Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Nature ; 601(7891): 110-117, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34758478

RESUMEN

Individuals with potential exposure to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) do not necessarily develop PCR or antibody positivity, suggesting that some individuals may clear subclinical infection before seroconversion. T cells can contribute to the rapid clearance of SARS-CoV-2 and other coronavirus infections1-3. Here we hypothesize that pre-existing memory T cell responses, with cross-protective potential against SARS-CoV-2 (refs. 4-11), would expand in vivo to support rapid viral control, aborting infection. We measured SARS-CoV-2-reactive T cells, including those against the early transcribed replication-transcription complex (RTC)12,13, in intensively monitored healthcare workers (HCWs) who tested repeatedly negative according to PCR, antibody binding and neutralization assays (seronegative HCWs (SN-HCWs)). SN-HCWs had stronger, more multispecific memory T cells compared with a cohort of unexposed individuals from before the pandemic (prepandemic cohort), and these cells were more frequently directed against the RTC than the structural-protein-dominated responses observed after detectable infection (matched concurrent cohort). SN-HCWs with the strongest RTC-specific T cells had an increase in IFI27, a robust early innate signature of SARS-CoV-2 (ref. 14), suggesting abortive infection. RNA polymerase within RTC was the largest region of high sequence conservation across human seasonal coronaviruses (HCoV) and SARS-CoV-2 clades. RNA polymerase was preferentially targeted (among the regions tested) by T cells from prepandemic cohorts and SN-HCWs. RTC-epitope-specific T cells that cross-recognized HCoV variants were identified in SN-HCWs. Enriched pre-existing RNA-polymerase-specific T cells expanded in vivo to preferentially accumulate in the memory response after putative abortive compared to overt SARS-CoV-2 infection. Our data highlight RTC-specific T cells as targets for vaccines against endemic and emerging Coronaviridae.


Asunto(s)
Infecciones Asintomáticas , COVID-19/inmunología , COVID-19/virología , ARN Polimerasas Dirigidas por ADN/inmunología , Células T de Memoria/inmunología , SARS-CoV-2/inmunología , Seroconversión , Proliferación Celular , Estudios de Cohortes , ARN Polimerasas Dirigidas por ADN/metabolismo , Evolución Molecular , Femenino , Personal de Salud , Humanos , Masculino , Proteínas de la Membrana/inmunología , Células T de Memoria/citología , Complejos Multienzimáticos/inmunología , SARS-CoV-2/enzimología , SARS-CoV-2/crecimiento & desarrollo , Transcripción Genética/inmunología
2.
Circulation ; 148(9): 778-797, 2023 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-37427428

RESUMEN

BACKGROUND: Cardiac fibroblasts have crucial roles in the heart. In particular, fibroblasts differentiate into myofibroblasts in the damaged myocardium, contributing to scar formation and interstitial fibrosis. Fibrosis is associated with heart dysfunction and failure. Myofibroblasts therefore represent attractive therapeutic targets. However, the lack of myofibroblast-specific markers has precluded the development of targeted therapies. In this context, most of the noncoding genome is transcribed into long noncoding RNAs (lncRNAs). A number of lncRNAs have pivotal functions in the cardiovascular system. lncRNAs are globally more cell-specific than protein-coding genes, supporting their importance as key determinants of cell identity. METHODS: In this study, we evaluated the value of the lncRNA transcriptome in very deep single-cell RNA sequencing. We profiled the lncRNA transcriptome in cardiac nonmyocyte cells after infarction and probed heterogeneity in the fibroblast and myofibroblast populations. In addition, we searched for subpopulation-specific markers that can constitute novel targets in therapy for heart disease. RESULTS: We demonstrated that cardiac cell identity can be defined by the sole expression of lncRNAs in single-cell experiments. In this analysis, we identified lncRNAs enriched in relevant myofibroblast subpopulations. Selecting 1 candidate we named FIXER (fibrogenic LOX-locus enhancer RNA), we showed that its silencing limits fibrosis and improves heart function after infarction. Mechanitically, FIXER interacts with CBX4, an E3 SUMO protein ligase and transcription factor, guiding CBX4 to the promoter of the transcription factor RUNX1 to control its expression and, consequently, the expression of a fibrogenic gene program.. FIXER is conserved in humans, supporting its translational value. CONCLUSIONS: Our results demonstrated that lncRNA expression is sufficient to identify the various cell types composing the mammalian heart. Focusing on cardiac fibroblasts and their derivatives, we identified lncRNAs uniquely expressed in myofibroblasts. In particular, the lncRNA FIXER represents a novel therapeutic target for cardiac fibrosis.


Asunto(s)
Cardiomiopatías , ARN Largo no Codificante , Animales , Humanos , Transcriptoma , ARN Largo no Codificante/genética , ARN Largo no Codificante/metabolismo , Cardiomiopatías/genética , Fibrosis , Análisis de Secuencia de ARN , Factores de Transcripción/genética , Infarto , Mamíferos/genética , Mamíferos/metabolismo , Ligasas/genética , Ligasas/metabolismo , Proteínas del Grupo Polycomb/genética , Proteínas del Grupo Polycomb/metabolismo
3.
Circulation ; 147(5): 364-374, 2023 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-36705028

RESUMEN

BACKGROUND: Acute myocardial injury in hospitalized patients with coronavirus disease 2019 (COVID-19) has a poor prognosis. Its associations and pathogenesis are unclear. Our aim was to assess the presence, nature, and extent of myocardial damage in hospitalized patients with troponin elevation. METHODS: Across 25 hospitals in the United Kingdom, 342 patients with COVID-19 and an elevated troponin level (COVID+/troponin+) were enrolled between June 2020 and March 2021 and had a magnetic resonance imaging scan within 28 days of discharge. Two prospective control groups were recruited, comprising 64 patients with COVID-19 and normal troponin levels (COVID+/troponin-) and 113 patients without COVID-19 or elevated troponin level matched by age and cardiovascular comorbidities (COVID-/comorbidity+). Regression modeling was performed to identify predictors of major adverse cardiovascular events at 12 months. RESULTS: Of the 519 included patients, 356 (69%) were men, with a median (interquartile range) age of 61.0 years (53.8, 68.8). The frequency of any heart abnormality, defined as left or right ventricular impairment, scar, or pericardial disease, was 2-fold greater in cases (61% [207/342]) compared with controls (36% [COVID+/troponin-] versus 31% [COVID-/comorbidity+]; P<0.001 for both). More cases than controls had ventricular impairment (17.2% versus 3.1% and 7.1%) or scar (42% versus 7% and 23%; P<0.001 for both). The myocardial injury pattern was different, with cases more likely than controls to have infarction (13% versus 2% and 7%; P<0.01) or microinfarction (9% versus 0% and 1%; P<0.001), but there was no difference in nonischemic scar (13% versus 5% and 14%; P=0.10). Using the Lake Louise magnetic resonance imaging criteria, the prevalence of probable recent myocarditis was 6.7% (23/342) in cases compared with 1.7% (2/113) in controls without COVID-19 (P=0.045). During follow-up, 4 patients died and 34 experienced a subsequent major adverse cardiovascular event (10.2%), which was similar to controls (6.1%; P=0.70). Myocardial scar, but not previous COVID-19 infection or troponin, was an independent predictor of major adverse cardiovascular events (odds ratio, 2.25 [95% CI, 1.12-4.57]; P=0.02). CONCLUSIONS: Compared with contemporary controls, patients with COVID-19 and elevated cardiac troponin level have more ventricular impairment and myocardial scar in early convalescence. However, the proportion with myocarditis was low and scar pathogenesis was diverse, including a newly described pattern of microinfarction. REGISTRATION: URL: https://www.isrctn.com; Unique identifier: 58667920.


Asunto(s)
COVID-19 , Lesiones Cardíacas , Miocarditis , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cicatriz , COVID-19/complicaciones , COVID-19/epidemiología , Hospitalización , Estudios Prospectivos , Factores de Riesgo , Troponina , Anciano
4.
Magn Reson Med ; 91(1): 118-132, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37667643

RESUMEN

PURPOSE: To investigate and mitigate the influence of physiological and acquisition-related parameters on myocardial blood flow (MBF) measurements obtained with myocardial Arterial Spin Labeling (myoASL). METHODS: A Flow-sensitive Alternating Inversion Recovery (FAIR) myoASL sequence with bSSFP and spoiled GRE (spGRE) readout is investigated for MBF quantification. Bloch-equation simulations and phantom experiments were performed to evaluate how variations in acquisition flip angle (FA), acquisition matrix size (AMS), heart rate (HR) and blood T 1 $$ {\mathrm{T}}_1 $$ relaxation time ( T 1 , B $$ {\mathrm{T}}_{1,B} $$ ) affect quantification of myoASL-MBF. In vivo myoASL-images were acquired in nine healthy subjects. A corrected MBF quantification approach was proposed based on subject-specific T 1 , B $$ {\mathrm{T}}_{1,B} $$ values and, for spGRE imaging, subtracting an additional saturation-prepared baseline from the original baseline signal. RESULTS: Simulated and phantom experiments showed a strong dependence on AMS and FA ( R 2 $$ {R}^2 $$ >0.73), which was eliminated in simulations and alleviated in phantom experiments using the proposed saturation-baseline correction in spGRE. Only a very mild HR dependence ( R 2 $$ {R}^2 $$ >0.59) was observed which was reduced when calculating MBF with individual T 1 , B $$ {\mathrm{T}}_{1,B} $$ . For corrected spGRE, in vivo mean global spGRE-MBF ranged from 0.54 to 2.59 mL/g/min and was in agreement with previously reported values. Compared to uncorrected spGRE, the intra-subject variability within a measurement (0.60 mL/g/min), between measurements (0.45 mL/g/min), as well as the inter-subject variability (1.29 mL/g/min) were improved by up to 40% and were comparable with conventional bSSFP. CONCLUSION: Our results show that physiological and acquisition-related factors can lead to spurious changes in myoASL-MBF if not accounted for. Using individual T 1 , B $$ {\mathrm{T}}_{1,B} $$ and a saturation-baseline can reduce these variations in spGRE and improve reproducibility of FAIR-myoASL against acquisition parameters.


Asunto(s)
Circulación Coronaria , Imagen de Perfusión Miocárdica , Humanos , Reproducibilidad de los Resultados , Circulación Coronaria/fisiología , Miocardio , Frecuencia Cardíaca , Fantasmas de Imagen , Imagen de Perfusión Miocárdica/métodos
5.
Medicina (Kaunas) ; 59(9)2023 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-37763715

RESUMEN

The objective of this review is to investigate the commonalities of microvascular (small vessel) disease in heart failure with preserved ejection fraction (HFpEF) and cerebral small vessel disease (CSVD). Furthermore, the review aims to evaluate the current magnetic resonance imaging (MRI) diagnostic techniques for both conditions. By comparing the two conditions, this review seeks to identify potential opportunities to improve the understanding of both HFpEF and CSVD.


Asunto(s)
Enfermedades de los Pequeños Vasos Cerebrales , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/diagnóstico por imagen , Volumen Sistólico , Encéfalo/diagnóstico por imagen , Enfermedades de los Pequeños Vasos Cerebrales/complicaciones , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Imagen por Resonancia Magnética
6.
Immunology ; 166(1): 68-77, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35156709

RESUMEN

SARS-CoV-2 infection results in different outcomes ranging from asymptomatic infection to mild or severe disease and death. Reasons for this diversity of outcome include differences in challenge dose, age, gender, comorbidity and host genomic variation. Human leukocyte antigen (HLA) polymorphisms may influence immune response and disease outcome. We investigated the association of HLAII alleles with case definition symptomatic COVID-19, virus-specific antibody and T-cell immunity. A total of 1364 UK healthcare workers (HCWs) were recruited during the first UK SARS-CoV-2 wave and analysed longitudinally, encompassing regular PCR screening for infection, symptom reporting, imputation of HLAII genotype and analysis for antibody and T-cell responses to nucleoprotein (N) and spike (S). Of 272 (20%) HCW who seroconverted, the presence of HLA-DRB1*13:02 was associated with a 6·7-fold increased risk of case definition symptomatic COVID-19. In terms of immune responsiveness, HLA-DRB1*15:02 was associated with lower nucleocapsid T-cell responses. There was no association between DRB1 alleles and anti-spike antibody titres after two COVID vaccine doses. However, HLA DRB1*15:01 was associated with increased spike T-cell responses following both first and second dose vaccination. Trial registration: NCT04318314 and ISRCTN15677965.


Asunto(s)
COVID-19 , Anticuerpos Antivirales , COVID-19/genética , Vacunas contra la COVID-19 , Cadenas HLA-DRB1/genética , Antígenos de Histocompatibilidad Clase I/genética , Humanos , SARS-CoV-2
7.
J Cardiovasc Magn Reson ; 24(1): 16, 2022 03 10.
Artículo en Inglés | MEDLINE | ID: mdl-35272664

RESUMEN

BACKGROUND: Measurement of cardiac structure and function from images (e.g. volumes, mass and derived parameters such as left ventricular (LV) ejection fraction [LVEF]) guides care for millions. This is best assessed using cardiovascular magnetic resonance (CMR), but image analysis is currently performed by individual clinicians, which introduces error. We sought to develop a machine learning algorithm for volumetric analysis of CMR images with demonstrably better precision than human analysis. METHODS: A fully automated machine learning algorithm was trained on 1923 scans (10 scanner models, 13 institutions, 9 clinical conditions, 60,000 contours) and used to segment the LV blood volume and myocardium. Performance was quantified by measuring precision on an independent multi-site validation dataset with multiple pathologies with n = 109 patients, scanned twice. This dataset was augmented with a further 1277 patients scanned as part of routine clinical care to allow qualitative assessment of generalization ability by identifying mis-segmentations. Machine learning algorithm ('machine') performance was compared to three clinicians ('human') and a commercial tool (cvi42, Circle Cardiovascular Imaging). FINDINGS: Machine analysis was quicker (20 s per patient) than human (13 min). Overall machine mis-segmentation rate was 1 in 479 images for the combined dataset, occurring mostly in rare pathologies not encountered in training. Without correcting these mis-segmentations, machine analysis had superior precision to three clinicians (e.g. scan-rescan coefficients of variation of human vs machine: LVEF 6.0% vs 4.2%, LV mass 4.8% vs. 3.6%; both P < 0.05), translating to a 46% reduction in required trial sample size using an LVEF endpoint. CONCLUSION: We present a fully automated algorithm for measuring LV structure and global systolic function that betters human performance for speed and precision.


Asunto(s)
Aprendizaje Automático , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Cinemagnética/métodos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Volumen Sistólico , Función Ventricular Izquierda
8.
Eur Heart J ; 42(19): 1866-1878, 2021 05 14.
Artículo en Inglés | MEDLINE | ID: mdl-33596594

RESUMEN

BACKGROUND: Troponin elevation is common in hospitalized COVID-19 patients, but underlying aetiologies are ill-defined. We used multi-parametric cardiovascular magnetic resonance (CMR) to assess myocardial injury in recovered COVID-19 patients. METHODS AND RESULTS: One hundred and forty-eight patients (64 ± 12 years, 70% male) with severe COVID-19 infection [all requiring hospital admission, 48 (32%) requiring ventilatory support] and troponin elevation discharged from six hospitals underwent convalescent CMR (including adenosine stress perfusion if indicated) at median 68 days. Left ventricular (LV) function was normal in 89% (ejection fraction 67% ± 11%). Late gadolinium enhancement and/or ischaemia was found in 54% (80/148). This comprised myocarditis-like scar in 26% (39/148), infarction and/or ischaemia in 22% (32/148) and dual pathology in 6% (9/148). Myocarditis-like injury was limited to three or less myocardial segments in 88% (35/40) of cases with no associated LV dysfunction; of these, 30% had active myocarditis. Myocardial infarction was found in 19% (28/148) and inducible ischaemia in 26% (20/76) of those undergoing stress perfusion (including 7 with both infarction and ischaemia). Of patients with ischaemic injury pattern, 66% (27/41) had no past history of coronary disease. There was no evidence of diffuse fibrosis or oedema in the remote myocardium (T1: COVID-19 patients 1033 ± 41 ms vs. matched controls 1028 ± 35 ms; T2: COVID-19 46 ± 3 ms vs. matched controls 47 ± 3 ms). CONCLUSIONS: During convalescence after severe COVID-19 infection with troponin elevation, myocarditis-like injury can be encountered, with limited extent and minimal functional consequence. In a proportion of patients, there is evidence of possible ongoing localized inflammation. A quarter of patients had ischaemic heart disease, of which two-thirds had no previous history. Whether these observed findings represent pre-existing clinically silent disease or de novo COVID-19-related changes remain undetermined. Diffuse oedema or fibrosis was not detected.


Asunto(s)
COVID-19 , Miocarditis , Medios de Contraste , Femenino , Gadolinio , Humanos , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Masculino , Miocarditis/diagnóstico por imagen , Miocardio , Valor Predictivo de las Pruebas , SARS-CoV-2 , Troponina , Función Ventricular Izquierda
9.
J Cardiovasc Magn Reson ; 23(1): 125, 2021 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-34758850

RESUMEN

BACKGROUND: Mapping of left ventricular (LV) native T1 is a promising non-invasive, non-contrast imaging biomarker. Native myocardial T1 times are prolonged in patients requiring dialysis, but there are concerns that the dialysis process and fluctuating fluid status may confound results in this population. We aimed to assess the changes in cardiac parameters on 3T cardiovascular magnetic resonance (CMR) before and after haemodialysis, with a specific focus on native T1 mapping. METHODS: This is a single centre, prospective observational study in which maintenance haemodialysis patients underwent CMR before and after dialysis (both scans within 24 h). Weight measurement, bio-impedance body composition monitoring, haemodialysis details and fluid intake were recorded. CMR protocol included cine imaging and mapping native T1 and T2. RESULTS: Twenty-six participants (16 male, 65 ± 9 years) were included in the analysis. The median net ultrafiltration volume on dialysis was 2.3 L (IQR 1.8, 2.5), resulting in a median weight reduction at post-dialysis scan of 1.35 kg (IQR 1.0, 1.9), with a median reduction in over-hydration (as measured by bioimpedance) of 0.75 L (IQR 0.5, 1.4). Significant reductions were observed in LV end-diastolic volume (- 25 ml, p = 0.002), LV stroke volume (- 13 ml, p = 0.007), global T1 (21 ms, p = 0.02), global T2 (- 1.2 ms, p = 0.02) following dialysis. There was no change in LV mass (p = 0.35), LV ejection fraction (p = 0.13) or global longitudinal strain (p = 0.22). On linear regression there was no association between baseline over-hydration (as defined by bioimpedance) and global native T1 or global T2, nor was there an association between the change in over-hydration and the change in these parameters. CONCLUSIONS: Acute changes in cardiac volumes and myocardial native T1 are detectable on 3T CMR following haemodialysis with fluid removal. The reduction in global T1 suggests that the abnormal native T1 observed in patients on haemodialysis is not entirely due to myocardial fibrosis.


Asunto(s)
Imagen por Resonancia Cinemagnética , Miocardio , Humanos , Imagen por Resonancia Magnética , Masculino , Valor Predictivo de las Pruebas , Diálisis Renal , Volumen Sistólico , Función Ventricular Izquierda
10.
J Cardiovasc Magn Reson ; 23(1): 82, 2021 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-34134696

RESUMEN

BACKGROUND: Quantitative myocardial perfusion mapping using cardiovascular magnetic resonance (CMR) is validated for myocardial blood flow (MBF) estimation in native vessel coronary artery disease (CAD). Following coronary artery bypass graft (CABG) surgery, perfusion defects are often detected in territories supplied by the left internal mammary artery (LIMA) graft, but their interpretation and subsequent clinical management is variable. METHODS: We assessed myocardial perfusion using quantitative CMR perfusion mapping in 38 patients with prior CABG surgery, all with angiographically-proven patent LIMA grafts to the left anterior descending coronary artery (LAD) and no prior infarction in the LAD territory. Factors potentially determining MBF in the LIMA-LAD myocardial territory, including the impact of delayed contrast arrival through the LIMA graft were evaluated. RESULTS: Perfusion defects were reported on blinded visual analysis in the LIMA-LAD territory in 27 (71%) cases, despite LIMA graft patency and no LAD infarction. Native LAD chronic total occlusion (CTO) was a strong independent predictor of stress MBF (B = - 0.41, p = 0.014) and myocardial perfusion reserve (MPR) (B = - 0.56, p = 0.005), and was associated with reduced stress MBF in the basal (1.47 vs 2.07 ml/g/min; p = 0.002) but not the apical myocardial segments (1.52 vs 1.87 ml/g/min; p = 0.057). Extending the maximum arterial time delay incorporated in the quantitative perfusion algorithm, resulted only in a small increase (3.4%) of estimated stress MBF. CONCLUSIONS: Perfusion defects are frequently detected in LIMA-LAD subtended territories post CABG despite LIMA patency. Although delayed contrast arrival through LIMA grafts causes a small underestimation of MBF, perfusion defects are likely to reflect true reductions in myocardial blood flow, largely due to proximal native LAD disease.


Asunto(s)
Puente de Arteria Coronaria , Arterias Mamarias , Puente de Arteria Coronaria/efectos adversos , Humanos , Isquemia , Espectroscopía de Resonancia Magnética , Arterias Mamarias/diagnóstico por imagen , Arterias Mamarias/cirugía , Perfusión , Valor Predictivo de las Pruebas
11.
Eur Heart J ; 41(29): 2759-2767, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32267922

RESUMEN

AIMS: Cardiac amyloidosis is common in elderly patients with aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI). We hypothesized that patients with dual aortic stenosis and cardiac amyloid pathology (AS-amyloid) would have different baseline characteristics, periprocedural and mortality outcomes. METHODS AND RESULTS: Patients aged ≥75 with severe AS referred for TAVI at two sites underwent blinded bone scintigraphy prior to intervention (Perugini Grade 0 negative, 1-3 increasingly positive). Baseline assessment included echocardiography, electrocardiogram (ECG), blood tests, 6-min walk test, and health questionnaire, with periprocedural complications and mortality follow-up. Two hundred patients were recruited (aged 85 ± 5 years, 50% male). AS-amyloid was found in 26 (13%): 8 Grade 1, 18 Grade 2. AS-amyloid patients were older (88 ± 5 vs. 85 ± 5 years, P = 0.001), with reduced quality of life (EQ-5D-5L 50 vs. 65, P = 0.04). Left ventricular wall thickness was higher (14 mm vs. 13 mm, P = 0.02), ECG voltages lower (Sokolow-Lyon 1.9 ± 0.7 vs. 2.5 ± 0.9 mV, P = 0.03) with lower voltage/mass ratio (0.017 vs. 0.025 mV/g/m2, P = 0.03). High-sensitivity troponin T and N-terminal pro-brain natriuretic peptide were higher (41 vs. 21 ng/L, P < 0.001; 3702 vs. 1254 ng/L, P = 0.001). Gender, comorbidities, 6-min walk distance, AS severity, prevalence of disproportionate hypertrophy, and post-TAVI complication rates (38% vs. 35%, P = 0.82) were the same. At a median follow-up of 19 (10-27) months, there was no mortality difference (P = 0.71). Transcatheter aortic valve implantation significantly improved outcome in the overall population (P < 0.001) and in those with AS-amyloid (P = 0.03). CONCLUSIONS: AS-amyloid is common and differs from lone AS. Transcatheter aortic valve implantation significantly improved outcome in AS-amyloid, while periprocedural complications and mortality were similar to lone AS, suggesting that TAVI should not be denied to patients with AS-amyloid.


Asunto(s)
Amiloidosis , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Prevalencia , Calidad de Vida , Factores de Riesgo , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
J Cardiovasc Magn Reson ; 22(1): 86, 2020 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-33308240

RESUMEN

BACKGROUND: Myocardial fibrosis occurs in end-stage heart failure secondary to mitral regurgitation (MR), but it is not known whether this is present before onset of symptoms or myocardial dysfunction. This study aimed to characterise myocardial fibrosis in chronic severe primary MR on histology, compare this to tissue characterisation on cardiovascular magnetic resonance (CMR) imaging, and investigate associations with symptoms, left ventricular (LV) function, and exercise capacity. METHODS: Patients with class I or IIa indications for surgery underwent CMR and cardiopulmonary exercise testing. LV biopsies were taken at surgery and the extent of fibrosis was quantified on histology using collagen volume fraction (CVFmean) compared to autopsy controls without cardiac pathology. RESULTS: 120 consecutive patients (64 ± 13 years; 71% male) were recruited; 105 patients underwent MV repair while 15 chose conservative management. LV biopsies were obtained in 86 patients (234 biopsy samples in total). MR patients had more fibrosis compared to 8 autopsy controls (median: 14.6% [interquartile range 7.4-20.3] vs. 3.3% [2.6-6.1], P < 0.001); this difference persisted in the asymptomatic patients (CVFmean 13.6% [6.3-18.8], P < 0.001), but severity of fibrosis was not significantly higher in NYHA II-III symptomatic MR (CVFmean 15.7% [9.9-23.1] (P = 0.083). Fibrosis was patchy across biopsy sites (intraclass correlation 0.23, 95% CI 0.08-0.39, P = 0.001). No significant relationships were identified between CVFmean and CMR tissue characterisation [native T1, extracellular volume (ECV) or late gadolinium enhancement] or measures of LV function [LV ejection fraction (LVEF), global longitudinal strain (GLS)]. Although the range of ECV was small (27.3 ± 3.2%), ECV correlated with multiple measures of LV function (LVEF: Rho = - 0.22, P = 0.029, GLS: Rho = 0.29, P = 0.003), as well as NTproBNP (Rho = 0.54, P < 0.001) and exercise capacity (%PredVO2max: R = - 0.22, P = 0.030). CONCLUSIONS: Patients with chronic primary MR have increased fibrosis before the onset of symptoms. Due to the patchy nature of fibrosis, CMR derived ECV may be a better marker of global myocardial status. Clinical trial registration Mitral FINDER study; Clinical Trials NCT02355418, Registered 4 February 2015, https://clinicaltrials.gov/ct2/show/NCT02355418.


Asunto(s)
Imagen por Resonancia Cinemagnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Miocardio/patología , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Enfermedades Asintomáticas , Biopsia , Estudios de Casos y Controles , Enfermedad Crónica , Progresión de la Enfermedad , Inglaterra , Prueba de Esfuerzo , Tolerancia al Ejercicio , Femenino , Fibrosis , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Índice de Severidad de la Enfermedad
14.
Circulation ; 138(18): 1935-1947, 2018 10 30.
Artículo en Inglés | MEDLINE | ID: mdl-30002099

RESUMEN

BACKGROUND: Aortic valve replacement (AVR) for aortic stenosis is timed primarily on the development of symptoms, but late surgery can result in irreversible myocardial dysfunction and additional risk. The aim of this study was to determine whether the presence of focal myocardial scar preoperatively was associated with long-term mortality. METHODS: In a longitudinal observational outcome study, survival analysis was performed in patients with severe aortic stenosis listed for valve intervention at 6 UK cardiothoracic centers. Patients underwent preprocedural echocardiography (for valve severity assessment) and cardiovascular magnetic resonance for ventricular volumes, function and scar quantification between January 2003 and May 2015. Myocardial scar was categorized into 3 patterns (none, infarct, or noninfarct patterns) and quantified with the full width at half-maximum method as percentage of the left ventricle. All-cause mortality and cardiovascular mortality were tracked for a minimum of 2 years. RESULTS: Six hundred seventy-four patients with severe aortic stenosis (age, 75±14 years; 63% male; aortic valve area, 0.38±0.14 cm2/m2; mean gradient, 46±18 mm Hg; left ventricular ejection fraction, 61.0±16.7%) were included. Scar was present in 51% (18% infarct pattern, 33% noninfarct). Management was surgical AVR (n=399) or transcatheter AVR (n=275). During follow-up (median, 3.6 years), 145 patients (21.5%) died (52 after surgical AVR, 93 after transcatheter AVR). In multivariable analysis, the factors independently associated with all-cause mortality were age (hazard ratio [HR], 1.50; 95% CI, 1.11-2.04; P=0.009, scaled by epochs of 10 years), Society of Thoracic Surgeons score (HR, 1.12; 95% CI, 1.03-1.22; P=0.007), and scar presence (HR, 2.39; 95% CI, 1.40-4.05; P=0.001). Scar independently predicted all-cause (26.4% versus 12.9%; P<0.001) and cardiovascular (15.0% versus 4.8%; P<0.001) mortality, regardless of intervention (transcatheter AVR, P=0.002; surgical AVR, P=0.026 [all-cause mortality]). Every 1% increase in left ventricular myocardial scar burden was associated with 11% higher all-cause mortality hazard (HR, 1.11; 95% CI, 1.05-1.17; P<0.001) and 8% higher cardiovascular mortality hazard (HR, 1.08; 95% CI, 1.01-1.17; P<0.001). CONCLUSIONS: In patients with severe aortic stenosis, late gadolinium enhancement on cardiovascular magnetic resonance was independently associated with mortality; its presence was associated with a 2-fold higher late mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/patología , Miocardio/patología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Cicatriz , Medios de Contraste/química , Ecocardiografía , Femenino , Gadolinio/química , Humanos , Estimación de Kaplan-Meier , Estudios Longitudinales , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
15.
Am Heart J ; 212: 91-100, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30978556

RESUMEN

BACKGROUND: The optimal timing of aortic valve replacement in asymptomatic patients with aortic stenosis is uncertain. Replacement fibrosis, as assessed by midwall (nonischemic) late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) imaging, is an irreversible marker of left ventricular decompensation in aortic stenosis. Once established, it progresses rapidly and is associated with poor long-term prognosis in a dose-dependent manner. TRIAL DESIGN: The objective of this multicenter prospective randomized controlled trial is to determine whether early aortic valve replacement in asymptomatic patients with severe aortic stenosis can improve the adverse prognosis associated with midwall LGE. Patients will be screened for likelihood of having LGE with electrocardiography or high-sensitivity troponin I. Those at high risk will proceed to CMR imaging. Approximately 400 patients with midwall LGE will be randomized 1:1 to early valve replacement or routine care. Those who do not exhibit midwall LGE will continue with routine care and be randomized to a study registry or no further follow-up. Follow-up will be annual for approximately 3 years until the number of required outcome events is achieved. The primary endpoint is a composite of all-cause mortality and unplanned aortic stenosis-related hospitalization. The expected event rate is 25.0% in the routine care arm and 13.4% in the early intervention arm over the first 2 years; 88 observed primary outcome events will give 90% power at 5% significance level. Key secondary endpoints include all-cause mortality, sudden cardiac death, stroke, and symptomatic status. CONCLUSION: The EVOLVED trial is the first multicenter randomized controlled trial to compare early aortic valve replacement to routine care in asymptomatic patients with severe aortic stenosis and midwall LGE.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Válvula Aórtica/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hipertrofia Ventricular Izquierda/diagnóstico , Imagen por Resonancia Cinemagnética/métodos , Miocardio/patología , Función Ventricular Izquierda/fisiología , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Enfermedades Asintomáticas , Ecocardiografía , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Hipertrofia Ventricular Izquierda/etiología , Hipertrofia Ventricular Izquierda/fisiopatología , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Índice de Severidad de la Enfermedad
17.
Eur Heart J ; 39(8): 699-709, 2018 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-29020257

RESUMEN

Aims: To investigate myocardial fibrosis (MF) in a large series of severe aortic stenosis (AS) patients using invasive biopsy and non-invasive imaging. Methods and results: One hundred thirty-three patients with severe, symptomatic AS accepted for surgical aortic valve replacement underwent cardiovascular magnetic resonance (CMR) with late gadolinium enhancement (LGE) and extracellular volume fraction (ECV) quantification. Intra-operative left ventricular (LV) biopsies were performed by needle or scalpel, yielding tissue with (n = 53) and without endocardium (n = 80), and compared with 10 controls. Myocardial fibrosis occurred in three patterns: (i) thickened endocardium with a fibrotic layer; (ii) microscopic scars, with a subendomyocardial predominance; and (iii) diffuse interstitial fibrosis. Collagen volume fraction (CVF) was elevated (P < 0.001) compared with controls, and higher (P < 0.001) in endocardium-containing samples with a decreasing CVF gradient from the subendocardium (P = 0.001). Late gadolinium enhancement correlated with CVF (P < 0.001) but not ECV. Both LGE and ECV correlated independently (P < 0.001) with N-terminal pro-brain natriuretic peptide and high-sensitivity-troponin T. High ECV was also associated with worse LV remodelling, left ventricular ejection fraction and functional capacity. Combining high ECV and LGE better identified patients with more adverse LV remodelling, blood biomarkers and histological parameters, and worse functional capacity than each parameter alone. Conclusion: Myocardial fibrosis in severe AS is complex, but three main patterns exist: endocardial fibrosis, microscars (mainly in the subendomyocardium), and diffuse interstitial fibrosis. Neither histological CVF nor the CMR parameters ECV and LGE capture fibrosis in its totality. A combined, multi-parametric approach with ECV and LGE allows best stratification of AS patients according to the response of the myocardial collagen matrix.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cardiomiopatías/patología , Ventrículos Cardíacos/cirugía , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/metabolismo , Factor Natriurético Atrial/metabolismo , Biopsia , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/metabolismo , Femenino , Gadolinio/metabolismo , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Precursores de Proteínas/metabolismo , Troponina T/metabolismo
18.
J Magn Reson Imaging ; 47(6): 1677-1684, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29159946

RESUMEN

BACKGROUND: Extracellular volume (ECV) by T1 mapping requires the contrast agent distribution to be at equilibrium. This can be achieved either definitively with a primed contrast infusion (infusion ECV), or sufficiently with a delay postbolus (bolus-only ECV). For large ECV, the bolus-only approach measures higher than the infusion ECV, causing some uncertainty in diseases such as amyloidosis. PURPOSE: To characterize the relationship between the bolus-only and current gold-standard infusion ECV in patients with amyloidosis. STUDY TYPE: Bolus-only and infusion ECV were prospectively measured. POPULATION: In all, 186 subjects with systemic amyloidosis attending our clinic and 23 subjects with systemic amyloidosis who were participating in an open-label, two-part, dose-escalation, phase 1 trial. FIELD STRENGTH: Avanto 1.5T, Siemens Medical Solutions, Erlangen, Germany. ASSESSMENT: Bolus-only and infusion ECV were measured in all subjects using shortened modified Look-Locker inversion recovery (ShMOLLI) T1 mapping sequence. STATISTICAL TESTS: Pearson correlation coefficient (r); Bland-Altman; receiver operating characteristic (ROC) curve analysis. Linear regression model with a fractional polynomial transformation. RESULTS: The difference between the bolus-only and infusion myocardial ECV increased as the average of the two measures increased, with the bolus-ECV measuring higher. For an average ECV of 0.4, the difference was 0.013. The 95% limits of agreement for the two methods, after adjustment for the bias, were ±0.056. However, cardiac diagnostic accuracy was comparable (bolus-only vs. infusion ECV area under the curve [AUC] = 0.839 vs. 0.836), as were correlations with other clinical cardiac measures, and, in the trial patients, the ability to track changes in the liver/spleen with therapy. DATA CONCLUSION: In amyloidosis, with large ECVs, the bolus-only technique reads higher than the infusion technique, but clinical performance by any measure is the same. Given the work-flow advantages, these data suggest that the bolus-only approach might be acceptable for amyloidosis, and might support its use as a surrogate endpoint in future clinical trials. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2018;47:1677-1684.


Asunto(s)
Amiloide/química , Proteínas Amiloidogénicas/química , Amiloidosis/diagnóstico por imagen , Corazón/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Anciano , Amiloidosis/patología , Área Bajo la Curva , Biopsia , Medios de Contraste , Femenino , Fibrosis , Humanos , Cinética , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Miocardio/patología , Estudios Prospectivos , Análisis de Regresión , Reproducibilidad de los Resultados , Bazo/diagnóstico por imagen
19.
Curr Cardiol Rep ; 20(3): 15, 2018 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-29511861

RESUMEN

PURPOSE OF REVIEW: This review article discusses the evolution of extracellular volume (ECV) quantification using both cardiovascular magnetic resonance (CMR) and computed tomography (CT). RECENT FINDINGS: Visualizing diffuse myocardial fibrosis is challenging and until recently, was restricted to the domain of the pathologist. CMR and CT both use extravascular, extracellular contrast agents, permitting ECV measurement. The evidence base around ECV quantification by CMR is growing rapidly and just starting in CT. In conditions with high ECV (amyloid, oedema and fibrosis), this technique is already being used clinically and as a surrogate endpoint. Non-invasive diffuse fibrosis quantification is also generating new biological insights into key cardiac diseases. CMR and CT can estimate ECV and in turn diffuse myocardial fibrosis, obviating the need for invasive endomyocardial biopsy. CT is an attractive alternative to CMR particularly in those individuals with contraindications to the latter. Further studies are needed, particularly in CT.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Matriz Extracelular/patología , Corazón/diagnóstico por imagen , Infarto del Miocardio/patología , Miocardio/patología , Cardiomiopatía Hipertrófica/patología , Medios de Contraste , Fibrosis , Gadolinio DTPA , Insuficiencia Cardíaca/patología , Humanos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA