RESUMEN
The presence of donor-specific anti-HLA antibodies (DSAs) is associated with increased risk of graft failure after kidney transplant. We hypothesized that DSAs against HLA class I, class II, or both classes indicate a different risk for graft loss between deceased and living donor transplant. In this study, we investigated the impact of pretransplant DSAs, by using single antigen bead assays, on long-term graft survival in 3237 deceased and 1487 living donor kidney transplants with a negative complement-dependent crossmatch. In living donor transplants, we found a limited effect on graft survival of DSAs against class I or II antigens after transplant. Class I and II DSAs combined resulted in decreased 10-year graft survival (84% to 75%). In contrast, after deceased donor transplant, patients with class I or class II DSAs had a 10-year graft survival of 59% and 60%, respectively, both significantly lower than the survival for patients without DSAs (76%). The combination of class I and II DSAs resulted in a 10-year survival of 54% in deceased donor transplants. In conclusion, class I and II DSAs are a clear risk factor for graft loss in deceased donor transplants, while in living donor transplants, class I and II DSAs seem to be associated with an increased risk for graft failure, but this could not be assessed due to their low prevalence.
Asunto(s)
Selección de Donante , Rechazo de Injerto/mortalidad , Antígenos HLA/inmunología , Isoanticuerpos/efectos adversos , Fallo Renal Crónico/cirugía , Trasplante de Riñón/mortalidad , Donadores Vivos , Adulto , Cadáver , Femenino , Estudios de Seguimiento , Rechazo de Injerto/etiología , Rechazo de Injerto/patología , Supervivencia de Injerto , Humanos , Trasplante de Riñón/efectos adversos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Tasa de SupervivenciaRESUMEN
Solid-phase multiplex-bead assays are widely used in transplantation to detect anti-human leukocyte antigen (HLA) antibodies. These assays enable high resolution detection of low levels of HLA antibodies. However, multiplex-bead assays are costly and yield variable measurements that limit the comparison of results between laboratories. In the context of a Dutch national Consortium study we aimed to determine the inter-assay and inter-machine variability of multiplex-bead assays, and we assessed how to reduce the assay reagents costs. Fifteen sera containing a variety of HLA antibodies were used yielding in total 7092 median fluorescence intensities (MFI) values. The inter-assay and inter-machine mean absolute relative differences (MARD) of the screening assay were 12% and 13%, respectively. The single antigen bead (SAB) inter-assay MARD was comparable, but showed a higher lot-to-lot variability. Reduction of screening assay reagents to 50% or 40% of manufacturers' recommendations resulted in MFI values comparable to 100% of the reagents, with an MARD of 12% or 14%, respectively. The MARD of the 50% and 40% SAB assay reagent reductions were 11% and 22%, respectively. From this study, we conclude that the reagents can be reliably reduced at least to 50% of manufacturers' recommendations with virtually no differences in HLA antibody assignments.