Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Allergy Asthma Proc ; 45(2): 108-111, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38449008

RESUMEN

Background: Atopic dermatitis (AD) is an inflammatory skin disease caused by allergen exposures and estimated to affect ∼20% of children. Children in urban areas have a higher prevalence of AD compared with those living outside of urban areas. AD is believed to lead to asthma development as part of the "atopic march." Objective: Our objective was to determine the sequential and chronological relationships between AD and asthma for children in an under-resourced community. Methods: The progression from AD to asthma in the under-resourced, urban community of Sun Valley, Colorado, was examined by assessing Medicaid data for the years 2016 to 2019 for a diagnosis of AD or asthma in children 6 and 7 years old. Results: Pearson correlations between AD and asthma diagnoses were significant only with respect to AD at age 6 years compared with asthma 1 year later, at age 7 years. Conclusion: By studying a susceptible community with a consistent but mixed genetic background, we found sequential and chronological links between AD and asthma.


Asunto(s)
Asma , Dermatitis Atópica , Niño , Estados Unidos/epidemiología , Humanos , Dermatitis Atópica/diagnóstico , Dermatitis Atópica/epidemiología , Asma/epidemiología , Asma/etiología , Ambiente , Recursos en Salud
2.
J Asthma ; 60(3): 479-486, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35341426

RESUMEN

OBJECTIVE: The School Inner-City Asthma Intervention Study 2 (SICAS 2) tested interventions to reduce exposures in classrooms of students with asthma. The objective of this post-hoc analysis was limited to evaluating the effect of high-efficiency particulate (HEPA) filtration interventions on mold levels as quantified using the Environmental Relative Moldiness Index (ERMI) and the possible improvement in the students' asthma, as quantified by spirometry testing. METHODS: Pre-intervention dust samples were collected at the beginning of the school year from classrooms and corresponding homes of students with asthma (n = 150). Follow-up dust samples were collected in the classrooms at the end of the HEPA or Sham intervention. For each dust sample, ERMI values and the Group 1 and Group 2 mold levels (components of the ERMI metric) were quantified. In addition, each student's lung function was evaluated by spirometry testing, specifically the percentage predicted forced expiratory volume at 1 sec (FEV1%), before and at the end of the intervention. RESULTS: For those students with a higher Group 1 mold level in their pre-intervention classroom than home (n = 94), the FEV1% results for those students was significantly (p < 0.05) inversely correlated with the Group 1 level in their classrooms. After the HEPA intervention, the average Group 1 and ERMI values were significantly lowered, and the average FEV1% test results significantly increased by an average of 4.22% for students in HEPA compared to Sham classrooms. CONCLUSIONS: HEPA intervention in classrooms reduced Group 1 and ERMI values, which corresponded to improvements in the students' FEV1% test results.


Asunto(s)
Contaminación del Aire Interior , Asma , Humanos , Asma/terapia , Vivienda , Polvo/análisis , Hongos , Espirometría , Contaminación del Aire Interior/prevención & control , Contaminación del Aire Interior/análisis
3.
J Allergy Clin Immunol ; 149(4): 1481-1485, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34606833

RESUMEN

BACKGROUND: Mold sensitization and exposure are associated with asthma severity, but the specific species that contribute to difficult-to-control (DTC) asthma are unknown. OBJECTIVE: We sought to determine the association between overall and specific mold levels in the homes of urban children and DTC asthma. METHODS: The Asthma Phenotypes in the Inner-City study recruited participants, aged 6 to 17 years, from 8 US cities and classified each participant as having either DTC asthma or easy-to-control (ETC) asthma on the basis of treatment step level. Dust samples had been collected in each participant's home (n = 485), and any dust remaining (n = 265 samples), after other analyses, was frozen at -20oC. The dust samples (n = 265) were analyzed using quantitative PCR to determine the concentrations of the 36 molds in the Environmental Relative Moldiness Index. Logistic regression was performed to discriminate specific mold content of dust from homes of children with DTC versus ETC asthma. RESULTS: Frozen-dust samples were available from 54% of homes of children with DTC (139 of 253) and ETC asthma (126 of 232). Only the average concentration of the mold Mucor was significantly (P < .001) greater in homes of children with DTC asthma. In homes with window air-conditioning units, the Mucor concentration contributed about a 22% increase (1.6 odds ratio; 95% CI, 1.2-2.2) in the ability to discriminate between cases of DTC and ETC asthma. CONCLUSIONS: Mucor levels in the homes of urban youth were a predictor of DTC asthma, and these higher Mucor levels were more likely in homes with a window air-conditioner.


Asunto(s)
Contaminación del Aire Interior , Asma , Adolescente , Contaminación del Aire Interior/análisis , Alérgenos , Asma/epidemiología , Polvo/análisis , Hongos , Vivienda , Humanos , Población Urbana
4.
J Water Health ; 20(1): 205-215, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35100168

RESUMEN

Limited information exists on the environmental persistence of genetic markers for fecal indicator bacteria (FIB) in treated wastewaters. Here, the decay rate constants of culturable cells and genetic markers for four diverse groups of FIBs, such as enterococci, Clostridium, Escherichia coli, and Bacteroides, were investigated in freshwater microcosms seeded with disinfected and non-disinfected secondary-treated wastewaters. Decay rate constants of genetic markers and culturable cells varied significantly among the different FIB groups. Water temperatures (winter vs. fall/spring/summer) significantly affected the decay of all genetic marker and cell types; however, genetic marker decay were not found to be significantly different in disinfected (chlorination/ultraviolet) and non-disinfected wastewater-seeded microcosms or, for example, lake- and river-receiving waters. No evidence was seen that decay rate constants of FIB genetic markers from treated wastewater were substantially different from those observed in similar, previously reported microcosm studies using raw sewage. Unexpected relationships between decay rate constants of genetic markers and culturable cells of Bacteroides were observed. Results suggest that decay rate constants of FIB genetic markers determined from other studies may be applicable to treated wastewaters. Results of this study should be informative for ongoing efforts to determine the persistence of FIB genetic markers relative to surviving pathogens after wastewater treatment.


Asunto(s)
Bacterias , Purificación del Agua , Heces , Marcadores Genéticos/genética , Lagos
5.
J Occup Environ Hyg ; 18(1): 35-41, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33314963

RESUMEN

The Environmental Relative Moldiness Index (ERMI) is a scale created to compare mold contamination levels in U.S. homes. The ERMI was developed as a result of the Department of Housing and Urban Development's (HUD) first American Healthy Homes Survey (AHHS I), which sampled 1,096 homes selected to be representative of the U.S. housing stock. In AHHS I, a dust sample from each home was analyzed using quantitative PCR assays (qPCR) for 36 common indoor molds: 26 Group 1 molds, which were associated with water damage in homes and 10 Group 2 molds, which primarily enter the home from the outside environment. In 2019, HUD completed AHHS II by sampling 695 homes. Because lead was banned from paint in 1978, a larger proportion of homes selected for AHHS II had been built before 1978 compared to AHHS I. The 36 ERMI molds were analyzed in AHHS II exactly as in AHHS I. For the 36-ERMI molds, the rates of detection, average concentrations, and geometric means were in significant concordance (p < 0.001) between AHHS I and II, indicating that the ERMI methodology was stable over time. However, the average ERMI value in AHHS II homes was greater than in AHHS I. The reason for the difference was investigated by examining the Group 1 and 2 mold populations. The average summed logs of Group 1 molds were significantly greater in homes built before 1978 than the average for homes built later. Conversely, the average summed logs of Group 2 mold populations were the same in homes built before 1978 and homes built later. Since the summed logs of Group 2 mold is subtracted from the summed logs of Group 1 molds in the ERMI calculation, the average ERMI value was higher in AHHS II homes than AHHS I. In conclusion, by using the ERMI metric, we were able to demonstrate that water damage and mold growth were more likely to occur as homes get older.


Asunto(s)
Polvo/análisis , Hongos/aislamiento & purificación , Vivienda/estadística & datos numéricos , Monitoreo del Ambiente/métodos , Hongos/clasificación , Reacción en Cadena de la Polimerasa/métodos , Estados Unidos , Agua
6.
J Occup Environ Hyg ; 18(9): 423-429, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34170214

RESUMEN

The Environmental Relative Moldiness Index (ERMI) is a scale used to compare mold contamination levels in U.S. homes. To create the ERMI scale, a nationally representative set of U.S. homes was selected (n = 1,096). From each of these homes, a standard vacuum-dust sample was collected and then 36 common molds, the 26 Group 1 and 10 Group 2 molds, as grouped for forming the ERMI metric, were quantified using quantitative PCR assays. However, in investigations of mold in homes, it is not always practical or even possible to collect dust using the standard vacuum method. Therefore, we performed a comparative study of dust samples collected in the same homes (n = 151) by the standard vacuum method and by an electrostatic cloth (EC) method. First, floor dust was collected by vacuuming a 2 m2 area in the living room and a 2 m2 area in a bedroom, directly adjacent to the sofa or bed, for 5 min each with a Mitest sampler-fitted vacuum. Second, immediately after the collection of the vacuum dust sample, an EC dust sample was collected by wiping above-floor horizontal surfaces in the living room and bedroom. Then, the ERMI analysis of each sample was performed by a commercial laboratory. The results showed the average concentrations of 33 of the 36 ERMI molds were not significantly different in the vacuum and EC samples. Also, the average summed logs of the Group 1 molds, Group 2, or ERMI values were significantly (p < 0.001) correlated between the vacuum and EC samples. Logistic regression indicated that an EC sample could identify homes in the highest ERMI quartile 96% of the time by using the same ERMI value cutoff as vacuum sample ERMI value cutoff and 35% of samples proved to be false positives. When it is not practical to obtain the standard vacuum-dust sample, an EC sample can provide a useful practical alternative for ERMI analyses.


Asunto(s)
Contaminación del Aire Interior , Polvo , Contaminación del Aire Interior/análisis , Polvo/análisis , Hongos , Vivienda , Electricidad Estática , Vacio
7.
J Occup Environ Hyg ; 15(1): 38-43, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29053934

RESUMEN

The goal of this study was to evaluate the possible use of the Environmental Relative Moldiness Index (ERMI) to quantify mold contamination in multi-level, office buildings. Settled-dust samples were collected in multi-level, office buildings and the ERMI value for each sample determined. In the first study, a comparison was made between two identical four-story buildings. There were health complaints in one building but none in the other building. In the second study, mold contamination was evaluated on levels 6-19 of an office building with a history of water problems and health complaints. In the first study, the average ERMI value in the building with health complaints was 5.33 which was significantly greater than the average ERMI value, 0.55, in the non-complaint building. In the second study, the average ERMI values ranged from a low of -0.58 on level 8 to a high of 5.66 on level 17, one of the top five ranked levels for medical symptoms or medication use. The mold populations of ten (six Group 1 and four Group 2) of the 36-ERMI molds were in significantly greater concentrations in the higher compared to lower ERMI environments. The ERMI metric may be useful in the quantification of water-damage and mold growth in multi-level buildings.


Asunto(s)
Microbiología del Aire , Contaminación del Aire Interior/análisis , Polvo/análisis , Hongos/aislamiento & purificación , Monitoreo del Ambiente/métodos , Humanos , Agua
8.
J Asthma ; 54(3): 230-238, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27435833

RESUMEN

OBJECTIVE: To determine if there was a significant difference between mold contamination and asthma prevalence in Detroit and non-Detroit Michigan homes, between newer and older homes, and if there is a correlation between mold contamination and measures of Medicaid use for asthma in the 25 Detroit zip codes. METHODS: Settled dust was collected from homes (n = 113) of Detroit asthmatic children and from a representative group of Michigan homes (n = 43). The mold contamination for each home was measured using the Environmental Relative Moldiness Index (ERMI) scale and the mean ERMI values in Detroit and non-Detroit homes were statistically compared. Michigan Medicaid data (13 measures related to asthma) in each of the 25 zip codes in Detroit were tested for correlation to ERMI values for homes in those zip codes. RESULTS: The mean ERMI value (14.5 ± 8.0) for Detroit asthmatic childrens' homes was significantly (Student's t-test, p < 0.001) greater than the mean ERMI value (2.1 ± 6.2) for the non-Detroit homes. Detroit homes > 60 years old had significantly (p = 0.01) greater mean ERMI values than Detroit homes ≤ 60 years old (15.87 vs. 11.25). The percentage of children that underwent spirometry testing for their persistent asthma (based on Medicaid data) was significantly, positively correlated with the mean ERMI values of the homes in the 25 zip codes. CONCLUSIONS: Applying Medicaid-use data for spirometry testing and locating a city's older housing stock might help find foci of homes with high ERMI values.


Asunto(s)
Asma/epidemiología , Ambiente , Vivienda , Medicaid/estadística & datos numéricos , Polvo/análisis , Femenino , Hongos , Humanos , Masculino , Michigan , Prevalencia , Análisis de Área Pequeña , Espirometría , Estados Unidos
9.
Pediatr Allergy Immunol ; 26(1): 49-53, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25511604

RESUMEN

BACKGROUND: Mold exposures have been linked to the development and exacerbation of asthma. The purpose of this study was to determine whether the Environmental Relative Moldiness Index (ERMI) metric, developed to quantify mold exposures in homes, might be applied to evaluating the mold contamination in schools. METHODS: Settled dust samples (n = 10) were collected on each level of a water-damaged school in Springfield, Massachusetts and two samples per level in five Idaho schools. Each dust sample was analyzed for the 36 molds that make up the ERMI. The concentration of 2.5-µm particulate matter (PM2.5 ) was measured in each school at two locations during the spring of 2013. RESULTS: The average ERMI value in the Springfield school, 15.51, was significantly greater (p < 0.001) than the average ERMI value, -2.87, in the Idaho schools. Ten of the twenty-six Group 1 molds, which are associated with water-damaged environments, were in significantly greater concentrations in the Springfield school. The populations of Group 2 molds, which are common indoors even without water damage, were essentially the same in Springfield and Idaho schools. The average PM2.5 concentration in the Springfield and Idaho schools was 11.6 and 3.4 µg/m(3) , respectively. CONCLUSIONS: The ERMI scale might be useful in comparing the relative mold contamination in schools.


Asunto(s)
Asma/epidemiología , ADN de Hongos/análisis , Hongos/fisiología , Micosis/epidemiología , Instituciones Académicas/estadística & datos numéricos , Contaminación del Aire Interior/efectos adversos , Antígenos Dermatofagoides/inmunología , Polvo/inmunología , Exposición a Riesgos Ambientales/efectos adversos , Hospitalización/estadística & datos numéricos , Humanos , Idaho , Massachusetts , Material Particulado , Prevalencia
10.
J Water Health ; 12(3): 410-7, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25252344

RESUMEN

The US Environmental Protection Agency has proposed the use of quantitative polymerase chain reaction (qPCR) as a rapid alternative analytical method for monitoring recreational water quality at beaches. For qPCR to be considered for other Clean Water Act purposes, such as inclusion in discharge permits and use in Total Maximum Daily Load calculations, it is necessary to understand how qPCR detectable genetic markers are influenced by wastewater disinfection. This study investigated genetic markers for Escherichia coli, Enterococcus, Clostridium spp., Bacteroides, total Bacteroidales, as well as the human-associated Bacteroides markers, HF183 and HumM2, to determine which, if any, were influenced by disinfection (chlorination or ultraviolet light) of effluents from secondary wastewater treatment in different seasons. The effects of disinfection on culturable enterococci, E. coli, Bacteroides, and C. perfringens were also compared to their associated genetic markers. Disinfection of secondary treatment effluents significantly reduced culturable fecal indicator bacteria (FIB) but not genetic marker densities. No significant differences were observed in the responses of FIB culture and genetic marker densities to type of disinfection (chlorination vs UV) or season. Results of this study provide evidence that qPCR may not be suitable for monitoring efficacy of wastewater disinfection on the inactivation of bacterial pathogens.


Asunto(s)
Bacterias , Desinfección/normas , Heces/microbiología , Halogenación , Rayos Ultravioleta , Aguas Residuales/microbiología , Bacterias/efectos de los fármacos , Bacterias/genética , Bacterias/efectos de la radiación , Cloro/farmacología , Marcadores Genéticos , Humanos , Ohio , Reacción en Cadena de la Polimerasa , Estaciones del Año
11.
J AOAC Int ; 97(3): 956-62, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25051650

RESUMEN

The polyatomic background at the major isotope of Cr was evaluated as a function of collision cell gas flow rate using three different mobile phases. The stability of Cr VIwas evaluated as a function of solution pH by fortifying samples with enriched 53Cr VI. The 53Cr VI recovery was > or =95% at pH 7.8, but by pH 6.2 a significant amount of the enriched spike was recovered as 53Cr III-EDTA. The instability of Cr III at pHs above 7.8 required that Cr III be chelated prior to speciation. The concentration of EDTA was optimized by evaluating Cr III recoveries in six finished drinking waters, a U.S. Geological Survey reference water, and a challenge water fortified with competing matrix cations. If the Cr III was allowed to precipitate (characteristic of shipping a sample without field preservation), acceptable recoveries of Cr III required the sample to be heated to 70 degrees C in 10 mM EDTA to quantitatively produce the Cr III-EDTA complex. The overall preservation/speciation approach was evaluated using an enriched 53Cr VI and natural Cr III in seven drinking water matrixes over a 46 day period. A linear least squares analysis was performed on each water, and the corresponding P-values were estimated. The method detection limits for Cr III-EDTA and Cr VI were 0.06 and 0.1 pglL, respectively.


Asunto(s)
Cromatografía Liquida/métodos , Cromo/análisis , Agua Potable/análisis , Espectrometría de Masas/métodos , Ácido Edético/química , Concentración de Iones de Hidrógeno , Límite de Detección , Espectrofotometría Atómica
12.
Appl Environ Microbiol ; 79(1): 215-23, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23087037

RESUMEN

The U.S. EPA developed a sample concentration and preparation assay in conjunction with the total culturable virus assay for concentrating and measuring culturable viruses in source and drinking waters as part of the Information Collection Rule (ICR) promulgated in 1996. In an effort to improve upon this method, the U.S. EPA recently developed Method 1615: Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. Method 1615 uses a culturable virus assay with reduced equipment and labor costs compared to the costs associated with the ICR virus method and introduces a new molecular assay for the detection of enteroviruses and noroviruses by reverse transcription-quantitative PCR. In this study, we describe the optimization of several new components of the molecular assay and examine virus recovery from ground, reagent-grade, and surface water samples seeded with poliovirus type 3 and murine norovirus. For the culturable virus and molecular assays, mean poliovirus recovery using the complete method was 58% and 20% in groundwater samples, 122% and 39% using low-titer spikes in reagent-grade water, 42% and 48% using high-titer spikes in reagent-grade water, and 11% and 10% in surface water with high turbidity, respectively. Murine norovirus recovery by the molecular assay was 30% in groundwater samples, less than 8% in both low- and high-titer spikes in reagent-grade water, and 6% in surface water with high turbidity. This study demonstrates the effectiveness of Method 1615 for use with groundwater samples and highlights the need for further research into its effectiveness with surface water.


Asunto(s)
Norovirus/aislamiento & purificación , Poliovirus/aislamiento & purificación , Virología/métodos , Microbiología del Agua , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Cultivo de Virus/métodos
13.
Environ Res ; 122: 98-101, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23419817

RESUMEN

Higher values of the environmental relative moldiness index (ERMI), a DNA-based method for quantifying indoor molds, have been associated with asthma in children. In this study, settled dust samples were collected from the homes of adults with asthma, rhinitis, or both conditions (n=139 homes) in Northern California. The ERMI values for these samples were compared to those from dust collected in homes from the same geographic region randomly selected as part of the 2006 American Healthy Home Survey (n=44). The median ERMI value in homes of adult with airway disease (6) was significantly greater than median ERMI value (2) in the randomly selected homes (p<0.0001). In this study in Northern California, the homes of adults with asthma had ERMI values consistent with a heavier burden of indoor mold than that measured in other homes from the same region.


Asunto(s)
Asma/etiología , Polvo/análisis , Hongos/aislamiento & purificación , Rinitis/etiología , Adulto , Vivienda/estadística & datos numéricos , Humanos
14.
BMC Public Health ; 13: 459, 2013 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-23663297

RESUMEN

BACKGROUND: The United States Environmental Protection Agency (USEPA) and its predecessors have conducted three distinct series of epidemiological studies beginning in 1948 on the relationship between bathing water quality and swimmers' illnesses. Keeping pace with advances in microbial technologies, these studies differed in their respective microbial indicators of water quality. Another difference, however, has been their specific health endpoints. The latest round of studies, the National Epidemiological Assessment of Recreational (NEEAR) Water studies initiated in 2002, used a case definition, termed "NEEAR GI illness" (NGI), for gastrointestinal illness corresponding closely to classifications employed by contemporary researchers, and to that proposed by the World Health Organization. NGI differed from the previous definition of "highly credible gastrointestinal illness" (HCGI) upon which the USEPA's 1986 bathing water criteria had been based, primarily by excluding fever as a prerequisite. METHODS: Incidence of NGI from the NEEAR studies was compared to that of HCGI from earlier studies. Markov chain Monte Carlo method was used to estimate the respective beta binomial probability densities for NGI and HCGI establish credible intervals for the risk ratio of NGI to HCGI. RESULTS: The ratio of NGI risk to that of HCGI is estimated to be 4.5 with a credible interval 3.2 to 7.7. CONCLUSIONS: A risk level of 8 HCGI illnesses per 1000 swimmers, as in the 1986 freshwater criteria, would correspond to 36 NGI illnesses per 1000 swimmers. Given a microbial DNA-based (qPCR) water quality vs. risk relationship developed from the NEEAR studies, 36 NGI per 1000 corresponds to a geometric mean of 475 qPCR cell-equivalents per 100 ml.


Asunto(s)
Playas/legislación & jurisprudencia , Monitoreo del Ambiente/métodos , Playas/normas , Monitoreo del Ambiente/normas , Femenino , Humanos , Masculino , Cadenas de Markov , Método de Montecarlo , Medición de Riesgo , Estados Unidos , Microbiología del Agua , Calidad del Agua
15.
J Allergy Clin Immunol Glob ; 2(4): 1-4, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37680344

RESUMEN

Background: Despite improvements in asthma symptom management and asthma morbidity, the prevalence of asthma in the United States remains high, especially in underresourced communities. Objective: Our goal was to determine whether housing renovations affect the prevalence of asthma in an underresourced community. Methods: The Fay Apartments (~800 units) in Cincinnati, Ohio, were renovated to "green building" standards between 2010 and 2012 and renamed the Villages at Roll Hill. The prevalence of asthma among 7-year-olds in the Villages at Roll Hill was determined by accessing Ohio Medicaid data for the years 2013 to 2021. Results: In the first 6 years after the renovations (2013-2018), the prevalence of asthma among 7-year-olds in the community averaged 12.7%. In contrast, in postrenovation years 7 through 9 (2019-2021), the average prevalence of asthma was 5.9%. Logistic regression modeling for the log odds of asthma diagnosis in this age group was used to test the statistical significance of asthma prevalence for 2013-2018 versus for 2019-2021. The model resulted in demonstration of a significant (P < .001) reduction in asthma prevalence between 2013-2018 and 2019-2021. Conclusions: The renovation of an underresourced community's housing resulted in a lower prevalence of asthma for 7-year-olds who were born after the renovations had been completed.

16.
Int J Hyg Environ Health ; 249: 114141, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36812733

RESUMEN

The Sun Valley Homes public housing in Denver, Colorado (CO) will be replaced because of its deteriorated condition. Our goal was to document the mold contamination and particulate matter (PM2.5) concentrations in Sun Valley homes and the circulatory and respiratory health of Sun Valley compared to all Denver residents (total 2761 and 1,049,046, respectively) based on insurance claims data for 2015 to 2019. Mold contamination in Sun Valley homes (n = 49) was quantified using the Environmental Relative Moldiness Index (ERMI) scale. Indoor PM2.5 concentrations were measured in Sun Valley homes (n = 11) using time-integrated, filter-based samples and quantified using gravimetric analysis. Outdoor PM2.5 concentrations data were obtained from a near-by United States Environmental Protection Agency monitoring station. In Sun Valley homes, the average ERMI value was 5.25 compared to -1.25 for other Denver homes. The PM2.5 median concentration inside Sun Valley homes was 7.6 µg/m3 (interquartile range - 6.4 µg/m3). The ratio of indoor to outdoor concentrations of PM2.5 was 2.3 (interquartile range - 1.5). In the last five years, ischemic heart disease was significantly more likely for Denver compared to Sun Valley residents. However, acute upper respiratory infections, chronic lower respiratory diseases and asthma were all significantly more likely for Sun Valley than Denver residents. Since the process of replacing and occupying the new housing will take several years, the next phase of the study will not occur until that process is complete.


Asunto(s)
Contaminación del Aire Interior , Asma , Estados Unidos , Humanos , Colorado , Vivienda , Seguro de Salud , Hongos , Material Particulado/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente
17.
Appl Environ Microbiol ; 78(19): 7166-9, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22865067

RESUMEN

Few studies have addressed the efficacy of composite sampling for measuring indicator bacteria by quantitative PCR (qPCR). We compared results from composited samples with multiple-sample means for culture- and qPCR-based water quality monitoring. Results from composited samples for both methods were similarly correlated to multiple-sample means and predicted criteria exceedances equally.


Asunto(s)
Bacterias/clasificación , Bacterias/aislamiento & purificación , Técnicas Bacteriológicas/métodos , Heces/microbiología , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Microbiología del Agua , Contaminantes del Agua , Bacterias/genética , Bacterias/crecimiento & desarrollo
18.
J Water Health ; 10(4): 511-21, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23165708

RESUMEN

Since numerous pathogens occur in feces, water is monitored for fecal contamination using indicator organisms rather than individual pathogens. Although this approach is supported by health effects data in recreational waters, it is questionable when used for drinking water. Most outbreaks in groundwater occur in systems that have not violated the US EPA's maximum contaminant limit (MCL) for total coliforms within 12 months before the outbreak. Additionally, environmentally stable viruses and parasites are often detected in drinking water samples with no detectable indicators. Recent detections of Escherichia coli O157:H7 and Campylobacter jejuni in groundwaters in the apparent absence of indicators also cast some doubt on the worth of indicators for fecal bacterial pathogens. Individual pathogen monitoring is now technically achievable but currently unreasonable due to the number of possible pathogens and the costs involved. Several alternatives to pathogen monitoring could significantly reduce the frequency at which pathogens occur in waters testing negative for indicators: (i) increasing sample volumes for indicators, (ii) increasing monitoring frequency, (iii) using a suite of indicators, (iv) using a more conservative polymerase chain reaction (PCR) method, (v) sampling when fecal contamination is most likely present or (vi) any combination of these options.


Asunto(s)
Agua Potable/normas , Monitoreo del Ambiente/métodos , Monitoreo del Ambiente/normas , Agua Subterránea/normas , Agua Potable/microbiología , Agua Potable/parasitología , Agua Potable/virología , Heces/microbiología , Heces/parasitología , Heces/virología , Agua Subterránea/microbiología , Agua Subterránea/parasitología , Agua Subterránea/virología , Reacción en Cadena de la Polimerasa/métodos , Tamaño de la Muestra , Factores de Tiempo , Calidad del Agua/normas
19.
J Water Health ; 10(1): 43-55, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22361701

RESUMEN

Estrogenic compounds have been shown to be present in surface waters, leading to concerns over their possible presence in finished drinking waters. In this work, two in vitro human cell line bioassays for estrogenicity were used to evaluate the removal of estrogens through conventional drinking water treatment using a natural water. Bench-scale studies utilizing chlorine, alum coagulation, ferric chloride coagulation, and powdered activated carbon (PAC) were conducted using Ohio River water spiked with three estrogens, 17ß-estradiol, 17α-ethynylestradiol, and estriol. Treatment of the estrogens with chlorine, either alone or with coagulant, resulted in approximately 98% reductions in the concentrations of the parent estrogens, accompanied by formation of by-products. The MVLN reporter gene and MCF-7 cell proliferation assays were used to characterize the estrogenic activity of the water before and after treatment. The observed estrogenic activities of the chlorinated samples showed that estrogenicity of the water was reduced commensurate with removal of the parent estrogen. Therefore, the estrogen chlorination by-products did not contribute appreciably to the estrogenic activity of the water. Coagulation alone did not result in significant removals of the estrogens. However, addition of PAC, at a typical drinking water plant dose, resulted in removals ranging from approximately 20 to 80%.


Asunto(s)
Bioensayo/métodos , Agua Potable/química , Estradiol/química , Estriol/química , Etinilestradiol/química , Contaminantes Químicos del Agua/análisis , Purificación del Agua/métodos , Compuestos de Alumbre/química , Carbón Orgánico/química , Cloruros/química , Cloro/química , Compuestos Férricos/química , Humanos , Ohio , Contaminantes Químicos del Agua/química
20.
Life (Basel) ; 12(5)2022 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-35629409

RESUMEN

To ensure drinking-water safety, it is necessary to understand the factors that regulate harmful cyanobacterial blooms (HCBs) and the toxins they produce. One controlling factor might be any relationship between fungi and the cyanobacteria. To test this possibility, water samples were obtained from Harsha Lake in southwestern Ohio during the 2015, 2016, and 2017 bloom seasons, i.e., late May through September. In each water sample, the concentration of the filamentous fungus Cladosporium cladosporioides was determined by quantitative PCR (qPCR) assay, and Microcystis aeruginosa microcystin-gene transcript copy number (McyG TCN) was quantified by reverse-transcriptase qPCR (RT-qPCR) analyses. The results showed that during each bloom season, the C. cladosporioides concentration and McyG TCN appeared to be interrelated. Therefore, C. cladosporioides concentrations were statistically evaluated via regression on McyG TCN in the water samples for lag times of 1 to 7 days. The regression equation developed to model the relationship demonstrated that a change in the C. cladosporioides concentration resulted in an opposing change in McyG TCN over an approximately 7-day interval. Although the interaction between C. cladosporioides and McyG TCN was observed in each bloom season, the magnitude of each component varied yearly. To better understand this possible interaction, outdoor Cladosporium spore-count data for the Harsha Lake region were obtained for late May through September of each year from the South West Ohio Air Quality Agency. The average Cladosporium spore count in the outdoor air samples was significantly greater in 2016 than in either 2015 or 2017, and the M. aeruginosa McyG TCN was significantly lower in Harsha Lake water samples in 2016 compared to 2015 or 2017. These results suggest that there might be a "balanced antagonism" between C. cladosporioides and M. aeruginosa during the bloom season.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA