Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Clin Oral Investig ; 23(1): 509, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30543024

RESUMEN

The following note was inadvertently omitted from the published paper: This work was performed in (partial) fulfillment of the requirements for the first author's obtaining the degree Dr. med. dent.

2.
Clin Oral Investig ; 22(4): 1625-1630, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29572686

RESUMEN

OBJECTIVES: This study aimed to identify anatomical areas where resections of oral squamous cell carcinomas (OSCC) are significantly associated with close or positive margins. MATERIALS AND METHODS: This retrospective study included 330 patients with a primary OSCC from 2010 to 2015. Patient and tumour data were categorised into three groups by R-status (R0 [clear], ≥ 5 mm, 185 patients [56.06%]; R1 [positive], < 1 mm, 24 patients [7.27%]; and R0 [close], 1-5 mm, 121 patients [36.67%]). RESULTS: Areas where resections were significantly associated with close or positive margins were the hard palate (p < 0.001), buccal mucosa (p = 0.03), floor of the mouth (p = 0.004), lower alveolar ridge (p = 0.01), retromolar triangle (p = 0.005), and dorsal tongue (p = 0.02). CONCLUSIONS: Anatomical areas were identified in the oral cavity where it is challenging to resect OSCCs with an adequate safety margin. CLINICAL RELEVANCE: These results may enable surgeons to achieve a postulated safe distance during tumour resection, leading to a survival benefit for patients.


Asunto(s)
Carcinoma de Células Escamosas/cirugía , Márgenes de Escisión , Neoplasias de la Boca/cirugía , Puntos Anatómicos de Referencia , Carcinoma de Células Escamosas/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias de la Boca/patología , Clasificación del Tumor , Estadificación de Neoplasias , Estudios Retrospectivos
3.
J Biomed Mater Res B Appl Biomater ; 108(4): 1295-1303, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31444960

RESUMEN

Total joint replacement implants are generally designed to physically mimic the biological environment to ensure compatibility with the host tissue. However, implant instability exposes patients to long recovery periods, high risk for revision surgeries, and high expenses. Introducing electrical stimulation to the implant site to accelerate healing is promising, but the cumbersome nature of wired devices is detrimental to the implant design. We propose a novel strategy to stimulate cells at the implant site by utilizing piezoelectric ceramics as electrical stimulation sources. The inherent ability of these materials to form electric surface potentials under mechanical load allows them to act as internal power sources. This characteristic is commonly exploited in non-biomedical applications such as transducers or sensors. We investigate calcium/zirconium-doped barium titanate (BCZT) ceramics in an in vitro environment to determine their potential as implant materials. BCZT exhibits low cytotoxicity with human osteoblast and endothelial cells as well as high piezoelectric responses. Microstructural adaptation was identified as a route for optimizing piezoelectric behavior. Our results show that BCZT is a promising system for biomedical applications. Its characteristic ability to autonomously generate electric surface potentials opens the possibility to functionalize existing bone replacement implant designs to improve implant ingrowth and long-term stability.


Asunto(s)
Materiales Biocompatibles , Sustitutos de Huesos , Cerámica , Células Endoteliales/metabolismo , Osteoblastos/metabolismo , Bario/química , Bario/farmacología , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Sustitutos de Huesos/química , Sustitutos de Huesos/farmacología , Calcio/química , Calcio/farmacología , Cerámica/química , Cerámica/farmacología , Humanos , Titanio/química , Titanio/farmacología , Circonio/química , Circonio/farmacología
4.
J Craniomaxillofac Surg ; 47(1): 53-59, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30470467

RESUMEN

BACKGROUND: Various causes for bone defects of the lower jaw have been described. As a result, patients often suffer from compromised aesthetics and a loss of, or reduction in, important physiological functions, such as swallowing, breathing, and speaking. A change in the shape of the lower jaw can impair the natural occlusion and leads to an atypical or modified position of the temporomandibular joint. Titanium reconstruction plates are the standard approach to jaw reconstruction, and are used for temporary bridging of a jaw defect or fixation of a bone graft. Conventionally these plates are intraoperatively adjusted to the mandible by the surgeon. Computer-aided manufacturing, computer-aided design, and rapid prototyping have gained increasing importance in the field of medicine, as they allow the production of individual models of the lower jaw, with the possibility of preoperatively bending the reconstruction plates. In this retrospective study, the accuracy of pre-bent titanium plates and their effect on the temporomandibular joint situation in comparison with intraoperatively curved plates will be discussed. MATERIALS AND METHODS: Patients who attended our department for lower jaw reconstruction between March 2013 and February 2015 were included in this retrospective study. Within that time 20 patients were treated with pre-bent reconstruction plates (group 1). 20 comparable patients were selected with reconstruction and conventional intraoperative bending (group 2). To evaluate the accuracy of the plates and the condylar position, postoperative cone beam computed tomograms and computed tomograms were used to assess the bone-plate distance at 12 defined points and four angles in axial reconstruction. The results were compared, statistically evaluated, and discussed. RESULTS: Regarding the maximum bone-plate distances and the sum of distances, there was a significant difference between the accuracy of the pre-bent and the conventionally bent reconstruction plates (p = 0.022, p = 0.048). Regarding the condylar position, there was no significant difference between both methods (p = 0.867). CONCLUSION: The results of this study show that a better fitting accuracy can be achieved using pre-bent plates. Preparation of the plates proves to be advantageous and meaningful, especially in complex bone defects and deformations of the lower jaw. Nevertheless, concerning the position of the temporomandibular joint, no significant difference could be ascertained between the shown methods, contradicting several studies.


Asunto(s)
Placas Óseas , Mandíbula/cirugía , Reconstrucción Mandibular/métodos , Procedimientos de Cirugía Plástica/métodos , Articulación Temporomandibular/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Trasplante Óseo , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico , Estética Dental , Femenino , Humanos , Masculino , Mandíbula/diagnóstico por imagen , Cóndilo Mandibular/diagnóstico por imagen , Cóndilo Mandibular/cirugía , Persona de Mediana Edad , Osteotomía/métodos , Impresión Tridimensional , Ajuste de Prótesis , Estudios Retrospectivos , Cirugía Asistida por Computador/métodos , Colgajos Quirúrgicos , Articulación Temporomandibular/diagnóstico por imagen , Titanio , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
J Craniomaxillofac Surg ; 46(8): 1167-1171, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29884310

RESUMEN

INTRODUCTION: Magnetic resonance imaging has been established as the gold standard for assessment of the temporomandibular joint. Apart from an excellent assessment of the soft tissues it has the advantage not to expose the patient to ionizing radiation. There is a lack of literature concerning the correlation between pain intensity and radiological findings of the temporomandibular joint. Moreover there is the question of whether a progressive degeneration of the cartilaginous components is accompanied by an increasing degeneration of the osseous parts of the mandibular joint and vice versa. Therefore, this study aims at analyzing correlations between pain and radiological findings. Furthermore, the link between osseous and cartilaginous degeneration is studied. MATERIALS AND METHODS: 91 patients who attend our outpatient clinic for temporomandibular disorders are included in this prospective study. Apart from a detailed anamnesis and clinical examination - adapted to the Research Diagnostic Criteria for Temporomandibular Disorders -magnetic resonance imaging of both mandibular joints is performed. Pain intensity is measured using the visual analog scale. To assess and grade the radiological findings a classification system is established. The evaluation of the osseous components is based on the classification of osteoarthritis by Kellgren and Lawrence whereas the rating of the cartilaginous components is adapted to the Research Diagnostic Criteria for Temporomandibular Disorders. Correlations are verified by Spearman-Rho. RESULTS: 83,5% of all patients are female. Most of the time, both sides are affected (47.25%). Women state an average pain of 5.7 (±2.4), men 3.5 (±2.5). 182 discs are examined and assessed with our classification system. Most discs (n = 71) show no pathological changes. The majority of patients show no dislocation (n = 104). The most common forms of dislocation are anterior dislocations (n = 51). The majority of patients show no changes in the osseous component (n = 115). Weak to moderate correlations are found between disc and bone degeneration. Moderate to strong correlations are found between left and right TMJ. CONCLUSIONS: The classification system which is designed and applied during the study proves to be a reliable and practical Instrument. A standardized evaluation of pathologies concerning the temporomandibular joint is possible by using this system. Numerous patients attending our outpatient clinic do not show any signs of degenerative dysfunctions in the mandibular joints. Degenerations of the osseous components tend to be connected with degenerations of the cartilaginous components and vice versa. The question remains if in the future new procedures in imaging will be able to record pathologies not yet detected.


Asunto(s)
Dolor Facial/diagnóstico por imagen , Trastornos de la Articulación Temporomandibular/diagnóstico por imagen , Adulto , Dolor Facial/etiología , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Dimensión del Dolor , Estudios Prospectivos , Factores Sexuales , Articulación Temporomandibular/diagnóstico por imagen , Disco de la Articulación Temporomandibular/diagnóstico por imagen , Trastornos de la Articulación Temporomandibular/complicaciones
6.
J Biol Eng ; 11: 29, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28919925

RESUMEN

BACKGROUND: With additive manufacturing (AM) individual and biocompatible implants can be generated by using suitable materials. The aim of this study was to investigate the biological effects of polylactic acid (PLA) manufactured by Fused Deposition Modeling (FDM) on osteoblasts in vitro according to European Norm / International Organization for Standardization 10,993-5. METHOD: Human osteoblasts (hFOB 1.19) were seeded onto PLA samples produced by FDM and investigated for cell viability by fluorescence staining after 24 h. Cell proliferation was measured after 1, 3, 7 and 10 days by cell-counting and cell morphology was evaluated by scanning electron microscopy. For control, we used titanium samples and polystyrene (PS). RESULTS: Cell viability showed higher viability on PLA (95,3% ± 2.1%) than in control (91,7% ±2,7%). Cell proliferation was highest in the control group (polystyrene) and higher on PLA samples compared to the titanium samples. Scanning electron microscopy revealed homogenous covering of sample surface with regularly spread cells on PLA as well as on titanium. CONCLUSION: The manufacturing of PLA discs from polylactic acid using FDM was successful. The in vitro investigation with human fetal osteoblasts showed no cytotoxic effects. Furthermore, FDM does not seem to alter biocompatibility of PLA. Nonetheless osteoblasts showed reduced growth on PLA compared to the polystyrene control within the cell experiments. This could be attributed to surface roughness and possible release of residual monomers. Those influences could be investigated in further studies and thus lead to improvement in the additive manufacturing process. In addition, further research focused on the effect of PLA on bone growth should follow. In summary, PLA processed in Fused Deposition Modelling seems to be an attractive material and method for reconstructive surgery because of their biocompatibility and the possibility to produce individually shaped scaffolds.

7.
J Craniomaxillofac Surg ; 43(10): 2129-35, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26498514

RESUMEN

Diagnostic imaging of head and neck cancer has made enormous progress during recent years. Next to morphological imaging modalities (computed tomography [CT] and magnetic resonance imaging [MRI]), there are also hybrid imaging systems that combine functional and morphological information (positron emission tomography [PET]/CT and PET/MRI). The aim of this study was to compare the diagnostic accuracy of PET/MRI in the diagnosis of head and neck cancer with other imaging modalities (MRI, CT, PET/CT). Ten patients (nine male and one female) with histologically proven oral squamous cell carcinoma participated in an 18 F-FDG-PET/CT scan and an additional 18 F-FDG PET/MRI scan prior to surgery. The morphological and functional results were compared with the histological results. Inclusion criteria were histologically proven oral squamous cell carcinoma and no prior surgical intervention, medical therapy, or local external radiation. There was no significant correlation between tumor differentiation and maximum standard uptake values. Functional imaging showed a slightly better correlation with the measurement of the maximal tumor diameter, whereas pure morphological imaging showed a better correlation with the measurement of infiltration depth. Only with PET/MRI could correct lymph node staging be reached; the other imaging tools showed false-negative or false-positive results. In conclusion, we showed in our limited patient cohort that PET/MRI is superior to the morphological imaging modalities, especially for lymph node staging.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neoplasias de la Boca/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Femenino , Humanos , Masculino , Proyectos Piloto , Radiofármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA