Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(2): 290-300, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38098308

RESUMEN

INTRODUCTION: Mitral valve prolapse (MVP) is a common clinical condition in the general population. A subgroup of patients with MVP may experience ventricular arrhythmias and sudden cardiac death ("arrhythmic mitral valve prolapse" [AMVP]) but how to stratify arrhythmic risk is still unclear. Our meta-analysis aims to identify predictive factors for arrhythmic risk in patients with MVP. METHODS: We systematically searched Medline, Cochrane, Journals@Ovid, Scopus electronic databases for studies published up to December 28, 2022 and comparing AMVP and nonarrhythmic mitral valve prolapse (NAMVP) for what concerns history, electrocardiographic, echocardiographic and cardiac magnetic resonance features. The effect size was estimated using a random-effect model as odds ratio (OR) and mean difference (MD). RESULTS: A total of 10 studies enrolling 1715 patients were included. Late gadolinium enhancement (LGE) (OR: 16.67; p = .005), T-wave inversion (TWI) (OR: 2.63; p < .0001), bileaflet MVP (OR: 1.92; p < .0001) and mitral anulus disjunction (MAD) (OR: 2.60; p < .0001) were more represented among patients with AMVP than in NAMVP. Patients with AMVP were shown to have longer anterior mitral leaflet (AML) (MD: 2.63 mm; p < .0001), posterior mitral leaflet (MD: 2.96 mm; p < .0001), thicker AML (MD: 0.49 mm; p < .0001), longer MAD length (MD: 1.24 mm; p < .0001) and higher amount of LGE (MD: 1.41%; p < .0001) than NAMVP. AMVP showed increased mechanical dispersion (MD: 8.04 ms; 95% confidence interval: 5.13-10.96; p < .0001) compared with NAMVP. CONCLUSIONS: Our meta-analysis proved that LGE, TWI, bileaflet MVP, and MAD are predictive factors for arrhythmic risk in MVP patients.


Asunto(s)
Prolapso de la Válvula Mitral , Prolapso de la Válvula Mitral/fisiopatología , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/diagnóstico , Humanos , Medición de Riesgo , Factores de Riesgo , Femenino , Masculino , Persona de Mediana Edad , Anciano , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Pronóstico , Adulto , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Frecuencia Cardíaca , Potenciales de Acción
2.
Artículo en Inglés | MEDLINE | ID: mdl-39135364

RESUMEN

INTRODUCTION: Thermal atrial fibrillation (AF) ablation exerts an additive treatment effect on the cardiac autonomic nervous system (CANS). This effect is mainly reported during ablation of the right superior pulmonary vein (RSPV), modulating the right anterior ganglionated plexus (RAGP), which contains parasympathetic innervation to the sinoatrial node in the epicardial fat pad between RSPV and superior vena cava (SVC). However, a variable response to neuromodulation after ablation is observed, with little to no effect in some patients. Our objective was to assess clinical and anatomic predictors of thermal ablation-induced CANS changes, as assessed via variations in heart rate (HR) postablation. METHODS: Consecutive paroxysmal AF patients undergoing first-time PV isolation by the cryoballoon (CB) or radiofrequency balloon (RFB) within a 12-month time frame and with preprocedural cardiac computed tomography (CT), were evaluated. Preablation and 24-h postablation electrocardiograms in sinus rhythm were collected and analyzed to assess HR. Anatomic evaluation by CT included the measurement of the shortest distance between the SVC and RSPV ostium (RSPV-SVC distance). RESULTS: A total of 97 patients (CB, n = 50 vs. RFB, n = 47) were included, with similar baseline characteristics between both groups. A significant HR increase postablation (ΔHR ≥ 15 bpm) occurred in a total of 37 patients (38.1%), without difference in number of patients between both thermal ablation technologies (CB, 19 [51%]), RFB, 18 [49%]). Independent predictors for increased HR were RSPV-SVC distance (odds ratio [OR]: 0.49, CI: 0.34-0.71, p value < .001), and age (OR: 0.94, CI: 0.89-0.98, p value = .003). CONCLUSIONS: Thermal balloon-based PV isolation influences the CANS through its effect on the RAGP, especially in younger patients and patients with shorter RSPV-SVC distance.

3.
Catheter Cardiovasc Interv ; 104(2): 220-226, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38959377

RESUMEN

BACKGROUND: The treatment of resistant coronary lesions (RCL) is a great challenge for interventional cardiologists. The excimer laser coronary atherectomy (ELCA) is a plaque modification tool based on a main mechanism of photomechanical effect leading to mechanical disruption of the plaque. Contrast dye injection during laser delivery has demonstrated to enhance its power. AIM: To evaluate the effectiveness and safety of the contrast-enhanced ELCA by a stepwise approach in the treatment of RCLs. METHODS: We retrospectively examined consecutive patients undergoing contrast-enhanced ELCA-assisted PCI between 2018 and 2021 at two Italian sites. RCLs were defined as novo or in-stent undilatable/uncrossable with conventional balloons (SC/NC balloon). The primary endpoint was ELCA technical success defined as the laser catheter crossing the entire length of the target lesion established by angiographic evidence of the catheter tip in the artery distal to the stenosis. RESULTS: We enrolled 114 patients who underwent contrast-enhanced ELCA-assisted PCI: 58% of the patients had acute coronary syndrome while the left anterior descending artery was the target vessel in 42.1% of cases. The target lesion was most commonly in-stent (56.2%). The 0.9 mm ELCA catheter tip was employed in 89.5% of cases. The most used frequency/fluency profile was 70/70 (39.5%). The use of contrast-enhanced ELCA was associated with high technical, procedural, and clinical success rates (97.4%, 93.7%, and 90.1%, respectively). CONCLUSIONS: The contrast-enhanced ELCA seems to be a safe and effective treatment option for the management of both de novo and in-stent-resistant coronary lesions.


Asunto(s)
Aterectomía Coronaria , Medios de Contraste , Enfermedad de la Arteria Coronaria , Láseres de Excímeros , Humanos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Láseres de Excímeros/uso terapéutico , Aterectomía Coronaria/efectos adversos , Resultado del Tratamiento , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Medios de Contraste/administración & dosificación , Italia , Angiografía Coronaria , Valor Predictivo de las Pruebas , Factores de Tiempo , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/efectos adversos , Stents , Factores de Riesgo
4.
J Cardiovasc Electrophysiol ; 34(11): 2393-2397, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37792572

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Sistema Nervioso Autónomo/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Nervio Vago/cirugía , Frecuencia Cardíaca , Ablación por Catéter/efectos adversos , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 34(8): 1781-1784, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493490

RESUMEN

INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.


Asunto(s)
Miocarditis , Sarcoidosis , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas/etiología , Arritmias Cardíacas/complicaciones , Medios de Contraste , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/epidemiología , Gadolinio , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética/efectos adversos , Miocarditis/complicaciones , Pronóstico , Medición de Riesgo , Factores de Riesgo , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda
6.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38064697

RESUMEN

AIMS: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Enfermedad de la Arteria Coronaria , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/cirugía , Resultado del Tratamiento , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia
7.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38155611

RESUMEN

AIMS: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. METHODS AND RESULTS: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS.After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. CONCLUSION: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.


Asunto(s)
Ablación por Catéter , Taquicardia Sinusal , Humanos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/cirugía , Taquicardia Sinusal/tratamiento farmacológico , Nodo Sinoatrial , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Frecuencia Cardíaca
8.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37889200

RESUMEN

AIMS: Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist and share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value of CKD in patients undergoing percutaneous left atrial appendage occlusion (LAAO). METHODS AND RESULTS: A total of 2124 consecutive AF patients undergoing LAAO were categorized into CKD stage 1+2 (n = 1089), CKD stage 3 (n = 796), CKD stage 4 (n = 170), and CKD stage 5 (n = 69) based on the estimated glomerular filtration rate at baseline. The primary endpoint included cardiovascular (CV) mortality, TE, and major bleeding. The expected annual TE and major bleeding risks were estimated based on the CHA2DS2-VASc and HAS-BLED scores. A non-significant higher incidence of major peri-procedural adverse events (1.7 vs. 2.3 vs. 4.1 vs. 4.3) was observed with worsening CKD (P = 0.14). The mean follow-up period was 13 ± 7 months (2226 patient-years). In comparison to CKD stage 1+2 as a reference, the incidence of the primary endpoint was significantly higher in CKD stage 3 (log-rank P-value = 0.04), CKD stage 4 (log-rank P-value = 0.01), and CKD stage 5 (log-rank P-value = 0.001). Left atrial appendage occlusion led to a TE risk reduction (RR) of 72, 66, 62, and 41% in each group. The relative RR of major bleeding was 58, 44, 51, and 52%, respectively. CONCLUSION: Patients with moderate-to-severe CKD had a higher incidence of the primary composite endpoint. The relative RR in the incidence of TE and major bleeding was consistent across CKD groups.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Insuficiencia Renal Crónica , Accidente Cerebrovascular , Humanos , Apéndice Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Pronóstico , Resultado del Tratamiento , Estudios Retrospectivos , Hemorragia/inducido químicamente , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/epidemiología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Anticoagulantes/efectos adversos
9.
Europace ; 26(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38225176

RESUMEN

AIMS: Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. METHODS AND RESULTS: Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson's: 0.94; P < 0.001; bias: -0.06 (-2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). CONCLUSION: Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Estudios Transversales , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco , Ecocardiografía Transesofágica/métodos , Ecocardiografía/métodos
10.
Pacing Clin Electrophysiol ; 46(11): 1430-1439, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37812165

RESUMEN

BACKGROUND: High-power-short-duration (HPSD) radiofrequency (RF) ablation is a viable alternative to low-power-long-duration (LPLD) RF for pulmonary vein isolation (PVI). Nevertheless, trials showed conflicting results regarding atrial fibrillation (AF) recurrences and few data concerning complications. Therefore, we conducted a meta-analysis of randomized trials comparing HPSD versus LPLD. METHODS: We systematically searched the electronic databases for studies published from inception to March 31, 2023 focusing on HPSD versus LPLD. The study endpoints were AF recurrence, procedural times and overall complications. RESULTS: Five studies enrolling 424 patients met the inclusion criteria (mean age 61.1 years; 54.3% paroxysmal AF; mean LVEF 58.2%). Compared to LPLD, HPSD showed a significantly lower AF recurrence rate [16.3% vs. 30,1%; RR: 0.54 (95% CI: 0.38-0.79); p = 0.001] at a mean 10.9 months follow-up. Moreover, HPSD led to a significant reduction in total procedural time [MD: -26.25 min (95%CI: -42.89 to -9.61); p = 0.002], PVI time [MD: -26.44 min (95%CI: -38.32 to -14.55); p < 0.0001], RF application time [MD: -8.69 min (95%CI: -11.37 to -6.01); p < 0.00001] and RF lesion number [MD: -7.60 (95%CI: -10.15 to -5.05); p < 0.00001]. No difference was found in either right [80.4% vs. 78.2%; RR: 1.04 (95% CI: 0.81-1.32); p = 0.77] or left [92.3% vs. 90.2%; RR: 1.02 (95% CI: 0.94-1.11); p = 0.58] first-pass isolation and overall complications [6% vs. 3.7%; RR: 1.45 (95%CI: 0.53-3.99); p = 0.47] between groups. CONCLUSION: In our metanalysis of randomized trials, HPSD ablation appeared to be associated to a significantly improved freedom from AF and shorter procedures, without increasing the risk of complications.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Persona de Mediana Edad , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Venas Pulmonares/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
11.
Pacing Clin Electrophysiol ; 46(5): 432-439, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37036831

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy (CRT) reduces heart failure (HF) hospitalization and all-cause mortality in HF patients with left bundle branch block (LBBB). Biventricular pacing (BVP) is the gold standard for achieving CRT, but about 30%-40% of patients do not respond to BVP-CRT. Recent studies showed that left bundle branch pacing (LBBP) provided remarkable results in CRT. Therefore, we conducted a meta-analysis aiming to compare LBBP-CRT versus BVP-CRT in HF patients. METHODS: We systematically searched the electronic databases for studies published from inception to December 29, 2022 and focusing on LBBP-CRT versus BVP-CRT in HF patients. The primary endpoint was HF hospitalization. The effect size was estimated using a random-effect model as Risk Ratio (RR) and mean difference (MD). RESULTS: Ten studies enrolling 1063 patients met the inclusion criteria. Compared to BVP-CRT, LBBP-CRT led to significant reduction in HF hospitalization [7.9% vs.14.5%; RR: 0.60 (95%CI: 0.39-0.93); p = .02], QRSd [MD: 30.26 ms (95%CI: 26.68-33.84); p < .00001] and pacing threshold [MD: -0.60 (95%CI: -0.71 to -0.48); p < .00001] at follow up. Furthermore, LBBP-CRT improved LVEF [MD: 5.78% (95%CI: 4.78-6.77); p < .00001], the rate of responder [88.5% vs.72.5%; RR: 1.19 (95%CI: 1.07-1.32); p = .002] and super-responder [60.8% vs. 36.5%; RR: 1.56 (95%CI: 1.27-1.91); p < .0001] patients and the NYHA class [MD: -0.42 (95%CI: -0.71 to -0.14); p < .00001] compared to BVP-CRT. CONCLUSION: In HF patients, LBBP-CRT was superior to BVP-CRT in reducing HF hospitalization. Further significant benefits occurred within the LBBP-CRT group in terms of QRSd, LVEF, pacing thresholds, NYHA class and the rate of responder and super-responder patients.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Tabique Interventricular , Humanos , Terapia de Resincronización Cardíaca/métodos , Resultado del Tratamiento , Sistema de Conducción Cardíaco , Bloqueo de Rama , Fascículo Atrioventricular , Electrocardiografía/métodos
12.
Pacing Clin Electrophysiol ; 46(8): 942-947, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37378419

RESUMEN

INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2  = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2  = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.


Asunto(s)
Vena Axilar , Incisión Venosa , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Vena Axilar/cirugía , Incisión Venosa/métodos , Vena Subclavia , Punciones/métodos , Corazón
13.
Echocardiography ; 40(3): 217-226, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36748264

RESUMEN

BACKGROUND: Early diagnosis of Coronary Artery Disease (CAD) plays a key role to prevent adverse cardiac events such as myocardial infarction and Left Ventricular (LV) dysfunction. Myocardial Work (MW) indices derived from echocardiographic speckle tracking data in combination with non-invasive blood pressure recordings seems promising to predict CAD even in the absence of impairments of standard echocardiographic parameters. Our aim was to compare the diagnostic accuracy of MW indices to predict CAD and to assess intra- and inter-observer variability of MW through a meta-analysis. METHODS: Electronic databases were searched for observational studies evaluating the MW indices diagnostic accuracy for predicting CAD and intra- and inter-observer variability of MW indices. Pooled sensitivity, specificity, and Summary Receiver Operating Characteristic (SROC) curves were assessed. RESULTS: Five studies enrolling 501 patients met inclusion criteria. Global Constructive Work (GCW) had the best pooled sensitivity (89%) followed by GLS (84%), Global Work Index (GWI) (82%), Global Work Efficiency (GWE) (80%), and Global Wasted Work (GWW) (75%). GWE had the best pooled specificity (78%) followed by GWI (75%), GCW (70%), GLS (68%), and GWW (61%). GCW had the best accuracy according to SROC curves, with an area under the curve of 0.86 compared to 0.84 for GWI, 0.83 for GWE, 0.79 for GLS, and 0.74 for GWW. All MW indices had an excellent intra- and inter-observer variability. CONCLUSIONS: GCW is the best MW index proving best diagnostic accuracy in the prediction of CAD with an excellent reproducibility.


Asunto(s)
Enfermedad de la Arteria Coronaria , Disfunción Ventricular Izquierda , Humanos , Reproducibilidad de los Resultados , Ecocardiografía , Miocardio , Función Ventricular Izquierda , Volumen Sistólico
14.
Curr Cardiol Rep ; 25(7): 641-648, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37269474

RESUMEN

PURPOSE OF REVIEW: Myocarditis is an inflammation of the myocardium secondary to a variety of agents such as infectious pathogens, toxins, drugs, and autoimmune disorders. In our review, we provide an overview of miRNA biogenesis and their role in the etiology and pathogenesis of myocarditis, evaluating future directions for myocarditis management. RECENT FINDINGS: Advances in genetic manipulation techniques allowed to demonstrate the important role of RNA fragments, especially microRNAs (miRNAs), in cardiovascular pathogenesis. miRNAs are small non-coding RNA molecules that regulate the post-transcriptional gene expression. Advances in molecular techniques allowed to identify miRNA's role in pathogenesis of myocarditis. miRNAs are related to viral infection, inflammation, fibrosis, and apoptosis of cardiomyocytes, making them not only promising diagnostic markers but also prognostics and therapeutic targets in myocarditis. Of course, further real-world studies will be needed to assess the diagnostic accuracy and applicability of miRNA in the myocarditis diagnosis.


Asunto(s)
MicroARNs , Miocarditis , Humanos , MicroARNs/genética , MicroARNs/metabolismo , Miocarditis/diagnóstico , Miocarditis/genética , Miocardio/patología , Miocitos Cardíacos/patología , Inflamación
15.
Sensors (Basel) ; 23(6)2023 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-36991870

RESUMEN

A diagnosis of Brugada syndrome (BrS) is based on the presence of a type 1 electrocardiogram (ECG) pattern, either spontaneously or after a Sodium Channel Blocker Provocation Test (SCBPT). Several ECG criteria have been evaluated as predictors of a positive SCBPT, such as the ß-angle, the α-angle, the duration of the base of the triangle at 5 mm from the r'-wave (DBT- 5 mm), the duration of the base of the triangle at the isoelectric line (DBT- iso), and the triangle base/height ratio. The aim of our study was to test all previously proposed ECG criteria in a large cohort study and to evaluate an r'-wave algorithm for predicting a BrS diagnosis after an SCBPT. We enrolled all patients who consecutively underwent SCBPT using flecainide from January 2010 to December 2015 in the test cohort and from January 2016 to December 2021 in the validation cohort. We included the ECG criteria with the best diagnostic accuracy in relation to the test cohort in the development of the r'-wave algorithm (ß-angle, α-angle, DBT- 5 mm, and DBT- iso.) Of the total of 395 patients enrolled, 72.4% were male and the average age was 44.7 ± 13.5 years. Following the SCBPTs, 24.1% of patients (n = 95) were positive and 75.9% (n = 300) were negative. ROC analysis of the validation cohort showed that the AUC of the r'-wave algorithm (AUC: 0.92; CI 0.85-0.99) was significantly better than the AUC of the ß-angle (AUC: 0.82; 95% CI 0.71-0.92), the α-angle (AUC: 0.77; 95% CI 0.66-0.90), the DBT- 5 mm (AUC: 0.75; 95% CI 0.64-0.87), the DBT- iso (AUC: 0.79; 95% CI 0.67-0.91), and the triangle base/height (AUC: 0.61; 95% CI 0.48-0.75) (p < 0.001), making it the best predictor of a BrS diagnosis after an SCBPT. The r'-wave algorithm with a cut-off value of ≥2 showed a sensitivity of 90% and a specificity of 83%. In our study, the r'-wave algorithm was proved to have the best diagnostic accuracy, compared with single electrocardiographic criteria, in predicting the diagnosis of BrS after provocative testing with flecainide.


Asunto(s)
Síndrome de Brugada , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Síndrome de Brugada/diagnóstico , Bloqueadores de los Canales de Sodio/farmacología , Bloqueadores de los Canales de Sodio/uso terapéutico , Flecainida , Estudios de Cohortes , Electrocardiografía , Algoritmos
16.
Pacing Clin Electrophysiol ; 45(12): 1409-1414, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36214206

RESUMEN

INTRODUCTION: The implantable cardioverter defibrillator (ICD) has been demonstrated to successfully prevent sudden cardiac death (SCD) in children and young adults. A wide range of device-related complications/malfunctions have been described, which depend on the intrinsic design of the defibrillation system (transvenous-implantable cardioverter defibrillator [TV-ICD] vs. subcutaneous-implantable cardioverter defibrillator [S-ICD]). OBJECTIVE: To compare the device-related complications and inappropriate shocks with TV-ICD versus S-ICD. METHODS AND RESULTS: Electronic databases were queried for studies focusing on the prevention of SCD in children and young adults with TV-ICD or S-ICD. The effect size was estimated using a random-effect model as odds ratio (OR) and relative 95% confidence interval (CI). The primary endpoint was a composite of any device-related complications and inappropriate shocks. We identified a total of five studies including 236 patients (Group S-ICD: 76 patients; Group TV-ICD: 160 patients) with a mean follow-up time of 54.2 ± 24.9 months. S-ICD implantation contributed to a significant reduction in the risk of the primary endpoint of any device-related complications and inappropriate shocks (OR: 0.18; 95% CI: 0.05-0.73; p = .02). S-ICD was also associated with a significantly lower incidence of inappropriate shocks (OR: 0.28; 95% CI: 0.11-0.74; p = .01) and lead-related complications (OR: 0.18; 95% CI: 0.05-0.66; p = .01). A trend toward a higher risk of pocket complications (OR: 5.91; 95% CI: 0.98-35.63; p = .05) was recorded in patients with S-ICD. CONCLUSION: Children and young adults undergoing S-ICD implantation may have a lower risk of a composite of device-related complications and inappropriate shocks, compared to TV-ICD patients.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Niño , Humanos , Desfibriladores Implantables/efectos adversos , Adolescente , Muerte Súbita Cardíaca/prevención & control
17.
J Electrocardiol ; 73: 52-54, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35660341

RESUMEN

Atrial fibrillation (AF) is the most common cardiac arrhythmia in adults with substantial morbidity and mortality. The diagnosis of AF is established by electrocardiogram showing heart rhythm without clear P waves with irregular RR intervals. The electrocardiographic diagnosis of AF is not always easy and can still hide pitfalls even for the most experienced cardiologist. We present the case of an 86 years old patient admitted to our hospital for Covid-19 infection affected by dilated cardiomyopathy with an electrocardiogram showing a non-specific intraventricular conduction delay mimicking sinus rhythm in the presence of AF.


Asunto(s)
Fibrilación Atrial , COVID-19 , Adulto , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Electrocardiografía , Bloqueo Cardíaco , Ventrículos Cardíacos , Humanos
18.
J Electrocardiol ; 74: 46-53, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35964522

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) is the main cardiac cause of stroke, but it frequently remains undetected. In patients with cryptogenic stroke an Holter electrocardiogram (ECG) monitoring for AF is recommended. OBJECTIVE: To evaluate the prognostic role of Non-Conducted Premature Atrial Complexes (ncPACs) recorded on Holter ECG. METHODS: We prospectively enrolled consecutive patients admitted to the Stroke Unit of our hospital with a diagnosis of cryptogenic stroke between December 2018 and January 2020; all patients underwent 24-h Holter ECG monitoring during hospitalization. Two follow-up visits were scheduled, including a 24-h Holter ECG at 3 and 6 months to detect AF. RESULTS: Among 112 patients, 58% were male with an average age of 72.2 ± 12.2 years. At follow-up, AF was diagnosed in 21.4% of the population. The baseline 24-h Holter ECG burden of ncPACs and Premature Atrial Complexes (PACs) was higher in patients with AF detected on follow-up (13.5 vs 2, p = 0.001; 221.5 vs 52; p = 0.01). ROC analysis showed that ncPACs had the best diagnostic accuracy in predicting AF (AUC:0.80; 95% CI 0.68-0.92). Cut-off value of ≥7 for ncPACs burden showed the highest accuracy with sensitivity of 62.5% and specificity 97.7% to predict AF onset at follow-up. Moreover, at multivariate Cox-proportional hazard analysis ncPACs burden ≥7 was a powerful independent predictor of AF onset (HR 12.4; 95% CI 4.8-32.8; p < 0.0001). CONCLUSIONS: NcPACs burden ≥7 represents a new predictor of AF that could guide the screening of this arrhythmia in cryptogenic stroke patients.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Electrocardiografía , Accidente Cerebrovascular/etiología
19.
Monaldi Arch Chest Dis ; 90(2)2020 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-32344995

RESUMEN

Since its introduction right ventricular apical (RVA) pacing has been the mainstay in cardiac pacing. However, in recent years there has been an upsurge of interest in permanent His bundle pacing (HBP), given the scientific evidence of the harmful role of dyssynchronous ventricular activation, induced by RVA pacing, in promoting the onset of heart failure and atrial fibrillation. After an intermediate period in which attention was focused on algorithms aimed at minimizing ventricular pacing, with partially inadequate and harmful results, scientific attention shifted to HBP, which proved to ensure a physiological electro-mechanical activation of the ventricles. The encouraging results obtained have allowed the introduction of HBP in recent guidelines for cardiac pacing in patients with bradicardia and cardiac conduction delay. Recent studies have also demonstrated the potential of HBP in patients with left bundle branch block and heart failure. HBP is promising as an attractive way to achieve physiological stimulation in patients with an indication for cardiac resynchronization therapy (CRT). Comparative studies of HB-CRT and biventricular pacing have shown similar results in numerically modest cohorts, although HB-CRT has been shown to promote better ventricular electrical resynchronization as demonstrated by a greater QRS narrowing. A widespread use of this pacing tecnique also depends on improvements in technology, as well as further validation of effectiveness in large randomised clinical trials.


Asunto(s)
Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Terapia de Resincronización Cardíaca/métodos , Ventrículos Cardíacos/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Bradicardia/fisiopatología , Bloqueo de Rama/terapia , Cateterismo Cardíaco/métodos , Trastorno del Sistema de Conducción Cardíaco/fisiopatología , Electrocardiografía/métodos , Insuficiencia Cardíaca/fisiopatología , Humanos , Evaluación de Resultado en la Atención de Salud
20.
Monaldi Arch Chest Dis ; 89(1)2019 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-30968659

RESUMEN

Heart failure is a widespread disease in the western world whose incidence and prevalence are constantly increasing, mainly involving the more advanced age groups. Cardiac resynchronization therapy (CRT) has been shown able to reduce sudden cardiac death and all-cause mortality in patients with heart failure and reduced ejection fraction. Elderly patients are generally under-represented in the clinical trials aimed to evaluate the efficacy of CRT and, chiefly, of implantable cardiac defibrillator (ICD). The simultaneous presence of confounding factors such as co-morbidities, polypharmacy, changes in cognitive status, frailty, are the most important causes for the exclusion of subjects of advanced age from RCTs on the ICD or CRT implant. Current guidelines do not suggest any upper age limit for ICD and CRT but recommend avoiding their use in frail older patients with a life expectancy of less than 1 year. Data from the literature show that CRT has equal dignity in both the elderly and the young, in fostering effective functional and morphological improvements, also suggesting that, in older patients, CRT-D may have little practical value compared to CRT-P given the low incidence of arrhythmic death. Nevertheless, it is necessary to develop RCTs that consider aspects of the elderly patient in relation to CRT such as functional, cognitive and nutritional status.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Factores de Edad , Anciano , Muerte Súbita Cardíaca/prevención & control , Anciano Frágil , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Guías de Práctica Clínica como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA