESUMEN

Despite the fact that the measurement unit for the quantification of GMOs in food and feed products has not yet been unambiguously agreed upon in Europe, international trade requires reliable GMO analysis measuring comparably the GMO content of products. The two reference systems, based either on mass fractions or on copy number ratios, and their metrological traceability chains are presented and discussed. It is concluded that, properly established and expressed, measurement results in copy number ratios can provide a metrologically sound reference system. In this case, certified reference materials used for calibration and quality control can be independent of each other and the uncertainty derived from calibration can correctly be included in the overall uncertainty of the GMO measurement. However, further efforts are required to establish this metrological system.


Asunto(s)
Técnicas Genéticas/normas , Plantas Modificadas Genéticamente/genética , Calibración , Dosificación de Gen , Estándares de Referencia
8.
J Agric Food Chem ; 55(9): 3268-74, 2007 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-17407307

RESUMEN

The quantification of GMOs by real-time PCR relies on an external calibrant. In this paper the suitability of two DNA calibrants, genomic DNA from plant leaves and plasmidic DNA, was investigated. The PCR efficiencies, the correlation coefficients of the calibration curves, and the ratios between PCR efficiencies of transgenic and endogenous sequences were compared for both calibrants using 59 data sets produced by 43 laboratories. There were no significant differences between plasmidic and genomic DNA except for the PCR efficiencies of the calibration curves for the transgene of the construct-specific real-time PCR method. In the GM system investigated, PCR efficiencies of plasmidic calibrants were slightly closer to the PCR efficiencies observed for the unknowns than those of the genomic DNA calibrant. Therefore, plasmidic DNA was the more suitable calibrant for the PCR measurements on genomic DNA extracted from MON 810 seeds. It is shown that plasmidic DNA is an appropriate choice for the calibration of measurements of MON 810 corn with respect to the DNA copy number ratio.


Asunto(s)
ADN de Plantas/análisis , Alimentos Modificados Genéticamente , Plantas Modificadas Genéticamente/genética , Zea mays/genética , Toxinas de Bacillus thuringiensis , Proteínas Bacterianas/genética , Toxinas Bacterianas/genética , Calibración , Endotoxinas/genética , Proteínas HSP70 de Choque Térmico/genética , Proteínas Hemolisinas/genética , Hojas de la Planta/genética , Reacción en Cadena de la Polimerasa , Semillas/genética
9.
J Agric Food Chem ; 55(12): 4728-34, 2007 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-17508757

RESUMEN

The presence of genetically modified organisms (GMOs) in food and feed products is subject to regulation in the European Union (EU) and elsewhere. As part of the EU authorization procedure for GMOs intended for food and feed use, reference materials must be produced for the quality control of measurements to quantify the GMOs. Certified reference materials (CRMs) are available for a range of herbicide- and insect-resistant genetically modified crops such as corn, soybean, and cotton. Here the development of the first CRM for a GMO that differs from its non-GMO counterpart in a major compositional constituent, that is, starch, is described. It is shown that the modification of the starch composition of potato (Solanum tuberosum L.) tubers, together with other characteristics of the delivered materials, have important consequences for the certification strategy. Moreover, the processing and characterization of the EH92-527-1 potato material required both new and modified procedures, different from those used routinely for CRMs produced from genetically modified seeds.


Asunto(s)
Plantas Modificadas Genéticamente/metabolismo , Solanum tuberosum/genética , Almidón/química , Almidón/genética , Amilosa/metabolismo , Secuencia de Bases , Cartilla de ADN , ADN de Plantas/genética , ADN de Plantas/aislamiento & purificación , Alimentos Modificados Genéticamente/normas , Reacción en Cadena de la Polimerasa , Agua/análisis
10.
J Agric Food Chem ; 55(9): 3258-67, 2007 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-17407306

RESUMEN

This paper is part of a set of three papers investigating metrological traceability of the quantification of DNA fragments as, for instance, used for quantification of genetic modifications. This paper evaluates the possible impact of several factors on results of real-time Polymerase Chain Reaction (PCR) measurements. It was found that the particle size of the powder samples does not have an influence, whereas the nature of the calibrant (plasmidic or genomic DNA) has a significant effect. Moreover, two real-time PCR detection methods (construct-specific and event-specific) for MON 810 corn were compared. The results obtained in a specifically designed interlaboratory study revealed a significant influence of the DNA extraction method on measurement results when the MON 810 construct-specific real-time PCR detection method was applied. Statistical analyses confirmed the importance of validating DNA extraction methods in conjunction with real-time PCR methods.


Asunto(s)
ADN de Plantas/análisis , Alimentos Modificados Genéticamente , Plantas Modificadas Genéticamente/genética , Reacción en Cadena de la Polimerasa/métodos , Zea mays/genética , Toxinas de Bacillus thuringiensis , Proteínas Bacterianas/genética , Toxinas Bacterianas/genética , Endotoxinas/genética , Proteínas HSP70 de Choque Térmico/genética , Proteínas Hemolisinas/genética , Semillas/genética
11.
Biomol Detect Quantif ; 9: 20-8, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27617229

RESUMEN

Compared to other PCR technologies, digital PCR is a potentially highly accurate approach for the quantification of nucleic acid fragments. This study describes the impact of four experimental factors, namely primer and probe chemistry, PCR amplification target, duplexing, and template type, on the measurement results obtained by reverse transcription digital PCR (RT-dPCR) of viral RNA using influenza A virus as a model. Along conventional dual labelled probes (DLP), alternative primer and probe chemistries, including Zip Nucleic Acids (ZNAs), Locked Nucleic Acids (LNAs), and Scorpions(®), were compared with two RNA template types: i) total genomic RNA extracted from cell cultured influenza A and ii) a synthetically prepared RNA transcript (In vitro transcribed RNA). While apparently duplexing or a different PCR target choice did not have a significant influence on the estimated RNA copy numbers, the impact of the choice of primer and probe chemistry and template type differed significantly for some methods. The combined standard uncertainty of the dPCR analysis results has been assessed, taking into account both the repeatability and the intermediate precision of the procedure. Our data highlight the importance of dPCR method optimisation and the advantage of using a more sophisticated primer and probe chemistry, which turned out to be dependent on the template type. Considerations are provided with respect to the molecular diagnostics of viral RNA pathogens, and more specifically, for precise quantification of RNA, which is of tremendous importance for the development of RNA calibration materials and the qualification of these calibrants as certified reference materials.

12.
Biomol Detect Quantif ; 9: 29-39, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27617230

RESUMEN

Digital PCR has become the emerging technique for the sequence-specific detection and quantification of nucleic acids for various applications. During the past years, numerous reports on the development of new digital PCR methods have been published. Maturation of these developments into reliable analytical methods suitable for diagnostic or other routine testing purposes requires their validation for the intended use. Here, the results of an in-house validation of a droplet digital PCR method are presented. This method is intended for the quantification of the absolute copy number concentration of a purified linearized plasmid in solution with a nucleic acid background. It has been investigated which factors within the measurement process have a significant effect on the measurement results, and the contribution to the overall measurement uncertainty has been estimated. A comprehensive overview is provided on all the aspects that should be investigated when performing an in-house method validation of a digital PCR method.

13.
J AOAC Int ; 85(3): 775-9, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12083274

RESUMEN

Certified reference materials (CRMs) are an essenIial tool in the quality assurance of analytical measurements. They are produced, certified, and used in accordance with relevant ISO (International Organization for Standardization) and BCR (Community Bureau of Reference) guidelines. The Institute for Reference Materials and Measurements (IRMM; Geel, Belgium) has produced the first powdery genetically modified organism (GMO) CRMs in cooperation with the Institute for Health and Consumer Protection (Ispra, Italy). Until now, different weight percentages in the range of 0-5% for 4 GMOs in Europe were produced and certified: Bt (Bacillus thuringiensis)-11 and Bt-176 maize, Roundup Ready soybean, and MON810 maize. Bt-11 and Bt-176 maize and Roundup Ready soybean were produced by IRMM on behalf of Fluka Chemie AG (Buchs, Switzerland). Characterization of used base material is the first step in production and is especially important for GMO CRMs. The production of powdery GMO CRMs and methods used for production control are described. Thorough control of homogeneity and stability are essential for certification of reference materials and ensure validity of the certificate for each bottle of a batch throughout a defined shelf-life. Because production of reference materials and their maintenance are very labor- and cost-intensive tasks, the usefulness of new types of GMO CRMs must be estimated carefully.


Asunto(s)
Análisis de los Alimentos/normas , Alimentos Modificados Genéticamente/normas , Plantas Modificadas Genéticamente/genética , ADN de Plantas/análisis , Ensayo de Inmunoadsorción Enzimática , Proteínas de Plantas/análisis , Estándares de Referencia
14.
J Agric Food Chem ; 56(19): 8825-31, 2008 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-18767863

RESUMEN

The real-time PCR methods recommended in the European Union for the quantitation of genetically modified (GM) maize events NK603, GA21, and MON 863 measure the number of copies of the GM event in relation to those of the maize-specific adh1 reference gene. The study reported here revealed that the targeted 70 base pair adh1 region exhibits a single nucleotide polymorphism (SNP839) that hampers the binding of the reverse primer used in the adh1 detection method. Partial fragments of the adh1-A and adh1-F allele were cloned. By allele-specific real-time PCR, it was shown that SNP839 corresponds to a common allelic polymorphism in maize. As a result, the quantitation of the GM maize events mentioned is positively or negatively biased, depending on the adh1 genotype of sample and calibrant. Therefore, it is proposed to revise the quantitative detection methods for NK603, GA21, and MON 863 maize.


Asunto(s)
Plantas Modificadas Genéticamente/genética , Polimorfismo de Nucleótido Simple/genética , Zea mays/genética , Alcohol Deshidrogenasa/genética , Clonación Molecular , ADN de Plantas/análisis , Reacción en Cadena de la Polimerasa
15.
Anal Bioanal Chem ; 383(2): 282-90, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16091947

RESUMEN

Roundup Ready soybean powder has been subjected to different amounts of DNA fragmentation to assess the accuracy of real-time PCR on processed food. Certified reference material (CRM) containing 10 g kg(-1) of Roundup Ready soybean (ERM-BF410d) prepared by a dry-mixing processing method was exposed to water at two temperatures, using three different mixing devices, or to baking temperature (250 degrees C) for 30 min. The amount of DNA extracted from the different samples was quantified by fluorimetry. The amount of fragmentation of the extracted DNA was characterised by gel and capillary electrophoresis and the percentage of genetically modified (GM) soybean was determined by a double quantitative real-time PCR method. Measurement of the event GTS 40-3-2 (RUR) was possible in all the treated materials, because small amplicons were amplified. Correct RUR percentages could be measured for intact powders with little or no DNA fragmentation. For samples with a high level of DNA degradation, however, the accuracy of the measurement was found to depend on the method used for DNA extraction. Genomic DNA isolated by use of silica resin resulted in statistically significant overestimation of the amount of GM.


Asunto(s)
Fragmentación del ADN , ADN/análisis , Harina/análisis , Glycine max/química , Electroforesis Capilar , Electroforesis en Gel de Poliacrilamida , Fluorometría , Reacción en Cadena de la Polimerasa , Silicio/química , Glycine max/genética , Temperatura , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA