Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39066601

RESUMEN

Prediction of bone fracture risk is clinically challenging. Computational modeling plays a vital role in understanding bone structure and diagnosing bone diseases, leading to novel therapies. The research objectives were to demonstrate the anisotropic structure of the bone at the micro-level taking into consideration the density and subject demography, such as age, gender, body mass index (BMI), height, weight, and their roles in damage accumulation. Out of 438 developed 3D bone models at the micro-level, 46.12% were female. The age distribution ranged from 23 to 95 years. The research unfolds in two phases: micro-morphological features examination and stress distribution investigation. Models were developed using Mimics 22.0 and SolidWorks. The anisotropic material properties were defined before importing into Ansys for simulation. Computational simulations further uncovered variations in maximum von-Misses stress, highlighting that young Black males experienced the highest stress at 127.852 ± 10.035 MPa, while elderly Caucasian females exhibited the least stress at 97.224 ± 14.504 MPa. Furthermore, age-related variations in stress levels for both normal and osteoporotic bone micro models were elucidated, emphasizing the intricate interplay of demographic factors in bone biomechanics. Additionally, a prediction equation for bone density incorporating demographic variables was proposed, offering a personalized modeling approach. In general, this study, which carefully examines the complexities of how bones behave at the micro-level, emphasizes the need for an enhanced approach in orthopedics. We suggest taking individual characteristics into account to make therapeutic interventions more precise and effective.

2.
Bioengineering (Basel) ; 10(10)2023 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-37892942

RESUMEN

Even though total ankle replacement has emerged as an alternative treatment to arthrodesis, the long-term clinical results are unsatisfactory. Proper design of the ankle device is required to achieve successful arthroplasty results. Therefore, a quantitative knowledge of the ankle joint is necessary. In this pilot study, imaging data of 22 subjects (with both females and males and across three age groups) was used to measure the morphological parameters of the ankle joint. A total of 40 measurements were collected by creating sections in the sagittal and coronal planes for the tibia and talus. Statistical analyses were performed to compare genders, age groups, and image acquisition techniques used to generate 3D models. About 13 measurements derived for parameters (TiAL, SRTi, TaAL, SRTa, TiW, TaW, and TTL) that are very critical for the implant design showed significant differences (p-value < 0.05) between males and females. Young adults showed a significant difference (p-value < 0.05) compared to adults for 15 measurements related to critical tibial and talus parameters (TiAL, TiW, TML, TaAL, SRTa, TaW, and TTL), but no significant differences were observed between young adults and older adults, and between adults and older adults for most of the parameters. A positive correlation (r > 0.70) was observed between tibial and talar width values and between the sagittal radius values. When compared with morphological parameters obtained in this study, the sizes of current total ankle replacement devices can only fit a very limited group of people in this study. This pilot study contributes to the comprehensive understanding of the effects of gender and age group on ankle joint morphology and the relationship between tibial and talus parameters that can be used to plan and design ankle devices.

3.
Bioengineering (Basel) ; 9(1)2021 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-35049718

RESUMEN

The main motivation for studying damage in bone tissue is to better understand how damage develops in the bone tissue and how it progresses. Such knowledge may help in the surgical aspects of joint replacement, fracture fixation or establishing the fracture tolerance of bones to prevent injury. Currently, there are no standards that create a realistic bone model with anisotropic material properties, although several protocols have been suggested. This study seeks to retrospectively evaluate the damage of bone tissue with respect to patient demography including age, gender, race, body mass index (BMI), height, and weight, and their role in causing fracture. Investigators believe that properties derived from CT imaging data to estimate the material properties of bone tissue provides more realistic models. Quantifying and associating damage with in vivo conditions will provide the required information to develop mathematical equations and procedures to predict the premature failure and potentially mitigate problems before they begin. Creating a realistic model for bone tissue can predict the premature failure(s), provide preliminary results before getting the surgery, and optimize the design of orthopaedic implants. A comparison was performed between the proposed model and previous efforts, where they used elastic, hyper- elastic, or elastic-plastic properties. Results showed that there was a significant difference between the anisotropic material properties of bone when compared with unrealistic previous methods. The results showed that the density is 50% higher in male subjects than female subjects. Additionally, the results showed that the density is 47.91% higher in Black subjects than Mixed subjects, 53.27% higher than Caucasian subjects and 57.41% higher than Asian. In general, race should be considered during modeling implants or suggesting therapeutic techniques.

4.
J Mech Behav Biomed Mater ; 44: 202-23, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25676360

RESUMEN

BACKGROUND: There are several factors that contribute to the failure of total ankle replacement (TAR). Aseptic loosening is one of the primary mechanisms of failure in TAR. Since a cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is used as liner material, there is a need to quantify and develop methods to estimate the wear rates of the liners. High contact stresses develop during the gait generates wear debris resulting in osteolysis and early loosening of the prostheses. METHODS: In this paper wear characteristics of Wright State University (WSU) TARs were determined by applying shear and torsion loads. Viscoelastic properties were used to model the liner component. Finite element analysis was conducted to determine the wear rate by deriving Von Mises and contact stresses generated in the liner and wear rate equation was used to predict the wear rate. RESULTS: Titanium alloy has shown less resistance towards shear forces when compared with other metal alloys. Under torsion, rotation angle plays a significant role in affecting the peak stress values. The maximum average contact stress was 14.46 MPa under torsion load which contributes to a wear rate of 0.67 (mm(3)/year) for one of the mobile bearing models. The maximum average contact stress and wear rate obtained from the analytical study were 10.55 MPa and 0.33 (mm(3)/year), respectively for mobile bearing models. When compared with mobile bearing model, fixed bearing model has shown higher stresses at different degrees of rotation. CONCLUSION: Both shear and torsion loads cause significantly lower contact stresses and wear when compared to the axial load. Further studies are necessary to accurately determine the wear behavior of fixed bearing TAR models.


Asunto(s)
Artroplastia de Reemplazo de Tobillo/instrumentación , Ensayo de Materiales , Resistencia al Corte , Soporte de Peso , Aleaciones , Análisis de Elementos Finitos , Marcha , Humanos , Falla de Prótesis , Rotación , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA