Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38908746

RESUMEN

PURPOSE: To retrospectively investigate the safety and efficacy of percutaneous radiofrequency ablation (RFA) by analyzing results in patients with lung neoplasm accompanied by interstitial lung disease (ILD) on computed tomography (CT) in a multicenter study. MATERIALS & METHODS: Patients with lung neoplasm accompanied by ILD who underwent RFA between April 2002 and October 2017 at seven institutions were investigated. Technical success rate, and local tumor progression (LTP) of ablated tumors were evaluated. Adverse events including acute exacerbation of ILD were also evaluated. Univariate analyses were performed to identify factors associated with acute exacerbation. RESULTS: Forty-nine patients with 64 lung neoplasm (mean diameter, 22.6 mm; range, 4-58 mm) treated in 66 sessions were included. Usual interstitial pneumonia (UIP) pattern on CT was identified in 23 patients (47%). All patients underwent successful RFA. Acute exacerbations were seen in 5 sessions (8%: 7% with UIP pattern, 8% without) in 5 patients, all occurring on or after 8 days (median, 12 days; range, 8-30 days). Three of those 5 patients died of acute exacerbation. Treatment resulted in mortality after 5% of sessions, representing 6% of patients. Pleural effusion and fever ≥38°C after RFA were identified by univariate analysis (p = 0.0012, p = 0.02, respectively) as significant risk factors for acute exacerbation. The cumulative LTP rate was 43% at 1 year. CONCLUSIONS: RFA appears feasible for patients with lung neoplasm complicated by ILD. Acute exacerbation occurred in 8% of patients with symptoms occurring more than 8 days post-ablation and was associated with a 45% mortality rate.

2.
Curr Oncol Rep ; 26(5): 573-582, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38625653

RESUMEN

PURPOSE OF REVIEW: To review the current status of kidney tumor ablation in patients with substantial kidney impairment. RECENT FINDINGS: Few reports of kidney tumor ablation in such patients have recently been published. The reported prevalence of patients with stage 4 or 5 chronic kidney disease (CKD) among patients undergoing ablation is 2.0%-10%. In patients with stage 4 or 5 CKD, local tumor control rates were 88%-100%. The effect of ablation on CKD stage is unclear, and the observed deteriorations in kidney function are consistent with both the effect of cryoablation and the natural course of advanced CKD. According to guidelines, active surveillance may be selected. The goals of treatment are complete tumor removal and maintenance of kidney function, both of which can be met by ablation. Given the limited treatment options, ablation may play a pivotal role in the management of patients with advanced CKD.


Asunto(s)
Neoplasias Renales , Insuficiencia Renal Crónica , Humanos , Neoplasias Renales/cirugía , Neoplasias Renales/patología , Neoplasias Renales/complicaciones , Insuficiencia Renal Crónica/complicaciones , Criocirugía , Técnicas de Ablación/métodos
3.
Int J Clin Oncol ; 29(2): 81-88, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37115426

RESUMEN

Interventional oncology offers minimally invasive treatments for malignant tumors for curative and palliative purposes based on the percutaneous insertion of needles or catheters into the target location under image guidance. Robotic systems have been gaining increasing attention as tools that provide potential advantages for image-guided interventions. Among the robotic systems developed for intervention, those relevant to the oncology field are mainly those for guiding or driving the needles in non-vascular interventional procedures such as biopsy and tumor ablation. Needle-guiding robots support planning the needle path and align the needle robotically according to the planned trajectory, which is combined with subsequent manual needle insertion by the physician through the needle guide. Needle-driving robots can advance the needle robotically after determining its orientation. Although a wide variety of robotic systems have been developed, only a limited number of these systems have reached the clinical phase or commercialization thus far. The results of previous studies suggest that such interventional robots have the potential to increase the accuracy of needle placement, facilitate out-of-plane needle insertion, decrease the learning curve, and reduce radiation exposure. On the other hand, increased complexity and costs may be a concern when using robotic systems compared with conventional manual procedures. Further data should be collected to comprehensively assess the value of robotic systems in interventional oncology.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Agujas , Biopsia
4.
Acta Med Okayama ; 78(2): 135-142, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38688831

RESUMEN

This study aimed to evaluate the potential reduction in contrast medium utilization using photon-counting detector computed tomography (PCD-CT). One PCD-CT scan (CT1) and three conventional (non-PCD-CT) CT scans (CT2-CT4) were performed using a multi-energy CT phantom that contained eight rods with different iodine concentrations (0.2, 0.5, 1, 2, 5, 10, 15, and 20 mg/ml). The CT values of the seven groups (CT1 for 40, 50, 60, and 70 keV; and CT2-4) were measured. Noise and contrast-to-noise ratio (CNR) were assessed for the eight rods at various iodine concentrations. CT2 and CT1 (40 keV) respectively required 20 mg/ml and 5 mg/ml of iodine, indicating that a comparable contrast effect could be obtained with approximately one-fourth of the contrast medium amount. The standard deviation values increased at lower energy levels irrespective of the iodine concentration. The CNR exhibited a decreasing trend with lower iodine concentrations, while it remained relatively stable across all iodine levels (40-70 keV). This study demonstrated that virtual monochromatic 40 keV images offer a similar contrast effect with a reduced contrast medium amount when compared to conventional CT systems at 120 kV.


Asunto(s)
Medios de Contraste , Fantasmas de Imagen , Fotones , Tomografía Computarizada por Rayos X , Medios de Contraste/química , Tomografía Computarizada por Rayos X/métodos , Yodo , Humanos
5.
Minim Invasive Ther Allied Technol ; 33(3): 184-186, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38206125

RESUMEN

We report a case of postoperative pseudoaneurysm, successfully treated with selective arterial embolization, using a steerable microcatheter and triaxial system via retrograde approach. A pseudoaneurysm was detected in the dorsal pancreatic artery, a severely narrow and steeply inverted branch of the superior mesenteric artery, making microcatheter insertion via the antegrade approach challenging. However, a steerable microcatheter was advanced beyond the orifice and the tip was reversed, changing the route to retrograde allowing for easy insertion of the microguidewire. Subsequently, a small microcatheter was advanced beyond the pseudoaneurysm into the dorsal pancreatic artery, and arterial embolization was successfully completed without complications.


Asunto(s)
Aneurisma Falso , Embolización Terapéutica , Humanos , Embolización Terapéutica/métodos , Embolización Terapéutica/instrumentación , Aneurisma Falso/terapia , Arteria Mesentérica Superior , Páncreas , Masculino , Catéteres , Femenino , Anciano , Complicaciones Posoperatorias
6.
Artículo en Inglés | MEDLINE | ID: mdl-38757702

RESUMEN

PURPOSE: This study aimed to assess the outcomes of percutaneous cryoablation (PCA) for renal cell carcinomas (RCCs) contacting critical organs without intervening fat tissue. MATERIAL AND METHODS: Twenty-three patients with 24 RCCs (mean size, 28.8 mm) contacting critical organs on preprocedural images were included. The organ displacement techniques, technical success, efficacy, and adverse events per Clavien-Dindo classification were retrospectively reviewed. RESULTS: The organs contacting the RCCs included the colon (n = 16), pancreas (n = 3), duodenum (n = 3), small intestine (n = 1), and stomach (n = 1). In all procedures, hydrodissection was conducted, and probe traction was additionally utilized in one to displace organs. Two procedures were terminated with an insufficient ice-ball margin (<6 mm) due to recurring proximity of the colon or thermal sink effect by renal hilar vessels, yielding a technical success rate of 91.6% (22/24). No severe adverse events were noted. All patients were alive without any metastases during a median follow-up of 34.4 months. The primary and secondary technical efficacy rates were 91.6% (22/24) and 95.8% (23/24) of tumors, respectively. CONCLUSION: PCA can be a valid option for RCCs contacting critical organs with a good safety profile and sufficient technical efficacy.

7.
Acta Med Okayama ; 77(1): 81-84, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36849150

RESUMEN

Osteoid osteoma (OO) is a benign bone tumor that presents with nocturnal pain. Computed tomography (CT)- guided radiofrequency ablation (RFA) has been widely performed for OO, and major adverse events post-RFA are rare. We report a case of OO in the left navicular bone of a 15-year-old male. He underwent RFA for OO, and the pain improved temporarily. At the 1-month follow-up, the patient complained of left foot pain, and a CT examination revealed a fracture of the ablated navicular bone. Fractures are rare but must be taken into account after bone RFA.


Asunto(s)
Traumatismos del Tobillo , Neoplasias Óseas , Fracturas Óseas , Traumatismos de la Rodilla , Osteoma Osteoide , Ablación por Radiofrecuencia , Masculino , Humanos , Adolescente , Osteoma Osteoide/diagnóstico por imagen , Osteoma Osteoide/cirugía , Dolor , Fracturas Óseas/cirugía , Ablación por Radiofrecuencia/efectos adversos , Neoplasias Óseas/cirugía
8.
Acta Med Okayama ; 77(2): 121-129, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37094949

RESUMEN

Percutaneous cryoablation of renal tumors is widely used because of its high efficacy and safety. This high safety can be attributed, at least in part, to the visibility of the ablated area as an "ice ball". This therapy has fewer complications (incidence, 0-7.2%) and is less invasive than surgery. Minor bleeding is inevitable in most kidney-related procedures, and indeed the most common complication of this therapy is bleeding (hematoma and hematuria). However, patients require treatment such as transfusion or transarterial embolization in only 0-4% of bleeding cases. Various other complications such as ureteral or collecting system injury, bowel injury, nerve injury, skin injury, infection, pneumothorax, and tract seeding also occur, but they are usually minor and asymptomatic. However, operators should know and avoid the various complications associated with this therapy. This study aimed to summarize the complications of percutaneous cryoablation for renal tumors and provide some techniques for achieving safe procedures.


Asunto(s)
Carcinoma de Células Renales , Criocirugía , Neoplasias Renales , Humanos , Criocirugía/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias Renales/cirugía , Hemorragia/etiología , Hematoma/etiología , Resultado del Tratamiento , Carcinoma de Células Renales/cirugía , Estudios Retrospectivos
9.
Acta Med Okayama ; 77(6): 665-669, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38145942

RESUMEN

We report the case details of a 65-year-old Japanese man with an omental abscess that was discovered 43 days after he underwent a laparoscopic proximal gastrectomy for gastric cancer. His chief complaint was mild abdominal pain that had persisted for several days. The abscess was diagnosed as a rare postoperative complication. We hesitated to perform a reoperation given the invasiveness of general anesthesia and surgery, plus the possibility of postoperative adhesions and because the patient's general condition was stable and he had only mild abdominal pain. Percutaneous drainage using a 10.2-F catheter was performed with the patient under conscious sedation and computed tomography-fluoroscopy guidance, with no complications. After the procedure, the size of the abscess cavity was remarkably reduced, and 23 days later the catheter was withdrawn.


Asunto(s)
Absceso , Laparoscopía , Masculino , Humanos , Anciano , Absceso/etiología , Drenaje/efectos adversos , Drenaje/métodos , Gastrectomía/efectos adversos , Dolor Abdominal/complicaciones , Laparoscopía/efectos adversos , Laparoscopía/métodos
10.
Int J Clin Oncol ; 27(10): 1589-1595, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35945389

RESUMEN

BACKGROUND: We prospectively evaluated the safety and efficacy of percutaneous cryoablation combined with transcatheter renal arterial embolization for the treatment of tumors ≥ 3 cm in diameter. METHODS: We included patients aged ≥ 20 years with histologically proven renal cell carcinoma with a tumor diameter ≥ 3 cm who were inoperable or refused surgery. Prior to ablation, transcatheter arterial embolization was performed using a mixture of absolute ethanol and iodized oil. All cryoablation procedures were performed percutaneously under computed tomography fluoroscopy guidance. The primary endpoint was safety, which was evaluated for adverse events using CTCAE version 4.0. The secondary endpoint was survival; overall survival, progression-free survival, and cancer-specific survival were calculated. RESULTS: From October 2013 to March 2016, 19 patients (mean age, 75 ± 13 years; 5 women, 14 men) were prospectively enrolled. The mean tumor diameter was 3.9 ± 0.7 (range 3.1-5.3) cm. Four grade 3 hematologic adverse events occurred, while no symptomatic grade ≥ 3 events occurred. The median follow-up period was 68 (range 52-84) months. During the follow-up period, two patients developed local tumor progression at 3 and 42 months after the initial ablative procedure; no patient showed distant metastasis. Two patients died from causes other than RCC. Overall survival, progression-free survival, and cause-specific survival were 100%, 95%, and 100% at 3 years, and 95%, 84%, and 100% at 5 years, respectively. CONCLUSION: Percutaneous cryoablation combined with prior TAE for the treatment of tumors ≥ 3 cm in diameter was safe and achieved favorable survival.


Asunto(s)
Carcinoma de Células Renales , Criocirugía , Embolización Terapéutica , Neoplasias Renales , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/patología , Carcinoma de Células Renales/cirugía , Criocirugía/métodos , Etanol , Femenino , Humanos , Aceite Yodado , Neoplasias Renales/patología , Neoplasias Renales/cirugía , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
11.
Acta Med Okayama ; 76(1): 57-62, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35236999

RESUMEN

To evaluate the volume and heat-sink effects of microwave ablation (MWA) in the ablation zone of the normal swine lung. MWA at 100 W was performed for 1, 2, and 3 min in 7, 5, and 5 lung zones, respectively. We assessed the histopathology in the ablation zones and other outcome measures: namely, length of the longest long and short axes, sphericity, ellipsoid area, and ellipsoid volume. The mean long- and short-axis diameters were 22.0 and 14.1 mm in the 1-min ablation zone, 27.6 and 20.2 mm in the 2-min ablation zone; and 29.2 and 21.2 mm in the 3-min ablation zone, respectively. All measures, except sphericity, were significantly less with 1-min ablation than with either 2- or 3-min ablation. There were no significant differences between the 2- and 3-min ablation zones, but all measures except sphericity were larger with 3-min ablation. Although there were no blood vessels that resulted in a heat-sink effect within the ablation zones, the presence of bronchi nearby in 5 lung ablation zones resulted in reduced ablation size. In high-power, short-duration MWA, the lung ablation volume was affected by ablation time. Some ablations showed that a heat-sink effect by a neighboring bronchus might occur.


Asunto(s)
Técnicas de Ablación , Pulmón/cirugía , Microondas , Porcinos/cirugía , Animales , Ablación por Catéter , Factores de Tiempo
12.
Int J Clin Oncol ; 26(3): 562-568, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33174078

RESUMEN

BACKGROUND: Percutaneous cryoablation is widely used for the treatment of renal cell carcinoma. We prospectively evaluated the oncologic outcomes and safety of percutaneous cryoablation for the treatment of tumors ≤ 4 cm in diameter. METHODS: We included patients aged ≥ 20 years, who had histologically proven renal cell carcinoma, tumor diameter ≤ 4 cm, a performance status of ≤ 1, acceptable laboratory parameters, were inoperable or refused to undergo surgery, and had signed a written informed consent. The primary endpoint was the cause-specific survival rate. The secondary endpoints were overall and progression-free survival, and adverse event frequency and grade. All procedures were percutaneously performed under computed tomography fluoroscopy guidance. RESULTS: From October 2013 to October 2015, 33 patients (mean age: 68 ± 14 years; sex: six women, 27 men) were enrolled. The mean tumor diameter was 2.1 ± 0.6 (range 1.0-3.4) cm. The median follow-up period was 60.1 (range 18.4-76.6) months. One patient died of non-renal cell carcinoma-related disease 46 months after percutaneous cryoablation. The cause-specific and overall survival rates were 100% and 96.8% at 3 years, and 100% and 96.8% at 5 years, respectively. There was no local tumor progression or distant metastasis. The incidence of severe urological (urinary fistula and perinephric infection) and non-urological adverse events (increased creatine kinase and skin ulceration) was 6% each. CONCLUSION: Percutaneous cryoablation for renal cell carcinoma ≤ 4 cm in diameter achieved good tumor control with a low complication frequency.


Asunto(s)
Carcinoma de Células Renales , Criocirugía , Neoplasias Renales , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Carcinoma de Células Renales/cirugía , Criocirugía/efectos adversos , Femenino , Humanos , Neoplasias Renales/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
13.
Acta Med Okayama ; 75(1): 9-14, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33649608

RESUMEN

To assess the feasibility of needle tract ablation in liver tissue in ex vivo and in vivo animal models using a cryo-probe and electrosurgical device. The experimental device is made by inserting a cryoprobe through an intro-ducer sheath for insulation, with 2-cm of probe tip projecting out. A beagle liver was punctured by the device, and electric current was applied at 30-W with the electrosurgical knife touching the non-insulated device base. The discolored area of cut surface along the device was evaluated in 5 application-time groups (5 , 10 , 15 , 20, or 25 seconds). An ex vivo experiment was performed to determine an ablation algorithm with an appropriate application time by comparison with radiofrequency ablation (RFA) results. Thereafter, an in vivo experiment was performed to verify the algorithm's feasibility. In the ex vivo model, the cut surface demonstrated different amounts of discolored area according to the application time. The total discolored area in the 20-seconds group was similar to that by RFA. In the in vivo model, the liver did not bleed, the total discolored area was similar to that ex vivo, and coagulation necrosis was confirmed by photomicrograph. Needle tract ablation can be per-formed using the experimental device and electrosurgical device.


Asunto(s)
Ablación por Catéter/métodos , Electrocirugia/instrumentación , Hígado/cirugía , Animales , Perros , Femenino , Hemorragia/prevención & control , Hígado/patología , Agujas
14.
Eur Radiol ; 30(2): 927-933, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31444597

RESUMEN

INTRODUCTION: This was a prospective, first-in-human trial to evaluate the feasibility and safety of insertion of biopsy introducer needles with our robot during CT fluoroscopy-guided biopsy in humans. MATERIALS AND METHODS: Eligible patients were adults with a lesion ≥ 10 mm in an extremity or the trunk requiring pathological diagnosis with CT fluoroscopy-guided biopsy. Patients in whom at-risk structures were located within 10 mm of the scheduled needle tract were excluded. Ten patients (4 females and 6 males; mean [range] age, 72 [52-87] years) with lesions (mean [range] maximum diameter, 28 [14-52] mm) in the kidney (n = 4), lung (n = 3), mediastinum (n = 1), adrenal gland (n = 1), and muscle (n = 1) were enrolled. The biopsy procedure involved robotic insertion of a biopsy introducer needle followed by manual acquisition of specimens using a biopsy needle. The patients were followed up for 14 days. Feasibility was defined as the distance of ≤ 10 mm between needle tip after insertion and the nearest lesion edge on the CT fluoroscopic images. The safety of robotic insertion was evaluated on the basis of machine-related troubles and adverse events according to the Clavien-Dindo classification. RESULTS: Robotic insertion of the introducer needle was feasible in all patients, enabling pathological diagnosis. There was no machine-related trouble. A total of 11 adverse events occurred in 8 patients, including 10 grade I events and 1 grade IIIa event. CONCLUSION: Insertion of biopsy introducer needles with our robot was feasible at several locations in the human body. KEY POINTS: • Insertion of biopsy introducer needles with our robot during CT fluoroscopy-guided biopsy was feasible at several locations in the human body.


Asunto(s)
Biopsia Guiada por Imagen/métodos , Radiografía Intervencional/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Adulto , Biopsia con Aguja/métodos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Fluoroscopía/métodos , Humanos , Biopsia Guiada por Imagen/instrumentación , Masculino , Persona de Mediana Edad , Agujas , Estudios Prospectivos , Robótica/métodos , Tomografía Computarizada por Rayos X/métodos
15.
Eur Radiol ; 30(3): 1342-1349, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31773299

RESUMEN

OBJECTIVES: To evaluate the accuracy of robotic CT-guided out-of-plane needle insertion in phantom and animal experiments. METHODS: A robotic system (Zerobot), developed at our institution, was used for needle insertion. In the phantom experiment, 12 robotic needle insertions into a phantom at various angles in the XY and YZ planes were performed, and the same insertions were manually performed freehand, as well as guided by a smartphone application (SmartPuncture). Angle errors were compared between the robotic and smartphone-guided manual insertions using Student's t test. In the animal experiment, 6 robotic out-of-plane needle insertions toward targets of 1.0 mm in diameter placed in the kidneys and hip muscles of swine were performed, each with and without adjustment of needle orientation based on reconstructed CT images during insertion. Distance accuracy was calculated as the distance between the needle tip and the target center. RESULTS: In the phantom experiment, the mean angle errors of the robotic, freehand manual, and smartphone-guided manual insertions were 0.4°, 7.0°, and 3.7° in the XY plane and 0.6°, 6.3°, and 0.6° in the YZ plane, respectively. Robotic insertions in the XY plane were significantly (p < 0.001) more accurate than smartphone-guided insertions. In the animal experiment, the overall mean distance accuracy of robotic insertions with and without adjustment of needle orientation was 2.5 mm and 5.0 mm, respectively. CONCLUSION: Robotic CT-guided out-of-plane needle insertions were more accurate than smartphone-guided manual insertions in the phantom and were also accurate in the in vivo procedure, particularly with adjustment during insertion. KEY POINTS: • Out-of-plane needle insertions performed using our robot were more accurate than smartphone-guided manual insertions in the phantom experiment and were also accurate in the in vivo procedure. • In the phantom experiment, the mean angle errors of the robotic and smartphone-guided manual out-of-plane needle insertions were 0.4° and 3.7° in the XY plane (p < 0.001) and 0.6° and 0.6° in the YZ plane (p = 0.65), respectively. • In the animal experiment, the overall mean distance accuracies of the robotic out-of-plane needle insertions with and without adjustments of needle orientation during insertion were 2.5 mm and 5.0 mm, respectively.


Asunto(s)
Riñón/cirugía , Músculo Esquelético/cirugía , Agujas , Fantasmas de Imagen , Punciones/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Animales , Biopsia Guiada por Imagen/métodos , Riñón/patología , Músculo Esquelético/patología , Robótica/métodos , Teléfono Inteligente , Programas Informáticos , Cirugía Asistida por Computador/métodos , Porcinos , Tomografía Computarizada por Rayos X/métodos
16.
Acta Med Okayama ; 74(3): 209-214, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32577018

RESUMEN

An aspiration-type semi-automatic cutting biopsy needle enables tissue cutting during application of negative pressure, which is expected to contribute to a larger amount of specimen. The aim of the present study was to evaluate this novel needle in a clinical setting. Patients who underwent image-guided percutaneous biopsy for lung or renal masses were enrolled. Cutting biopsy was performed with and without aspiration during each procedure. The specimens were weighed using an electronic scale. The weights were compared between specimens obtained with and without aspiration using a paired t-test. The data from 45 lung and 30 renal biopsy procedures were analyzed. In lung biopsy, the mean±standard deviation weights of specimens obtained with and without aspiration were 2.20±1.05 mg and 2.24±1.08 mg, respectively. In renal biopsy, the mean weights were 6.52±2.18 mg and 6.42±1.62 mg, respectively. The weights were not significantly different between specimens obtained with and without aspiration either in lung (p=0.799) or renal (p=0.789) biopsies. The application of negative pressure with the aspiration-type semi-automatic cutting biopsy needle did not contribute to an increase in the amount of the specimen obtained in lung and renal biopsies.


Asunto(s)
Biopsia con Aguja/métodos , Biopsia Guiada por Imagen/instrumentación , Riñón/patología , Pulmón/patología , Anciano , Biopsia con Aguja/efectos adversos , Estudios de Casos y Controles , Femenino , Humanos , Biopsia Guiada por Imagen/efectos adversos , Masculino , Memoria Episódica , Persona de Mediana Edad , Manejo de Especímenes/métodos , Tomografía Computarizada por Rayos X
17.
Acta Med Okayama ; 74(5): 443-448, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33106702

RESUMEN

We report a 47-year-old Japanese female with 10 previous treatments for multiple bilateral renal cell carcinoma (RCC) associated with von Hippel-Lindau disease. The 14-mm right lower pole renal tumor was in contact with the right ureter. Laparoscopic cryoablation was performed to protect the ureter wrapped with gauze. Computed tomography (CT) monitoring was used to confirm the precise ≥ 6 mm ice-ball margin. There was no local progression at 6-months post-surgery. The serum creatinine has been stable. This is apparently the first report of combined laparoscopic and CT monitoring of an ice-ball formation and its margin during cryoablation for RCC.


Asunto(s)
Carcinoma de Células Renales/cirugía , Criocirugía/métodos , Neoplasias Renales/cirugía , Enfermedad de von Hippel-Lindau/cirugía , Carcinoma de Células Renales/diagnóstico por imagen , Femenino , Humanos , Neoplasias Renales/diagnóstico por imagen , Laparoscopía , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Enfermedad de von Hippel-Lindau/dietoterapia
18.
BMC Surg ; 20(1): 307, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33261613

RESUMEN

BACKGROUND: Hemobilia occurs mainly due to iatrogenic factors such as impairment of the right hepatic or cystic artery, and/or common bile duct in hepatobiliary-pancreatic surgery. However, little or no cases with hemobilia from the intra-pancreatic remnant bile duct after bile duct resection (BDR) has been reported. Here, we report a case of massive hemobilia due to the perforation of psuedoaneurysm of the gastroduodenal artery (GDA) to the intra-pancreatic remnant bile duct after hepatectomy with BDR. CASE PRESENTATION: A 68-year-old male underwent extended right hepatectomy with BDR for gallbladder carcinoma. He presented with upper gastrointestinal bleeding 2 months after the initial surgery. Upper endoscopy identified a blood clot from the ampulla of Vater and simultaneous endoscopic balloon tamponade contributed to temporary hemostasis. Abdominal CT and angiography revealed a perforation of the psuedoaneurysm of the GDA to the intra-pancreatic remnant bile duct resulting in massive hemobilia. Subsequent selective embolization of the pseudoaneurysm with micro-coils could achieve complete hemostasis. He survived without any recurrence of cancer and bleeding. CONCLUSION: Hemobilia could occur in a patient with BDR due to perforation of the pseudoaneurysm derived from the GDA to the intra-pancreatic remnant bile duct. Endoscopic balloon tamponade was useful for a temporal hemostasis and a subsequent radiologic interventional approach.


Asunto(s)
Aneurisma Falso , Conductos Biliares/cirugía , Hemobilia , Anciano , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/cirugía , Hemobilia/etiología , Hemobilia/cirugía , Arteria Hepática/patología , Humanos , Masculino
20.
Cardiovasc Intervent Radiol ; 47(1): 132-138, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38010507

RESUMEN

PURPOSE: To evaluate the detection rate of feeding arteries in renal cell carcinoma with automated feeder-detection software and determine the optimal imaging phase for accurate feeder detection with transarterial time-resolved computed tomography angiography. MATERIALS AND METHODS: The performance of automated feeder-detection software was retrospectively evaluated using transarterial renal time-resolved computed tomography angiography images of 15 renal cell carcinomas (mean size, 22.1 mm); the images were obtained via the renal artery using a hybrid angio-CT system with 320-row computed tomography, across nine phases with 0.5-s intervals over a contrast delay time of 1.0-5.0 s. Automated feeder-detection software was applied to each phase in all tumors (135 image series in total). The feeder-detection rate (i.e., sensitivity) in each phase was evaluated, and the number of false feeders demonstrated by the software was counted for each tumor. RESULTS: A total of 22 feeders were identified. The feeder-detection rate was the highest (95.5% [21/22]) at delay times of 1.5 s and 2.0 s and lower in later phases. At delay times of 1.0 s and 1.5 s, the software demonstrated no or only a few (≤ 3) false feeders in 93.3% (14/15) of the tumors. In later phases, however, many (≥ 4) false feeders were observed in > 50% of tumors. CONCLUSION: The automated feeder-detection software showed a favorable feeder-detection rate and may be useful in transarterial embolization for renal cell carcinoma. The optimal delay time to avoid the demonstration of false feeders and achieve a high detection accuracy was 1.5 s. LEVEL OF EVIDENCE IV: Case Series.


Asunto(s)
Carcinoma Hepatocelular , Carcinoma de Células Renales , Quimioembolización Terapéutica , Neoplasias Renales , Neoplasias Hepáticas , Humanos , Estudios Retrospectivos , Angiografía por Tomografía Computarizada , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/terapia , Quimioembolización Terapéutica/métodos , Tomografía Computarizada por Rayos X , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/terapia , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA