Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 59(1): 32-42, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37288953

RESUMEN

Zero echo time (ZTE) sequence is recent advanced magnetic resonance technique that utilizes ultrafast readouts to capture signals from short-T2 tissues. This sequence enables T2- and T2* weighted imaging of tissues with short intrinsic relaxation times by using an extremely short TE, and are increasingly used in the musculoskeletal system. We review the imaging physics of these sequences, practical limitations, and image reconstruction, and then discuss the clinical utilities in various disorders of the musculoskeletal system. ZTE can be readily incorporated into the clinical workflow, and is a promising technique to avoid unnecessary radiation exposure, cost, and time-consuming by computed tomography in some cases. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Sistema Musculoesquelético , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Sistema Musculoesquelético/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos
2.
Pediatr Radiol ; 54(5): 715-724, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38285191

RESUMEN

BACKGROUND: The mediastinal shift angle is a new fetal magnetic resonance imaging (MRI) index that is reportedly correlated with postnatal survival in fetuses with congenital diaphragmatic hernia. However, its correlation in patients with congenital pulmonary airway malformation (CPAM) has not been assessed. OBJECTIVE: This study aimed to establish a normal range for the right/left mediastinal shift angles, to evaluate the mediastinal shift angle in fetuses with CPAM, to compare the mediastinal shift angle with the CPAM volume ratio, and to evaluate the predictive value of the mediastinal shift angle measurements. MATERIALS AND METHODS: To establish the normal range, we measured the mediastinal shift angle bilaterally in 124 fetuses without any lung abnormality (the control group). Subsequently, the mediastinal shift angle was measured in 32 fetuses pathologically diagnosed with CPAM. Moreover, the mediastinal shift angle and CPAM volume ratio were compared using fetal MRI. RESULTS: The mean values for the right/left mediastinal shift angles were 18.6°/26.3° and 39.2°/35.9° for control fetuses and fetuses with CPAM, respectively. The mediastinal shift angle and the CPAM volume ratio showed a positive statistical correlation. The area under the curve demonstrated high discriminatory accuracy for the mediastinal shift angle (0.76). CONCLUSION: The mediastinal shift angle has potential to replace the CPAM volume ratio for evaluating the severity of CPAM in fetal MRI.


Asunto(s)
Imagen por Resonancia Magnética , Diagnóstico Prenatal , Humanos , Femenino , Imagen por Resonancia Magnética/métodos , Diagnóstico Prenatal/métodos , Embarazo , Mediastino/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Pulmón/anomalías , Pulmón/embriología , Malformación Adenomatoide Quística Congénita del Pulmón/diagnóstico por imagen , Valores de Referencia , Estudios Retrospectivos
3.
AJNR Am J Neuroradiol ; 45(8): 1141-1152, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-38871365

RESUMEN

BACKGROUND AND PURPOSE: Parkinson disease is a prevalent disease, with olfactory dysfunction recognized as an early nonmotor manifestation. It is sometimes difficult to differentiate Parkinson disease from atypical parkinsonism using conventional MR imaging and motor symptoms. It is also known that olfactory loss occurs to a lesser extent or is absent in atypical parkinsonism. To the best of our knowledge, no study has examined olfactory bulb changes to differentiate Parkinson disease from atypical parkinsonism, even in an early diagnosis, and its association with conventional MR imaging findings. Hence, we aimed to assess the utility of olfactory bulb measurements in differentiating Parkinson disease from atypical parkinsonism even in the early stage. MATERIALS AND METHODS: In this retrospective study, we enrolled 108 patients with Parkinson disease, 13 with corticobasal syndrome, 15 with multiple system atrophy, and 17 with progressive supranuclear palsy who developed parkinsonism. Thirty-nine age-matched healthy subjects served as controls. All subjects underwent conventional MR imaging and 3D FIESTA for olfactory bulb measurements using manual ROI quantification of the cross-sectional olfactory bulb area using the coronal plane. Bilateral olfactory bulb measurements were averaged. For group comparisons, we used the Welch t test, and we assessed diagnostic accuracy using receiver operating characteristic analysis. RESULTS: Patients with Parkinson disease had a mean olfactory bulb area of 4.2 (SD, 1.0 mm2), significantly smaller than in age-matched healthy subjects (6.6 [SD, 1.7 mm2], P < .001), and those with corticobasal syndrome (5.4 [SD, 1.2 mm2], P < .001), multiple system atrophy (6.5 [SD, 1.2 mm2], P < .001), and progressive supranuclear palsy (5.4 [SD, 1.2 mm2], P < .001). The receiver operating characteristic analysis for the olfactory bulb area measurements showed good diagnostic performance in differentiating Parkinson disease from atypical parkinsonism, with an area under the curve of 0.87, an optimal cutoff value of 5.1 mm2, and a false-positive rate of 18%. When we compared within 2 years of symptom onset, the olfactory bulb in Parkinson disease (4.2 [SD, 1.1 mm2]) remained significantly smaller than in atypical parkinsonism (versus corticobasal syndrome (6.1 [SD, 0.7 mm2]), P < .001; multiple system atrophy (6.3 [SD, 1.4 mm2]), P < .001; and progressive supranuclear palsy (5.2 [1.3 mm2], P = .003, respectively). CONCLUSIONS: 3D FIESTA-based olfactory bulb measurement holds promise for distinguishing Parkinson disease from atypical parkinsonism, especially in the early stage.


Asunto(s)
Imagen por Resonancia Magnética , Bulbo Olfatorio , Enfermedad de Parkinson , Trastornos Parkinsonianos , Humanos , Bulbo Olfatorio/diagnóstico por imagen , Bulbo Olfatorio/patología , Masculino , Femenino , Enfermedad de Parkinson/diagnóstico por imagen , Anciano , Diagnóstico Diferencial , Estudios Retrospectivos , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Trastornos Parkinsonianos/diagnóstico por imagen , Imagenología Tridimensional/métodos , Sensibilidad y Especificidad , Parálisis Supranuclear Progresiva/diagnóstico por imagen , Atrofia de Múltiples Sistemas/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA