Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Arch Orthop Trauma Surg ; 129(5): 703-9, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-18421465

RESUMEN

INTRODUCTION: During the drilling of the bone, the temperature could increase above 47 degrees C and cause irreversible osteonecrosis. The spatial distribution of increase in bone temperature could only be presumed using several thermocouples around the drilling site. The aim of this study was to use infrared thermographic camera for determination of spatial distribution of increase in bone temperature during drilling. MATERIALS AND METHODS: One combination of drill parameters was used (drill diameter 4.5 mm; drill speed 1,820 rpm; feed-rate 84 mm/min; drill point angle 100 degrees) without external irrigation on room temperature of 26 degrees C. The increase in bone temperature during drilling was analyzed with infrared thermographic camera in two perpendicular planes. Thermographic pictures were taken before drilling, during drilling with measurement of maximal temperature values and after extraction of the drill from the bone. RESULTS: The thermographic picture shows that the increase in bone temperature has irregular shape with maximal increase along cortical bone, which is the most compact component of the bone. The width of this area with the temperature above critical level is three times broader than the width of cortical bone. From the front, the distribution of increase in bone temperature follows the form of the cortical bone (segment of a ring), which is the most compact part and causes the highest resistance to drilling and subsequent friction. CONCLUSIONS: Thermography showed that increase in bone temperature spreads through cortical bone, which is the most compact and dense part, and generates highest frictional heat during drilling. The medullar cavity, because of its gelatinous structure, contributes only to thermal dissipation.


Asunto(s)
Temperatura Corporal/fisiología , Huesos/fisiología , Procedimientos Ortopédicos , Termografía , Animales , Perros , Rayos Infrarrojos , Masculino , Porcinos , Termografía/métodos
2.
Arch Orthop Trauma Surg ; 128(1): 71-7, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17762937

RESUMEN

INTRODUCTION: During the drilling of the bone, the temperature could increase above 47 degrees C and cause irreversible osteonecrosis. The result is weakened contact of implants with bone and possible loss of rigid fixation. The aim of this study was to find an optimal condition where the increase in bone temperature during bone drilling process would be minimal. MATERIALS AND METHODS: Influence of different drill parameters was evaluated on the increase of bone temperature. Drill diameters were 2.5, 3.2 and 4.5 mm; drill speed 188, 462, 1,140 and 1,820 rpm; feed-rate 24, 56, 84 and 196 mm/min; drill point angle 80 degrees , 100 degrees and 120 degrees and external irrigation with water of 26 degrees C. RESULTS: Combinations of drill speed and drill diameter with the use of external irrigation produced temperatures far below critical. Without external irrigation, temperature values for the same combination of parameters ranged 31.4-55.5 degrees C. Temperatures above critical were recorded using 4.5 mm drill with higher drill speeds (1,140 and 1,820 rpm). There was no statistical significance of different drill point angles on the increase or decrease of bone temperature. The higher the feed-rate the lower the increase of bone temperature. CONCLUSIONS: The external irrigation is the most important cooling factor. With all combinations of parameters used, external irrigation maintained the bone temperature below 47 degrees C. The increase in drill diameter and drill speed caused increase in bone temperature. The changes in drill point angle did not show significant influence in the increase of the bone temperature. With the increase in feed-rate, increase in bone temperature is lower.


Asunto(s)
Temperatura Corporal , Huesos/fisiología , Procedimientos Ortopédicos , Irrigación Terapéutica , Animales , Huesos/cirugía , Diseño de Equipo , Fémur/fisiología , Fémur/cirugía , Procedimientos Ortopédicos/efectos adversos , Procedimientos Ortopédicos/instrumentación , Osteonecrosis/prevención & control , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA