Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 34(7): 4309-4320, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38148406

RESUMEN

OBJECTIVES: The purpose of this meta-analysis was to determine the diagnostic performance of conventional MRI and MR arthrography for tendinosis, and partial and complete tears of the long head of the biceps tendon (LHBT) using arthroscopy as the reference standard. MATERIALS AND METHODS: A systematic review was performed using predefined data fields in PubMed, and all articles published from January 2000 up to April 2022 were retrospectively pooled and reviewed. Six MRI studies on complete tear (n = 555) and ten studies on partial tear/tendinosis (n = 2487) were included in the analysis. Two of the included studies in each group investigated the use of MR arthrography. The data sets were analyzed using a univariate approach with the DerSimonian and Laird random effects model and the proportional hazards model. RESULTS: MRI shows high specificities in diagnosing complete tears of the LHBT ranging from 93.0 to 99.0%. Diagnostic sensitivity was more heterogeneous ranging from 55.9 to 90.0%. The overall negative likelihood ratio was 0.29 (95% CI: 0.17-0.50) and the overall positive likelihood ratio was 37.3 (95% CI: 11.9-117.4). The mean sensitivity in diagnosing partial tear/tendinosis of the LHBT was 67.8% (95% CI: 54.3-78.9%) and the specificity was 75.9% (95% CI: 63.6-85.0%), resulting in a balanced accuracy of 71.9%. The overall negative likelihood ratio was 0.44 (95% CI: 0.32-0.59) and the overall positive likelihood ratio was 2.64 (95% CI: 1.91-3.65). CONCLUSION: MRI is highly specific for the diagnosis of complete tears of the LHBT, whereas diagnostic sensitivity was more heterogeneous. The diagnosis of partial tears and/or tendinosis of the LHBT remains challenging on MRI, which may warrant complementary clinical examination or other imaging modalities to increase diagnostic confidence in equivocal cases. CLINICAL RELEVANCE STATEMENT: Conventional MRI and MR arthrography have high diagnostic performance for complete tendon tear when compared to arthroscopy. The diagnosis of tendinosis/partial tears remains challenging and may require comparison with clinical tests and other imaging modalities. KEY POINTS: •There is no clear consensus regarding the primary imaging modality for the evaluation of LHBT disorders. •Conventional MRI and MR arthrography are highly specific in diagnosing complete tears of the LHBT. •Diagnosis of partial tears/tendinosis of the LHBT on conventional MRI and MR arthrography remains a diagnostic challenge.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Traumatismos de los Tendones/diagnóstico por imagen , Tendinopatía/diagnóstico por imagen , Artroscopía
2.
Eur Radiol ; 34(3): 1556-1566, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37658140

RESUMEN

OBJECTIVE: Bioabsorbable magnesium-based alloy screws release gas upon resorption. The resulting findings in the adjacent soft tissues and joints may mimic infection. The aim of the study was to evaluate the ultrasound (US) findings in soft tissues and joints during screw resorption. METHODS: Prospectively acquired US studies from pediatric patients treated with magnesium screws were evaluated for screw head visibility, posterior acoustic shadowing, twinkling artifact, foreign body granuloma, gas (soft tissue, intra-articular), alterations of the skin and subcutaneous fat, perifascial fluid, localized fluid collections, hypervascularization, and joint effusion. RESULTS: Sixty-six US studies of 28 pediatric patients (nfemale = 9, nmale = 19) were included. The mean age of the patients at the time of surgery was 10.84 years; the mean time between surgery and ultrasound was 128.3 days (range = 6-468 days). The screw head and posterior acoustic shadowing were visible in 100% of the studies, twinkling artifact in 6.1%, foreign body granuloma in 92.4%, gas locules in soft tissue in 100% and intra-articular in 18.2%, hyperechogenicity of the subcutaneous fat in 90.9%, cobblestoning of the subcutaneous fat in 24.2%, loss of normal differentiation between the epidermis/dermis and the subcutaneous fat in 57.6%, localized fluid collection in 9.9%, perifascial fluid in 12.1%, hypervascularization in 27.3%, and joint effusion in 18.2%. CONCLUSION: US findings in pediatric patients treated with magnesium screws strongly resemble infection, but are normal findings in the setting of screw resorption. CLINICAL RELEVANCE STATEMENT: Bioabsorbable magnesium-based alloy screws release gas during resorption. The resulting US findings in the adjacent soft tissues and joints in pediatric patients may mimic infection, but are normal findings. KEY POINTS: • Bioabsorbable magnesium-based alloy screws release gas upon resorption. • The resulting ultrasound findings in children's soft tissues and joints closely resemble those of soft tissue infection or osteosynthesis-associated infection. • Be familiar with these ultrasound findings in order to avoid inadvertently misdiagnosing a soft tissue infection or osteosynthesis-associated infection.


Asunto(s)
Fracturas Óseas , Granuloma de Cuerpo Extraño , Infecciones de los Tejidos Blandos , Humanos , Masculino , Femenino , Niño , Magnesio , Implantes Absorbibles , Granuloma de Cuerpo Extraño/etiología , Infecciones de los Tejidos Blandos/etiología , Fracturas Óseas/etiología , Aleaciones , Fijación Interna de Fracturas/métodos , Tornillos Óseos/efectos adversos
3.
Eur Radiol ; 34(3): 1716-1723, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37644149

RESUMEN

OBJECTIVES: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. METHODS: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15-120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. RESULTS: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. CONCLUSION: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. CLINICAL RELEVANCE STATEMENT: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. KEY POINTS: • Noise is an important quantitative marker that strongly impacts image quality of PET images. • An automated computational noise measurement algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. • An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking as well as protocol harmonization.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía de Emisión de Positrones , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Hígado/diagnóstico por imagen , Algoritmos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fantasmas de Imagen
4.
BMC Pediatr ; 24(1): 315, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714956

RESUMEN

BACKGROUND: Ultrasound (US) is often the first method used to look for brain or cerebrospinal fluid (CSF) space pathologies. Knowledge of normal CSF width values is essential. Most of the available US normative values were established over 20 years ago, were obtained with older equipment, and cover only part of the age spectrum that can be examined by cranial US. This prospective study aimed to determine the normative values of the widths of the subarachnoid and internal CSF spaces (craniocortical, minimal and maximal interhemispheric, interventricular, and frontal horn) for high-resolution linear US probes in neurologically healthy infants and children aged 0-19 months and assess whether subdural fluid collections can be delineated. METHODS: Two radiologists measured the width of the CSF spaces with a conventional linear probe and an ultralight hockey-stick probe in neurologically healthy children not referred for cranial or spinal US. RESULTS: This study included 359 neurologically healthy children (nboys = 178, 49.6%; ngirls = 181, 50.4%) with a median age of 46.0 days and a range of 1-599 days. We constructed prediction plots, including the 5th, 50th, and 95th percentiles, and an interactive spreadsheet to calculate normative values for individual patients. The measurements of the two probes and the left and right sides did not differ, eliminating the need for separate normative values. No subdural fluid collection was detected. CONCLUSION: Normative values for the widths of the subarachnoid space and the internal CSF spaces are useful for evaluating intracranial pathology, especially when determining whether an increase in the subarachnoid space width is abnormal.


Asunto(s)
Espacio Subaracnoideo , Ultrasonografía , Humanos , Lactante , Estudios Prospectivos , Masculino , Femenino , Valores de Referencia , Recién Nacido , Ultrasonografía/métodos , Espacio Subaracnoideo/diagnóstico por imagen , Líquido Cefalorraquídeo/diagnóstico por imagen
5.
Eur Radiol ; 2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37855853

RESUMEN

OBJECTIVES: To assess the evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between years 2000 and 2021. METHODS: Pediatric patients (≤ 16 years) referred for 18F-FDG PET/CT or PET/MR imaging of the body during 2000 and 2021 were retrospectively included. The amount of administered radiotracer activity in megabecquerel (MBq) was recorded, and signal-to-noise ratio (SNR) was measured in the right liver lobe with a 4 cm3 volume of interest as an indicator for objective image quality. Descriptive statistics were computed. RESULTS: Two hundred forty-three children and adolescents underwent a total of 466 examinations. The median injected 18F-FDG activity in MBq decreased significantly from 296 MBq in 2000-2005 to 100 MBq in 2016-2021 (p < 0.001), equaling approximately one-third of the initial amount. The median SNR ratio was stable during all years with 11.7 (interquartile range [IQR] 10.7-12.9, p = 0.133). CONCLUSIONS: Children have benefited from a massive reduction in the administered 18F-FDG dose over the past 20 years without compromising objective image quality. CLINICAL RELEVANCE STATEMENT: Radiotracer dose was reduced considerably over the past two decades of pediatric F-18-fluorodeoxyglucose PET/CT and PET/MR imaging highlighting the success of technical innovations in pediatric PET imaging. KEY POINTS: • The evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between 2000 and 2021 was assessed. • The injected tracer activity decreased by 66% during the study period from 296 megabecquerel (MBq) to 100 MBq (p < 0.001). • The continuous implementation of technical innovations in pediatric hybrid 18F-FDG PET has led to a steady decrease in the amount of applied radiotracer, which is particularly beneficial for children who are more sensitive to radiation.

6.
Neuroradiology ; 65(4): 729-736, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36633612

RESUMEN

PURPOSE: To evaluate and compare which factors are relevant to the diagnostic decision-making and imaging workup of intracerebral hemorrhages in large, specialized European centers. METHODS: Expert neuroradiologists from ten large, specialized centers (where endovascular stroke treatment is routinely performed) in nine European countries were selected in cooperation with the European Society of Neuroradiology (ESNR). The experts were asked to describe how and when they would investigate specific causes in a patient who presented with an acute, atraumatic, intracerebral hemorrhage for two given locations: (1) basal ganglia, thalamus, pons or cerebellum; (2) lobar hemorrhage. Answers were collected, and decision trees were compared. RESULTS: Criteria that were considered relevant for decision-making reflect recommendations from current guidelines and were similar in all participating centers. CT Angiography or MR angiography was considered essential by the majority of centers regardless of other factors. Imaging in clinical practice tended to surpass guideline recommendations and was heterogeneous among different centers, e.g., in a scenario suggestive of typical hypertensive hemorrhage, recommendations ranged from no further follow-up imaging to CT angiography and MR angiography. In no case was a consensus above 60% achieved. CONCLUSION: In European clinical practices, existing guidelines for diagnostic imaging strategies in ICH evaluation are followed as a basis but in most cases, additional imaging investigation is undertaken. Significant differences in imaging workup were observed among the centers. Results suggest a high level of awareness and caution regarding potentially underlying pathology other than hypertensive disease.


Asunto(s)
Hemorragia Cerebral , Accidente Cerebrovascular , Humanos , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/patología , Accidente Cerebrovascular/terapia , Europa (Continente) , Tomografía Computarizada por Rayos X , Hospitales
7.
J Magn Reson Imaging ; 56(5): 1571-1579, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35106870

RESUMEN

BACKGROUND: Diagnosis of osteomyelitis by imaging can be challenging. The feasibility of diffusion-weighted imaging (DWI) as ancillary sequence was evaluated in this study. PURPOSE: To evaluate DWI for differentiation between osteomyelitis, bone marrow edema, and healthy bone on forefoot magnetic resonance imaging (MRI). STUDY TYPE: Prospective. SUBJECTS: A total of 60 consecutive patients undergoing forefoot MRI divided into three study groups (20 subjects each): osteomyelitis, bone marrow edema, and healthy bone. FIELD STRENGTH/SEQUENCE: A 1.5T and 3T MRI scanners; readout-segmented multishot echo planar DWI. ASSESSMENT: Two independent radiologists measured apparent diffusion coefficient (ADC) values within abnormal or healthy bone. STATISTICAL TESTS: ADC values were compared between groups (pairwise t-test with Bonferroni-Holm correction for multiple testing). Intraclass correlation coefficient (ICC) was calculated to assess inter-reader agreement. Threshold ADC values were determined as the cutoffs that maximized the sum of sensitivity and specificity. Receiver operating characteristic (ROC) analysis was performed with statistical threshold of P < 0.05. RESULTS: Inter-reader agreement was 0.92 in the healthy bone group and 0.78 in both the edema and osteomyelitis groups. Average ADC values were significantly different between groups: 1432 ± 222 × 10-6  mm2 /sec (osteomyelitis), 1071 ± 196 × 10-6  mm2 /sec (bone marrow edema), and 277 ± 89 × 10-6  mm2 /sec (healthy bone). A threshold ADC value of 534 × 10-6  mm2 /sec distinguishes between healthy and abnormal bone with specificity and sensitivity of 100% each. For distinction between osteomyelitis and bone marrow edema, two cutoff values were determined: a 95%-specificity cutoff indicating osteomyelitis (>1320 × 10-6  mm2 /sec) and a 95%-sensitivity cutoff indicating bone marrow edema (<1155 × 10-6  mm2 /sec). Diagnostic accuracy of 95% was achieved for 73% (29/40) of the subjects. DATA CONCLUSION: DWI with ADC maps distinguishes between healthy and abnormal bone on forefoot MRI. Calculated cutoff values allow confirmation or exclusion of osteomyelitis in a high proportion of subjects. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Enfermedades de la Médula Ósea , Osteomielitis , Médula Ósea/diagnóstico por imagen , Médula Ósea/patología , Enfermedades de la Médula Ósea/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Edema/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Osteomielitis/diagnóstico por imagen , Estudios Prospectivos , Sensibilidad y Especificidad
8.
BMC Pediatr ; 22(1): 584, 2022 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-36209062

RESUMEN

BACKGROUND: The size of the anterior visual pathway (AVP) structures is affected by patient age and pathology. Normative data is useful when determining whether pathology is present. AVP structures do not respect the standard planes of magnetic resonance (MR) imaging. The aim of this study was to produce normative age-related and axis-corrected data of the AVP structures using multiplanar reformation (MPR) of high-resolution 3D T2-weighted fast spin echo (3D T2w FSE) images. METHODS: For each patient 32 measurements of AVP structures were obtained in 145 children (2 months - 18 years) with normal brain MR studies on high-resolution 3D T2w FSE images adjusted to the axis of each AVP structure. Descriptive statistics were calculated for different age classes and growth models were fitted to the data and assessed for their performance to create a formal statistical model that allows inference beyond the sample. RESULTS: Descriptive statistics were compiled in a reference table and prediction plots in relation to age, height, and body surface area (BSA) were obtained from the best overall performing statistical model, also taking field strength (1.5 vs. 3 T) into account. Intraclass correlation coefficient values were calculated for all variables ranging from 0.474 to 0.967, the most reliable being the transverse diameter of the globe, the maximum diameter of the retrobulbar nerve sheath, the intracranial segment of the optic nerve and the transverse diameter of the chiasm. The maximum retrobulbar diameter of the optic nerve sheath and the lateral superoinferior diameter of the chiasm showed no statistically significant change with age. CONCLUSION: Detailed charts of reference values for AVP structures as well as prediction plots in relation to age, height and BSA were established using axis-corrected measurements from the MPR of high-resolution 3D T2w FSE images. Furthermore, an Excel spreadsheet that allows users to calculate normative values for the 9 AVP structures of key interest is provided as supplementary material.


Asunto(s)
Imagenología Tridimensional , Vías Visuales , Niño , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Modelos Estadísticos , Valores de Referencia , Vías Visuales/diagnóstico por imagen
9.
Pediatr Radiol ; 52(12): 2368-2376, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35606529

RESUMEN

BACKGROUND: Resorption of magnesium-based alloy bioabsorbable screws produces hydrogen gas, which can be mistaken as a sign of infection and may affect the physis or fixed bone fragment. OBJECTIVE: We evaluated the temporal and spatial occurrence of gas and the occurrence of a breakage of the fixed bone fragment or screw following magnesium screw fixation. MATERIALS AND METHODS: Radiographs of paediatric patients treated with magnesium screws were retrospectively reviewed. Temporal occurrence and distribution of gas in the bone, the physis and soft tissues, breakage of the screw or fixed bone fragment and joint effusion were assessed. RESULTS: One hundred and three radiographs in 35 paediatric patients were reviewed (mean age: 10.6 years). Follow-up ranged from 1 to 730 days. Gas in the bone increases up to week 5, remains constant up to week 16 and then decreases. Gas in soft tissues, intra-articular gas and joint effusions gradually reduce over time. In 1/23 (4.3%) patients with an open physis, gas intrusion into the physis occurred. Breakage of the bone fragment fixated by the screw was observed in 4/35 (11.4%) patients within the first 6 weeks. Screw breakage was observed in 16/35 (45.7%) patients, with a median time to first detection of 300 days. CONCLUSION: Gas bubbles in bone and soft tissue are normal findings in the context of screw resorption and should not be confused with soft-tissue infection or osteomyelitis. Gas is rarely visible in the physis. Breakage of the fixed bone fragment and/or screw can occur.


Asunto(s)
Fracturas Óseas , Magnesio , Humanos , Niño , Implantes Absorbibles , Estudios Retrospectivos , Tornillos Óseos , Aleaciones , Fracturas Óseas/etiología
10.
Pediatr Radiol ; 52(13): 2584-2594, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35836016

RESUMEN

BACKGROUND: Exposure of the eye lens to ionizing radiation results in cataract. Several dose optimization techniques to protect the lens are available for computed tomography (CT). OBJECTIVE: The radiation dose to the eye lens, volume CT dose index (CTDIvol) and image quality of various methods of dose optimization were evaluated for pediatric head CT: automated tube current modulation (ATCM), automated tube voltage selection (ATVS), organ-based tube current modulation (OBTCM) and bismuth shielding. MATERIALS AND METHODS: An anthropomorphic phantom of a 5-year-old child was scanned with nine protocols: no dose optimization technique and then adding different dose optimization techniques alone and in combination. Dose to the eye, thyroid and breast were estimated using metal oxide semiconductor field effect transistor (MOSFET) dosimetry. CTDIvol, influence of timing of shield placement, image noise and attenuation values in 13 regions of interest of the head and subjective image quality were compared. RESULTS: The eye shield significantly reduced the eye lens dose when used alone, to a similar degree as when using all software-based techniques together. When used in combination with software-based techniques, the shield reduced the eye lens dose by up to 45% compared to the no dose optimization technique. Noise was significantly increased by the shield, most pronounced in the anterior portion of the eye. CONCLUSION: The combination of ATCM, ATVS, OBTCM and a bismuth shield, with the shield placed after acquiring the localizer image, should be considered to reduce the radiation dose to the eye lens in pediatric head CT.


Asunto(s)
Bismuto , Protección Radiológica , Niño , Humanos , Preescolar , Dosis de Radiación , Protección Radiológica/métodos , Cabeza/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen
11.
Skeletal Radiol ; 51(3): 573-579, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34255126

RESUMEN

OBJECTIVE: Short tau or short TI inversion recovery (STIR) MRI sequences are considered a robust fat suppression technique. However, STIR also suppresses signals from other tissues with similar T1 relaxation times. This study investigates the in vivo effect of intravenous gadolinium-based T1-shortening contrast agent on STIR signal. MATERIALS AND METHODS: Institutional board approval and informed consent was obtained. MRI examinations (1.5-T or 3-T) of 31 prospectively included patients were analyzed by two readers. Signal intensity of degenerative bone marrow edema-like signal at the Lisfranc joint on precontrast STIR images and on STIR images acquired after intravenous contrast agent administration (gadoteric acid, gadolinium: 0.5 mmol/ml, 15 ml) was measured. The medial cuneiform bone without observable bone marrow edema-like signal was considered a healthy tissue and served as a reference. Relative changes in signal intensity between precontrast and postcontrast images were calculated for the two tissues. Wilcoxon signed-rank test served for statistical analyses. RESULTS: In bone marrow edema-like signal, both readers observed a median signal change of -35% (interquartile range (IQR) 24) and -34% (IQR 21), respectively, on postcontrast STIR images compared to precontrast STIR. In healthy tissue, the signal remained constant on postcontrast STIR images (median change -2%, IQR 15, and 0%, IQR 17) respectively. For both readers, postcontrast signal change in bone marrow edema-like signal differed from that in healthy tissue (p < 0.001). CONCLUSION: Intravenous gadolinium-based contrast agent causes a significant reduction of signal intensity in bone marrow edema-like signal on routine STIR images. Thus, pathological MRI findings may be obscured.


Asunto(s)
Enfermedades de la Médula Ósea , Medios de Contraste , Médula Ósea/diagnóstico por imagen , Enfermedades de la Médula Ósea/inducido químicamente , Enfermedades de la Médula Ósea/diagnóstico por imagen , Edema/inducido químicamente , Edema/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
12.
BMC Pediatr ; 21(1): 276, 2021 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-34116649

RESUMEN

BACKGROUND: Organ size is influenced by a number of factors. Age, height, weight, and ethnicity are known influencing factors. Pediatric populations have changed over time, puberty beginning earlier resulting in a changing growth pattern of their organs. Hence, contemporary charts using local data are considered the most appropriate for a given population. Sonographic charts for liver size for a predominantly Caucasian population are limited, which has implications for clinical practice. The aim of this study was to define a contemporary normative range of liver and spleen sizes for a healthy, predominantly Caucasian population and for all pediatric age groups (0-18 years) and to investigate whether there is a size difference between genders and ethnicities. METHODS: Retrospective study including children with normal sonographic findings and no evidence of liver or splenic disease clinically. Craniocaudal and anteroposterior dimensions are measured for the right and left lobe of the liver, and craniocaudal dimension for the spleen. Relationship of the liver and spleen dimensions with age, body length, body surface area, weight, and gender were investigated. Charts of normal values were established. Values were compared to studies involving other ethnicities and to one study carried out in 1983 involving the same ethnicity. RESULTS: Seven hundred thirty-six children (371 boys, 365 girls) aged 1 day - 18.4 years were included. From the second year of life, the craniocaudal dimension of the right lobe of the liver is 1-2 cm larger in the Central European population compared with non-Caucasian populations at a given age. Liver size of Central European children in 2020 is greater compared to a similar population almost 40 years ago. The craniocaudal dimension of the spleen of Central European, US-American and Turkish children is similar. The difference between genders is statistically significant for both the liver and the spleen, being larger in boys. CONCLUSION: Contemporary and ethnically appropriate reference charts for liver and spleen measurements should be used, especially for liver size. The effect of ethnicity is reduced if patient height rather than age is referenced.


Asunto(s)
Hígado , Bazo , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Hígado/diagnóstico por imagen , Masculino , Tamaño de los Órganos , Valores de Referencia , Estudios Retrospectivos , Bazo/diagnóstico por imagen , Ultrasonografía
13.
Pediatr Radiol ; 48(4): 586-593, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29362838

RESUMEN

BACKGROUND: Bleeding, ulceration and cardiac failure can occur in rapidly involuting congenital hemangioma (RICH). Bleeding intensity ranges from superficial to life-threatening. OBJECTIVE: To determine whether there are sonographic criteria associated with an increased risk of bleeding, ulceration or cardiac failure in RICH in order to identify children who need close monitoring or prophylactic treatment. MATERIALS AND METHODS: This retrospective single-center study included RICH patients over a period of 13 years. We evaluated sonographic features of RICH on B-mode and Doppler ultrasound. We correlated the occurrence of bleeding, ulceration and cardiac failure with four sonographic findings: (1) visible vessel, (2) venous ectasia, (3) venous lake and (4) arteriovenous shunting. RESULTS: We included 24 patients. Ulceration occurred in five cases, bleeding in four cases, one of which was life-threatening. Cardiac failure was observed more frequently in RICH with venous lakes (P=0.028). Bleeding and ulceration appeared more frequently in RICH with venous ectasia and venous lakes. Cardiac failure was associated with the presence of venous ectasia. All children with cardiac failure or ulceration had arteriovenous shunts. CONCLUSION: RICH with venous lakes on ultrasound is prone to develop bleeding, cardiac failure and ulceration. This association was only significant for cardiac failure.


Asunto(s)
Insuficiencia Cardíaca/etiología , Hemangioma/congénito , Hemangioma/diagnóstico por imagen , Hemorragia/etiología , Úlcera Cutánea/etiología , Ultrasonografía/métodos , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos
14.
Pediatr Radiol ; 47(13): 1766-1775, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28884206

RESUMEN

BACKGROUND: The differential diagnosis for primary lung masses in neonates includes a variety of developmental abnormalities; it also consists of the much rarer congenital primary lung tumors: cystic pleuropulmonary blastoma (cystic PPB), fetal lung interstitial tumor (FLIT), congenital peribronchial myofibroblastic tumor (CPMT), and congenital fibrosarcoma. Radiologic differentiation between malformations and tumors is often very challenging. OBJECTIVE: The objective was to establish distinctive features between developmental pulmonary abnormalities and primary lung tumors. MATERIALS AND METHODS: We conducted a retrospective study of 135 congenital lung lesions at a university mother and child center over a period of 10 years (2005-2015). During this time, we noted four tumors (two cystic PPBs and two FLITs) and 131 malformations. We recorded the following parameters: timing of conspicuity in utero (mid-second trimester, third trimester, or not seen prenatally), presence of symptoms at birth, prenatal and perinatal radiologic findings, and either histological diagnoses by pathology or follow-up imaging in non-operated cases. RESULTS: All lesions except the four tumors were detected during mid-second-trimester ultrasound. In none of the tumors was any pulmonary abnormality found on the mid-second-trimester sonogram, contrary to the developmental pulmonary abnormalities. CONCLUSION: The timing of conspicuity in utero appears to be a key feature for the differentiation between malformations and tumors. Lesions that were not visible at the mid-second-trimester ultrasound should be considered as tumor. A cystic lung lesion in the context of a normal mid-second-trimester ultrasound is highly suggestive of a cystic PPB. Differentiating the types of solid congenital lung tumors based upon imaging features is not yet feasible.


Asunto(s)
Neoplasias Pulmonares/congénito , Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/anomalías , Blastoma Pulmonar/congénito , Blastoma Pulmonar/diagnóstico por imagen , Ultrasonografía Prenatal , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Recién Nacido , Masculino , Embarazo , Segundo Trimestre del Embarazo , Estudios Retrospectivos
15.
AJR Am J Roentgenol ; 206(4): 740-6, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26866340

RESUMEN

OBJECTIVE: The objective of this study was to systematically evaluate the accuracy of abdominal CT performed at different radiation dose levels for the detection of body packs in human cadavers, in comparison with the accuracy of abdominal radiography. MATERIALS AND METHODS: In this study, differing numbers of body packs (range, 0-20) were placed in the alimentary tract of human cadavers and then underwent imaging with abdominal radiography and with CT performed at different radiation dose levels (ranging from the standard abdominal CT dose to the technical minimum dose). Depiction of body packs on abdominal radiographs and on each CT scan was assessed by two independent blinded radiologists, and the accuracy of detection of body packs was calculated. The radiation dose associated with abdominal radiography was measured, and the effective radiation dose associated with CT was estimated. RESULTS: The mean (± SD) effective radiation dose for abdominal radiography was 1.4 ± 0.3 mSv, whereas the mean effective dose of CT ranged from 0.1 to 9.6 mSv. Interobserver agreement for body pack detection was moderate (κ = 0.51) for abdominal radiography and good (κ = 0.72-0.85) for CT. In a per-body pack analysis, abdominal radiography depicted 42% of the body packs with a sensitivity of 71% and a specificity of 100%. When performed at radiation dose levels of 0.6 mSv or greater, CT correctly detected all body packs. In per-person analysis, the sensitivity and specificity of CT for the correct detection of at least one body pack per cadaver was 100% for all radiation dose levels. CONCLUSION: CT performed at a dose of 0.6 mSv can be used for the detection of body packs. With a sensitivity and specificity of 100%, CT is superior to abdominal radiography in terms of reliability, associated radiation dose, and accuracy of detection.


Asunto(s)
Cuerpos Extraños/diagnóstico por imagen , Dosis de Radiación , Radiografía Abdominal/métodos , Detección de Abuso de Sustancias/métodos , Tomografía Computarizada por Rayos X/métodos , Cadáver , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Insights Imaging ; 15(1): 140, 2024 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-38853223

RESUMEN

PURPOSE: To systematically analyse the time course of vessel wall enhancement and associated stenosis in patients with primary angiitis of the central nervous system (PACNS) following immunosuppressive therapy. MATERIAL AND METHODS: Two neuroradiologists retrospectively analysed MRIs of patients with PACNS seen at the Bern University Hospital and the St. Gallen Cantonal Hospital between 2015 and 2020. MRIs were examined for the presence of vessel wall enhancement, length of vessel wall enhancement (mm), circumferential extent of enhancement (degree) and degree of stenosis (%). Descriptive statistics and measurements of interobserver reliability were obtained. To investigate the temporal profiles of the variables following the commencement of immunosuppressant treatment, four series of Bayesian generalised multi-level models were generated. RESULTS: A total of 23 patients with 43 affected vessels identified from 209 MRI exams were evaluated (mean follow-up: 715 days, standard deviation ± 487 days), leading to a complete dataset of 402 entries. Vessel wall enhancement and circumferential extent of enhancement decreased for approximately 1 year after the initiation of immunosuppressant therapy. Changes were more pronounced in younger patients. Disappearance of vessel wall enhancement (in at least one vessel) was seen in about half of patients after a median of 172 days interquartile range 113-244, minimum 54 days, maximum 627 days. CONCLUSIONS: This study evaluated the typical time course of vessel wall enhancement in patients with PACNS. Our results could be a useful reference for radiologists and clinicians interpreting follow-up imaging in patients with PACNS. CRITICAL RELEVANCE STATEMENT: Routine clinical exams can be interpreted with more confidence when radiologists are aware of the typical temporal evolution of vessel wall enhancement in patients with primary angiitis of the central nervous system after initiation of immunosuppressive therapy. KEY POINTS: Few data exist for vessel wall imaging of primary angiitis of the central nervous system. Following immunosuppressant therapy, vessel wall enhancement decreases for approximately one year. These results may serve as a reference for radiologists performing follow-up imaging.

17.
J Clin Med ; 12(8)2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37109351

RESUMEN

BACKGROUND: The resorption of magnesium-based alloy bioabsorbable screws results in the release of hydrogen gas, which can mimic infection and enter the growth plate. The screw itself and the released gas may also affect image quality. OBJECTIVE: The evaluation of magnetic resonance imaging (MRI) findings during the most active phase of screw resorption is the objective, with particular focus on the growth plate and to assess for the presence of metal-induced artifacts. MATERIAL AND METHODS: In total, 30 prospectively acquired MRIs from 17 pediatric patients with fractures treated with magnesium screws were assessed for the presence and distribution of intraosseous, extraosseous, and intra-articular gas; gas within the growth plate; osteolysis along the screw; joint effusion; bone marrow edema; periosteal reaction; soft tissue edema; and metal-induced artifacts. RESULTS: Gas locules were found in the bone and soft tissues in 100% of the examinations, intra-articular in 40%, and in 37% of unfused growth plates. Osteolysis and the periosteal reaction were present in 87%, bone marrow edema in 100%, soft tissue edema in 100%, and joint effusion in 50% of examinations. Pile-up artifacts were present in 100%, and geometric distortion in 0% of examinations. Fat suppression was not significantly impaired in any examination. CONCLUSIONS: Gas and edema in the bone and soft tissues are normal findings during the resorption of magnesium screws and should not be misinterpreted as infection. Gas can also be detected within growth plates. MRI examinations can be performed without metal artifact reduction sequences. Standard fat suppression techniques are not significantly affected.

18.
Br J Radiol ; 96(1152): 20220482, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37751216

RESUMEN

OBJECTIVES: To evaluate the evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET/CT between 2007 and 2021. METHODS AND MATERIALS: Data from all pediatric patients aged 0-18 years who underwent hybrid 2-[18F]FDG PET/CT of the body between January 2007 and May 2021 were reviewed. Demographic and imaging parameters were collected. A board-certified radiologist reviewed all CT scans and measured image noise in the brain, liver, and adductor muscles. RESULTS: 294 scans from 167 children (72 females (43%); median age: 14 (IQR 10-15) years; BMI: median 17.5 (IQR 15-20.4) kg/m2) were included. CT dose index-volume (CTDIvol) and dose length product (DLP) both decreased significantly from 2007 to 2021 (both p < 0.001, Spearman's rho coefficients -0.46 and -0.35, respectively). Specifically, from 2007 to 2009 to 2019-2021 CTDIvol and DLP decreased from 2.94 (2.14-2.99) mGy and 309 (230-371) mGy*cm, respectively, to 0.855 (0.568-1.11) mGy and 108 (65.6-207) mGy*cm, respectively. From 2007 to 2021, image noise in the brain and liver remained constant (p = 0.26 and p = 0.06), while it decreased in the adductor muscles (p = 0.007). Peak tube voltage selection (in kilovolt, kV) of CT scans shifted from high kV imaging (140 or 120kVp) to low kV imaging (100 or 80kVp) (p < 0.001) from 2007 to 2021. CONCLUSION: CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT has decreased in recent years equaling approximately one-third of the initial amount. ADVANCES IN KNOWLEDGE: Over the past 15 years, CT radiation dose decreased considerably in pediatric patients undergoing hybrid imaging, while objective image quality may not have been compromised.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Femenino , Humanos , Niño , Adolescente , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Encéfalo
19.
Sci Rep ; 13(1): 11332, 2023 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-37443158

RESUMEN

To evaluate whether a machine learning classifier can evaluate image quality of maximum intensity projection (MIP) images from F18-FDG-PET scans. A total of 400 MIP images from F18-FDG-PET with simulated decreasing acquisition time (120 s, 90 s, 60 s, 30 s and 15 s per bed-position) using block sequential regularized expectation maximization (BSREM) with a beta-value of 450 and 600 were created. A machine learning classifier was fed with 283 images rated "sufficient image quality" and 117 images rated "insufficient image quality". The classification performance of the machine learning classifier was assessed by calculating sensitivity, specificity, and area under the receiver operating characteristics curve (AUC) using reader-based classification as the target. Classification performance of the machine learning classifier was AUC 0.978 for BSREM beta 450 and 0.967 for BSREM beta 600. The algorithm showed a sensitivity of 89% and 94% and a specificity of 94% and 94% for the reconstruction BSREM 450 and 600, respectively. Automated assessment of image quality from F18-FDG-PET images using a machine learning classifier provides equivalent performance to manual assessment by experienced radiologists.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Redes Neurales de la Computación , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
20.
Sci Rep ; 13(1): 18357, 2023 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-37884535

RESUMEN

This study aimed to evaluate the diagnostic accuracy of Node Reporting and Data System (Node-RADS) in discriminating between normal, reactive, and metastatic axillary LNs in patients with melanoma who underwent SARS-CoV-2 vaccination. Patients with proven melanoma who underwent a 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (2-[18F]-FDG PET/CT) between February and April 2021 were included in this retrospective study. Primary melanoma site, vaccination status, injection site, and 2-[18F]-FDG PET/CT were used to classify axillary LNs into normal, inflammatory, and metastatic (combined classification). An adapted Node-RADS classification (A-Node-RADS) was generated based on LN anatomical characteristics on low-dose CT images and compared to the combined classification. 108 patients were included in the study (54 vaccinated). HALNs were detected in 42 patients (32.8%), of whom 97.6% were vaccinated. 172 LNs were classified as normal, 30 as inflammatory, and 14 as metastatic using the combined classification. 152, 22, 29, 12, and 1 LNs were classified A-Node-RADS 1, 2, 3, 4, and 5, respectively. Hence, 174, 29, and 13 LNs were deemed benign, equivocal, and metastatic. The concordance between the classifications was very good (Cohen's k: 0.91, CI 0.86-0.95; p-value < 0.0001). A-Node-RADS can assist the classification of axillary LNs in melanoma patients who underwent 2-[18F]-FDG PET/CT and SARS-CoV-2 vaccination.


Asunto(s)
COVID-19 , Melanoma , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Vacunas contra la COVID-19 , SARS-CoV-2 , Fluorodesoxiglucosa F18 , Estudios Retrospectivos , Estadificación de Neoplasias , Metástasis Linfática/patología , COVID-19/diagnóstico por imagen , COVID-19/patología , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Melanoma/diagnóstico por imagen , Melanoma/patología , Vacunación , Radiofármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA