Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Idioma
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(3): 829-33, 2013 Mar.
Artículo en Zh | MEDLINE | ID: mdl-23705464

RESUMEN

Third-generation synchrotron radiation X-ray phase-contrast microscopy(XPCM)can be used for obtaining image with edge enhancement, and achieve the high contrast imaging of low-Z materials with the spatial coherence peculiarity of X-rays. In the present paper, the characteristic microstructures of adhesive at the interface and their penetration in wood/bamboo composite material were investigated systematically by XPCM at Shanghai Synchrotron Radiation Facility (SSRF). And the effect of several processing techniques was analyzed for the adhesive penetration in wood/bamboo materials. The results show that the synchrotron radiation XPCM is expected to be one of the important precision detection methods for wood-based panels.


Asunto(s)
Microscopía de Contraste de Fase/métodos , Sasa/ultraestructura , Tomografía Computarizada por Rayos X/métodos , Madera/ultraestructura , Adhesivos , Materiales Manufacturados , Intensificación de Imagen Radiográfica , Sincrotrones
2.
Zhonghua Yi Xue Za Zhi ; 92(11): 778-82, 2012 Mar 20.
Artículo en Zh | MEDLINE | ID: mdl-22781361

RESUMEN

OBJECTIVE: To detect deep-level microvascular structure in rat hind limb by synchrotron radiation and microangiographic technique. METHODS: Microangiography in vivo and ex vivo was performed by synchrotron radiation based absorption imaging and phase contrast imaging, with omnipaque and barium sulfate solution as contrast media, respectively, and synchrotron radiation-based micro-computed tomography (SRmCT) was also performed to reveal three-dimensional morphology of the blood vessel in rat hind limb. RESULTS: Using microangiographic technique in vivo and in vitro (with barium sulfate), blood vessels in the rat limb muscle could be visualized with high resolution, and the fourth branches of iliac artery in rat hind limb could be detected with the minimum visualized blood vessels about 40 µm and 9 µm in diameter, respectively. In addition, the vascular network could be defined and analyzed at the micrometer scale from the 3D renderings of limb vessel as shown by SRmCT. CONCLUSION: Synchrotron radiation-based microangiography and SRmCT thus provided a practical and effective means to observe the microvasculature of rat hindlimb, which might be useful in assessment of angiogenesis in lower limbs.


Asunto(s)
Miembro Posterior/irrigación sanguínea , Miembro Posterior/diagnóstico por imagen , Microvasos/diagnóstico por imagen , Angiografía/métodos , Animales , Masculino , Microcirculación , Ratas , Ratas Endogámicas F344 , Sincrotrones , Tomografía Computarizada por Rayos X/métodos
3.
Zhonghua Shao Shang Za Zhi ; 28(1): 5-8, 2012 Feb.
Artículo en Zh | MEDLINE | ID: mdl-22490532

RESUMEN

OBJECTIVE: To compare the morphological difference between dermal tissue of normal skin and that of scar in rat, and to explore its structural pattern. METHODS: The full-thickness skin and the scar tissue formed 3 weeks after wound healing from SD rats were harvested as samples, which were prepared appropriately afterwards. Samples were scanned and imaged with synchrotron radiation technology, micro-CT, and phase-contrast imaging technology. The images were rebuilt with three-dimensional software. RESULTS: The micro-CT was materialized by using X-ray generated by synchrotron radiation light source. The structure of dermal tissues was clearly shown with the assistance of phase-contrast imaging technology in the process. It was demonstrated that the dermal tissues of normal skin of rat were mainly composed of collagenous fibers, which twined together to form an olive-like structure. These olive-like structures as basic units were arranged randomly in a certain way. The collagenous fibers in dermal tissue of the scar were arranged in a parallel manner, while some fibers were crooked and arranged in a disorderly manner. CONCLUSIONS: Dermal tissue of normal skin in rat has stable three-dimensional structure, and its basic structure and manner of composition are obviously different from those of scar dermal tissue.


Asunto(s)
Cicatriz/diagnóstico por imagen , Dermis/diagnóstico por imagen , Imagenología Tridimensional/métodos , Animales , Dermis/patología , Masculino , Microscopía de Contraste de Fase , Ratas , Ratas Sprague-Dawley , Piel/diagnóstico por imagen , Sincrotrones , Tomografía Computarizada por Rayos X , Cicatrización de Heridas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA