Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 87(6): 2885-2900, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35142398

RESUMEN

PURPOSE: Develop a deflectable intracardiac MR imaging (ICMRI) guiding-sheath to accelerate imaging during MR-guided electrophysiological (EP) interventions for radiofrequency (500 kHz) ablation (RFA) of arrythmia. Requirements include imaging at three to five times surface-coil SNR in cardiac chambers, vascular insertion, steerable-active-navigation into cardiac chambers, operation with ablation catheters, and safe levels of MR-induced heating. METHODS: ICMRI's 6 mm outer-diameter (OD) metallic-braided shaft had a 2.6 mm OD internal lumen for ablation-catheter insertion. Miniature-Baluns (MBaluns) on ICMRI's 1 m shaft reduced body-coil-induced heating. Distal section was a folded "star"-shaped imaging-coil mounted on an expandable frame, with an integrated miniature low-noise-amplifier overcoming cable losses. A handle-activated movable-shaft expanded imaging-coil to 35 mm OD for imaging within cardiac-chambers. Four MR-tracking micro-coils enabled navigation and motion-compensation, assuming a tetrahedron-shape when expanded. A second handle-lever enabled distal-tip deflection. ICMRI with a protruding deflectable EP catheter were used for MR-tracked navigation and RFA using a dedicated 3D-slicer user-interface. ICMRI was tested at 3T and 1.5T in swine to evaluate (a) heating, (b) cardiac-chamber access, (c) imaging field-of-view and SNR, and (d) intraprocedural RFA lesion monitoring. RESULTS: The 3T and 1.5T imaging SNR demonstrated >400% SNR boost over a 4 × 4 × 4 cm3 FOV in the heart, relative to body and spine arrays. ICMRI with MBaluns met ASTM/IEC heating limits during navigation. Tip-deflection allowed navigating ICMRI and EP catheter into atria and ventricles. Acute-lesion long-inversion-time-T1-weighted 3D-imaging (TWILITE) ablation-monitoring using ICMRI required 5:30 min, half the time needed with surface arrays alone. CONCLUSION: ICMRI assisted EP-catheter navigation to difficult targets and accelerated RFA monitoring.


Asunto(s)
Ablación por Catéter , Imagen por Resonancia Magnética , Animales , Arritmias Cardíacas , Ablación por Catéter/métodos , Diseño de Equipo , Atrios Cardíacos , Imagen por Resonancia Magnética/métodos , Porcinos
2.
Magn Reson Med ; 84(3): 1661-1671, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32077521

RESUMEN

PURPOSE: Motion artifact limits the clinical translation of high-field MR. We present an optical prospective motion correction system for 7 Tesla MRI using a custom-built, within-coil camera to track an optical marker mounted on a subject. METHODS: The camera was constructed to fit between the transmit-receive coils with direct line of sight to a forehead-mounted marker, improving upon prior mouthpiece work at 7 Tesla MRI. We validated the system by acquiring a 3D-IR-FSPGR on a phantom with deliberate motion applied. The same 3D-IR-FSPGR and a 2D gradient echo were then acquired on 7 volunteers, with/without deliberate motion and with/without motion correction. Three neuroradiologists blindly assessed image quality. In 1 subject, an ultrahigh-resolution 2D gradient echo with 4 averages was acquired with motion correction. Four single-average acquisitions were then acquired serially, with the subject allowed to move between acquisitions. A fifth single-average 2D gradient echo was acquired following subject removal and reentry. RESULTS: In both the phantom and human subjects, deliberate and involuntary motion were well corrected. Despite marked levels of motion, high-quality images were produced without spurious artifacts. The quantitative ratings confirmed significant improvements in image quality in the absence and presence of deliberate motion across both acquisitions (P < .001). The system enabled ultrahigh-resolution visualization of the hippocampus during a long scan and robust alignment of serially acquired scans with interspersed movement. CONCLUSION: We demonstrate the use of a within-coil camera to perform optical prospective motion correction and ultrahigh-resolution imaging at 7 Tesla MRI. The setup does not require a mouthpiece, which could improve accessibility of motion correction during 7 Tesla MRI exams.


Asunto(s)
Artefactos , Encéfalo , Encéfalo/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Movimiento (Física) , Neuroimagen , Estudios Prospectivos
3.
Magn Reson Med ; 81(2): 1434-1446, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30260501

RESUMEN

PURPOSE: An "RF-penetrable" PET insert that allows the MR body coil to be used for RF transmission was developed to make it easier for an existing MR center to achieve simultaneous PET/MRI. This study focuses on experiments and analyses to study PET/RF coil configurations for simultaneous PET/MR studies. METHODS: To investigate the appropriate RF coil design, a transmit/receive (TX/RX) birdcage coil and an RX-only phased-array coil (TX from body coil), both fitting inside the PET ring were built and characterized. For MR performance evaluation, B1 field uniformity and MR image SNR were calculated. PET photon attenuation due to each coil was studied by means of CT-based attenuation maps and reconstructed PET images. RESULTS: When using the RX-only phased-array coil (TX from body coil), compared with the TX/RX birdcage coil, the B1 field uniformity and the MR image (gradient echo and fast spin echo) SNR increased by 2.4±4.8%, 386.1±62.3%, and 205.0±56.5%, respectively. Although some components of the coil were distributed within the PET FOV, no significant PET photon attenuation was shown in the CT-based attenuation map and reconstructed PET images. CONCLUSION: RF coil configurations for an RF-penetrable PET insert for simultaneous PET/MRI were studied. The RX-only phased-array coil (TX from body coil) outperformed the TX/RX birdcage coil with improved MR performance as well as negligible PET photon attenuation.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/instrumentación , Tomografía de Emisión de Positrones/instrumentación , Ondas de Radio , Diseño de Equipo , Humanos , Imagen Multimodal/instrumentación , Fantasmas de Imagen , Fotones , Reproducibilidad de los Resultados , Relación Señal-Ruido
4.
Magn Reson Med ; 79(3): 1745-1752, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28585334

RESUMEN

PURPOSE: Magnetic resonance-compatible medical devices operate within the MR environment while benefitting from the superior anatomic information of MRI. Avoiding electromagnetic interference between such instrumentation and the MR system is crucial. In this work, various shielding configurations for positron emission tomography (PET) detectors were studied and analyzed regarding radiofrequency (RF) shielding effectiveness and gradient-induced eddy current performances. However, the results of this work apply to shielding considerations for any MR-compatible devices. METHODS: Six shielding enclosure configurations with various thicknesses, patterns, and materials were designed: solid and segmented copper, phosphor bronze mesh (PBM), and carbon fiber composite (CFC). A series of tests was performed on RF shielding effectiveness and the gradient-induced eddy current. RESULTS: For the shielding effectiveness, the solid copper with various thickness and PBM configurations yield significantly better shielding effectiveness (>15 dB) compared with CFC and segmented configurations. For the gradient-induced eddy current performance, the solid copper shielding configurations with different thicknesses showed significantly worse results, up to a factor of 3.89 dB, compared with the segmented copper, PBM, and the CFC configurations. CONCLUSIONS: We evaluated the RF shielding effectiveness and the gradient-induced eddy current artifacts of several shielding designs, and only the PBM showed positive outcomes for both aspects. Magn Reson Med 79:1745-1752, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Cobre/química , Diseño de Equipo , Humanos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos , Ondas de Radio
5.
Artículo en Inglés | MEDLINE | ID: mdl-30613196

RESUMEN

PURPOSE: To identify novel concepts for RF-shim loop architectures suitable for 7T made of two concentric conducting loops fulfilling RF and DC functions, respectively, and to determine their relative SNR performance. The goal is to minimize interference between the two systems while making efficient use of the space closest to the body. THEORY: We show by means of theoretical derivation of the frequency spectrum that the proposed two-loop structure exhibits an anti-resonant null and a resonant peak in the frequency domain. METHODS: The proposed structure is comprised of two concentric wire loops either arranged as nested loops or in the form of a coaxial cable, in which the two conductors carry the RF and shim signals, respectively. We use theory, simulation, and phantom measurements to obtain frequency spectra and SNR maps for the proposed structures. RESULTS: Retained SNR is found to be 75% in the coaxial loop and ranges from 57% to 67% in three different coaxial configurations. We have found both implementations to be a viable concept for the use in RF-shim devices if remaining SNR limitations can be overcome. CONCLUSIONS: We have investigated two new design modalities in 7T RF-shim coil design that separate the RF and shim conductors such that the previously proposed toroidal chokes are eliminated - thereby removing undesired additional loss, bulk, and design complexity.

6.
Magn Reson Med ; 75(5): 2204-16, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26101951

RESUMEN

PURPOSE: To restore 12-lead electrocardiographic (ECG) signal fidelity inside MRI by removing magnetic field gradient-induced voltages during high gradient duty cycle sequences. THEORY AND METHODS: A theoretical equation was derived to provide first- and second-order electrical fields induced at individual ECG electrodes as a function of gradient fields. Experiments were performed at 3T on healthy volunteers using a customized acquisition system that captured the full amplitude and frequency response of ECGs, or a commercial recording system. The 19 equation coefficients were derived via linear regression of data from accelerated sequences and were used to compute induced voltages in real-time during full resolution sequences to remove ECG artifacts. Restored traces were evaluated relative to ones acquired without imaging. RESULTS: Measured induced voltages were 0.7 V peak-to-peak during balanced steady state free precession (bSSFP) with the heart at the isocenter. Applying the equation during gradient echo sequencing, three-dimensional fast spin echo, and multislice bSSFP imaging restored nonsaturated traces and second-order concomitant terms showed larger contributions in electrodes further from the magnet isocenter. Equation coefficients are evaluated with high repeatability (ρ = 0.996) and are dependent on subject, sequence, and slice orientation. CONCLUSION: Close agreement between theoretical and measured gradient-induced voltages allowed for real-time removal. Prospective estimation of sequence periods in which large induced voltages occur may allow hardware removal of these signals.


Asunto(s)
Electrocardiografía , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Adulto , Algoritmos , Artefactos , Técnicas de Imagen Sincronizada Cardíacas , Electrodos , Voluntarios Sanos , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Reproducibilidad de los Resultados
7.
Magn Reson Med ; 71(3): 1197-209, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23580479

RESUMEN

PURPOSE: Voltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological cardiac-arrhythmia therapy. During electrophysiological procedures, electro-anatomic mapping workstations provide guidance by integrating VDT location and intracardiac electrocardiogram information with X-ray, computerized tomography, ultrasound, and MR images. MR assists navigation, mapping, and radiofrequency ablation. Multimodality interventions require multiple patient transfers between an MRI and the X-ray/ultrasound electrophysiological suite, increasing the likelihood of patient-motion and image misregistration. An MRI-compatible VDT system may increase efficiency, as there is currently no single method to track devices both inside and outside the MRI scanner. METHODS: An MRI-compatible VDT system was constructed by modifying a commercial system. Hardware was added to reduce MRI gradient-ramp and radiofrequency unblanking pulse interference. VDT patches and cables were modified to reduce heating. Five swine cardiac VDT electro-anatomic mapping interventions were performed, navigating inside and thereafter outside the MRI. RESULTS: Three-catheter VDT interventions were performed at >12 frames per second both inside and outside the MRI scanner with <3 mm error. Catheters were followed on VDT- and MRI-derived maps. Simultaneous VDT and imaging was possible in repetition time >32 ms sequences with <0.5 mm errors, and <5% MRI signal-to-noise ratio (SNR) loss. At shorter repetition times, only intracardiac electrocardiogram was reliable. Radiofrequency heating was <1.5°C. CONCLUSION: An MRI-compatible VDT system is feasible.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Pletismografía de Impedancia/instrumentación , Prótesis e Implantes , Tecnología Inalámbrica/instrumentación , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Proyectos Piloto , Porcinos
8.
Phys Med Biol ; 69(18)2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39168156

RESUMEN

Simultaneous positron emission tomography (PET)/magnetic resonance imaging provides concurrent information about anatomic, functional, and molecular changes in disease. We are developing a second generation MR-compatible RF-penetrable TOF-PET insert. The insert has a smaller scintillation crystal size and ring diameter compared to clinical whole-body PET scanners, resulting in higher spatial resolution and sensitivity. This paper reports the initial system performance of this full-ring PET insert. The global photopeak energy resolution and global coincidence time resolution, 11.74 ± 0.03 % FWHM and 238.1 ± 0.5 ps FWHM, respectively, are preserved as we scaled up the system to a full ring comprising 12, 288 LYSO-SiPM channels (crystal size: 3.2 × 3.2 × 20 mm3). Throughout a ten-hour experiment, the system performance remained stable, exhibiting a less than 1% change in all measured parameters. In a resolution phantom study, the system successfully resolved all 2.8 mm diameter rods, achieving an average VPR of 0.28 ± 0.08 without TOF and 0.24 ± 0.07 with TOF applied. Moreover, the implementation of TOF in the Hoffman phantom study also enhanced image quality. Initial MR compatibility studies of the full PET ring were performed with it unpowered as a milestone to focus on looking for material and geometry-related artifacts. During all MR studies, the MR body coil functioned as both the transmit and receive coil, and no observable artifacts were detected. As expected, using the body coil also as the RF receiver, MR image signal-to-noise ratio exhibited degradation (∼30%), so we are developing a high quality receive-only coil that resides inside the PET ring.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Fantasmas de Imagen , Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/instrumentación , Imagen por Resonancia Magnética/instrumentación , Encéfalo/diagnóstico por imagen , Ondas de Radio , Imagen Multimodal/instrumentación , Factores de Tiempo , Procesamiento de Imagen Asistido por Computador/métodos , Humanos
9.
iScience ; 27(1): 108770, 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38261919

RESUMEN

The Centers for Disease Control and Prevention promoted the Test-to-Stay (TTS) program to facilitate in-person instruction in K-12 schools during COVID-19. This program delineates guidelines for schools to regularly test students and staff to minimize risks of infection transmission. TTS enrollment can be implemented via two different consent models: opt-in, in which students do not test regularly by default, and the opposite, opt-out model. We study the impacts of the two enrollment approaches on testing and positivity rates with data from 259 schools in Illinois. Our results indicate that after controlling for other covariates, schools following the opt-out model are associated with 84% higher testing rate and 30% lower positivity rate. If all schools adopted the opt-out model, 20% of the total lost school days could have been saved. The lower positivity rate among the opt-out group is largely explained by the higher testing rate in these schools, a manifestation of status quo bias.

10.
Magn Reson Med ; 70(3): 639-47, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23813444

RESUMEN

PURPOSE: A novel prospective motion correction technique for brain MRI is presented that uses miniature wireless radio-frequency coils, or "wireless markers," for position tracking. METHODS: Each marker is free of traditional cable connections to the scanner. Instead, its signal is wirelessly linked to the MR receiver via inductive coupling with the head coil. Real-time tracking of rigid head motion is performed using a pair of glasses integrated with three wireless markers. A tracking pulse-sequence, combined with knowledge of the markers' unique geometrical arrangement, is used to measure their positions. Tracking data from the glasses is then used to prospectively update the orientation and position of the image-volume so that it follows the motion of the head. RESULTS: Wireless-marker position measurements were comparable to measurements using traditional wired radio-frequency tracking coils, with the standard deviation of the difference < 0.01 mm over the range of positions measured inside the head coil. Wireless-marker safety was verified with B1 maps and temperature measurements. Prospective motion correction was demonstrated in a 2D spin-echo scan while the subject performed a series of deliberate head rotations. CONCLUSION: Prospective motion correction using wireless markers enables high quality images to be acquired even during bulk motions. Wireless markers are small, avoid radio-frequency safety risks from electrical cables, are not hampered by mechanical connections to the scanner, and require minimal setup times. These advantages may help to facilitate adoption in the clinic.


Asunto(s)
Encéfalo/fisiología , Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo , Cabeza , Humanos , Imagen por Resonancia Magnética/métodos , Movimiento (Física)
11.
Phys Med Biol ; 68(13)2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37321248

RESUMEN

Objective. This study aims to evaluate radiofrequency (RF) shielding effectiveness (SE), gradient-induced eddy current, magnetic resonance (MR) susceptibility, and positron emission tomography (PET) photon attenuation of six shielding materials: copper plate, copper tape, carbon fiber fabric, stainless steel mesh, phosphor bronze mesh, and a spray-on conductive coating.Approach. We evaluated the six shielding materials by implementing them on identical clear plastic enclosures. We measured the RF SE and eddy current in benchtop experiments (outside of the MR environment) and in a 3T MR scanner. The magnetic susceptibility performance was evaluated in the same MR scanner. Additionally, we measured their effects on PET detectors, including global coincidence time resolution, global energy resolution, and coincidence count rate.Main results. The RF SEs for copper plate, copper tape, carbon fiber fabric, stainless steel mesh, phosphor bronze mesh, and conductive coating enclosures were 56.8 ± 5.8, 63.9 ± 4.3, 33.1 ± 11.7, 43.6 ± 4.5, 52.7 ± 4.6, and 47.8 ±7.1 dB, respectively, in the benchtop experiment. Copper plate and copper tape experienced the most eddy current at 10 kHz in the benchtop experiment and also generated the largest ghosting artifacts in the MR scanner. Stainless steel mesh had the highest mean absolute difference (7.6 ±0.2 Hz) compared to the reference in the MR susceptibility evaluation. The carbon fiber fabric and phosphor bronze mesh enclosures caused the largest photon attenuation, reducing the coincidence count rate by 3.3%, while the rest caused less than 2.6%.Significance. The conductive coating proposed in this study is shown to be a high-performance Faraday cage material for PET/MRI applications based on its overall performance in all the experiments conducted in this study, as well as its ease and flexibility of manufacturing. As a result, it will be selected as the Faraday cage material for our second-generation MR-compatible PET insert.


Asunto(s)
Cobre , Acero Inoxidable , Fibra de Carbono , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética/métodos
12.
Med Phys ; 50(6): 3389-3400, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36912373

RESUMEN

BACKGROUND: Simultaneous positron emission tomography/magnetic resonance imaging (PET/MRI) has shown promise in acquiring complementary multiparametric information of disease. However, designing these hybrid imaging systems is challenging due to the propensity for mutual interference between the PET and MRI subsystems. Currently, there are integrated PET/MRI systems for clinical applications. For neurologic imaging, a brain-dedicated PET insert provides superior spatial resolution and sensitivity compared to body PET scanners. PURPOSE: Our first-generation prototype brain PET insert ("PETcoil") demonstrated RF-penetrability and MR-compatibility. In the second-generation PETcoil system, all analog silicon photomultiplier (SiPM) signal digitization is moved inside the detectors, which results in substantially better PET detector performance, but presents a greater technical challenge for achieving MR-compatibility. In this paper, we report results from MR-compatibility studies of two fully assembled second-generation PET insert detector modules. METHODS: We studied the effect of the presence of the two second-generation TOF-PET insert detectors on parameters that affect MR image quality and evaluated TOF-PET detector performance under different MRI pulse sequence conditions. RESULTS: With the presence of operating PET detectors, no RF noise peaks were induced in the MR images, but the relative average noise level was increased by 15%, which led to a 3.1 to 4.2-dB degradation in MR image signal-to-noise ratio (SNR). The relative homogeneity of MR images degraded by less than 1.5% with the two operating TOF-PET detectors present. The reported results also indicated that ghosting artifacts (percent signal ghosting (PSG) ⩽ 1%) and MR susceptibility artifacts (0.044 ppm) were insignificant. The PET detector data showed a relative change of less than 5% in detector module performance between running outside and within the MR bore under different MRI pulse sequences except for energy resolution in EPI sequence (13% relative difference). CONCLUSIONS: The PET detector operation did not cause any significant artifacts in MR images and the performance and time-of-flight (TOF) capability of the former were preserved under different tested MR conditions.


Asunto(s)
Imagen por Resonancia Magnética , Imagen Multimodal , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Encéfalo/diagnóstico por imagen , Relación Señal-Ruido , Fantasmas de Imagen
13.
Med Phys ; 48(11): 7283-7298, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34520574

RESUMEN

PURPOSE: To develop an endovaginal MRI array that provides signal enhancement forward into the posterior parametrium and sideways into the vaginal wall, accelerating multiple-contrast detection of residual tumors that survive external beam radiation. The array's enclosure should form an obturator for cervical cancer brachytherapy, allowing integration with MRI-guided catheter placement, CT, and interstitial radiation dose delivery. METHODS: The endovaginal array consisted of forward-looking and sideways-looking components. The forward-looking element imaged the cervix and posterior endometrium, and the sideways-looking elements imaged the vaginal wall. Electromagnetic simulation was performed to optimize the geometry of a forward-looking coil placed on a conductive-metallic substrate, extending the forward penetration above the coil's tip. Thereafter, an endovaginal array with one forward-looking coil and four sideways-looking elements was constructed and tested at 1.5 Tesla in saline and gel phantoms, and three sexually mature swine. Each coil's tuning, matching, and decoupling were optimized theoretically, implemented with electronic circuits, and validated with network-analyzer measurements. The array enclosure emulates a conventional brachytherapy obturator, allowing use of the internal imaging array together with tandem coils and interstitial catheters, as well as use of the enclosure alone during CT and radiation delivery. To evaluate the receive magnetic field ( B 1 - ) spatial profile, the endovaginal array's specific absorption-rate (SAR) distribution was simulated inside a gel ASTM phantom to determine extreme heating locations in advance of a heating test. Heating tests were then performed during high SAR imaging in a gel phantom at the predetermined locations, testing compliance with MRI safety standards. To assess array imaging performance, signal-to-noise-ratios (SNR) were calculated in a saline phantom and in vivo. Swine images were acquired with the endovaginal array combined with the scanner's body and spine arrays. RESULTS: Simulated B 1 - profiles for the forward-looking lobe pattern, obtained while varying several geometric parameters, disclosed that a forward-looking coil placed on a metal-backed substrate could double the effective forward penetration from approximately 25 to ∼40 mm. An endovaginal array, enclosed in an obturator enclosure was then constructed, with all coils tuned, matched, and decoupled. The ASTM gel-phantom SAR test showed that peak local SAR was 1.2 W/kg in the forward-looking coil and 0.3 W/kg in the sideways-looking elements, well within ASTM/FDA/IEC guidelines. A 15-min 4 W/kg average SAR imaging experiment resulted in less than 2o C temperature increase, also within ASTM/FDA/IEC heating limits. In a saline phantom, the forward-looking coil and sideways-looking array's SNR was four to eight times, over a 20-30 mm field-of-view (FOV), and five to eight times, over a 15-25 mm FOV, relative to the spine array's SNR, respectively. In three sexually mature swine, the forward-looking coil provided a 5 + 0.2 SNR enhancement factor within the cervix and posterior endometrium, and the sideways-looking array provided a 4 + 0.2 SNR gain factor in the vaginal wall, relative to the Siemens spine array, demonstrating that the array could significantly reduce imaging time. CONCLUSIONS: Higher SNR gynecological imaging is supported by forward-looking and sideways-looking coils. A forward-looking endovaginal coil for cervix and parametrium imaging was built with optimized metal backing. Array placement within an obturator enhanced integration with the brachytherapy procedure and accelerated imaging for detecting postexternal-beam residual tumors.


Asunto(s)
Braquiterapia , Neoplasias del Cuello Uterino , Animales , Diseño de Equipo , Femenino , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Relación Señal-Ruido , Porcinos , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/radioterapia
14.
Sci Rep ; 11(1): 6264, 2021 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-33731722

RESUMEN

Many educational institutions have partially or fully closed all operations to cope with the challenges of the ongoing COVID-19 pandemic. In this paper, we explore strategies that such institutions can adopt to conduct safe reopening and resume operations during the pandemic. The research is motivated by the University of Illinois at Urbana-Champaign's (UIUC's) SHIELD program, which is a set of policies and strategies, including rapid saliva-based COVID-19 screening, for ensuring safety of students, faculty and staff to conduct in-person operations, at least partially. Specifically, we study how rapid bulk testing, contact tracing and preventative measures such as mask wearing, sanitization, and enforcement of social distancing can allow institutions to manage the epidemic spread. This work combines the power of analytical epidemic modeling, data analysis and agent-based simulations to derive policy insights. We develop an analytical model that takes into account the asymptomatic transmission of COVID-19, the effect of isolation via testing (both in bulk and through contact tracing) and the rate of contacts among people within and outside the institution. Next, we use data from the UIUC SHIELD program and 85 other universities to estimate parameters that describe the analytical model. Using the estimated parameters, we finally conduct agent-based simulations with various model parameters to evaluate testing and reopening strategies. The parameter estimates from UIUC and other universities show similar trends. For example, infection rates at various institutions grow rapidly in certain months and this growth correlates positively with infection rates in counties where the universities are located. Infection rates are also shown to be negatively correlated with testing rates at the institutions. Through agent-based simulations, we demonstrate that the key to designing an effective reopening strategy is a combination of rapid bulk testing and effective preventative measures such as mask wearing and social distancing. Multiple other factors help to reduce infection load, such as efficient contact tracing, reduced delay between testing and result revelation, tests with less false negatives and targeted testing of high-risk class among others. This paper contributes to the nascent literature on combating the COVID-19 pandemic and is especially relevant for educational institutions and similarly large organizations. We contribute by providing an analytical model that can be used to estimate key parameters from data, which in turn can be used to simulate the effect of different strategies for reopening. We quantify the relative effect of different strategies such as bulk testing, contact tracing, reduced infectivity and contact rates in the context of educational institutions. Specifically, we show that for the estimated average base infectivity of 0.025 ([Formula: see text]), a daily number of tests to population ratio T/N of 0.2, i.e., once a week testing for all individuals, is a good indicative threshold. However, this test to population ratio is sensitive to external infectivities, internal and external mobilities, delay in getting results after testing, and measures related to mask wearing and sanitization, which affect the base infection rate.


Asunto(s)
COVID-19/prevención & control , Pandemias/prevención & control , Instituciones Académicas/normas , Universidades/normas , Enfermedades Asintomáticas , Simulación por Computador , Trazado de Contacto/métodos , Humanos , Saliva/virología
15.
Environ Geochem Health ; 32(3): 193-205, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19779837

RESUMEN

Stawell Gold Mine in NW Victoria, Australia, mines ores that contain large concentrations of As and significant quantities of the metals Pb and Cr. The aim of this research was to understand the dispersion, enrichment and probable exposure of these potentially hazardous elements around the mine site. Fifty-five surface soil samples were collected near the mine (<15 km) and analysed by ICP-MS/OES following bioavailable and four-acid extractions. Soils near the mine show greater concentrations of As, Cr and Pb than those near a regionally determined background. This is attributed to the combination of a natural geochemical halo around mineralization and anthropogenic dispersion due to mining and urbanization. Total As concentrations were between 16 and 946 mg kg(-1) near the mine in a regional background of 1-16 mg kg(-1). Total Cr concentrations were between 18 and 740 mg kg(-1) near the mine in a regional background of 26-143 mg kg(-1). Total Pb concentrations were between 12 and 430 mg kg(-1) near the mine in a regional background of 9-23 mg kg(-1). Dispersion of contaminant elements from the present ore processing is <500 m. The most enriched soils occur close to the town and are unrelated to present mining practices. The bioavailable As, Cr and Pb, soil ingestion rates and Risk Reference Doses were used to estimate health risks. An average toddler (12 kg) would need to consume at least 1.5 g, and most likely 12 g, of soil per day to show some symptoms of As toxicity. The maximum measured bioavailable As would pose a risk at average ingestion rates of 200 mg per day. Individuals with soil-eating disorders would exceed the safe daily consumption limits for As, and potentially Cr and Pb. Small children are not typically exposed to soil everyday, very few have soil eating disorders, and, therefore, the health risk from the soils around the mine is minimal.


Asunto(s)
Arsénico/análisis , Cromo/análisis , Exposición a Riesgos Ambientales/análisis , Plomo/análisis , Minería , Contaminantes del Suelo/química , Exposición a Riesgos Ambientales/efectos adversos , Geografía , Humanos , Medición de Riesgo/métodos , Contaminantes del Suelo/análisis , Victoria
16.
IEEE Trans Biomed Eng ; 67(6): 1616-1627, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31535979

RESUMEN

OBJECTIVE: Cardiovascular interventional devices typically have long metallic braids or backbones to aid in steerability and pushability. However, electromagnetic coupling of metallic-based cardiovascular interventional devices with the radiofrequency (RF) fields present during Magnetic Resonance Imaging (MRI) can make a device unsafe for use in an MRI scanner. We aimed to develop MRI conditional actively-tracked cardiovascular interventional devices by sufficiently attenuating induced currents on the metallic braid/tube and internal-cabling using miniaturized resonant floating RF traps (MBaluns). METHOD: MBaluns were designed for placement at multiple locations along a conducting cardiovascular device to prevent the establishment of standing waves and to dissipate RF-induced energy. The MBaluns were constructed with loosely-wound solenoids to be sensitive to transverse magnetic fields created by both surface currents on the device's metallic backbone and common-mode currents on internal cables. Electromagnetic simulations were used to optimize MBalun parameters. Following optimization, two different MBalun designs were applied to MR-actively-tracked metallic guidewires and metallic-braided electrophysiology ablation catheters. Control-devices were constructed without MBaluns. MBalun performance was validated using network-analyzer quantification of current attenuation, electromagnetic Specific-Absorption-Rate (SAR) analysis, thermal tests during high SAR pulse sequences, and MRI-guided cardiovascular navigation in swine. RESULTS: Electromagnetic SAR simulations resulted in ≈20 dB attenuation at the tip of the wire using six successive MBaluns. Network-analyzer tests confirmed ∼17 dB/MBalun surface-current attenuation. Thermal tests indicated temperature decreases of 5.9 °C in the MBalun-equipped guidewire tip. Both devices allowed rapid vascular navigation resulting from good torquability and MR-Tracking visibility. CONCLUSION: MBaluns increased device diameter by 20%, relative to conventional devices, providing a spatially-efficient means to prevent heating during MRI. SIGNIFICANCE: MBaluns allow use of long metallic components, which improves mechanical performance in active MR-guided interventional devices.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Animales , Catéteres , Electrofisiología , Diseño de Equipo , Fantasmas de Imagen , Porcinos
17.
IEEE Trans Biomed Eng ; 67(3): 876-882, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31247538

RESUMEN

Interventional magnetic resonance imaging (MRI) could allow for diagnosis and immediate treatment of ischemic stroke; however, such endovascular catheter-based procedures under MRI guidance are inherently difficult. One major challenge is tracking the tip of the catheter, as standard fabrication methods for building inductively coupled coil markers are rigid and bulky. Here, we report a new approach that uses aerosol jet deposition to three-dimensional (3-D) print an inductively coupled RF coil marker on a polymer catheter. Our approach enables lightweight conforming markers on polymer catheters and these low-profile markers allow the catheter to be more safely navigated in small caliber vessels. Prototype markers with an inductor with the geometry of a double helix are incorporated on catheters for in vitro studies, and we show that these markers exhibit good signal amplification. We report temperature measurements and, finally, demonstrate feasibility in a preliminary in vivo experiment. We provide material properties and electromagnetic simulation performance analysis. This paper presents fully aerosol jet-deposited and functional wireless resonant markers on polymer catheters for use in 3T clinical scanners.


Asunto(s)
Catéteres , Imagen por Resonancia Magnética Intervencional/instrumentación , Imagen por Resonancia Magnética Intervencional/métodos , Tecnología Inalámbrica/instrumentación , Animales , Diseño de Equipo , Femenino , Porcinos , Temperatura
18.
NMR Biomed ; 22(8): 867-73, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19489035

RESUMEN

The ability to accelerate the spatial encoding process during a chemical shift imaging (CSI) scan of hyperpolarized compounds is demonstrated through parallel imaging. A hardware setup designed to simultaneously acquire (13)C data from multiple receivers is presented here. A system consisting of four preamplifiers, four gain stages, a transmit coil, and a four receive channel rat coil was built for single channel excitation and simultaneous multi-channel detection of (13)C signals. The hardware setup was integrated with commercial scanner electronics, allowing the system to function similar to a conventional proton multi-channel setup, except at a different frequency. The ability to perform parallel imaging is demonstrated in vivo. CSI data from the accelerated scans are reconstructed using a self-calibrated multi-spectral parallel imaging algorithm, by using lower resolution coil sensitivity maps obtained from the central region of k-space. The advantages and disadvantages of parallel imaging in the context of imaging hyperpolarized compounds are discussed.


Asunto(s)
Radioisótopos de Carbono/química , Aumento de la Imagen , Imagen por Resonancia Magnética , Ácido Pirúvico/química , Algoritmos , Animales , Humanos , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Ratas , Ratas Sprague-Dawley
19.
Artículo en Inglés | MEDLINE | ID: mdl-18467225

RESUMEN

In the last decade, high intensity focused ultrasound (HIFU) has gained popularity as a minimally invasive and noninvasive therapeutic tool for treatment of cancers, arrhythmias, and other medical conditions. HIFU therapy is often guided by magnetic resonance imaging (MRI), which provides anatomical images for therapeutic device placement, temperature maps for treatment guidance, and postoperative evaluation of the region of interest. While piezoelectric transducers are dominantly used for MR-guided HIFU, capacitive micromachined ultrasonic transducers (CMUTs) show competitive advantages, such as ease of fabrication, integration with electronics, improved efficiency, and reduction of self-heating. In this paper, we will show our first results of an unfocused CMUT transducer monitored by MR-temperature maps. This 2.51 mm by 2.32 mm, unfocused CMUT heated a HIFU phantom by 14 degrees C in 2.5 min. This temperature rise was successfully monitored by MR thermometry in a 3.0 T General Electric scanner.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Termografía/instrumentación , Termografía/métodos , Transductores , Terapia por Ultrasonido/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Calefacción/instrumentación , Terapia por Ultrasonido/métodos
20.
IEEE Trans Med Imaging ; 37(9): 2060-2069, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29993864

RESUMEN

Despite the great promise of integrated positron emission tomography (PET)/magnetic resonance (MR) imaging to add molecular information to anatomical and functional MR, its potential impact in medicine is diminished by a very high cost, limiting its dissemination. An RF-penetrable PET ring that can be inserted into any existing MR system has been developed to address this issue. Employing optical signal transmission along with battery power enables the PET ring insert to electrically float with respect to the MR system. Then, inter-modular gaps of the PET ring allow the RF transmit field from the standard built-in body coil to penetrate into the PET fields-of-view (FOV) with some attenuation that can be compensated for. MR performance, including RF noise, magnetic susceptibility, RF penetrability through and $B_{1}$ uniformity within the PET insert, and MR image quality, were analyzed with and without the PET ring present. The simulated and experimentally measured RF field attenuation factors with the PET ring present were -2.7 and -3.2 dB, respectively. The magnetic susceptibility effect (0.063 ppm) and noise emitted from the PET ring in the MR receive channel were insignificant. $B_{1}$ homogeneity of a spherical agar phantom within the PET ring FOV dropped by 8.4% and MR image SNR was reduced by 3.5 and 4.3 dB with the PET present for gradient-recalled echo and fast-spin echo, respectively. This paper demonstrates, for the first time, an RF-penetrable PET insert comprising a full ring of operating detectors that achieves simultaneous PET/MR using the standard built-in body coil as the RF transmitter.


Asunto(s)
Imagen por Resonancia Magnética , Imagen Multimodal , Tomografía de Emisión de Positrones , Encéfalo/diagnóstico por imagen , Diseño de Equipo , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/instrumentación , Imagen Multimodal/métodos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA