Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 34(7): 4309-4320, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38148406

RESUMEN

OBJECTIVES: The purpose of this meta-analysis was to determine the diagnostic performance of conventional MRI and MR arthrography for tendinosis, and partial and complete tears of the long head of the biceps tendon (LHBT) using arthroscopy as the reference standard. MATERIALS AND METHODS: A systematic review was performed using predefined data fields in PubMed, and all articles published from January 2000 up to April 2022 were retrospectively pooled and reviewed. Six MRI studies on complete tear (n = 555) and ten studies on partial tear/tendinosis (n = 2487) were included in the analysis. Two of the included studies in each group investigated the use of MR arthrography. The data sets were analyzed using a univariate approach with the DerSimonian and Laird random effects model and the proportional hazards model. RESULTS: MRI shows high specificities in diagnosing complete tears of the LHBT ranging from 93.0 to 99.0%. Diagnostic sensitivity was more heterogeneous ranging from 55.9 to 90.0%. The overall negative likelihood ratio was 0.29 (95% CI: 0.17-0.50) and the overall positive likelihood ratio was 37.3 (95% CI: 11.9-117.4). The mean sensitivity in diagnosing partial tear/tendinosis of the LHBT was 67.8% (95% CI: 54.3-78.9%) and the specificity was 75.9% (95% CI: 63.6-85.0%), resulting in a balanced accuracy of 71.9%. The overall negative likelihood ratio was 0.44 (95% CI: 0.32-0.59) and the overall positive likelihood ratio was 2.64 (95% CI: 1.91-3.65). CONCLUSION: MRI is highly specific for the diagnosis of complete tears of the LHBT, whereas diagnostic sensitivity was more heterogeneous. The diagnosis of partial tears and/or tendinosis of the LHBT remains challenging on MRI, which may warrant complementary clinical examination or other imaging modalities to increase diagnostic confidence in equivocal cases. CLINICAL RELEVANCE STATEMENT: Conventional MRI and MR arthrography have high diagnostic performance for complete tendon tear when compared to arthroscopy. The diagnosis of tendinosis/partial tears remains challenging and may require comparison with clinical tests and other imaging modalities. KEY POINTS: •There is no clear consensus regarding the primary imaging modality for the evaluation of LHBT disorders. •Conventional MRI and MR arthrography are highly specific in diagnosing complete tears of the LHBT. •Diagnosis of partial tears/tendinosis of the LHBT on conventional MRI and MR arthrography remains a diagnostic challenge.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Traumatismos de los Tendones/diagnóstico por imagen , Tendinopatía/diagnóstico por imagen , Artroscopía
2.
Eur Radiol ; 34(3): 1556-1566, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37658140

RESUMEN

OBJECTIVE: Bioabsorbable magnesium-based alloy screws release gas upon resorption. The resulting findings in the adjacent soft tissues and joints may mimic infection. The aim of the study was to evaluate the ultrasound (US) findings in soft tissues and joints during screw resorption. METHODS: Prospectively acquired US studies from pediatric patients treated with magnesium screws were evaluated for screw head visibility, posterior acoustic shadowing, twinkling artifact, foreign body granuloma, gas (soft tissue, intra-articular), alterations of the skin and subcutaneous fat, perifascial fluid, localized fluid collections, hypervascularization, and joint effusion. RESULTS: Sixty-six US studies of 28 pediatric patients (nfemale = 9, nmale = 19) were included. The mean age of the patients at the time of surgery was 10.84 years; the mean time between surgery and ultrasound was 128.3 days (range = 6-468 days). The screw head and posterior acoustic shadowing were visible in 100% of the studies, twinkling artifact in 6.1%, foreign body granuloma in 92.4%, gas locules in soft tissue in 100% and intra-articular in 18.2%, hyperechogenicity of the subcutaneous fat in 90.9%, cobblestoning of the subcutaneous fat in 24.2%, loss of normal differentiation between the epidermis/dermis and the subcutaneous fat in 57.6%, localized fluid collection in 9.9%, perifascial fluid in 12.1%, hypervascularization in 27.3%, and joint effusion in 18.2%. CONCLUSION: US findings in pediatric patients treated with magnesium screws strongly resemble infection, but are normal findings in the setting of screw resorption. CLINICAL RELEVANCE STATEMENT: Bioabsorbable magnesium-based alloy screws release gas during resorption. The resulting US findings in the adjacent soft tissues and joints in pediatric patients may mimic infection, but are normal findings. KEY POINTS: • Bioabsorbable magnesium-based alloy screws release gas upon resorption. • The resulting ultrasound findings in children's soft tissues and joints closely resemble those of soft tissue infection or osteosynthesis-associated infection. • Be familiar with these ultrasound findings in order to avoid inadvertently misdiagnosing a soft tissue infection or osteosynthesis-associated infection.


Asunto(s)
Fracturas Óseas , Granuloma de Cuerpo Extraño , Infecciones de los Tejidos Blandos , Humanos , Masculino , Femenino , Niño , Magnesio , Implantes Absorbibles , Granuloma de Cuerpo Extraño/etiología , Infecciones de los Tejidos Blandos/etiología , Fracturas Óseas/etiología , Aleaciones , Fijación Interna de Fracturas/métodos , Tornillos Óseos/efectos adversos
3.
BMC Pediatr ; 24(1): 315, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714956

RESUMEN

BACKGROUND: Ultrasound (US) is often the first method used to look for brain or cerebrospinal fluid (CSF) space pathologies. Knowledge of normal CSF width values is essential. Most of the available US normative values were established over 20 years ago, were obtained with older equipment, and cover only part of the age spectrum that can be examined by cranial US. This prospective study aimed to determine the normative values of the widths of the subarachnoid and internal CSF spaces (craniocortical, minimal and maximal interhemispheric, interventricular, and frontal horn) for high-resolution linear US probes in neurologically healthy infants and children aged 0-19 months and assess whether subdural fluid collections can be delineated. METHODS: Two radiologists measured the width of the CSF spaces with a conventional linear probe and an ultralight hockey-stick probe in neurologically healthy children not referred for cranial or spinal US. RESULTS: This study included 359 neurologically healthy children (nboys = 178, 49.6%; ngirls = 181, 50.4%) with a median age of 46.0 days and a range of 1-599 days. We constructed prediction plots, including the 5th, 50th, and 95th percentiles, and an interactive spreadsheet to calculate normative values for individual patients. The measurements of the two probes and the left and right sides did not differ, eliminating the need for separate normative values. No subdural fluid collection was detected. CONCLUSION: Normative values for the widths of the subarachnoid space and the internal CSF spaces are useful for evaluating intracranial pathology, especially when determining whether an increase in the subarachnoid space width is abnormal.


Asunto(s)
Espacio Subaracnoideo , Ultrasonografía , Humanos , Lactante , Estudios Prospectivos , Masculino , Femenino , Valores de Referencia , Recién Nacido , Ultrasonografía/métodos , Espacio Subaracnoideo/diagnóstico por imagen , Líquido Cefalorraquídeo/diagnóstico por imagen
4.
Neuroradiology ; 65(4): 729-736, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36633612

RESUMEN

PURPOSE: To evaluate and compare which factors are relevant to the diagnostic decision-making and imaging workup of intracerebral hemorrhages in large, specialized European centers. METHODS: Expert neuroradiologists from ten large, specialized centers (where endovascular stroke treatment is routinely performed) in nine European countries were selected in cooperation with the European Society of Neuroradiology (ESNR). The experts were asked to describe how and when they would investigate specific causes in a patient who presented with an acute, atraumatic, intracerebral hemorrhage for two given locations: (1) basal ganglia, thalamus, pons or cerebellum; (2) lobar hemorrhage. Answers were collected, and decision trees were compared. RESULTS: Criteria that were considered relevant for decision-making reflect recommendations from current guidelines and were similar in all participating centers. CT Angiography or MR angiography was considered essential by the majority of centers regardless of other factors. Imaging in clinical practice tended to surpass guideline recommendations and was heterogeneous among different centers, e.g., in a scenario suggestive of typical hypertensive hemorrhage, recommendations ranged from no further follow-up imaging to CT angiography and MR angiography. In no case was a consensus above 60% achieved. CONCLUSION: In European clinical practices, existing guidelines for diagnostic imaging strategies in ICH evaluation are followed as a basis but in most cases, additional imaging investigation is undertaken. Significant differences in imaging workup were observed among the centers. Results suggest a high level of awareness and caution regarding potentially underlying pathology other than hypertensive disease.


Asunto(s)
Hemorragia Cerebral , Accidente Cerebrovascular , Humanos , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/patología , Accidente Cerebrovascular/terapia , Europa (Continente) , Tomografía Computarizada por Rayos X , Hospitales
5.
J Magn Reson Imaging ; 56(5): 1571-1579, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35106870

RESUMEN

BACKGROUND: Diagnosis of osteomyelitis by imaging can be challenging. The feasibility of diffusion-weighted imaging (DWI) as ancillary sequence was evaluated in this study. PURPOSE: To evaluate DWI for differentiation between osteomyelitis, bone marrow edema, and healthy bone on forefoot magnetic resonance imaging (MRI). STUDY TYPE: Prospective. SUBJECTS: A total of 60 consecutive patients undergoing forefoot MRI divided into three study groups (20 subjects each): osteomyelitis, bone marrow edema, and healthy bone. FIELD STRENGTH/SEQUENCE: A 1.5T and 3T MRI scanners; readout-segmented multishot echo planar DWI. ASSESSMENT: Two independent radiologists measured apparent diffusion coefficient (ADC) values within abnormal or healthy bone. STATISTICAL TESTS: ADC values were compared between groups (pairwise t-test with Bonferroni-Holm correction for multiple testing). Intraclass correlation coefficient (ICC) was calculated to assess inter-reader agreement. Threshold ADC values were determined as the cutoffs that maximized the sum of sensitivity and specificity. Receiver operating characteristic (ROC) analysis was performed with statistical threshold of P < 0.05. RESULTS: Inter-reader agreement was 0.92 in the healthy bone group and 0.78 in both the edema and osteomyelitis groups. Average ADC values were significantly different between groups: 1432 ± 222 × 10-6  mm2 /sec (osteomyelitis), 1071 ± 196 × 10-6  mm2 /sec (bone marrow edema), and 277 ± 89 × 10-6  mm2 /sec (healthy bone). A threshold ADC value of 534 × 10-6  mm2 /sec distinguishes between healthy and abnormal bone with specificity and sensitivity of 100% each. For distinction between osteomyelitis and bone marrow edema, two cutoff values were determined: a 95%-specificity cutoff indicating osteomyelitis (>1320 × 10-6  mm2 /sec) and a 95%-sensitivity cutoff indicating bone marrow edema (<1155 × 10-6  mm2 /sec). Diagnostic accuracy of 95% was achieved for 73% (29/40) of the subjects. DATA CONCLUSION: DWI with ADC maps distinguishes between healthy and abnormal bone on forefoot MRI. Calculated cutoff values allow confirmation or exclusion of osteomyelitis in a high proportion of subjects. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Enfermedades de la Médula Ósea , Osteomielitis , Médula Ósea/diagnóstico por imagen , Médula Ósea/patología , Enfermedades de la Médula Ósea/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Edema/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Osteomielitis/diagnóstico por imagen , Estudios Prospectivos , Sensibilidad y Especificidad
6.
BMC Pediatr ; 22(1): 584, 2022 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-36209062

RESUMEN

BACKGROUND: The size of the anterior visual pathway (AVP) structures is affected by patient age and pathology. Normative data is useful when determining whether pathology is present. AVP structures do not respect the standard planes of magnetic resonance (MR) imaging. The aim of this study was to produce normative age-related and axis-corrected data of the AVP structures using multiplanar reformation (MPR) of high-resolution 3D T2-weighted fast spin echo (3D T2w FSE) images. METHODS: For each patient 32 measurements of AVP structures were obtained in 145 children (2 months - 18 years) with normal brain MR studies on high-resolution 3D T2w FSE images adjusted to the axis of each AVP structure. Descriptive statistics were calculated for different age classes and growth models were fitted to the data and assessed for their performance to create a formal statistical model that allows inference beyond the sample. RESULTS: Descriptive statistics were compiled in a reference table and prediction plots in relation to age, height, and body surface area (BSA) were obtained from the best overall performing statistical model, also taking field strength (1.5 vs. 3 T) into account. Intraclass correlation coefficient values were calculated for all variables ranging from 0.474 to 0.967, the most reliable being the transverse diameter of the globe, the maximum diameter of the retrobulbar nerve sheath, the intracranial segment of the optic nerve and the transverse diameter of the chiasm. The maximum retrobulbar diameter of the optic nerve sheath and the lateral superoinferior diameter of the chiasm showed no statistically significant change with age. CONCLUSION: Detailed charts of reference values for AVP structures as well as prediction plots in relation to age, height and BSA were established using axis-corrected measurements from the MPR of high-resolution 3D T2w FSE images. Furthermore, an Excel spreadsheet that allows users to calculate normative values for the 9 AVP structures of key interest is provided as supplementary material.


Asunto(s)
Imagenología Tridimensional , Vías Visuales , Niño , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Modelos Estadísticos , Valores de Referencia , Vías Visuales/diagnóstico por imagen
7.
Acta Radiol ; 63(6): 743-749, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33940960

RESUMEN

BACKGROUND: After computed tomography (CT)-guided interventions, routine in-hospital observation is recommended by the Cardiovascular and Interventional Radiological Society of Europe. PURPOSE: To evaluate the frequency of delayed major complications or hospitalizations after CT-guided biopsies in patients with initially no or minor complications and to assess whether routine in-hospital observation is justified. MATERIAL AND METHODS: This retrospective study included 433 outpatients after CT-guided biopsy of the thoracic (n = 176), abdominal (n = 129), or musculoskeletal (n = 128) region with subsequent in-hospital observation. Complications were graded according to the current Society of Interventional Radiology recommendations and grouped into minor or major. A complication that occurred during in-hospital observation was defined as delayed complication. A delayed major complication was a newly developed major complication or a progression from an initially minor to a major complication. Hospitalization frequencies were evaluated similarly. Occurrence, 95% confidence intervals (CI), and P values for significant differences between the three organ groups were calculated. If delayed major complications were more frequent than 1%, routine in-hospital observation was considered justified. RESULTS: Delayed, major complication frequencies were: thoracic, 8.2% (95% CI 4.6-13.4); abdominal, 0.0% (95% CI 0.0-2.9); and musculoskeletal, 0.0% (95% CI 0.0-2.9) (P < 0.001). Delayed hospitalization frequencies were: thoracic, 8.8% (95% CI 5.0-14.2); abdominal, 1.6% (95% CI 0.2-5.6); and musculoskeletal, 0.0% (95% CI 0.0-2.9) (P < 0.001). CONCLUSION: After thoracic interventions, routine observation is considered justified for patient safety whereas routine observation may be omitted after musculoskeletal interventions. In the abdominal group, no delayed complications were observed, but delayed hospitalization occurred. Thus, in-hospital observation could be justified in a safe patient environment, but remains an individual decision.


Asunto(s)
Biopsia Guiada por Imagen , Radiografía Intervencional , Hospitales , Humanos , Biopsia Guiada por Imagen/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
8.
Pediatr Radiol ; 52(13): 2584-2594, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35836016

RESUMEN

BACKGROUND: Exposure of the eye lens to ionizing radiation results in cataract. Several dose optimization techniques to protect the lens are available for computed tomography (CT). OBJECTIVE: The radiation dose to the eye lens, volume CT dose index (CTDIvol) and image quality of various methods of dose optimization were evaluated for pediatric head CT: automated tube current modulation (ATCM), automated tube voltage selection (ATVS), organ-based tube current modulation (OBTCM) and bismuth shielding. MATERIALS AND METHODS: An anthropomorphic phantom of a 5-year-old child was scanned with nine protocols: no dose optimization technique and then adding different dose optimization techniques alone and in combination. Dose to the eye, thyroid and breast were estimated using metal oxide semiconductor field effect transistor (MOSFET) dosimetry. CTDIvol, influence of timing of shield placement, image noise and attenuation values in 13 regions of interest of the head and subjective image quality were compared. RESULTS: The eye shield significantly reduced the eye lens dose when used alone, to a similar degree as when using all software-based techniques together. When used in combination with software-based techniques, the shield reduced the eye lens dose by up to 45% compared to the no dose optimization technique. Noise was significantly increased by the shield, most pronounced in the anterior portion of the eye. CONCLUSION: The combination of ATCM, ATVS, OBTCM and a bismuth shield, with the shield placed after acquiring the localizer image, should be considered to reduce the radiation dose to the eye lens in pediatric head CT.


Asunto(s)
Bismuto , Protección Radiológica , Niño , Humanos , Preescolar , Dosis de Radiación , Protección Radiológica/métodos , Cabeza/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen
9.
Skeletal Radiol ; 51(3): 573-579, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34255126

RESUMEN

OBJECTIVE: Short tau or short TI inversion recovery (STIR) MRI sequences are considered a robust fat suppression technique. However, STIR also suppresses signals from other tissues with similar T1 relaxation times. This study investigates the in vivo effect of intravenous gadolinium-based T1-shortening contrast agent on STIR signal. MATERIALS AND METHODS: Institutional board approval and informed consent was obtained. MRI examinations (1.5-T or 3-T) of 31 prospectively included patients were analyzed by two readers. Signal intensity of degenerative bone marrow edema-like signal at the Lisfranc joint on precontrast STIR images and on STIR images acquired after intravenous contrast agent administration (gadoteric acid, gadolinium: 0.5 mmol/ml, 15 ml) was measured. The medial cuneiform bone without observable bone marrow edema-like signal was considered a healthy tissue and served as a reference. Relative changes in signal intensity between precontrast and postcontrast images were calculated for the two tissues. Wilcoxon signed-rank test served for statistical analyses. RESULTS: In bone marrow edema-like signal, both readers observed a median signal change of -35% (interquartile range (IQR) 24) and -34% (IQR 21), respectively, on postcontrast STIR images compared to precontrast STIR. In healthy tissue, the signal remained constant on postcontrast STIR images (median change -2%, IQR 15, and 0%, IQR 17) respectively. For both readers, postcontrast signal change in bone marrow edema-like signal differed from that in healthy tissue (p < 0.001). CONCLUSION: Intravenous gadolinium-based contrast agent causes a significant reduction of signal intensity in bone marrow edema-like signal on routine STIR images. Thus, pathological MRI findings may be obscured.


Asunto(s)
Enfermedades de la Médula Ósea , Medios de Contraste , Médula Ósea/diagnóstico por imagen , Enfermedades de la Médula Ósea/inducido químicamente , Enfermedades de la Médula Ósea/diagnóstico por imagen , Edema/inducido químicamente , Edema/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
10.
BMC Pediatr ; 21(1): 276, 2021 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-34116649

RESUMEN

BACKGROUND: Organ size is influenced by a number of factors. Age, height, weight, and ethnicity are known influencing factors. Pediatric populations have changed over time, puberty beginning earlier resulting in a changing growth pattern of their organs. Hence, contemporary charts using local data are considered the most appropriate for a given population. Sonographic charts for liver size for a predominantly Caucasian population are limited, which has implications for clinical practice. The aim of this study was to define a contemporary normative range of liver and spleen sizes for a healthy, predominantly Caucasian population and for all pediatric age groups (0-18 years) and to investigate whether there is a size difference between genders and ethnicities. METHODS: Retrospective study including children with normal sonographic findings and no evidence of liver or splenic disease clinically. Craniocaudal and anteroposterior dimensions are measured for the right and left lobe of the liver, and craniocaudal dimension for the spleen. Relationship of the liver and spleen dimensions with age, body length, body surface area, weight, and gender were investigated. Charts of normal values were established. Values were compared to studies involving other ethnicities and to one study carried out in 1983 involving the same ethnicity. RESULTS: Seven hundred thirty-six children (371 boys, 365 girls) aged 1 day - 18.4 years were included. From the second year of life, the craniocaudal dimension of the right lobe of the liver is 1-2 cm larger in the Central European population compared with non-Caucasian populations at a given age. Liver size of Central European children in 2020 is greater compared to a similar population almost 40 years ago. The craniocaudal dimension of the spleen of Central European, US-American and Turkish children is similar. The difference between genders is statistically significant for both the liver and the spleen, being larger in boys. CONCLUSION: Contemporary and ethnically appropriate reference charts for liver and spleen measurements should be used, especially for liver size. The effect of ethnicity is reduced if patient height rather than age is referenced.


Asunto(s)
Hígado , Bazo , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Hígado/diagnóstico por imagen , Masculino , Tamaño de los Órganos , Valores de Referencia , Estudios Retrospectivos , Bazo/diagnóstico por imagen , Ultrasonografía
11.
Skeletal Radiol ; 49(11): 1819-1827, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32524168

RESUMEN

OBJECTIVE: To determine diagnostic confidence and inter-observer/intra-observer agreement in differentiating epidural fibrosis from disc herniation and lumbar spinal stenosis parameters on magnetic resonance images (MRI) in postoperative lumbar spines with (Gad-MRI) and without (unenhanced MRI) intravenous gadolinium-based contrast agent. SUBJECTS AND METHODS: N = 124 lumbar spine MRI examinations of four groups were included: 1-6 months, 7-18 months, 19-36 months, more than 37 months between lumbar spine surgery and imaging. Two radiologists evaluated Gad-MRI and unenhanced MRI: diagnostic confidence was determined as confident or unconfident. Inter-observer and intra-observer agreement were assessed in differentiating epidural fibrosis from disc herniation and for lumbar spinal stenosis parameters on MRI. Fisher's exact test and Cohen's kappa served for statistics. RESULTS: Diagnostic confidence in differentiating epidural fibrosis from disc herniation was significantly higher on Gad-MR images compared with unenhanced MRI at 1-18 months for observer 1 and at 1-6 months postoperatively for observer 2 (p values: 0.01-0.025). Inter-observer agreement at 1-6 months postoperatively for identification of epidural fibrosis was higher on Gad-MRI (kappa values: 0.53 versus 0.24). Inter-observer and intra-observer agreement for identification of disc herniation and for assessment of lumbar spinal stenosis parameters revealed inconsistent data, without a trend for higher inter-observer or intra-observer agreement on Gad-MRI compared with unenhanced MRI (kappa values: 0.17-0.75). CONCLUSION: Gad-MR images compared with unenhanced MRI improved diagnostic confidence and agreement in differentiating epidural fibrosis from disc herniation for both observers in the first 6 months and for one observer in the first 18 months after lumbar spine surgery. After 18 months, Gad-MR images compared with unenhanced MRI did neither improve confidence nor agreement.


Asunto(s)
Desplazamiento del Disco Intervertebral , Imagen por Resonancia Magnética , Fibrosis , Humanos , Desplazamiento del Disco Intervertebral/diagnóstico por imagen , Desplazamiento del Disco Intervertebral/patología , Desplazamiento del Disco Intervertebral/cirugía , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/patología , Vértebras Lumbares/cirugía , Variaciones Dependientes del Observador
12.
Analyst ; 144(23): 6850-6857, 2019 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-31591608

RESUMEN

Despite its crucial role, the placenta is the least understood human organ. Recent clinical studies indicate a direct association between placental calcification and maternal and offspring health. This study reveals distinct characteristics of minerals formed during gestational ageing using cutting-edge nano-analytical characterization and paves the way for investigations focused on the identification of potential markers for disease risks in a clinical setting based on atypical placental mineral fingerprints.


Asunto(s)
Calcificación Fisiológica/fisiología , Minerales/análisis , Placenta/metabolismo , Animales , Gatos , Perros , Femenino , Caballos , Humanos , Microscopía Electrónica de Rastreo , Minerales/química , Minerales/metabolismo , Placenta/ultraestructura , Embarazo , Conejos , Análisis Espectral , Tomografía Computarizada por Rayos X
13.
Eur Radiol ; 28(5): 2143-2150, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29218617

RESUMEN

OBJECTIVES: To investigate the impact of an adaptive detector collimation on the dose parameters and accurateness of scan length adaption at prospectively ECG-triggered sequential cardiac CT with a wide-detector third-generation dual-source CT. METHODS: Ideal scan lengths for human hearts were retrospectively derived from 103 triple-rule-out examinations. These measures were entered into the new scanner operated in prospectively ECG-triggered sequential cardiac scan mode with three different detector settings: (1) adaptive collimation, (2) fixed 64 × 0.6-mm collimation, and (3) fixed 96 × 0.6-mm collimation. Differences in effective scan length and deviation from the ideal scan length and dose parameters (CTDIvol, DLP) were documented. RESULTS: The ideal cardiac scan length could be matched by the adaptive collimation in every case while the mean scanned length was longer by 15.4% with the 64 × 0.6 mm and by 27.2% with the fixed 96 × 0.6-mm collimation. While the DLP was almost identical between the adaptive and the 64 × 0.6-mm collimation (83 vs. 89 mGycm at 120 kV), it was 62.7% higher with the 96 × 0.6-mm collimation (135 mGycm), p < 0.001. CONCLUSION: The adaptive detector collimation for prospectively ECG-triggered sequential acquisition allows for adjusting the scan length as accurate as this can only be achieved with a spiral acquisition. This technique allows keeping patient exposure low where patient dose would significantly increase with the traditional step-and-shoot mode. KEY POINTS: • Adaptive detector collimation allows keeping patient exposure low in cardiac CT. • With novel detectors the desired scan length can be accurately matched. • Differences in detector settings may cause 62.7% of excessive dose.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Electrocardiografía , Tomografía Computarizada Multidetector/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación
14.
Eur Radiol ; 28(7): 2756-2762, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29417250

RESUMEN

OBJECTIVES: We investigated the potential reduction of patient exposure during invasive coronary angiography (ICA) if the procedure had only been directed to the vessel with at least one ≥ 50% stenosis as described in the CT report. METHODS: Dose reports of 61 patients referred to ICA because of at least one ≥ 50% stenosis on coronary CT angiography (CCTA) were included. Dose-area product (DAP) was documented separately for left (LCA) and right coronary arteries (RCA) by summing up the single DAP for each angiographic projection. The study population was subdivided as follows: coronary intervention of LCA (group 1) or RCA (group 2) only, or of both vessels (group 3), or further bypass grafting (group 4), or no further intervention (group 5). RESULTS: 57.4% of the study population could have benefitted from reduced exposure if catheterization had been directly guided to the vessel of interest as described on CCTA. Mean relative DAP reductions were as follows: group 1 (n = 18), 11.2%; group 2 (n = 2), 40.3%; group 3 (n = 10), 0%; group 4 (n = 3), 0%; group 5 (n = 28), 28.8%. CONCLUSIONS: Directing ICA to the vessel with stenosis as described on CCTA would reduce intraprocedural patient exposure substantially, especially for patients with single-vessel stenosis. KEY POINTS: • Patients with CAD can benefit from decreased radiation exposure during coronary angiography. • ICA should be directed solely to significant stenoses as described on CCTA. • Severely calcified plaques remain a limitation of CCTA leading to unnecessary ICA referrals.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Anciano , Enfermedad de la Arteria Coronaria/patología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/patología , Estenosis Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Exposición a la Radiación/prevención & control , Radiografía Intervencional/métodos , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tórax
15.
Eur Radiol ; 27(8): 3290-3299, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28093625

RESUMEN

PURPOSE: To prospectively evaluate the accuracy of ultralow radiation dose CT of the chest with tin filtration at 100 kV for pulmonary nodule detection. MATERIALS AND METHODS: 202 consecutive patients undergoing clinically indicated chest CT (standard dose, 1.8 ± 0.7 mSv) were prospectively included and additionally scanned with an ultralow dose protocol (0.13 ± 0.01 mSv). Standard dose CT was read in consensus by two board-certified radiologists to determine the presence of lung nodules and served as standard of reference (SOR). Two radiologists assessed the presence of lung nodules and their locations on ultralow dose CT. Sensitivity and specificity of the ultralow dose protocol was compared against the SOR, including subgroup analyses of different nodule sizes and types. A mixed effects logistic regression was used to test for independent predictors for sensitivity of pulmonary nodule detection. RESULTS: 425 nodules (mean diameter 3.7 ± 2.9 mm) were found on SOR. Overall sensitivity for nodule detection by ultralow dose CT was 91%. In multivariate analysis, nodule type, size and patients BMI were independent predictors for sensitivity (p < 0.001). CONCLUSIONS: Ultralow dose chest CT at 100 kV with spectral shaping enables a high sensitivity for the detection of pulmonary nodules at exposure levels comparable to plain film chest X-ray. KEYPOINTS: • 91% of all lung nodules were detected with ultralow dose CT • Sensitivity for subsolid nodule detection is lower in ultralow dose CT (77.5%) • The mean effective radiation dose in 202 patients was 0.13 mSv • Ultralow dose CT seems to be feasible for lung cancer screening.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Detección Precoz del Cáncer/métodos , Estudios de Factibilidad , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Sensibilidad y Especificidad , Adulto Joven
16.
J Comput Assist Tomogr ; 41(4): 572-577, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28240633

RESUMEN

OBJECTIVE: To evaluate the effectiveness and clinical utility of a metal artifact reduction (MAR) image reconstruction algorithm for the reduction of high-attenuation object (HAO)-related image artifacts. METHODS: Images were quantitatively evaluated for image noise (noiseSD and noiserange) and qualitatively for artifact severity, gray-white-matter delineation, and diagnostic confidence with conventional reconstruction and after applying a MAR algorithm. RESULTS: Metal artifact reduction reduces noiseSD and noiserange (median [interquartile range]) at the level of HAO in 1-cm distance compared with conventional reconstruction (noiseSD: 60.0 [71.4] vs 12.8 [16.1] and noiserange: 262.0 [236.8] vs 72.0 [28.3]; P < 0.0001). Artifact severity (reader 1 [mean ± SD]: 1.1 ± 0.6 vs 2.4 ± 0.5, reader 2: 0.8 ± 0.6 vs 2.0 ± 0.4) at level of HAO and diagnostic confidence (reader 1: 1.6 ± 0.7 vs 2.6 ± 0.5, reader 2: 1.0 ± 0.6 vs 2.3 ± 0.7) significantly improved with MAR (P < 0.0001). Metal artifact reduction did not affect gray-white-matter delineation. CONCLUSIONS: Metal artifact reduction effectively reduces image artifacts caused by HAO and significantly improves diagnostic confidence without worsening gray-white-matter delineation.


Asunto(s)
Algoritmos , Artefactos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Reproducibilidad de los Resultados
17.
Eur Radiol ; 26(2): 459-68, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26037718

RESUMEN

PURPOSE: To evaluate the potential of advanced modeled iterative reconstruction (ADMIRE) for optimizing radiation dose of high-pitch coronary CT angiography (CCTA). METHODS: High-pitch 192-slice dual-source CCTA was performed in 25 patients (group 1) according to standard settings (ref. 100 kVp, ref. 270 mAs/rot). Images were reconstructed with filtered back projection (FBP) and ADMIRE (strength levels 1-5). In another 25 patients (group 2), high-pitch CCTA protocol parameters were adapted according to results from group 1 (ref. 160 mAs/rot), and images were reconstructed with ADMIRE level 4. In ten patients of group 1, vessel sharpness using full width at half maximum (FWHM) analysis was determined. Image quality was assessed by two independent, blinded readers. RESULTS: Interobserver agreements for attenuation and noise were excellent (r = 0.88/0.85, p < 0.01). In group 1, ADMIRE level 4 images were most often selected (84%, 21/25) as preferred data set; at this level noise reduction was 40% compared to FBP. Vessel borders showed increasing sharpness (FWHM) at increasing ADMIRE levels (p < 0.05). Image quality in group 2 was similar to that of group 1 at ADMIRE levels 2-3. Radiation dose in group 2 (0.3 ± 0.1 mSv) was significantly lower than in group 1 (0.5 ± 0.3 mSv; p < 0.05). CONCLUSIONS: In a selected population, ADMIRE can be used for optimizing high-pitch CCTA to an effective dose of 0.3 mSv. KEY POINTS: • Advanced modeled IR (ADMIRE) reduces image noise up to 50% as compared to FBP. • Coronary artery vessel borders show an increasing sharpness at higher ADMIRE levels. • High-pitch CCTA with ADMIRE is possible at a radiation dose of 0.3 mSv.


Asunto(s)
Angiografía Coronaria/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos
18.
Forensic Sci Med Pathol ; 11(1): 20-8, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25566768

RESUMEN

PURPOSE: To investigate the dual-energy CT behavior of cocaine and heroin and of typical adulterants, and to evaluate the elemental composition of pure cocaine and heroin compared with cocaine and heroin in bodypacks. METHODS: Pure heroin and pure synthetic cocaine samples, eight different adulterants, and in each case ten different bodypacks containing cocaine or heroin, were imaged at 80, 100, 120, and 140 kVp in a dual source CT system at two different degrees of compression. Two radiologists, blinded to the samples, measured the attenuation. The dual-energy index (DEI) was calculated. We performed atomic mass spectrometry for the elemental analysis of pure cocaine, pure heroin, and heroin and cocaine in bodypacks, and 140 kVp in a dual-source CT system. RESULTS: Inter- and intra-observer agreement for attenuation measurements was good (r = 0.61-0.72; p < 0.01). The cocaine bodypacks had a positive DEI of 0.029, while the pure drugs and the heroin bodypacks had a negative DEI (-0.051 to -0.027). Levamisole was the only substance which expressed a positive DEI of 0.011, while the remaining adulterants had negative DEIs ranging between -0.015 and -0.215. Atomic mass spectrometry revealed a concentration of tin in the cocaine bodypack that was 67 times higher than in the pure synthetic cocaine sample. CONCLUSIONS: The different DEIs of bodypacks containing cocaine and heroin allow them to be distinguished with dual-energy CT. Although the material properties of pure cocaine, pure heroin, or common drug extenders do not explain the differences in DEI, tin contamination during illicit natural cocaine production may be a possible explanation.


Asunto(s)
Cocaína/análisis , Contaminación de Medicamentos , Tráfico de Drogas , Cuerpos Extraños/diagnóstico por imagen , Heroína/análisis , Tomografía Computarizada Multidetector , Humanos , Espectrometría de Masas , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
19.
Eur Radiol ; 24(8): 1889-95, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24838737

RESUMEN

OBJECTIVES: To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). METHODS: First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. RESULTS: In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. CONCLUSIONS: Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. KEY POINTS: • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average.


Asunto(s)
Artefactos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagenología Tridimensional , Tomografía Computarizada Multidetector/métodos , Fantasmas de Imagen , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Reproducibilidad de los Resultados
20.
ESC Heart Fail ; 11(2): 893-901, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38200702

RESUMEN

AIM: Pleural effusion (PE) is a common chest radiography (CXR) finding in patients with advanced cardiac disease. The pathophysiology and clinical value of PE in this setting are incompletely defined. We aimed to assess the haemodynamic correlates and prognostic impact of PE in patients with severe aortic stenosis (AS). METHODS AND RESULTS: We studied 471 patients (mean age 74 ± 10 years) with severe AS (indexed aortic valve area 0.42 ± 0.12 cm2/m2, left ventricular ejection fraction 58 ± 12%) undergoing right heart catheterization and upright CXR prior to aortic valve replacement (AVR). Two radiologist independently evaluated all CXR for the presence of bilateral PE, unilateral, or no PE, blinded to any other data. There were 49 (10%) patients with bilateral PE, 32 (7%) patients with unilateral PE, and 390 (83%) patients with no PE. Patients with bilateral PE had the highest mean right atrial pressure, mean pulmonary artery wedge pressure (mPAWP), and pulmonary vascular resistance, and had the lowest stroke volume index while those with unilateral PE had intermediate values. In the multivariate analysis, mPAWP was an independent predictor of any PE and bilateral PE. After a median (interquartile range) post-AVR follow-up of 1361 (957-1878) days mortality was highest in patients with bilateral PE (2.7 times higher than in patients without PE), whereas patients with unilateral PE had similar mortality as those without PE. CONCLUSIONS: In severe AS patients, the presence of PE, particularly bilateral PE, is a marker of a poor haemodynamic constellation. Bilateral PE is associated with a substantially increased post-AVR mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Derrame Pleural , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Volumen Sistólico/fisiología , Estenosis de la Válvula Aórtica/cirugía , Función Ventricular Izquierda , Hemodinámica/fisiología , Pronóstico , Derrame Pleural/complicaciones , Derrame Pleural/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA