Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Cereb Cortex ; 30(5): 2879-2896, 2020 05 14.
Artículo en Inglés | MEDLINE | ID: mdl-31832642

RESUMEN

Intracortical microstimulation can be used successfully to modulate neuronal activity. Activity-dependent stimulation (ADS), in which action potentials recorded extracellularly from a single neuron are used to trigger stimulation at another cortical location (closed-loop), is an effective treatment for behavioral recovery after brain lesion, but the related neurophysiological changes are still not clear. Here, we investigated the ability of ADS and random stimulation (RS) to alter firing patterns of distant cortical locations. We recorded 591 neuronal units from 23 Long-Evan healthy anesthetized rats. Stimulation was delivered to either forelimb or barrel field somatosensory cortex, using either RS or ADS triggered from spikes recorded in the rostral forelimb area (RFA). Both RS and ADS stimulation protocols rapidly altered spike firing within RFA compared with no stimulation. We observed increase in firing rates and change of spike patterns. ADS was more effective than RS in increasing evoked spikes during the stimulation periods, by producing a reliable, progressive increase in stimulus-related activity over time and an increased coupling of the trigger channel with the network. These results are critical for understanding the efficacy of closed-loop electrical microstimulation protocols in altering activity patterns in interconnected brain networks, thus modulating cortical state and functional connectivity.


Asunto(s)
Potenciales de Acción/fisiología , Corteza Motora/fisiología , Red Nerviosa/fisiología , Neuronas/fisiología , Corteza Somatosensorial/fisiología , Animales , Estimulación Eléctrica/métodos , Miembro Anterior/inervación , Miembro Anterior/fisiología , Masculino , Microelectrodos , Ratas , Ratas Long-Evans
2.
J Neurosci ; 38(41): 8759-8771, 2018 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-30150363

RESUMEN

Neuromuscular control of voluntary movement may be simplified using muscle synergies similar to those found using non-negative matrix factorization. We recently identified synergies in electromyography (EMG) recordings associated with both voluntary movement and movement evoked by high-frequency long-duration intracortical microstimulation applied to the forelimb representation of the primary motor cortex (M1). The goal of this study was to use stimulus-triggered averaging (StTA) of EMG activity to investigate the synergy profiles and weighting coefficients associated with poststimulus facilitation, as synergies may be hard-wired into elemental cortical output modules and revealed by StTA. We applied StTA at low (LOW, ∼15 µA) and high intensities (HIGH, ∼110 µA) to 247 cortical locations of the M1 forelimb region in two male rhesus macaques while recording the EMG of 24 forelimb muscles. Our results show that 10-11 synergies accounted for 90% of the variation in poststimulus EMG facilitation peaks from the LOW-intensity StTA dataset while only 4-5 synergies were needed for the HIGH-intensity dataset. Synergies were similar across monkeys and current intensities. Most synergy profiles strongly activated only one or two muscles; all joints were represented and most, but not all, joint directions of motion were represented. Cortical maps of the synergy weighting coefficients suggest only a weak organization. StTA of M1 resulted in highly diverse muscle activations, suggestive of the limiting condition of requiring a synergy for each muscle to account for the patterns observed.SIGNIFICANCE STATEMENT Coordination of muscle activity and the neural origin of potential muscle synergies remains a fundamental question of neuroscience. We previously demonstrated that high-frequency long-duration intracortical microstimulation-evoked synergies were unrelated to voluntary movement synergies and were not clearly organized in the cortex. Here we present stimulus-triggered averaging facilitation-related muscle synergies, suggesting that when fundamental cortical output modules are activated, synergies approach the limit of single-muscle control. Thus, we conclude that if the CNS controls movement via linear synergies, those synergies are unlikely to be called from M1. This information is critical for understanding neural control of movement and the development of brain-machine interfaces.


Asunto(s)
Corteza Motora/fisiología , Contracción Muscular , Músculo Esquelético/fisiología , Extremidad Superior/fisiología , Animales , Estimulación Eléctrica , Electromiografía , Macaca mulatta , Masculino , Extremidad Superior/inervación
3.
J Neurophysiol ; 118(1): 455-470, 2017 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-28446586

RESUMEN

Simplifying neuromuscular control for movement has previously been explored by extracting muscle synergies from voluntary movement electromyography (EMG) patterns. The purpose of this study was to investigate muscle synergies represented in EMG recordings associated with direct electrical stimulation of single sites in primary motor cortex (M1). We applied single-electrode high-frequency, long-duration intracortical microstimulation (HFLD-ICMS) to the forelimb region of M1 in two rhesus macaques using parameters previously found to produce forelimb movements to stable spatial end points (90-150 Hz, 90-150 µA, 1,000-ms stimulus train lengths). To develop a comprehensive representation of cortical output, stimulation was applied systematically across the full extent of M1. We recorded EMG activity from 24 forelimb muscles together with movement kinematics. Nonnegative matrix factorization (NMF) was applied to the mean stimulus-evoked EMG, and the weighting coefficients associated with each synergy were mapped to the cortical location of the stimulating electrode. Synergies were found for three data sets including 1) all stimulated sites in the cortex, 2) a subset of sites that produced stable movement end points, and 3) EMG activity associated with voluntary reaching. Two or three synergies accounted for 90% of the overall variation in voluntary movement EMG whereas four or five synergies were needed for HFLD-ICMS-evoked EMG data sets. Maps of the weighting coefficients from the full HFLD-ICMS data set show limited regional areas of higher activation for particular synergies. Our results demonstrate fundamental NMF-based muscle synergies in the collective M1 output, but whether and how the central nervous system might coordinate movements using these synergies remains unclear.NEW & NOTEWORTHY While muscle synergies have been investigated in various muscle activity sets, it is unclear whether and how synergies may be organized in the cortex. We have investigated muscle synergies resulting from high-frequency, long-duration intracortical microstimulation (HFLD-ICMS) applied throughout M1. We compared HFLD-ICMS synergies to synergies from voluntary movement. While synergies can be identified from M1 stimulation, they are not clearly related to voluntary movement synergies and do not show an orderly topographic organization across M1.


Asunto(s)
Mapeo Encefálico/métodos , Estimulación Eléctrica , Miembro Anterior/fisiología , Corteza Motora/fisiología , Animales , Fenómenos Biomecánicos , Mapeo Encefálico/instrumentación , Estimulación Eléctrica/instrumentación , Estimulación Eléctrica/métodos , Electromiografía , Macaca mulatta , Masculino , Microelectrodos , Actividad Motora/fisiología
4.
Cereb Cortex ; 26(8): 3335-44, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26209849

RESUMEN

Numerous studies have reported large disparities between short cortico-muscle conduction latencies and long recorded delays between cortical firing and evoked muscle activity. Using methods such as spike- and stimulus-triggered averaging of electromyographic (EMG) activity, previous studies have shown that the time delay between corticomotoneuronal (CM) cell firing and onset of facilitation of forelimb muscle activity ranges from 6.7 to 9.8 ms, depending on the muscle group tested. In contrast, numerous studies have reported delays of 60-122 ms between cortical cell firing onset and either EMG or movement onset during motor tasks. To further investigate this disparity, we simulated rapid active movement by applying frequency-modulated stimulus trains to M1 cortical sites in a rhesus macaque performing a movement task. This yielded corresponding EMG modulations, the latency of which could be measured relative to the stimulus modulations. The overall mean delay from stimulus frequency modulation to EMG modulation was 11.5 ± 5.6 ms, matching closely the conduction time through the cortico-muscle pathway (12.6 ± 2.0 ms) derived from poststimulus facilitation peaks computed at the same sites. We conclude that, during active movement, the delay between modulated M1 cortical output and its impact on muscle activity approaches the physical cortico-muscle conduction time.


Asunto(s)
Actividad Motora/fisiología , Corteza Motora/fisiología , Músculo Esquelético/fisiología , Neuronas/fisiología , Potenciales de Acción , Animales , Estimulación Eléctrica , Electrodos Implantados , Electromiografía , Miembro Anterior/fisiología , Macaca mulatta , Masculino , Microelectrodos , Conducción Nerviosa , Factores de Tiempo
5.
Cereb Cortex ; 26(7): 3036-51, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26088970

RESUMEN

While a large body of evidence supports the view that ipsilateral motor cortex may make an important contribution to normal movements and to recovery of function following cortical injury (Chollet et al. 1991; Fisher 1992; Caramia et al. 2000; Feydy et al. 2002), relatively little is known about the properties of output from motor cortex to ipsilateral muscles. Our aim in this study was to characterize the organization of output effects on hindlimb muscles from ipsilateral motor cortex using stimulus-triggered averaging of EMG activity. Stimulus-triggered averages of EMG activity were computed from microstimuli applied at 60-120 µA to sites in both contralateral and ipsilateral M1 of macaque monkeys during the performance of a hindlimb push-pull task. Although the poststimulus effects (PStEs) from ipsilateral M1 were fewer in number and substantially weaker, clear and consistent effects were obtained at an intensity of 120 µA. The mean onset latency of ipsilateral poststimulus facilitation was longer than contralateral effects by an average of 0.7 ms. However, the shortest latency effects in ipsilateral muscles were as short as the shortest latency effects in the corresponding contralateral muscles suggesting a minimal synaptic linkage that is equally direct in both cases.


Asunto(s)
Electromiografía , Miembro Posterior/fisiología , Actividad Motora/fisiología , Corteza Motora/fisiología , Músculo Esquelético/fisiología , Animales , Estimulación Eléctrica , Electrodos Implantados , Electromiografía/métodos , Lateralidad Funcional , Macaca mulatta , Masculino , Microelectrodos , Factores de Tiempo
6.
J Neurosci ; 34(47): 15722-34, 2014 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-25411500

RESUMEN

High-frequency, long-duration intracortical microstimulation (HFLD-ICMS) is increasingly being used to deduce how the brain encodes coordinated muscle activity and movement. However, the full movement repertoire that can be elicited from the forelimb representation of primary motor cortex (M1) using this method has not been systematically determined. Our goal was to acquire a comprehensive M1 forelimb representational map of movement endpoints elicited with HFLD-ICMS, using stimulus parameters optimal for evoking stable forelimb spatial endpoints. The data reveal a 3D forelimb movement endpoint workspace that is represented in a patchwork fashion on the 2D M1 cortical surface. Although cortical maps of movement endpoints appear quite disorderly with respect to movement space, we show that the endpoint locations in the workspace evoked with HFLD-ICMS of two adjacent cortical points are closer together than would be expected if the organization were random. Although there were few obvious consistencies in the endpoint maps across the two monkeys tested, one notable exception was endpoints bringing the hand to the mouth, which was located at the boundary between the hand and face representation. Endpoints at the extremes of the monkey's workspace and locations above the head were largely absent. Our movement endpoints are best explained as resulting from coactivation of agonist and antagonist muscles driving the joints toward equilibrium positions determined by the length-tension relationships of the muscles.


Asunto(s)
Corteza Motora/fisiología , Movimiento/fisiología , Equilibrio Postural/fisiología , Animales , Brazo/inervación , Brazo/fisiología , Mapeo Encefálico , Estimulación Eléctrica , Electrodos Implantados , Electromiografía , Macaca mulatta , Conejos
7.
Int J Neurosci ; 124(3): 166-74, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24000873

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI) after deep brain stimulation (DBS) carries the risk of heating at the lead-contacts within the brain. OBJECTIVE/HYPOTHESIS: To compare the effect of single- and dual-channel DBS implantable pulse generator (IPG) configurations on brain lead-contact heating during 3T MRI. METHODS: A phantom with bilateral brain leads and extensions connected to two single-channel IPGs or a dual-channel right or left IPG was utilized. Using a transmit/receive head coil, seven scan sequences were conducted yielding a range of head-specific absorption rates (SAR-H). Temperature changes (ΔT) at the bilateral 0 and 3 lead-contacts were recorded, and normalized temperatures (ΔT/SAR-H) and slopes defining the ΔT/SAR-H over the SAR-H range were compared. RESULTS: Greater heating was strongly correlated with higher SAR-H in all configurations. For each scan sequence, the ΔT/SAR-H of single-channel left lead-contacts was significantly greater than the ΔT/SAR-H of either dual-channel configuration. The slope defining the relationship between ΔT and SAR-H for the single-channel left lead (1.68°C/SAR-H) was significantly greater (p < 0.0001) than the ΔT/SAR-H slope for the single-channel right lead (0.97°C/SAR-H), both of which were significantly greater (p < 0.0001) than the ΔT/SAR-H slopes of left or right leads (range 0.68 to 0.70°C/SAR-H) in the dual-channel configurations. There were no significant differences in ΔT/SAR-H slope values between the dual-channel configurations. CONCLUSION: DBS hardware configuration using bilateral single-channel versus unilateral dual-channel IPGs significantly affects DBS lead-contact heating during 3T MRI brain scanning.


Asunto(s)
Encéfalo/fisiología , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/métodos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Fantasmas de Imagen , Calefacción , Humanos , Plomo
8.
J Neurophysiol ; 110(5): 1180-9, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23741044

RESUMEN

High-frequency, long-duration intracortical microstimulation (HFLD-ICMS) applied to motor cortex is recognized as a useful and informative method for corticomotor mapping by evoking natural-appearing movements of the limb to consistent stable end-point positions. An important feature of these movements is that stimulation of a specific site in motor cortex evokes movement to the same spatial end point regardless of the starting position of the limb. The goal of this study was to delineate effective stimulus parameters for evoking forelimb movements to stable spatial end points from HFLD-ICMS applied to primary motor cortex (M1) in awake monkeys. We investigated stimulation of M1 as combinations of frequency (30-400 Hz), amplitude (30-200 µA), and duration (0.5-2 s) while concurrently recording electromyographic (EMG) activity from 24 forelimb muscles and movement kinematics with a motion capture system. Our results suggest a range of parameters (80-140 Hz, 80-140 µA, and 1,000-ms train duration) that are effective and safe for evoking forelimb translocation with subsequent stabilization at a spatial end point. The mean time for stimulation to elicit successful movement of the forelimb to a stable spatial end point was 475.8 ± 170.9 ms. Median successful frequency and amplitude were 110 Hz and 110 µA, respectively. Attenuated parameters resulted in inconsistent, truncated, or undetectable movements, while intensified parameters yielded no change to movement end points and increased potential for large-scale physiological spread and adverse focal motor effects. Establishing cortical stimulation parameters yielding consistent forelimb movements to stable spatial end points forms the basis for a systematic and comprehensive mapping of M1 in terms of evoked movements and associated muscle synergies. Additionally, the results increase our understanding of how the central nervous system may encode movement.


Asunto(s)
Miembro Anterior/fisiología , Corteza Motora/fisiología , Movimiento , Animales , Estimulación Eléctrica/métodos , Macaca mulatta , Masculino
9.
Am J Phys Med Rehabil ; 102(11): e149-e151, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37126791

RESUMEN

ABSTRACT: Spinal cord stimulation is an increasingly used treatment for a number of chronic pain states. Dorsal column stimulation is historically and currently the anatomical target of choice for most chronic pain conditions, including postlaminectomy syndrome and radicular pain. However, early studies suggested that stimulation of an alternative target, the ventral columns that carry pain fibers in the anterior and lateral spinothalamic tracts, may offer comparable or superior pain relief. A patient undergoing standard-of-care spinal cord stimulation trial had an additional lead placed on the right ventrolateral aspect of the spinal cord. After the usual 7-day trial of dorsal column stimulation, the dorsal leads were removed and ventrolateral column stimulation was applied through the retained ventral lead for a period of 3 days. The Brief Pain Index Short Form and Numeric Rating Scale were recorded for both dorsal and ventral stimulation. Ventrolateral spinal cord stimulation provided comparable outcomes compared with dorsal column stimulation using nonparesthesia-based stimulation. The results suggest further investigation into spinal cord stimulation anatomical placement and mechanism of action is warranted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA