Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38639143

RESUMEN

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Asunto(s)
Técnicas de Ablación , Cateterismo Cardíaco , Cardiomiopatía Hipertrófica , Etanol , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Humanos , Estudios Retrospectivos , Masculino , Etanol/administración & dosificación , Etanol/efectos adversos , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/mortalidad , Cardiomiopatía Hipertrófica/terapia , Cardiomiopatía Hipertrófica/cirugía , Cardiomiopatía Hipertrófica/fisiopatología , Femenino , Resultado del Tratamiento , Técnicas de Ablación/efectos adversos , Técnicas de Ablación/mortalidad , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Persona de Mediana Edad , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Tiempo , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Recuperación de la Función , Anciano de 80 o más Años , Tabiques Cardíacos/diagnóstico por imagen , Tabiques Cardíacos/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad
2.
Catheter Cardiovasc Interv ; 101(1): 164-169, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378598

RESUMEN

Aspiration thrombectomy with the AngioVac is approved for percutaneous removal of thrombus in the venous system. While not approved for aspiration of thrombus or other mass in the left heart or arterial system, it has been used in that setting. Patients with left heart or arterial mass are often deemed unfavorable for surgery and treated conservatively. This may not be the best option for all patients, as some may have lesions that represent a short-term increased risk of complications, for which intervention and aspiration could be considered reasonable. Unfortunately, femoral arteries sizes often cannot accommodate the Angiovac current aspiration cannula dimensions. Here, we demonstrated trans-caval approach for aspiration thrombectomy of extensive aortic mobile plaque and thrombus.


Asunto(s)
Placa Aterosclerótica , Trombosis , Humanos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Resultado del Tratamiento , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/cirugía , Trombectomía/efectos adversos
3.
Echocardiography ; 40(11): 1285-1291, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37842844

RESUMEN

Left ventricular pseudoaneurysm (PSA) after surgical aortic valve replacement (AVR) is a known but uncommon complication. It is associated with risks such as thromboembolism and life-threatening rupture. Surgical repair has traditionally been utilized in low-risk patients but transcatheter closure has become a promising therapeutic option. This case report describes the utility of multimodality imaging in pre-, intra-, and post-procedural evaluation of transcatheter PSA closure and is among the first to demonstrate the utility of 3D print model.


Asunto(s)
Aneurisma Falso , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Imagen Multimodal , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 100(1): 163-168, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35568977

RESUMEN

OBJECTIVE: We aim to report on the efficacy and safety of large bore venous access (LBVA) preclosure with Perclose™ (Abbott Vascular Devices) suture-mediated device use following transcatheter edge-to-edge (TEER) and replacement (TMVR). BACKGROUND: Patients requiring TEER and TMVR require LBVA. Clinical outcome data on the use of suture-mediated devices for LBVA site closure are limited. METHODS: Between 2012 and 2019, 354 consecutive high-risk patients with mitral valvular heart disease underwent TEER (n = 287) with MitraClip and TMVR (n = 67) with Edwards Sapien Valves. Patients had LBVA with 24 or 16 French sheaths. All patients underwent preclosure of LBVA except for one that underwent manual hemostasis. RESULTS: There were no closure device failures. None of the cases required surgical repair of the access site following venous preclosure. Two cases had large hematomas (>6 cm) following Perclose in each group. Six cases had small hematomas (<6 cm and >2 cm) with three in each group. There was one major bleeding using Mitral Valve Academic Research Consortium 2 definition (retroperitoneal bleed from arterial puncture) unrelated to the venous closure. Transfusion related to vascular access complication was required in five cases. There were two immediate acute deep venous thromboses postprocedure; one of which occurred after preclosure. There were no arteriovenous malformations, pseudoaneurysms, or access site infections reported following Perclose. CONCLUSION: In this large sample size analysis, Proglide preclosure technique is a feasible and safe alternative approach to achieving hemostasis after removal of LBVA sheaths in patients undergoing TEER and TMVR. Randomized trials are needed to compare the different modalities of hemostasis.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Dispositivos de Cierre Vascular , Enfermedades de las Válvulas Cardíacas/cirugía , Hematoma/etiología , Hemorragia/etiología , Hemorragia/prevención & control , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Técnicas de Sutura/efectos adversos , Resultado del Tratamiento , Dispositivos de Cierre Vascular/efectos adversos
5.
J Card Surg ; 37(9): 2937-2942, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33533038

RESUMEN

BACKGROUND: As transcatheter aortic valve replacement (TAVR) procedures increase, more data is available on the development of conduction abnormalities requiring permanent pacemaker (PPM) implantation post-TAVR. Mechanistically, new pacemaker implantation and incidence of associated tricuspid regurgitation (TR) post-TAVR is not well understood. Studies have evaluated the predictability of patient anatomy towards risk for needing permanent pacemaker (PPM) post-TAVR; however, little has been reported on new PPM and TR in patients post-TAVR. METHODS: This retrospective study identified patients at our health system who underwent PPM following TAVR from January 2014 to June 2018. Data from both TAVR and PPM procedures as well as patient demographics were collected. Echocardiographic data before TAVR, between TAVR and PPM placement, and the most recent echocardiogram at the time of chart review were analyzed. RESULTS: Of 796 patients who underwent TAVR between January 2014 and June 2018, 89 patients (11%) subsequently required PPM. Out of the 89 patients who required PPM implantation, 82 patients had pre-TAVR and 2-year post-TAVR echocardiographic imaging data. At baseline, 22% (18/82) of patients had at least moderate TR. At 2-year post-TAVR echocardiographic imaging follow-up; 27% (22/82) of patients had at least moderate TR. Subgroup analysis was performed according to the TAVR valve size implanted. In patients who received a TAVR device < 29 mm in diameter in size, 25% (11/44) had worsening TR. In patients who received a TAVR device ≥ 29 mm in diameter, 37% (14/38) had worsening TR. CONCLUSION: We have demonstrated a patient population that may be predisposed to developing worsening TR and right heart function after TAVR and Pacemaker implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/etiología
6.
Catheter Cardiovasc Interv ; 98(5): 975-980, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34343410

RESUMEN

OBJECTIVE: To determine the rate and clinical outcomes of post-TAVR VSD. BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a safe and established procedure for patients with severe symptomatic aortic stenosis. Ventricular septal defect (VSD) is a rare complication of TAVR. The rate of post-TAVR VSD and patient outcomes are not well known. METHODS: A retrospective record review of VSD cases occurring after all TAVRs performed between January 2012 and September 2020 at one urban US tertiary hospital. VSD rate and early- and long-term outcomes were analyzed. Computed tomography images taken before TAVR and transthoracic echocardiograms done before and after each procedure were analyzed. RESULTS: Of the 1908 patients who underwent TAVR in the study period, 7 patients (0.37%) had post-procedure VSD. The average patient age was 77 ± 11 years with average society of thoracic surgeons short-term risk score of 6%. All 7 implanted valves were balloon-expandable. Of the 7 TAVR procedures, 5 were performed on a native tricuspid valve, 1 was performed on a native bicuspid valve, and 1 was done as a "valve-in-valve" procedure on a prior surgical bioprosthetic valve. All VSDs were small and restrictive in nature. Right heart failure in a patient with preexisting right ventricular dysfunction occurred in 1 (13%) patient who died. The remaining 6 patients (86%) were discharged. All 6 patients (86%) were alive and stable at 1 year follow-up, reporting improvement in symptoms (NYHA class I-II), with no evidence of right ventricular dysfunction. CONCLUSION: VSD is a rare complication of TAVR. Hemodynamic and clinical sequelae in majority of the patients in this study did not result in mortality. Proper imaging techniques and appropriate pre-procedure planning are needed to decrease the incidence of VSD formation post-TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Defectos del Tabique Interventricular , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/epidemiología , Defectos del Tabique Interventricular/cirugía , Humanos , Incidencia , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
J Cardiothorac Vasc Anesth ; 34(8): 2060-2068, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32127264

RESUMEN

OBJECTIVES: To evaluate whether a preoperative diagnosis of atrial septal defect (ASD) or patent foramen ovale (PFO) is associated with perioperative stroke in noncardiac surgery and their outcomes. DESIGN: Retrospective cohort analysis. SETTING: United States hospitals. PARTICIPANTS: Adults patients (≥18 years old) who underwent major noncardiac surgery from 2010 to 2015 were identified using the Healthcare Cost and Utilization Project's National Readmission Database. INTERVENTIONS: Preoperative diagnosis of ASD or patent foramen ovale. MEASUREMENTS AND MAIN RESULTS: Among the 19,659,161 hospitalizations for major noncardiac surgery analyzed, 12,248 (0.06%) had a preoperative diagnosis of ASD/PFO. Perioperative ischemic stroke occurred in 723 (5.9%) of patients with ASD/PFO and 373,291 (0.02%) of those without ASD/PFO (adjusted odds ratio [aOR], 16.7; 95% confidence interval [CI]: 13.9-20.0). Amongst the different types of noncardiac surgeries, obstetric, endocrine, and skin and burn surgery were associated with higher risk of stroke in patients with pre-existing ASD/PFO. Moreover, patients with ASD/PFO also had an increased in-hospital mortality (aOR, 4.6, 95% CI: 3.6-6.0), 30-day readmission (aOR, 1.2, 95% CI: 1.04-1.38), and 30-day stroke (aOR, 7.2, 95% CI: 3.1-16.6). After adjusting for atrial fibrillation, ischemic stroke remained significantly high in the ASD/PFO group (aOR: 23.7, 95%CI 19.4-28.9), as well as in-hospital mortality (aOR: 5.6, 95% CI 4.1-7.7), 30-day readmission (aOR: 1.19, 95%CI 1.0-1.4), and 30-day stroke (aOR: 9.3, 95% CI 3.7-23.6). CONCLUSIONS: Among adult patients undergoing major noncardiac surgery, pre-existing ASD/PFO is associated with increased risk of perioperative ischemic stroke, in-hospital mortality, 30-day stroke, and 30-day readmission after surgery.


Asunto(s)
Isquemia Encefálica , Foramen Oval Permeable , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Adolescente , Adulto , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/epidemiología , Isquemia Encefálica/etiología , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico , Foramen Oval Permeable/epidemiología , Humanos , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Estados Unidos
8.
Heart Lung Circ ; 29(7): e147-e156, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32089491

RESUMEN

BACKGROUND: Whether a volume-outcome relationship, that is, higher volume centres have better outcomes compared with lower volume hospitals, exists in transcatheter aortic valve implantation (TAVI) has not yet been systematically explored. METHODS: We performed a systematic review and meta-analysis to evaluate whether highest or intermediate annual TAVI volume hospitals has better short-term (in-hospital or 30-days) mortality compared with the lowest volume hospitals. Odds ratio (OR) and 95% confidence interval (CI) was calculated with the Mantel-Haenszel method. RESULTS: We identified 10 publications from nine different countries including TAVI performed between 2005-2017. Included patients were mainly high-risk cohorts. We included five and six studies to assess volume-outcome relationship in the highest and intermediate volume hospitals compared with the lowest volume hospitals, respectively. Our results showed that in both the highest (OR 0.66, 95%CI 0.53-0.83, p=0.0003, I2=78%) and intermediate (OR 0.85, 95%CI 0.79-0.92, p<0.0001, I2=0%) volume hospitals, there was a statistically significant volume-outcome relationship for short-term mortality compared with the lowest volume hospitals. CONCLUSIONS: Our review suggests a significant volume-outcome relationship post-TAVI in both the highest and intermediate volume hospitals compared with the lowest volume hospitals mainly in high surgical risk patients. The high heterogeneity in this relationship between the highest and the lowest volume hospitals warrant cautious interpretation. Whether this relationship remains significant in low-risk cohort requires further study.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Hospitales/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Humanos
9.
Catheter Cardiovasc Interv ; 94(2): 264-273, 2019 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-30536799

RESUMEN

OBJECTIVES: To assess the efficacy and safety of transradial (TR) versus transfemoral (TF) percutaneous coronary intervention (PCI) in left main (LM) lesion. BACKGROUND: TR-PCI is the preferred approach compared with TF approach because of less bleeding risk. LM-PCI is often challenging because of the anatomical complexity and uniqueness of supplying a large myocardium territory. We performed a systematic review and meta-analysis to assess the safety and efficacy of TR-PCI compared with TF-PCI of the LM lesions. METHODS: A comprehensive literature search of PUBMED, EMBASE, and Cochrane database was conducted to identify studies that reported the comparable outcomes between both approaches. Odds ratio (OR) and 95% confidence interval (CI) was calculated using the Mantel-Haenszel method. RESULTS: A total of eight studies were included in the quantitative meta-analysis. TR-PCI resulted in lower bleeding risk (OR 0.31, 95%CI 0.18-0.52, P < 0.01, I2 = 0%) while maintaining similar procedural success rate, target lesion revascularization, myocardial infarction, stent thrombosis, and all-cause mortality during the study follow-up period. CONCLUSIONS: TR-PCI may achieve similar efficacy with decreased bleeding risk compared to TF-PCI in LM lesions. When operator experience and anatomical complexity are favorable, TR approach is an attractive alternative access over TF approach in LM-PCI.


Asunto(s)
Cateterismo Cardíaco , Cateterismo Periférico , Enfermedad de la Arteria Coronaria/terapia , Arteria Femoral , Intervención Coronaria Percutánea , Arteria Radial , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Observacionales como Asunto , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/mortalidad , Punciones , Factores de Riesgo , Stents , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 93(5): 954-962, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30408309

RESUMEN

OBJECTIVES: To assess the in-hospital outcomes of transcatheter aortic valve replacement (TAVR) vs. surgical aortic valve replacement (SAVR) in non-teaching hospitals. BACKGROUND: TAVR has become widely available in the United States. However, the comparative outcomes of TAVR vs. SAVR in non-teaching hospitals are largely under explored. METHODS: We queried the Nationwide Inpatient Sample database from 2011 to September 2015 to identify those who were 50 years or above and underwent either trans-arterial TAVR or SAVR at non-teaching hospital. In-hospital clinical outcomes were compared with odds ratio (OR) in propensity-matched cohorts. RESULTS: We identified un-weighted 957 and 7,465 SAVR admissions. In propensity-matched model, 596 admissions in each arm were included for final analysis. In-patient mortality (3.9 vs. 2.5%, OR 1.54, P = 0.34), acute kidney injury requiring dialysis (2.2 vs. 2.7%, OR 0.80, P = 0.57), stroke (2.0 vs. 3.2%, OR 0.61, P = 0.20), and pacemaker placement (8.9 vs. 6.4%, OR 1.47, P = 0.09) was similar between TAVR and SAVR. Sub-group analysis showed that female and those with prior coronary artery bypass surgery had higher risk of in-patient morality in TAVR admission. Cost was higher (59,103 vs. 53,411 dollars, P = 0.006) but length of stay was shorter in TAVR (6.9 vs. 10.2 days, P < 0.001). CONCLUSIONS: TAVR conferred similar in-hospital mortality and major peri-procedural complications compared with SAVR in non-teaching hospitals. For those with limited access to teaching hospitals, non-teaching hospitals appear to be a reasonable option for candidates of aortic valve replacement for severe aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Hospitales , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estudios Transversales , Bases de Datos Factuales , Femenino , Accesibilidad a los Servicios de Salud , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
11.
Vascular ; 27(1): 90-97, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30056785

RESUMEN

BACKGROUND: To study trends in the clinical presentation, electrocardiograms, and diagnostic imaging in patients with pulmonary embolism presenting as ST segment elevation. METHODS: We performed a systematic literature search for all reported cases of pulmonary embolism mimicking ST-elevation myocardial infarction. Pre-specified data such as clinical presentation, electrocardiogram changes, transthoracic echocardiographic findings, cardiac biomarkers, diagnostic imaging, therapy, and outcomes were collected. RESULTS: We identified a total of 34 case reports. There were 23 males. Mean age of the population was 56.5 ± 15.5 years. Patients presented with dyspnea (76.4%), chest pain (63.6%), and tachycardia (71.4%). All patients presented with ST-elevations, with the most common location being in the anterior-septal distribution, lead V3 (74%), V2 (71%), V1 (62%) and V4 (47%). ST-segment elevations in the inferior distribution were present in lead II (12%), III (18%), and aVF (21%). Presentation was least likely in the lateral distribution. Troponin was elevated in 78.9% of cases. Right ventricular strain was the most common echocardiographic finding. Over 80% of patients had findings consistent with elevated right ventricular pressure, with 50% reported RV dilatation and 20% RV hypokinesis. The most commonly used imaging modality was contrast-enhanced pulmonary angiography. There was a greater incidence of bilateral compared to unilateral pulmonary emboli (72.4% vs. 10%). About 65% patients received anticoagulation and 36.3% were treated with thrombolytics. Forty-six percent of patients required intensive care and 18.7% intubation. Overall mortality was 25.8%. CONCLUSIONS: A review of the literature reveals that in patients presenting with pulmonary embolism, electrocardiogram findings of ST-segment elevations will occur predominantly in the anterior-septal distribution.


Asunto(s)
Angiografía por Tomografía Computarizada , Ecocardiografía , Electrocardiografía , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico , Infarto del Miocardio con Elevación del ST/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Anticoagulantes/uso terapéutico , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Arteria Pulmonar/efectos de los fármacos , Arteria Pulmonar/fisiopatología , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/tratamiento farmacológico , Embolia Pulmonar/fisiopatología , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/fisiopatología , Terapia Trombolítica , Resultado del Tratamiento
12.
Vascular ; 27(1): 78-89, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30501582

RESUMEN

BACKGROUND: Bivalirudin may be an effective alternative anticoagulant to heparin for use in percutaneous peripheral interventions. We aimed to compare the safety and efficacy of bivalirudin versus heparin as the procedural anticoagulant agent in patients undergoing percutaneous peripheral intervention. METHODS: For this meta-analysis and systematic review, we conducted a search in PubMed, Medline, Embase, and Cochrane for all the clinical studies in which bivalirudin was compared to heparin as the procedural anticoagulant in percutaneous peripheral interventions. Outcomes studied included all-cause mortality, all-bleeding, major and minor bleeding, and access site complications. RESULTS: Eleven studies were included in the analysis, totaling 20,137 patients. There was a significant difference favoring bivalirudin over heparin for all-cause mortality (risk ratio 0.58, 95% CI 0.39-0.87), all-bleeding (risk ratio 0.62, 95% CI 0.50-0.78), major bleeding (risk ratio 0.61, 95% CI 0.39-0.96), minor bleeding (risk ratio 0.66, 95% CI 0.47-0.92), and access site complications (risk ratio 0.66, 95% CI 0.51-0.84). There was no significant difference in peri-procedural need for blood transfusions (risk ratio 0.79, 95% CI 0.57-1.08), myocardial infarction (risk ratio 0.87, 95% CI 0.59-1.28), stroke (risk ratio 0.77, 95% CI 0.59-1.01), intracranial bleeding (risk ratio 0.77, 95% CI 0.29-2.02), or amputations (OR 0.75, 95% CI 0.53-1.05). CONCLUSION: Our meta-analysis suggests that bivalirudin use for percutaneous peripheral interventions is associated with lower all-cause mortality, bleeding, and access site complications as compared to heparin. Further large randomized trials are needed to confirm the current results.


Asunto(s)
Anticoagulantes/administración & dosificación , Antitrombinas/administración & dosificación , Cateterismo Periférico , Procedimientos Endovasculares , Heparina/administración & dosificación , Hirudinas/administración & dosificación , Fragmentos de Péptidos/administración & dosificación , Enfermedad Arterial Periférica/terapia , Trombosis/prevención & control , Anciano , Anticoagulantes/efectos adversos , Antitrombinas/efectos adversos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Hemorragia/inducido químicamente , Heparina/efectos adversos , Hirudinas/efectos adversos , Humanos , Masculino , Fragmentos de Péptidos/efectos adversos , Proteínas Recombinantes/administración & dosificación , Proteínas Recombinantes/efectos adversos , Medición de Riesgo , Factores de Riesgo , Trombosis/etiología , Trombosis/mortalidad , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 29(5): 771-779, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29399923

RESUMEN

INTRODUCTION: Monomorphic ventricular tachycardia (VT) is an important cause of morbidity and mortality. Use and outcome data of catheter ablation for VT in nonischemic cardiomyopathy (NICM) are limited. METHODS AND RESULTS: We obtained data from the 2003-2014 National Inpatient Sample databases. We used propensity score matching to compare patients undergoing catheter ablation versus medical therapy of VT related to NICM, and described the temporal trends in utilization and in-hospital outcomes of catheter ablation of VT in patients with NICM in the United States. From 2003 to 2014, of 133,529 patients hospitalized with the principal diagnosis of VT in NICM, 14,651 (11.0%) underwent catheter ablation. In this period, there was an increasing trend in utilization of catheter ablation (9.3% in 2003-2004 to 12.1% in 2003-2014, adjusted OR [per year], 1.12; 95% CI, 1.08-1.16; Ptrend  < 0.001). After propensity score matching, in-hospital mortality occurred in 172 of 14,318 (1.2%) patients in the catheter ablation group, compared with 297 of 14,156 (2.1%) of patients undergoing medical therapy (47% lower; 43% relative difference [adjusted OR, 0.53; 95% CI, 0.43-0.66]). CONCLUSIONS: In patients with NICM, catheter ablation of VT is associated with lower in-hospital mortality compared with those managed medically. The utilization rates of CA for VT related to NICM have increased in the past decade. Adequately powered randomized trials will be necessary to confirm these findings.


Asunto(s)
Antiarrítmicos/uso terapéutico , Cardiomiopatías/epidemiología , Ablación por Catéter/tendencias , Hospitalización/tendencias , Taquicardia Ventricular/cirugía , Adulto , Anciano , Antiarrítmicos/efectos adversos , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Ablación por Catéter/efectos adversos , Ablación por Catéter/mortalidad , Bases de Datos Factuales , Femenino , Mortalidad Hospitalaria/tendencias , Humanos , Pacientes Internos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
14.
Catheter Cardiovasc Interv ; 91(2): 330-342, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28738447

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is typically performed under general anesthesia (GA). However, there is increasing data supporting the safety of performing TAVR under local anesthesia/conscious sedation (LA). We performed a meta-analysis to gain better understanding of the safety and efficacy of LA versus GA in patients with severe aortic stenosis undergoing TAVR. METHODS AND RESULTS: We comprehensively searched EMBASE, PubMed, and Web of Science. Effect sizes were summarized using risk ratios (RRs) difference of the mean (DM), and 95% CIs (confidence intervals) for dichotomous and continuous variables respectively. Twenty-six studies and 10,572 patients were included in the meta-analysis. The use of LA for TAVR was associated with lower overall 30-day mortality (RR, 0.73; 95% CI, 0.57-0.93; P = 0.01), use of inotropic/vasopressor drugs (RR, 0.45; 95% CI, 0.28-0.72; P < 0.001), hospital length of stay (LOS) (DM, -2.09; 95% CI, -3.02 to -1.16; P < 0.001), intensive care unit LOS (DM, -0.18; 95% CI, -0.31 to -0.04; P = 0.01), procedure time (DM, -25.02; 95% CI, -32.70 to -17.35; P < 0.001); and fluoroscopy time (DM, -1.63; 95% CI, -3.02 to -0.24; P = 0.02). No differences were observed between LA and GA for stroke, cardiovascular mortality, myocardial infarction, permanent pacemaker implantation, acute kidney injury, paravalvular leak, vascular complications, major bleeding, procedural success, conduction abnormalities, and annular rupture. CONCLUSION: Our meta-analysis suggests that use of LA for TAVR is associated with a lower 30-day mortality, shorter procedure time, fluoroscopy time, ICU LOS, hospital length of stay, and reduced need for inotropic support.


Asunto(s)
Anestesia General , Anestesia Local , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Anestesia General/efectos adversos , Anestesia General/mortalidad , Anestesia Local/efectos adversos , Anestesia Local/mortalidad , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Tiempo de Internación , Masculino , Tempo Operativo , Complicaciones Posoperatorias/terapia , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
15.
Europace ; 20(1): 104-115, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28575378

RESUMEN

Aims: To compare the long-term outcomes of standard ablation of stable ventricular tachycardia (VT) vs. substrate modification, and of complete vs. incomplete substrate modification in patients with structural heart disease (SHD) presenting with VT. Methods and results: An electronic search was performed using major databases. The main outcomes were a composite of long-term ventricular arrhythmia (VA) recurrence and all-cause mortality of standard ablation of stable VT vs. substrate modification, and long-term VA recurrence in complete vs. incomplete substrate modification. Six studies were included for the comparison of standard ablation of stable VT vs. substrate modification, with a total of 396 patients (mean age 63 ± 10 years, 87% males), and seven studies were included to assess the impact of extensive substrate modification, with a total of 391 patients (mean age 64 ± years, 90% males). More than 70% of all the patients included had ischaemic cardiomyopathy. Substrate modification was associated with decreased composite VA recurrence/all-cause mortality compared to standard ablation of stable VTs [risk ratio (RR) 0.57, 95% confidence interval (CI) 0.40-0.81]. Complete substrate modification was associated with decreased VA recurrence as compared to incomplete substrate modification (RR 0.39, 95% CI 0.27-0.58). Conclusion: In patients with SHD who had VT related mainly to ischaemic substrates, there was a significantly lower risk of the composite primary outcome of long-term VA recurrence and all-cause mortality among those undergoing substrate modification compared to standard ablation. Long-term success is improved when performing complete substrate modification.


Asunto(s)
Técnicas de Ablación , Taquicardia Ventricular/cirugía , Técnicas de Ablación/efectos adversos , Técnicas de Ablación/mortalidad , Adulto , Anciano , Causas de Muerte , Distribución de Chi-Cuadrado , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Recurrencia , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
16.
Echocardiography ; 35(11): 1872-1877, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30324627

RESUMEN

Most common congenital anatomical abnormalities of the subvalvular apparatus (papillary muscles and chordae tendineae) are parachute or parachute like mitral valve. This is more commonly reported among the pediatric population as they develop heart failure symptoms shortly after birth. Reports of adult cases are rare and incidental. Multimodality imaging has an important role in evaluating such anatomical abnormalities, and identification of possible related complications. We are describing a rare atypical variant of parachute like mitral valve.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Ecocardiografía/métodos , Electrocardiografía/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Músculos Papilares/anomalías , Músculos Papilares/diagnóstico por imagen , Adulto , Humanos , Masculino
17.
J Interv Cardiol ; 30(6): 586-594, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28833456

RESUMEN

BACKGROUND: Bivalirudin may be an effective anticoagulation alternative to heparin as anticoagulant agent in percutaneous transcatheter aortic valve interventions (PAVI). We aimed to compare safety and efficacy of bivalirudin versus heparin as the procedural anticoagulant agent in patients undergoing PAVI. METHODS: We conducted an electronic database search of all published data. The primary efficacy endpoints were all-cause mortality, cardiovascular mortality, myocardial infarction, and stroke. Safety endpoints include major and life-threatening bleed according to VARC and BARC bleeding, blood transfusion, vascular complications, and acute kidney injury. Odds ratios (OR) and 95% confidence intervals (CI) computed using the Mantel-Haenszel method. RESULTS: Three studies (n = 1690 patients) were included, one randomized trial and two observational studies. There was a significant difference favoring bivalirudin over heparin for myocardial infarction (OR 0.41, 95%CI 0.20-0.87). There was no significant difference in all-cause mortality at 30 days (OR 0.97, 95%CI 0.62-1.52), cardiovascular mortality (OR 1.03, 95%CI 0.52-2.05), stroke (OR 1.23, 95%CI 0.62-2.46), vascular complications (OR 0.96, 95%CI 0.70-1.32), acute kidney injury (OR 1.03, 95%CI 0.53-2.00), blood transfusion (OR 0.67, 95% CI 0.45-1.01), major and life-threatening bleed (OR 0.74, 95%CI 0.37-1.49), and BARC bleeding (OR 0.52, 95%CI 0.23-1.18). CONCLUSIONS: In patient undergoing aortic valve interventions, no difference was seen between the use of bivalirudin and heparin as the procedural anticoagulant agent, except for a significant lower myocardial infarction events when bivalirudin was used. Further large randomized trials are needed to confirm current results.


Asunto(s)
Anticoagulantes/uso terapéutico , Heparina/uso terapéutico , Fragmentos de Péptidos/uso terapéutico , Tromboembolia/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica , Estenosis de la Válvula Aórtica/terapia , Valvuloplastia con Balón , Hirudinas , Humanos , Proteínas Recombinantes/uso terapéutico
18.
J Heart Valve Dis ; 26(1): 114-117, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28544841

RESUMEN

Transcatheter valve-in-valve (VIV) implantation has been recently proposed as an alternative to surgical reoperative aortic valve replacement in patients with a failing aortic bioprosthesis. Experience with transcatheter VIV implantation at other valve positions is very limited. Herein is reported the case of an 18-year-old man with Ebstein's anomaly and severe tricuspid valve (TV) regurgitation status after bioprosthetic valve replacement, who developed new dyspnea on exertion three years after the initial valve replacement. Transesophageal echocardiography showed a severely dilated right atrium and new TV stenosis with an immobile leaflet. The patient underwent successful VIV implantation of a 29-mm SAPIEN XT bioprosthetic valve, with resolution of symptoms and no residual TV regurgitation or stenosis at the two-year follow up. Video 1: Degenerative bioprosthetic tricuspid valve. TEE showing the degenerative bioprosthetic tricuspid valve, and color Doppler during systole showing severe tricuspid regurgitation. Video 2: Degenerative bioprosthetic tricuspid valve. Three-dimensional TEE showing stenosis with an immobile leaflet creating a coaptation defect, viewed from the right atrium. Video 3: Transcatheter VIV replacement with a 29-mm Edwards SAPIEN XT deployed within the tricuspid valve prosthesis. Final result after valve implantation, demonstrating a patent valve orifice, and appropriate apposition of transcatheter valve within a pre-existing surgical Carpentier-Edwards bioprosthetic valve, viewed from the right ventricle. Video 4: Transcatheter VIV replacement with a 29-mm Edwards SAPIEN XT deployed within the tricuspid valve prosthesis. Final result after valve implantation, demonstrating a patent valve orifice, and appropriate apposition of transcatheter valve within a pre-existing surgical Carpentier-Edwards bioprosthetic valve, viewed from the right atrium.


Asunto(s)
Bioprótesis , Anomalía de Ebstein , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
19.
J Cardiovasc Electrophysiol ; 27(6): 683-93, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27004444

RESUMEN

INTRODUCTION: Appropriate activated clotting time (ACT) during catheter ablation of atrial fibrillation (CA-AF) is essential to minimize periprocedural complications. METHODS AND RESULTS: An electronic search was performed using major databases. Outcomes were thromboembolic (TE) and bleeding complications according to ACT levels (seconds). Heparin dose (U/kg) and time (minutes) to achieve the target ACT was compared among patients receiving vitamin K antagonist (VKA) versus non-VKA oral anticoagulants (NOAC). Nineteen studies involving 7,150 patients were identified. Patients with ACT > 300 had less TE (OR, 0.51; 95% CI 0.35-0.74) and bleeding (OR, 0.70; 95% CI 0.60-0.83) compared to ACT < 300, when using any type of oral anticoagulation. The use of VKA was associated with reduced heparin requirements (mean dose: 157 U/kg vs. 209 U/kg, P < 0.03; SDM -0.86 [95% CI -1.39 to -0.33]), and with lower time to achieve the target ACT (mean time: 24 minutes vs. 49 minutes, P < 0.03; SDM -11.02 [95% CI -13.29 to -8.75]) compared to NOACs. No significant publication bias was found. CONCLUSIONS: Performing CA-AF with a target ACT > 300 decreases the risk of TE without increasing the risk of bleeding. Patients receiving VKAs required less heparin and reached the target ACT faster compared to NOACs.


Asunto(s)
Anticoagulantes/farmacocinética , Fibrilación Atrial/cirugía , Coagulación Sanguínea/efectos de los fármacos , Ablación por Catéter , Heparina/farmacocinética , Tromboembolia/prevención & control , Administración Oral , Anticoagulantes/administración & dosificación , Fibrilación Atrial/sangre , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Distribución de Chi-Cuadrado , Esquema de Medicación , Hemorragia/inducido químicamente , Heparina/administración & dosificación , Humanos , Oportunidad Relativa , Factores de Riesgo , Tromboembolia/etiología , Factores de Tiempo , Resultado del Tratamiento , Vitamina K/antagonistas & inhibidores
20.
Echocardiography ; 33(8): 1219-27, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27095475

RESUMEN

BACKGROUND: Transcranial Doppler (TCD) with agitated saline has been shown to be an alternative for the detection of right-to-left shunts (RLS) with similar diagnostic accuracies as transesophageal echocardiography (TEE). It is hypothesized that the addition of blood to agitated saline increases the sensitivity of TCD for the detection of RLS. The aim of this meta-analysis was to determine whether agitated saline with blood increases the sensitivity of TCD for the detection of RLS compared to agitated saline alone and other contrast agents. METHOD: A systematic review of Medline, Cochrane, and Embase was performed to look for all prospective studies assessing intracardiac RLS using TCD compared with TEE as the reference; both tests were performed with a contrast agent and a maneuver to provoke RLS in all studies. RESULTS: A total of 27 studies (29 comparisons) with 1,968 patients met the inclusion criteria. Of 29 comparisons, 10 (35%) used echovist contrast during TCD, 4 (14%) used a gelatin-based solution, 12 (41%) used agitated saline, and 3 (10%) utilized 2 different contrast agents. The addition of blood to agitated saline improved the sensitivity of TCD to 100% compared to agitated saline alone (96% sensitivity, P = 0.161), echovist (94% sensitivity, P = 0.044), and gelatin-based solutions (93% sensitivity, P = 0.041). CONCLUSION: The addition of blood to agitated saline improves the sensitivity of TCD for the detection of RLS to 100% when compared to other conventional contrast agents; these findings support the addition of blood to agitated saline during TCD bubble studies.


Asunto(s)
Análisis Químico de la Sangre , Foramen Oval Permeable/diagnóstico por imagen , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Cloruro de Sodio/química , Ultrasonografía Doppler Transcraneal/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste/administración & dosificación , Medios de Contraste/química , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Cloruro de Sodio/administración & dosificación , Ultrasonografía Doppler Transcraneal/efectos de los fármacos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA