Resultados 1 - 13 de 13
Filtrar
1.
J Med Virol ; 93(10): 5783-5788, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34050945

RESUMEN

More and more rapid antigen tests for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) appear in the market with varying performance. The sensitivity of these tests heavily depends on the viral load, extrapolated by the threshold cycle (Ct). It is therefore essential to verify their performance before their inclusion in routine. The Coronavirus Ag Rapid Test Cassette Bio-Rad, the GSD NovaGen SARS-CoV-2 (COVID-19) Antigen Rapid Test, and the Aegle Coronavirus Ag Rapid Test Cassette were evaluated on 199 samples: 150 fresh samples from the routine and positive in quantitative reverse-transcription polymerase chain reaction (RT-qPCR), nine fresh samples negative in RT-qPCR, and 40 frozen samples, taken before the discovery of SARS-CoV-2 but positive for other respiratory viruses. Positive RT-qPCR samples were categorized according to their Ct: Ct < 20 (18.7%), ≥ 20-< 25 (27.3%), ≥ 25-< 30 (18.7%), ≥ 30-35 (17.3%), and > 35 (18.0%). Sensitivities (95% confidence interval) for Ct below 25 were 95.7% (92.4-98.9), 97.1% (94.4-99.8), and 97.1% (94.4-99.8) for GSD NovaGen, Bio-Rad, and Aegle, respectively but drastically dropped when Ct exceeded 27. Among samples with previously diagnosed viruses, seven false-positive results were found with GSD NovaGen only (specificity 85.7%). Equivalent, high sensitivities were observed with the highest viral load samples. The GSD NovaGen assay showed less specificity. Although the three kits tested in this study are inadequate for routine testing in a high throughput laboratory, they can help to quickly identify the most infectious patients and screen their close contacts in an environment where molecular tests are not readily available.


Asunto(s)
Prueba Serológica para COVID-19 , COVID-19/diagnóstico , Pruebas en el Punto de Atención , SARS-CoV-2/aislamiento & purificación , Carga Viral , Antígenos Virales/análisis , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/estadística & datos numéricos , Humanos , ARN Viral/análisis , ARN Viral/genética , SARS-CoV-2/genética , SARS-CoV-2/inmunología , Sensibilidad y Especificidad
2.
J Med Virol ; 93(2): 803-811, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32667733

RESUMEN

The development of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serological tests is massive. The external validation of their performance is needed before use in clinical routine practice. Our study aims at assessing the analytical and clinical performance of two enzyme-linked immunosorbent assay tests detecting antibodies directed against the virus nucleocapsid protein: The NovaLisa SARS-CoV-2 immunoglobulin G (IgG), immunoglobulin A (IgA), and immunoglobulin M (IgM) test (NovaTec) allowing a separate detection of each antibody and the Platelia SARS-CoV-2 Total Ab test (Bio-Rad) detecting total antibodies (IgM, IgA, and IgG). Two-hundred and eight coronavirus disease 2019 samples from 48 quantitative reverse transcription-polymerase chain reaction (RT-qPCR) confirmed patients were used to perform the sensitivity analysis. Non-SARS-CoV-2 sera (n = 79) with a potential cross-reaction to SARS-CoV-2 immunoassays were included in the specificity analysis. In addition, using receiver operator characteristic curves, adapted cut-off for improvement of the performances were proposed. The kinetics of these antibodies was also assessed over 8 weeks. Two weeks after the RT-qPCR positive detection, the NovaLisa test shows a sensitivity and specificity of 94.9% (95% confidence interval [CI]: 83.1%-98.6%) and 96.2% (95% CI: 89.4%-98.7%) for IgG, of 89.7% (95% CI: 76.4%-95.9%) and 98.7% (95% CI: 93.2%-98.8%) for IgA, and of 48.7% (95% CI: 33.9%-63.8%) and 98.7% (95% CI: 93.2%-99.8%) for IgM. With the Platelia system, the specificity and sensitivity were 97.4% (95% CI: 92.1%-99.7%) and 94.9% (95% CI: 87.7%-98.0%) for total antibodies using the adapted cut-offs. The NovaLisa and the Platelia tests have satisfactory analytical performances. The clinical performances are excellent for IgG, IgA, and total antibodies especially if the cut-off is optimized.


Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/diagnóstico , Ensayo de Inmunoadsorción Enzimática/normas , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , SARS-CoV-2/inmunología , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/inmunología , COVID-19/mortalidad , COVID-19/virología , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2/patogenicidad , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Análisis de Supervivencia
3.
Clin Chem Lab Med ; 58(8): 1357-1364, 2020 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-32447328

RESUMEN

Objectives Faced with the COVID-19 pandemic and its impact on the availability and quality of both therapeutic and diagnostic methods, the Belgian authorities have decided to launch a procedure for additional evaluation of the performance of serological tests offered for sale on the national territory. This has been proposed with a double aim: (1) an in-depth verification of the analytical and clinical performances presented by the manufacturer and (2) an economy of scale in terms of centralized validation for all the laboratories using the tests subject to evaluation. Methods A retrospective validation study was conducted including the serum of 125 patients in order to determine the analytical and clinical performances of the LIAISON®SARS-CoV-2 from DiaSorin® detecting anti-SARS-CoV-2 IgG and to compare its clinical performance with the enzyme-linked immunosorbent assay (ELISA) test from Euroimmun®, one of the first commercially available tests allowing the detection of anti-SARS-CoV-2 IgA and IgG. Results The performances of the LIAISON®SARS-CoV-2 satisfied all the acceptance criteria and provided "real world" analytical and clinical performances very close to the ones reported by the manufacturer in its insert kit. Comparison between the LIAISON®SARS-CoV-2 and the ELISA method did not reveal any difference between the two techniques in terms of sensitivities and specificities regarding the determination of the IgG. Conclusions This study reports the validation of the LIAISON®SARS-CoV-2 allowing to detect IgG antibodies specifically directed against SARS-CoV-2. The analytical and clinical performances are excellent, and the automation of the test offers important rates, ideal for absorbing an extension of testing.


Asunto(s)
Anticuerpos Antivirales/inmunología , Betacoronavirus/inmunología , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Inmunoensayo/métodos , Neumonía Viral/diagnóstico , COVID-19 , Prueba de COVID-19 , Infecciones por Coronavirus/inmunología , Humanos , Límite de Detección , Luminiscencia , Mediciones Luminiscentes/métodos , Pandemias , Neumonía Viral/inmunología , Reproducibilidad de los Resultados , Estudios Retrospectivos , SARS-CoV-2
4.
Virology ; 595: 110082, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38636363

RESUMEN

Vaccines against SARS-CoV-2 were developed during the pandemic including the BNT162b2 and the mRNA-1273. We evaluated the levels of binding antibodies against the receptor binding domain and the levels of NAbs in individuals who developed a breakthrough infection after having received three doses of mRNA-1273. A total of 51 participants were included. The breakthrough group was compared to a 1:1 matched-control group. Among the 51 individuals, 18 (35%) developed a breakthrough infection. The GMT of NAbs against the BA.1 in the BK population was 278.1 (95%CI: 168.1-324.1). This titer was significantly lower compared to the matched-control group when considering all data (GMT = 477.4; 95%CI: 316.2-541.0; p = 0.0057). Results were similar for the BA.5 (GMT = 152.0 (95%CI: 76.9-172.9) for breakthrough and 262.0 (95%CI: 171.3-301.8) for control (p = 0.0043)). Our study found that individuals receiving the mRNA-1273 booster and who developed a breakthrough infection presented lower levels of binding antibodies and NAbs before the infection as compared to a matched-control group.


Asunto(s)
Vacuna nCoV-2019 mRNA-1273 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Vacunas contra la COVID-19 , COVID-19 , Personal de Salud , Inmunización Secundaria , SARS-CoV-2 , Humanos , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/sangre , Vacuna nCoV-2019 mRNA-1273/inmunología , Vacuna nCoV-2019 mRNA-1273/administración & dosificación , COVID-19/inmunología , COVID-19/virología , COVID-19/prevención & control , Anticuerpos Antivirales/inmunología , Anticuerpos Antivirales/sangre , SARS-CoV-2/inmunología , SARS-CoV-2/genética , Masculino , Femenino , Adulto , Vacunas contra la COVID-19/inmunología , Vacunas contra la COVID-19/administración & dosificación , Persona de Mediana Edad , Vacuna BNT162/administración & dosificación , Vacuna BNT162/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Glicoproteína de la Espiga del Coronavirus/genética , Infección Irruptiva
5.
Heliyon ; 10(16): e36116, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39247272

RESUMEN

Introduction: Some studies suggest that the monovalent mRNA-1273 vaccine is more effective than BNT162b2 in producing higher levels of antibodies. However, limited data are available, and the methods used are not directly comparable. Material and methods: Blood samples were obtained before the booster (third dose) and after 14, 90, and 180 days in two similar cohorts who received the original BNT162b2 or mRNA-1273 vaccine designed to target wild type SARS-CoV-2. The aim of our study is to compare their effectiveness by assessing the levels of binding and neutralizing antibodies specifically against each of the BA.1 variant, BA.5 variant, and the XBB.1.5 subvariant. Results: Once the peak was reached after two weeks, a drastic decline in binding and neutralizing antibodies was observed up to 6 months after the homologous booster administration. The humoral response was however more sustained with the mRNA-1273 booster, with half-lives of 167, 55, and 48 days for binding, BA.1, and BA.5 neutralizing antibodies compared to 144, 30, and 29 days for the BNT162b2 booster, respectively. Compared to the BA.1 variant, the neutralizing capacity was significantly decreased at 6 months with the BA.5 variant (fold-decrease: 1.67 to 3.20) and the XBB.1.5. subvariant (fold-decrease: 2.86 to 5.48). Conclusion: Although the decrease in the humoral response was observed with both mRNA vaccines over time, a more sustained response was observed with the mRNA-1273 vaccine. Moreover, the emergence of Omicron-based variants causes a reduced neutralizing capacity, notably with the XBB.1.5. subvariant. The administration of subsequent boosters would therefore be needed to restore a sufficiently high neutralizing response.

6.
Eur J Clin Nutr ; 75(4): 689-696, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33033379

RESUMEN

BACKGROUND/OBJECTIVES: Iodine deficiency and excessive salt intakes have adverse health consequences. The objective was to measure sodium and iodine concentrations in urine spot samples among a representative sample of Belgian adults and compare those to World Health Organization (WHO) recommendations. SUBJECTS/METHODS: Spot urine samples were collected in 2018 from participants of the Belgian Health Examination Survey. Iodine and sodium concentrations were measured by inductively coupled plasma mass spectrometry and ion selective electrodes respectively. Tanaka and INTERSALT equations were used to predict 24-h urinary sodium excretion using sodium and creatinine concentration in spot samples, sex, and measured height and weight. RESULTS: Median urinary iodine concentration (UIC) among adults (n = 1092) was 93.6 µg/L, indicating mild iodine deficiency according to WHO thresholds. Median UIC among participants who reported thyroid problems over the last year was significantly higher than among those who did not report thyroid problems (104.1 µg/L versus UIC = 92.2 µg/L, p < 0.001). There were no significant differences in median UIC between sexes, age groups, and regions. The average salt intake among Belgian adults (n = 1120) was 8.3 ± 0.1 g/day using the Tanaka equation and 9.4 ± 0.1 g/day using the INTERSALT equation. For both equations, <5% of the population met the recommended WHO upper salt intake level of 5 g/day. CONCLUSIONS: Iodine nutrition in the Belgian adult, nonpregnant population likely indicates mild iodine deficiency as the median UIC was below the WHO threshold for iodine sufficiency. Salt intake was substantially higher than the WHO recommendations. Further policy efforts are needed to optimize iodine and reduce salt intake in Belgium.


Asunto(s)
Yodo , Adulto , Bélgica/epidemiología , Estudios Transversales , Humanos , Yodo/análisis , Estado Nutricional , Sodio , Cloruro de Sodio Dietético
7.
J Infect ; 83(5): 559-564, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34437927

RESUMEN

OBJECTIVES: Scarce data are currently available on the kinetics of antibodies after vaccination with mRNA vaccines as a whole and, with mRNA-1273, in particular. We report here an ad-interim analysis of data obtained after a 6-month follow-up in a cohort of healthcare workers (HCWs) who received the mRNA-1273 vaccine. These new data provide more insight into whether and in whom a 3rd dose could be necessary. METHODS: Our study compared the anti-S antibody kinetics at 2 weeks (T1), 3 months (T3) and 6 months (T4) after the first injection, and 2 weeks after the second injection (T2). The 201 participating HCWs were stratified according to their initial serological status. The vaccine effectiveness was also assessed through a medical questionnaire. RESULTS: We report here a marked and statistically significant antibody decrease (P < 0.05) between T3 and T4, especially in naïve vaccinees. The analysis of potential confounding factors or known risk factors for severe COVID-19 disease did not reveal any influence on the drop observed. Six-month after vaccination, only one, symptomatic, infection was reported in our cohort. CONCLUSIONS: In a supply-limited environment, our results plead for reserving the 3rd dose scheme, in the upcoming months, to seronegative individuals prior to vaccination, especially when the serological status is easily accessible.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Vacuna nCoV-2019 mRNA-1273 , Anticuerpos Antivirales , Personal de Salud , Humanos , Inmunogenicidad Vacunal , ARN Mensajero , SARS-CoV-2
8.
J Clin Virol ; 129: 104472, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32504944

RESUMEN

BACKGROUND: The COVID-19 Ag (Antigen) Respi-Strip assay is a new immunochromatographic diagnostic tool recently available for antigenic diagnosis of SARS-CoV-2. The proposed sensitivity is not higher than 60 %, but its high specificity allows both quick decisions for the management of patients and confirmation by molecular diagnosis for only negative tests. However, from the first tests performed, we suspected that the sensitivity observed with routine use was much lower than that announced by the manufacturer. MATERIALS AND METHODS: Over a period of one month, we compared the negative results obtained with the COVID-19 Ag Respi-Strip kit with those obtained from qRT-PCR performed in a laboratory qualified for the molecular diagnosis of SARS-CoV-2. All samples tested were naso-pharyngeal smears from UTM-RT medium. RESULTS: Of 774 patients tested, 714 negative samples were sent for confirmation, and 159 were found to be positive by qRT-PCR. The median positive percentage agreement was 23.9 % (95 % CI: 14.2 %-38.2 %). The Cohen's kappa score was 0.35. CONCLUSION: Using this immunochromatographic assay as a triage test did not significantly reduce the number of samples outsourced for COVID-19 confirmation by qRT-PCR. In addition, even if the turn-around time is short, the assay is completely manual, which is not suitable for large volumes of routine samples. The sensitivity of this rapid test is poor, and improvements are needed to enhance its performance.

SELECCIÓN DE REFERENCIAS