Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 19(23)2019 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-31766519

RESUMEN

In this paper, we demonstrate an innovative electromagnetic targeting system utilizing a passive magnetic-flux-concentrator for tracking endobronchoscope used in the diagnosis process of lung cancer tumors/lesions. The system consists of a magnetic-flux emitting coil, a magnetic-flux receiving electromagnets-array, and high permeability silicon-steel sheets rolled as a collar (as the passive magnetic-flux-concentrator) fixed in a guide sheath of an endobronchoscope. The emitting coil is used to produce AC magnetic-flux, which is consequently received by the receiving electromagnets-array. Due to the electromagnetic-induction, a voltage is induced in the receiving electromagnets-array. When the endobronchoscope's guide sheath (with the silicon-steel collar) travels between the emitting coil and the receiving electromagnets-arrays, the magnetic flux is concentrated by the silicon-steel collar and thereby the induced voltage is changed. Through analyzing the voltage-pattern change, the location of the silicon-steel collar with the guide sheath is targeted. For testing, a bronchial-tree model for training medical doctors and operators is used to test our system. According to experimental results, the system is successfully verified to be able to target the endobronchoscope in the bronchial-tree model. The targeting errors on the x-, y- and z-axes are 9 mm, 10 mm, and 5 mm, respectively.


Asunto(s)
Broncoscopía/instrumentación , Fenómenos Electromagnéticos , Humanos , Neoplasias Pulmonares/diagnóstico , Silicio/química , Acero/química
2.
Electrophoresis ; 35(16): 2392-400, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24610717

RESUMEN

A battery-powered portable instrument system for the single-HeLa-cell trapping and analyses is developed. A method of alternating current electrothermal (ACET) and DEP are employed for the cell trapping and the method of impedance spectroscopy is employed for cell characterizations. The proposed instrument (160 mm × 170 mm × 110 mm, 1269 g) equips with a highly efficient energy-saving design that promises approximately 120 h of use. It includes an impedance analyzer performing an excitation voltage of 0.2-2 Vpp and a frequency sweep of 11-101 kHz, function generator with the sine wave output at an operating voltage of 1-50 Vpp with a frequency of 4-12 MHz, cell-trapping biochip, microscope, and input/output interface. The biochip for the single cell trapping is designed and simulated based on a combination of ACET and DEP forces. In order to improve measurement accuracy, the curve fitting method is adopted to calibrate the proposed impedance spectroscopy. Measurement results from the proposed system are compared with results from a precision impedance analyzer. The trapped cell can be modeled for numerical analyses. Many advantages are offered in the proposed instrument such as the small volume, real-time monitoring, rapid analysis, low cost, low-power consumption, and portable application.


Asunto(s)
Espectroscopía Dieléctrica/instrumentación , Análisis de la Célula Individual/instrumentación , Análisis de Matrices Tisulares/instrumentación , Impedancia Eléctrica , Diseño de Equipo , Células HeLa , Humanos , Programas Informáticos
3.
Electrophoresis ; 32(11): 1337-47, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21538398

RESUMEN

This work presents a microfluidic system that can transport, concentrate, and capture particles in a controllable droplet. Dielectrophoresis (DEP), a phenomenon in which a force is exerted on a dielectric particle when it is subjected to a non-uniform electric field, is used to manipulate particles. Liquid dielectrophoresis (LDEP), a phenomenon in which a liquid moves toward regions of high electric field strength under a non-uniform electric field, is used to manipulate the fluid. In this study, a mechanism of droplet creation presented in a previous work that uses DEP and LDEP is improved. A driving electrode with a DEP gap is used to prevent beads from getting stuck at the interface between air and liquid, which is actuated with an AC signal of 200 V(pp) at a frequency of 100 kHz. DEP theory is used to calculate the DEP force in the liquid, and LDEP theory is used to analyze the influence of the DEP gap. The increment of the actuation voltage due to the electrode with a DEP gap is calculated. A set of microwell electrodes is used to capture a bead using DEP force, which is actuated with an AC signal of 20 V(pp) at a frequency of 5 MHz. A simulation is carried out to investigate the dimensions of the DEP gap and microwell electrodes. Experiments are performed to demonstrate the creation of a 100-nL droplet and the capture of individual 10-µm polystyrene latex beads in the droplet.


Asunto(s)
Electroforesis/métodos , Microfluídica/métodos , Modelos Químicos , Simulación por Computador , Electrodos , Análisis de Elementos Finitos , Microesferas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA