Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Clin Transl Oncol ; 18(5): 480-8, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26311079

RESUMEN

PURPOSE: To identify the main difficulties in postoperative clinical target volume (CTV) delineation in gastric cancer (GC). METHODS: Before and after a training course, 20 radiation oncology residents were asked to delineate the CTV for the postoperative GC case on four computed tomography scans: dome of the diaphragm, anterior abdominal wall, duodenal stump and porta hepatis level, and to determine the lower CTV border. CTV volume was reconstructed from requested planar contours. Area of intersection (AI) for each requested scan and volume of intersection (VI), defined as the overlap of delineated area/volume with respective reference area (RA)/reference volume (RV) proposed by the senior radiation oncologist, were computed. The degree of agreement between the reference and participants' contours was quantified using the Concordance Index (CI): AI/RA × 100% or VI/RV × 100%. The lower CTV border was analyzed separately. Pre- and post-training CIs were compared. A questionnaire investigated the difficulties with contouring. RESULTS: Mean CI value was the lowest for the dome of the diaphragm (24% pre-training, 35 % post-training) and for the duodenal stump (49% pre-training, 61% post-training). Mean CI for the CTV volume was 49% pre-training and 59% post-training, p = 0.39. Mean distance from the reference to the participants' lower CTV borders was 2.73 cm pre-training and 2.0 cm post-training, p = 0.71. In a questionnaire, 75% of respondents indicated the elective nodal area as the main difficulty. CONCLUSIONS: Delineation of the dome of the diaphragm and the duodenal stump, as yet not recognized as the source of variation, should be addressed in the international consensus guidelines and clarified.


Asunto(s)
Adenocarcinoma/patología , Variaciones Dependientes del Observador , Guías de Práctica Clínica como Asunto/normas , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Gástricas/patología , Adenocarcinoma/radioterapia , Adenocarcinoma/cirugía , Gastrectomía , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Cuidados Posoperatorios , Pronóstico , Dosificación Radioterapéutica , Neoplasias Gástricas/radioterapia , Neoplasias Gástricas/cirugía , Carga Tumoral
2.
Radiat Prot Dosimetry ; 162(1-2): 38-42, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24993011

RESUMEN

In the present study, bone samples from three patients treated in radiotherapy facilities in Poland were used for the determination of doses absorbed during radiotherapy. The samples were obtained during surgical treatments of patients performed due to medical indications. For the purpose of retrospective dosimetry, sensitivity of the radiation-induced EPR signal was individually calibrated in the samples by re-irradiation of the samples with known doses. The doses reconstructed in bones extracted within 6 months after irradiation were consistent with those calculated by treatment planning systems. The dose reconstructed in the bone removed 6 y after radiotherapy was ∼14% lower than the calculated one.


Asunto(s)
Neoplasias Óseas/radioterapia , Huesos/efectos de la radiación , Espectroscopía de Resonancia por Spin del Electrón/métodos , Radiometría/métodos , Neoplasias Óseas/secundario , Humanos , Neoplasias de los Labios/patología , Neoplasias de los Labios/radioterapia , Neoplasias de la Boca/patología , Neoplasias de la Boca/radioterapia , Dosificación Radioterapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA