Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Ultrasound Med ; 43(4): 781-788, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38189552

RESUMEN

OBJECTIVES: To describe the ultrasonographic features of nail lichen planus (NLP), which, so far, have not been reported in the literature. METHODS: A retrospective single-center study of NLP patients' color Doppler ultrasound examinations was performed between March 2014 and January 2023. Inclusion criteria were patients ≥15 years with a confirmed clinical diagnosis of NLP in sequential order. Exclusion criteria included concomitant systemic or local cutaneous or nail diseases and systemic or local nail treatments before the ultrasound examination. The ultrasound protocol included the examination of all fingernails or toenails following the reported protocol for dermatologic ultrasound examinations at high and ultra-high frequencies. Patient demographics and ultrasound features of the nail bed, periungual region, nail plate, and regional vascularity were registered and analyzed statistically. RESULTS: A total of 36 patients met the criteria. All cases presented thickened and decreased echogenicity of the nail bed. A hypoechoic halo surrounding the origin of the nail plate was present in 78% of cases. Exactly 58% of patients presented decreased echogenicity of the proximal periungual dermis, and 86% showed thickening of the periungual dermis. Hypervascularity of the nail bed was seen in 94% of cases. The mean maximum thickness of vessels, the peak systolic velocity of the arterial vessels, and other blood flow findings are provided. CONCLUSION: Ultrasonography can support the diagnosis of NLP, which benefits the non-invasive discrimination of nail conditions and can avoid the potential permanent scars derived from nail biopsies. Furthermore, ultrasound may be a powerful tool to monitor this disease's treatment.


Asunto(s)
Liquen Plano , Enfermedades de la Uña , Humanos , Estudios Retrospectivos , Enfermedades de la Uña/diagnóstico por imagen , Uñas/diagnóstico por imagen , Liquen Plano/diagnóstico por imagen , Liquen Plano/tratamiento farmacológico , Ultrasonografía/métodos
2.
Eur Radiol ; 33(2): 1102-1111, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36029344

RESUMEN

OBJECTIVES: Establishing the reproducibility of expert-derived measurements on CTA exams of aortic dissection is clinically important and paramount for ground-truth determination for machine learning. METHODS: Four independent observers retrospectively evaluated CTA exams of 72 patients with uncomplicated Stanford type B aortic dissection and assessed the reproducibility of a recently proposed combination of four morphologic risk predictors (maximum aortic diameter, false lumen circumferential angle, false lumen outflow, and intercostal arteries). For the first inter-observer variability assessment, 47 CTA scans from one aortic center were evaluated by expert-observer 1 in an unconstrained clinical assessment without a standardized workflow and compared to a composite of three expert-observers (observers 2-4) using a standardized workflow. A second inter-observer variability assessment on 30 out of the 47 CTA scans compared observers 3 and 4 with a constrained, standardized workflow. A third inter-observer variability assessment was done after specialized training and tested between observers 3 and 4 in an external population of 25 CTA scans. Inter-observer agreement was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. RESULTS: Pre-training ICCs of the four morphologic features ranged from 0.04 (-0.05 to 0.13) to 0.68 (0.49-0.81) between observer 1 and observers 2-4 and from 0.50 (0.32-0.69) to 0.89 (0.78-0.95) between observers 3 and 4. ICCs improved after training ranging from 0.69 (0.52-0.87) to 0.97 (0.94-0.99), and Bland-Altman analysis showed decreased bias and limits of agreement. CONCLUSIONS: Manual morphologic feature measurements on CTA images can be optimized resulting in improved inter-observer reliability. This is essential for robust ground-truth determination for machine learning models. KEY POINTS: • Clinical fashion manual measurements of aortic CTA imaging features showed poor inter-observer reproducibility. • A standardized workflow with standardized training resulted in substantial improvements with excellent inter-observer reproducibility. • Robust ground truth labels obtained manually with excellent inter-observer reproducibility are key to develop reliable machine learning models.


Asunto(s)
Disección Aórtica , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Disección Aórtica/diagnóstico por imagen , Aorta
6.
Radiol Case Rep ; 19(7): 2650-2653, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38645950

RESUMEN

Acute calcific longus colli tendinitis is a differential diagnosis of neck pain. Typical presentation consists in a triad of symptoms including acute onset neck pain, neck stiffness and odynophagia. Computed tomography (CT) is the gold standard for acute calcific longus colli tendinitis diagnosis and the main radiological findings include prevertebral soft tissue swelling and the presence of amorphous calcifications. The case involves a 39-year-old female who presented to the emergency department with acute unilateral cervical pain that resulted in acute calcific longus colli tendinitis.

7.
Radiol Cardiothorac Imaging ; 4(6): e220155, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36601454

RESUMEN

Limited aortic intimal tear is an uncommon lesion of the dissection spectrum. The lesion has several imaging features that are not well known, including asymmetric aortic contour abnormalities, filling defects, and various morphologic patterns, such as linear, L-shaped, T-shaped, and stellate configurations. Hemorrhage of the aortic wall may also be present in patients with this rare entity. This imaging essay reviews the CT imaging findings and clinical characteristics of patients with limited intimal tears. Keywords: Aorta, CT © RSNA, 2022.

8.
Radiol Cardiothorac Imaging ; 4(6): e220039, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36601455

RESUMEN

Purpose: To describe the design and methodological approach of a multicenter, retrospective study to externally validate a clinical and imaging-based model for predicting the risk of late adverse events in patients with initially uncomplicated type B aortic dissection (uTBAD). Materials and Methods: The Registry of Aortic Diseases to Model Adverse Events and Progression (ROADMAP) is a collaboration between 10 academic aortic centers in North America and Europe. Two centers have previously developed and internally validated a recently developed risk prediction model. Clinical and imaging data from eight ROADMAP centers will be used for external validation. Patients with uTBAD who survived the initial hospitalization between January 1, 2001, and December 31, 2013, with follow-up until 2020, will be retrospectively identified. Clinical and imaging data from the index hospitalization and all follow-up encounters will be collected at each center and transferred to the coordinating center for analysis. Baseline and follow-up CT scans will be evaluated by cardiovascular imaging experts using a standardized technique. Results: The primary end point is the occurrence of late adverse events, defined as aneurysm formation (≥6 cm), rapid expansion of the aorta (≥1 cm/y), fatal or nonfatal aortic rupture, new refractory pain, uncontrollable hypertension, and organ or limb malperfusion. The previously derived multivariable model will be externally validated by using Cox proportional hazards regression modeling. Conclusion: This study will show whether a recent clinical and imaging-based risk prediction model for patients with uTBAD can be generalized to a larger population, which is an important step toward individualized risk stratification and therapy.Keywords: CT Angiography, Vascular, Aorta, Dissection, Outcomes Analysis, Aortic Dissection, MRI, TEVAR© RSNA, 2022See also the commentary by Rajiah in this issue.

9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 3912-3915, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892087

RESUMEN

Patients with initially uncomplicated typeB aortic dissection (uTBAD) remain at high risk for developing late complications. Identification of morphologic features for improving risk stratification of these patients requires automated segmentation of computed tomography angiography (CTA) images. We developed three segmentation models utilizing a 3D residual U-Net for segmentation of the true lumen (TL), false lumen (FL), and false lumen thrombosis (FLT). Model 1 segments all labels at once, whereas model 2 segments them sequentially. Best results for TL and FL segmentation were achieved by model 2, with median (interquartiles) Dice similarity coefficients (DSC) of 0.85 (0.77-0.88) and 0.84 (0.82-0.87), respectively. For FLT segmentation, model 1 was superior to model 2, with median (interquartiles) DSCs of 0.63 (0.40-0.78). To purely test the performance of the network to segment FLT, a third model segmented FLT starting from the manually segmented FL, resulting in median (interquartiles) DSCs of 0.99 (0.98-0.99) and 0.85 (0.73-0.94) for patent FL and FLT, respectively. While the ambiguous appearance of FLT on imaging remains a significant limitation for accurate segmentation, our pipeline has the potential to help in segmentation of aortic lumina and thrombosis in uTBAD patients.Clinical relevance- Most predictors of aortic dissection (AD) degeneration are identified through anatomical modeling, which is currently prohibitive in clinical settings due to the timeintense human interaction. False lumen thrombosis, which often develops in patients with type B AD, has proven to show significant prognostic value for predicting late adverse events. Our automated segmentation algorithm offers the potential of personalized treatment for AD patients, leading to an increase in long-term survival.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Aprendizaje Profundo , Trombosis , Disección Aórtica/diagnóstico por imagen , Humanos , Estudios Retrospectivos , Trombosis/diagnóstico por imagen
10.
J Cardiovasc Comput Tomogr ; 15(5): 431-440, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33795188

RESUMEN

BACKGROUND: Identifying high-risk patients who will not derive substantial survival benefit from TAVR remains challenging. Pulmonary hypertension is a known predictor of poor outcome in patients undergoing TAVR and correlates strongly with pulmonary artery (PA) enlargement on CTA. We sought to evaluate whether PA enlargement, measured on pre-procedural computed tomography angiography (CTA), is associated with 1-year mortality in patients undergoing TAVR. METHODS: We retrospectively included 402 patients undergoing TAVR between July 2012 and March 2016. Clinical parameters, including Society of Thoracic Surgeons (STS) score and right ventricular systolic pressure (RVSP) estimated by transthoracic echocardiography were reviewed. PA dimensions were measured on pre-procedural CTAs. Association between PA enlargement and 1-year mortality was analyzed. Kaplan-Meier and Cox proportional hazards regression analyses were performed. RESULTS: The median follow-up time was 433 (interquartiles 339-797) days. A total of 56/402 (14%) patients died within 1 year after TAVR. Main PA area (area-MPA) was independently associated with 1-year mortality (hazard ratio per standard deviation equal to 2.04 [95%-confidence interval (CI) 1.48-2.76], p â€‹< â€‹0.001). Area under the curve (95%-CI) of the clinical multivariable model including STS-score and RVSP increased slightly from 0.67 (0.59-0.75) to 0.72 (0.72-0.89), p â€‹= â€‹0.346 by adding area-MPA. Although the AUC increased, differences were not significant (p â€‹= â€‹0.346). Kaplan-Meier analysis showed that mortality was significantly higher in patients with a pre-procedural non-indexed area-MPA of ≥7.40 â€‹cm2 compared to patients with a smaller area-MPA (mortality 23% vs. 9%; p â€‹< â€‹0.001). CONCLUSIONS: Enlargement of MPA on pre-procedural CTA is independently associated with 1-year mortality after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Angiografía por Tomografía Computarizada , Humanos , Estimación de Kaplan-Meier , Valor Predictivo de las Pruebas , Pronóstico , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA