Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
NMR Biomed ; 37(3): e5073, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37990800

RESUMEN

The goal of this study was to investigate the origin of brain lactate (Lac) signal in the healthy anesthetized rat after injection of hyperpolarized (HP) [1-13 C]pyruvate (Pyr). Dynamic two-dimensional spiral chemical shift imaging with flow-sensitizing gradients revealed reduction in both vascular and brain Pyr, while no significant dependence on the level of flow suppression was detected for Lac. These results support the hypothesis that the HP metabolites predominantly reside in different compartments in the brain (i.e., Pyr in the blood and Lac in the parenchyma). Data from high-resolution metabolic imaging of [1-13 C]Pyr further demonstrated that Lac detected in the brain was not from contributions of vascular signal attributable to partial volume effects. Additionally, metabolite distributions and kinetics measured with dynamic imaging after injection of HP [1-13 C]Lac were similar to Pyr data when Pyr was used as the substrate. These data do not support the hypothesis that Lac observed in the brain after Pyr injection was generated in other organs and then transported across the blood-brain barrier (BBB). Together, the presented results provide further evidence that even in healthy anesthetized rats, the transport of HP Pyr across the BBB is sufficiently fast to permit detection of its metabolic conversion to Lac within the brain.


Asunto(s)
Ácido Láctico , Ácido Pirúvico , Ratas , Animales , Ácido Pirúvico/metabolismo , Ácido Láctico/metabolismo , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Barrera Hematoencefálica/diagnóstico por imagen , Isótopos de Carbono/metabolismo
2.
NMR Biomed ; 36(5): e4873, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36347826

RESUMEN

T1 relaxation times of the 14 T1 phantom spheres that make up the standard International Society for Magnetic Resonance in Medicine (ISMRM)/National Institute of Standards and Technology (NIST) system phantom are reported at 7 T. T1 values of six of the 14 T1 spheres at 7 T (with T1 > 270 ms) have been reported previously, but, to the best of our knowledge, not all of the T1s of the 14 T1 spheres at 7 T have been reported before. Given the increasing number of 7-T MRI systems in clinical settings and the increasing need for T1 phantoms that cover a wide range of T1 relaxation times to evaluate rapid T1 mapping techniques at 7 T, it is of high interest to obtain accurate T1 values for all the ISMRM/NIST T1 spheres at 7 T. In this work, T1 relaxation time was measured on a 7-T MRI scanner using an inversion-recovery spin-echo pulse sequence and derived by curve fitting to a signal equation that exhibits insensitivity to B 1 + inhomogeneity. Day-to-day reproducibility was within 0.4% and differences between two different RF coils within 1.5%. T1s of a subset of the 14 spheres were also measured by NMR at 7 T for comparison, and the T1 results were consistent between the MRI and NMR measurements. T1 measurements performed at 3 T on the same 14 spheres using the same sequence and fitting method yielded good agreement (mean percentage difference of -0.4%) with the reference T1 values available from the NIST, reflecting the accuracy of the reported technique despite being without the standard phantom housing. We found that the T1 values of all 14 NiCl2 spheres are consistently lower at 7 T than at 3 T. Although our results were well reproduced, this study represents initial work to quantify the 7-T T1 values of all 14 NIST T1 spheres outside of the standard housing and does not warrant reproducibility of the ISMRM/NIST system phantom as a whole. A future study to assess the T1 values of a version of the ISMRM/NIST system phantom that fits inside typical commercial coils at 7 T will be very helpful. Nonetheless, the details on our acquisition and curve-fitting methods reported here allow the T1 measurements to be reproduced elsewhere. The T1 values of all 14 spheres reported here will be valuable for the development of quantitative MR fingerprinting and rapid T1 mapping for a large variety of research projects, not only in neuroimaging but also in body MRI, musculoskeletal MRI, and gadolinium contrast-enhanced MRI, each of which is concerned with much shortened T1.


Asunto(s)
Imagen por Resonancia Magnética , Neuroimagen , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Valores de Referencia
3.
Angew Chem Int Ed Engl ; 62(31): e202219181, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37247411

RESUMEN

We report dissolution Dynamic Nuclear Polarization (d-DNP) of [15 N3 ]metronidazole ([15 N3 ]MNZ) for the first time. Metronidazole is a clinically approved antibiotic, which can be potentially employed as a hypoxia-sensing molecular probe using 15 N hyperpolarized (HP) nucleus. The DNP process is very efficient for [15 N3 ]MNZ with an exponential build-up constant of 13.8 min using trityl radical. After dissolution and sample transfer to a nearby 4.7 T Magnetic Resonance Imaging scanner, HP [15 N3 ]MNZ lasted remarkably long with T1 values up to 343 s and 15 N polarizations up to 6.4 %. A time series of HP [15 N3 ]MNZ images was acquired in vitro using a steady state free precession sequence on the 15 NO2 peak. The signal lasted over 13 min with notably long T2 of 20.5 s. HP [15 N3 ]MNZ was injected in the tail vein of a healthy rat, and dynamic spectroscopy was performed over the rat brain. The in vivo HP 15 N signals persisted over 70 s, demonstrating an unprecedented opportunity for in vivo studies.


Asunto(s)
Antibacterianos , Metronidazol , Ratas , Animales , Metronidazol/farmacología , Antibacterianos/farmacología , Solubilidad , Espectroscopía de Resonancia Magnética/métodos , Imagen por Resonancia Magnética
4.
Radiology ; 302(2): 410-418, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34751617

RESUMEN

Background Patients with recurrent glioblastoma (GBM) are often treated with antiangiogenic agents, such as bevacizumab (BEV). Despite therapeutic promise, conventional MRI methods fail to help determine which patients may not benefit from this treatment. Purpose To use MR spectroscopic imaging (MRSI) with intermediate and short echo time to measure corrected myo-inositol (mI)normalized by contralateral creatine (hereafter, mI/c-Cr) in participants with recurrent GBM treated with BEV and to investigate whether such measurements can help predict survivorship before BEV initiation (baseline) and at 1 day, 4 weeks, and 8 weeks thereafter. Materials and Methods In this prospective longitudinal study (2016-2020), spectroscopic data on mI-a glial marker and osmoregulator within the brain-normalized by contralateral creatine in the intratumoral, contralateral, and peritumoral volumes of patients with recurrent GBM were evaluated. Area under the receiver operating characteristic curve (AUC) was calculated for all volumes at baseline and 1 day, 4 weeks, and 8 weeks after treatment to determine the ability of mI/c-Cr to help predict survivorship. Results Twenty-one participants (median age ± standard deviation, 62 years ± 12; 15 men) were evaluated. Lower mI/c-Cr in the tumor before and during BEV treatment was predictive of poor survivorship, with receiver operating characteristic analyses showing an AUC of 0.75 at baseline, 0.87 at 1 day after treatment, and 1 at 8 weeks after. A similar result was observed in contralateral normal-appearing tissue and the peritumoral volume, with shorter-term survivors having lower levels of mI/c-Cr. In the contralateral volume, a lower ratio of mI to creatine (hereafter, mI/Cr) predicted shorter-term survival at baseline and all other time points. Within the peritumoral volume, lower mI/c-Cr levels were predictive of shorter-term survival at baseline (AUC, 0.80), at 1 day after treatment (AUC, 0.93), and at 4 weeks after treatment (AUC, 0.68). Conclusion Lower levels of myo-inositol normalized by contralateral creatine within intratumoral, contralateral, and peritumoral volumes were predictive of poor survivorship and antiangiogenic treatment failure as early as before bevacizumab treatment. Adapting MR spectroscopic imaging alongside conventional MRI modalities conveys critical information regarding the biologic characteristics of tumors to help better treat individuals with recurrent glioblastoma. Clinical trial registration no. NCT02843230 © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Inhibidores de la Angiogénesis/uso terapéutico , Bevacizumab/uso terapéutico , Neoplasias Encefálicas/tratamiento farmacológico , Glioblastoma/tratamiento farmacológico , Inositol/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Biomarcadores de Tumor/metabolismo , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Valor Predictivo de las Pruebas , Estudios Prospectivos , Insuficiencia del Tratamiento
5.
J Chem Phys ; 152(18): 184202, 2020 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-32414242

RESUMEN

High-field nuclear magnetic resonance (NMR) spectroscopy is an indispensable technique for identification and characterization of chemicals and biomolecular structures. In the vast majority of NMR experiments, nuclear spin polarization arises from thermalization in multi-Tesla magnetic fields produced by superconducting magnets. In contrast, NMR instruments operating at low magnetic fields are emerging as a compact, inexpensive, and highly accessible alternative but suffer from low thermal polarization at a low field strength and consequently a low signal. However, certain hyperpolarization techniques create high polarization levels on target molecules independent of magnetic fields, giving low-field NMR a significant sensitivity boost. In this study, SABRE (Signal Amplification By Reversible Exchange) was combined with high homogeneity electromagnets operating at mT fields, enabling high resolution 1H, 13C, 15N, and 19F spectra to be detected with a single scan at magnetic fields between 1 mT and 10 mT. Chemical specificity is attained at mT magnetic fields with complex, highly resolved spectra. Most spectra are in the strong coupling regime where J-couplings are on the order of chemical shift differences. The spectra and the hyperpolarization spin dynamics are simulated with SPINACH. The simulations start from the parahydrogen singlet in the bound complex and include both chemical exchange and spin evolution at these mT fields. The simulations qualitatively match the experimental spectra and are used to identify the spin order terms formed during mT SABRE. The combination of low field NMR instruments with SABRE polarization results in sensitive measurements, even for rare spins with low gyromagnetic ratios at low magnetic fields.

6.
Magn Reson Med ; 82(3): 973-983, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31069861

RESUMEN

PURPOSE: Dynamic susceptibility contrast imaging requires high temporal sampling, which poses limits on achievable spatial coverage and resolution. Additionally, more encoding-intensive multi-echo acquisitions for quantitative imaging are desired to mitigate contrast leakage effects, which further limits spatial encoding. We present an accelerated sequence that provides whole-brain coverage at an improved spatio-temporal resolution, to allow for dynamic quantitative R2 and R2 * mapping during contrast-enhanced imaging. METHODS: A multi-echo spin and gradient-echo sequence was implemented with simultaneous multislice acquisition. Complementary k-space sampling between repetitions and joint virtual coil reconstruction were used along with a dynamic phase-matching technique to achieve high-quality reconstruction at 9-fold acceleration, which enabled 2 × 2 × 5 mm whole-brain imaging at TR of 1.5 to 1.7 seconds. The multi-echo images from this sequence were fit to achieve quantitative R2 and R2 * maps for each repetition, and subsequently used to find perfusion measures including cerebral blood flow and cerebral blood volume. RESULTS: Images reconstructed using joint virtual coil show improved image quality and g-factor compared with conventional reconstruction methods, resulting in improved quantitative maps with a 9-fold acceleration factor and whole-brain coverage during the dynamic perfusion acquisition. CONCLUSION: The method presented shows the advantage of using a joint virtual coil-GRAPPA reconstruction to allow for high acceleration factors while maintaining reliable image quality for quantitative perfusion mapping, with the potential to improve tumor diagnostics and monitoring.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Encéfalo/irrigación sanguínea , Circulación Cerebrovascular/fisiología , Humanos
7.
Chemistry ; 25(37): 8829-8836, 2019 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-30964568

RESUMEN

The NMR hyperpolarization of uniformly 15 N-labeled [15 N3 ]metronidazole is demonstrated by using SABRE-SHEATH. In this antibiotic, the 15 NO2 group is hyperpolarized through spin relays created by 15 N spins in [15 N3 ]metronidazole, and the polarization is transferred from parahydrogen-derived hydrides over six chemical bonds. In less than a minute of parahydrogen bubbling at approximately 0.4 µT, a high level of nuclear spin polarization (P15N ) of around 16 % is achieved on all three 15 N sites. This product of 15 N polarization and concentration of 15 N spins is around six-fold better than any previous value determined for 15 N SABRE-derived hyperpolarization. At 1.4 T, the hyperpolarized state persists for tens of minutes (relaxation time, T1 ≈10 min). A novel synthesis of uniformly 15 N-enriched metronidazole is reported with a yield of 15 %. This approach can potentially be used for synthesis of a wide variety of in vivo metabolic probes with potential uses ranging from hypoxia sensing to theranostic imaging.

8.
Radiology ; 286(3): 865-872, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29117483

RESUMEN

Purpose To compare intravascular contrast enhancement produced by the manganese-based magnetic resonance (MR) imaging contrast agent manganese-N-picolyl-N,N',N'-trans-1,2-cyclohexenediaminetriacetate (Mn-PyC3A) to gadopentetate dimeglumine (Gd-DTPA) and to evaluate the excretion, pharmacokinetics, and metabolism of Mn-PyC3A. Materials and Methods Contrast material-enhanced MR angiography was performed in baboons (Papio anubis; n = 4) by using Mn-PyC3A and Gd-DTPA. Dynamic imaging was performed for 60 minutes following Mn-PyC3A injection to monitor distribution and elimination. Serial blood sampling was performed to quantify manganese and gadolinium plasma clearance by using inductively coupled plasma mass spectrometry and to characterize Mn-PyC3A metabolism by using high-performance liquid chromatography. Intravascular contrast enhancement in the abdominal aorta and brachiocephalic artery was quantified by measuring contrast-to-noise ratios (CNRs) versus muscle at 9 seconds following Mn-PyC3A or Gd-DTPA injection. Plasma pharmacokinetics were modeled with a biexponential function, and data were compared with a paired t test. Results Aorta versus muscle CNR (mean ± standard deviation) with Mn-PyC3A and Gd-DTPA was 476 ± 77 and 538 ± 120, respectively (P = .11). Brachiocephalic artery versus muscle CNR was 524 ± 55 versus 518 ± 140, respectively (P = .95). Mn-PyC3A was eliminated via renal and hepatobiliary excretion with similar pharmacokinetics to Gd-DTPA (area under the curve between 0 and 30 minutes, 20.2 ± 3.1 and 17.0 ± 2.4, respectively; P = .23). High-performance liquid chromatography revealed no evidence of Mn-PyC3A biotransformation. Conclusion Mn-PyC3A enables contrast-enhanced MR angiography with comparable contrast enhancement to gadolinium-based agents and may overcome concerns regarding gadolinium-associated toxicity and retention. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Medios de Contraste/farmacocinética , Gadolinio DTPA/farmacocinética , Angiografía por Resonancia Magnética/métodos , Manganeso/farmacocinética , Compuestos Organometálicos/farmacocinética , Animales , Aorta Abdominal/diagnóstico por imagen , Femenino , Semivida , Eliminación Hepatobiliar , Procesamiento de Imagen Asistido por Computador/métodos , Riñón/diagnóstico por imagen , Riñón/metabolismo , Papio , Arteria Renal/diagnóstico por imagen
9.
Magn Reson Med ; 71(6): 2051-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23878057

RESUMEN

PURPOSE: In contrast to [1-(13) C]pyruvate, hyperpolarized [2-(13) C]pyruvate permits the ability to follow the (13) C label beyond flux through pyruvate dehydrogenase complex and investigate the incorporation of acetyl-coenzyme A into different metabolic pathways. However, chemical shift imaging (CSI) with [2-(13) C]pyruvate is challenging owing to the large spectral dispersion of the resonances, which also leads to severe chemical shift displacement artifacts for slice-selective acquisitions. METHODS: This study introduces a sequence for three-dimensional CSI of [2-(13) C]pyruvate using spectrally selective excitation of limited frequency bands containing a subset of metabolites. Dynamic CSI data were acquired alternately from multiple frequency bands in phantoms for sequence testing and in vivo in rat heart. RESULTS: Phantom experiments verified the radiofrequency pulse design and demonstrated that the signal behavior of each group of resonances was unaffected by excitation of the other frequency bands. Dynamic three-dimensional (13) C CSI data demonstrated the sequence capability to image pyruvate, lactate, acetylcarnitine, glutamate, and acetoacetate, enabling the analysis of organ-specific spectra and metabolite time courses. CONCLUSIONS: The presented method allows CSI of widely separated resonances without chemical shift displacement artifact, acquiring multiple frequency bands alternately to obtain dynamic time-course information. This approach enables robust imaging of downstream metabolic products of acetyl-coenzyme A with hyperpolarized [2-(13) C]pyruvate.


Asunto(s)
Imagenología Tridimensional , Espectroscopía de Resonancia Magnética/métodos , Miocardio/metabolismo , Piruvatos/metabolismo , Acetoacetatos/metabolismo , Acetilcarnitina/metabolismo , Animales , Isótopos de Carbono/metabolismo , Medios de Contraste/química , Ácido Glutámico/metabolismo , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Lactatos/metabolismo , Masculino , Meglumina/química , Compuestos Organometálicos/química , Fantasmas de Imagen , Ratas , Ratas Wistar , Factores de Tiempo
10.
Mol Imaging Biol ; 26(2): 222-232, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38147265

RESUMEN

Hyperpolarization techniques significantly enhance the sensitivity of magnetic resonance (MR) and thus present fascinating new directions for research and applications with in vivo MR imaging and spectroscopy (MRI/S). Hyperpolarized 13C MRI/S, in particular, enables real-time non-invasive assessment of metabolic processes and holds great promise for a diverse range of clinical applications spanning fields like oncology, neurology, and cardiology, with a potential for improving early diagnosis of disease, patient stratification, and therapy response assessment. Despite its potential, technical challenges remain for achieving clinical translation. This paper provides an overview of the discussions that took place at the international workshop "New Horizons in Hyperpolarized 13C MRI," in March 2023 at the Bavarian Academy of Sciences and Humanities, Munich, Germany. The workshop covered new developments, as well as future directions, in topics including polarization techniques (particularly focusing on parahydrogen-based methods), novel probes, considerations related to data acquisition and analysis, and emerging clinical applications in oncology and other fields.


Asunto(s)
Imagen por Resonancia Magnética , Oncología Médica , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos
11.
Magn Reson Med ; 70(4): 936-42, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23165935

RESUMEN

PURPOSE: The use of unlabeled exchange-linked dissolution agents in hyperpolarized metabolic imaging was studied to examine pool size limits and saturation relative to the availability of NADH. METHODS: Three-dimensional dynamic metabolic images were obtained, and compared following injection of a bolus of hyperpolarized [1-(13)C]pyruvate, prepared with and without unlabeled sodium lactate in the dissolution buffer. Comparisons were made on the basis of apparent rate constants and [1-(13)C]lactate signal-to-noise ratio. Range finding data were obtained for different bolus compositions. Isotope exchange was also probed in the reverse direction, following injection of a bolus of hyperpolarized [1-(13)C]lactate, with and without unlabeled sodium pyruvate in the dissolution buffer. RESULTS: Liver, kidney, and vascular regions of interest all showed an increase in [1-(13)C]lactate signal with addition of unlabeled sodium lactate in the dissolution buffer. Injection of hyperpolarized [1-(13)C]lactate with unlabeled sodium pyruvate in the dissolution buffer, provided exchange rate constants Klp for kidney and vascular regions of interest. CONCLUSIONS: These results are consistent with a high level of (13)C-exchange, and with labeling rates that are limited by steady-state pool sizes in vivo.


Asunto(s)
Vasos Sanguíneos/metabolismo , Riñón/metabolismo , Hígado/metabolismo , Imagen por Resonancia Magnética/métodos , Imagen Molecular/métodos , Ácido Pirúvico/farmacocinética , Lactato de Sodio/farmacocinética , Animales , Isótopos de Carbono/farmacocinética , Masculino , Especificidad de Órganos , Radiofármacos/farmacocinética , Ratas , Ratas Wistar , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Magn Reson Med ; 70(4): 1117-24, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23086864

RESUMEN

PURPOSE: Commonly used anesthetic agents such as isoflurane are known to be potent cerebral vasodilators, with reported dose-dependent increase in cerebral blood flow and cerebral blood volume. Despite the widespread use of isoflurane in hyperpolarized (13)C preclinical research studies, a quantitative assessment of its effect on metabolic measurements is limited. This work investigates the effect of isoflurane anesthesia dose on hyperpolarized (13)C MR metabolic measurements in rat brain for [1-(13)C]pyruvate and 2-keto[1-(13)C]isocaproate. METHODS: Dynamic 2D and 3D spiral chemical shift imaging was used to acquire metabolic images of rat brain as well as kidney and liver following bolus injections of hyperpolarized [1-(13)C]pyruvate or 2-keto[1-(13)C]isocaproate. The impact of a "low dose" vs. a "high dose" of isoflurane on cerebral metabolite levels and apparent conversion rates was examined. RESULTS: The cerebral substrate signal levels, and hence the metabolite-to-substrate ratios and apparent conversion rates, were found to depend markedly on isoflurane dose, while signal levels of metabolic products and their ratios, e.g. bicarbonate/lactate, were largely insensitive to isoflurane levels. No obvious dependence on isoflurane was observed in kidney or liver for pyruvate. CONCLUSION: This study highlights the importance of careful attention to the effects of anesthesia on the metabolic measures for hyperpolarized (13)C metabolic imaging in brain.


Asunto(s)
Encéfalo/efectos de los fármacos , Encéfalo/metabolismo , Caproatos/metabolismo , Isoflurano/administración & dosificación , Espectroscopía de Resonancia Magnética/métodos , Ácido Pirúvico/metabolismo , Administración por Inhalación , Anestésicos por Inhalación/administración & dosificación , Animales , Artefactos , Isótopos de Carbono/farmacocinética , Relación Dosis-Respuesta a Droga , Masculino , Tasa de Depuración Metabólica/efectos de los fármacos , Ratas , Ratas Wistar , Distribución Tisular/efectos de los fármacos
13.
NMR Biomed ; 26(12): 1680-7, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23904148

RESUMEN

Hyperpolarized (13)C MRS allows the in vivo assessment of pyruvate dehydrogenase complex (PDC) flux, which converts pyruvate to acetyl-coenzyme A (acetyl-CoA). [1-(13)C]pyruvate has been used to measure changes in cardiac PDC flux, with demonstrated increase in (13)C-bicarbonate production after dichloroacetate (DCA) administration. With [1-(13)C]pyruvate, the (13)C label is released as (13 CO2 /(13)C-bicarbonate, and, hence, does not allow us to follow the fate of acetyl-CoA. Pyruvate labeled in the C2 position has been used to track the (13)C label into the TCA (tricarboxylic acid) cycle and measure [5-(13)C]glutamate as well as study changes in [1-(13)C]acetylcarnitine with DCA and dobutamine. This work investigates changes in the metabolic fate of acetyl-CoA in response to metabolic interventions of DCA-induced increased PDC flux in the fed and fasted state, and increased cardiac workload with dobutamine in vivo in rat heart at two different pyruvate doses. DCA led to a modest increase in the (13)C labeling of [5-(13)C]glutamate, and a considerable increase in [1-(13)C]acetylcarnitine and [1,3-(13)C]acetoacetate peaks. Dobutamine resulted in an increased labeling of [2-(13)C]lactate, [2-(13)C]alanine and [5-(13)C]glutamate. The change in glutamate with dobutamine was observed using a high pyruvate dose but not with a low dose. The relative changes in the different metabolic products provide information about the relationship between PDC-mediated oxidation of pyruvate and its subsequent incorporation into the TCA cycle compared with other metabolic pathways. Using a high dose of pyruvate may provide an improved ability to observe changes in glutamate.


Asunto(s)
Espectroscopía de Resonancia Magnética , Miocardio/metabolismo , Ácido Pirúvico/metabolismo , Animales , Isótopos de Carbono , Ácido Dicloroacético/metabolismo , Dobutamina/metabolismo , Masculino , Ratas , Ratas Wistar , Factores de Tiempo
14.
NMR Biomed ; 26(6): 607-12, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23225495

RESUMEN

To date, measurements of the activity of aldehyde dehydrogenase-2 (ALDH2), a critical mitochondrial enzyme for the elimination of certain cytotoxic aldehydes in the body and a promising target for drug development, have been largely limited to in vitro methods. Recent advancements in MRS of hyperpolarized (13) C-labeled substrates have provided a method to detect and image in vivo metabolic pathways with signal-to-noise ratio gains greater than 10 000-fold over conventional MRS techniques. However aldehydes, because of their toxicity and short T1 relaxation times, are generally poor targets for such (13) C-labeled studies. In this work, we show that dynamic MRSI of hyperpolarized [1-(13) C]pyruvate and its conversion to [1-(13) C]lactate can provide an indirect in vivo measurement of ALDH2 activity via the concentration of NADH (nicotinamide adenine dinucleotide, reduced form), a co-factor common to both the reduction of pyruvate to lactate and the oxidation of acetaldehyde to acetate. Results from a rat liver ethanol model (n = 9) show that changes in (13) C-lactate labeling following the bolus injection of hyperpolarized pyruvate are highly correlated with changes in ALDH2 activity (R(2) = 0.76).


Asunto(s)
Aldehído Deshidrogenasa/metabolismo , Hígado/enzimología , Espectroscopía de Resonancia Magnética/métodos , Proteínas Mitocondriales/metabolismo , Ácido Pirúvico/metabolismo , Aldehído Deshidrogenasa/antagonistas & inhibidores , Aldehído Deshidrogenasa Mitocondrial , Animales , Isótopos de Carbono , Disulfiram/farmacología , Masculino , Proteínas Mitocondriales/antagonistas & inhibidores , Ratas , Ratas Wistar
15.
NMR Biomed ; 26(10): 1197-203, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23553852

RESUMEN

Hyperpolarized [1-(13) C]pyruvate ([1-(13) C]Pyr) has been used to assess metabolism in healthy and diseased states, focusing on the downstream labeling of lactate (Lac), bicarbonate and alanine. Although hyperpolarized [2-(13) C]Pyr, which retains the labeled carbon when Pyr is converted to acetyl-coenzyme A, has been used successfully to assess mitochondrial metabolism in the heart, the application of [2-(13) C]Pyr in the study of brain metabolism has been limited to date, with Lac being the only downstream metabolic product reported previously. In this study, single-time-point chemical shift imaging data were acquired from rat brain in vivo. [5-(13) C]Glutamate, [1-(13) C]acetylcarnitine and [1-(13) C]citrate were detected in addition to resonances from [2-(13) C]Pyr and [2-(13) C]Lac. Brain metabolism was further investigated by infusing dichloroacetate, which upregulates Pyr flux to acetyl-coenzyme A. After dichloroacetate administration, a 40% increase in [5-(13) C]glutamate from 0.014 ± 0.004 to 0.020 ± 0.006 (p = 0.02), primarily from brain, and a trend to higher citrate (0.002 ± 0.001 to 0.004 ± 0.002) were detected, whereas [1-(13) C]acetylcarnitine was increased in peripheral tissues. This study demonstrates, for the first time, that hyperpolarized [2-(13) C]Pyr can be used for the in vivo investigation of mitochondrial function and tricarboxylic acid cycle metabolism in brain.


Asunto(s)
Encéfalo/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Mitocondrias/metabolismo , Piruvatos/metabolismo , Animales , Isótopos de Carbono , Masculino , Redes y Vías Metabólicas , Ratas , Ratas Wistar , Factores de Tiempo
16.
J Magn Reson Open ; 16-172023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38046796

RESUMEN

In light of the growing interest in-vivo deuterium metabolic imaging, hyperpolarized 13C, 15N, 3He, and 129Xe imaging, as well as 31P spectroscopy and imaging in large animals on clinical MR scanners, we demonstrate the use of a (radio)frequency converter system to allow X-nuclear MR spectroscopy (MRS) and MR imaging (MRI) on standard clinical MRI scanners without multinuclear capability. This is not only an economical alternative to the multinuclear system (MNS) provided by the scanner vendors, but also overcomes the frequency bandwidth problem of some vendor-provided MNSs that prohibit users from applications with X-nuclei of low magnetogyric ratio, such as deuterium (6.536 MHz/Tesla) and 15N (-4.316 MHz/Tesla). Here we illustrate the design of the frequency converter system and demonstrate its feasibility for 31P (17.235 MHz/Tesla), 13C (10.708 MHz/Tesla), and 15N MRS and MRI on a clinical MRI scanner without vendor-provided multinuclear hardware.

17.
J Magn Reson Open ; 16-172023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38046795

RESUMEN

We report several inductively coupled RF coil designs that are very easy to construct, produce high signal-to-noise ratio (SNR) and high spatial resolution while accommodating life support, anesthesia and monitoring in small animals. Inductively coupled surface coils were designed for hyperpolarized 13 C MR spectroscopic imaging (MRSI) of mouse brain, with emphases on the simplicity of the circuit design, ease of use, whole-brain coverage, and high SNR. The simplest form was a resonant loop designed to crown the mouse head for a snug fit to achieve full coverage of the brain with high sensitivity when inductively coupled to a broadband pick-up coil. Here, we demonstrated the coil's performance in hyperpolarized 13 C MRSI of a normal mouse and a glioblastoma mouse model at 4.7 T. High SNR exceeding 70:1 was obtained in the brain with good spatial resolution (1.53 mm × 1.53 mm). Similar inductively coupled loop for other X-nuclei can be made very easily in a few minutes and achieve high performance, as demonstrated in 31 P spectroscopy. Similar design concept was expanded to splitable, inductively coupled volume coils for high-resolution proton MRI of marmoset at 3T and 9.4T, to easily accommodate head restraint, vital-sign monitoring, and anesthesia delivery.

18.
Mol Imaging Biol ; 25(2): 353-362, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35962301

RESUMEN

PURPOSE: New generation of receptor tyrosine kinase inhibitors (RTKIs) have shown to improve survival in many solid tumors. However, an imaging biomarker is needed for patient selection and prediction of treatment response. This study evaluates the use of quantitative changes of HER3 on 68 Ga-NOTA-HER3P1 PET/MRI for prediction of early response to pan-RTKIs in gastric cancer (GCa). PROCEDURES: GCa cell lines were evaluated for expression of RTKs, and downstream signaling pathways (AKT and MAPK). Cell viability was assessed following 24-72 h of treatment with 0.01-1 µmol/L of afatinib, a pan-RTKI. HER3-expressing afatinib-sensitive (NCI-N87) and resistant cells (SNU16) were selected for evaluation of changes in RTKs expression and downstream pathways, with 24-72 h of 0.1 µmol/L afatinib treatment. 68 Ga-NOTA-HER3P1 PET/MRI was performed in subcutaneous NCI-N87 and SNU16 xenografts (nu:nu, n = 12/group) at baseline and 4 days after afatinib treatment (10 mg/kg, PO, daily). Temporal changes in PET measures were correlated to HER3 expression in tumors, tumor growth rate, and treatment response. RESULTS: With afatinib therapy, NCI-N87 cells showed increased total HER3 expression, and reduction of other RTKs and downstream nodes within 72 h, while SNU16 cells showed no significant change in total HER3 and downstream nodes. 68 Ga-HER3P1 PET/MRI showed increased uptake in NCI-N87 and no significant change in SNU16 tumors (day 4 vs. baseline SUVmean: 3.8 ± 0.7 vs. 1.6 ± 0.6, p < 0.05 in NCI-N87, and 1.5 ± 0.7 vs. 1.7 ± 0.7, p > 0.05 in SNU16). These findings were in concordance with HER3 expression in histopathological analyses and tumor growth over 3 weeks of treatment (mean tumor volume in treated vs. control: 11 ± 17 mm3 vs. 293 ± 79 mm3, p < 0.001 in NCI-N87, and 238 ± 91 mm3 vs. 282 ± 35 mm3, p > 0.05 in SNU16). CONCLUSIONS: Quantitative changes in HER3 PET could be used to predict response to pan-RTKI within few days after initiation of treatment and can help with personalizing GCa management.


Asunto(s)
Neoplasias Gástricas , Humanos , Afatinib/farmacología , Neoplasias Gástricas/patología , Línea Celular Tumoral , Tomografía de Emisión de Positrones/métodos , Receptor ErbB-3
19.
Neuropsychopharmacology ; 48(5): 797-805, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35995971

RESUMEN

Glucose metabolism is impaired in brain aging and several neurological conditions. Beneficial effects of ketones have been reported in the context of protecting the aging brain, however, their neurophysiological effect is still largely uncharacterized, hurdling their development as a valid therapeutic option. In this report, we investigate the neurochemical effect of the acute administration of a ketone d-beta-hydroxybutyrate (D-ßHB) monoester in fasting healthy participants with ultrahigh-field proton magnetic resonance spectroscopy (MRS). In two within-subject metabolic intervention experiments, 7 T MRS data were obtained in fasting healthy participants (1) in the anterior cingulate cortex pre- and post-administration of D-ßHB (N = 16), and (2) in the posterior cingulate cortex pre- and post-administration of D-ßHB compared to active control glucose (N = 26). Effect of age and blood levels of D-ßHB and glucose were used to further explore the effect of D-ßHB and glucose on MRS metabolites. Results show that levels of GABA and Glu were significantly reduced in the anterior and posterior cortices after administration of D-ßHB. Importantly, the effect was specific to D-ßHB and not observed after administration of glucose. The magnitude of the effect on GABA and Glu was significantly predicted by older age and by elevation of blood levels of D-ßHB. Together, our results show that administration of ketones acutely impacts main inhibitory and excitatory transmitters in the whole fasting cortex, compared to normal energy substrate glucose. Critically, such effects have an increased magnitude in older age, suggesting an increased sensitivity to ketones with brain aging.


Asunto(s)
Ácido Glutámico , Giro del Cíngulo , Humanos , Adulto , Ácido 3-Hidroxibutírico/farmacología , Ácido Glutámico/metabolismo , Giro del Cíngulo/diagnóstico por imagen , Giro del Cíngulo/metabolismo , Cetonas , Espectroscopía de Protones por Resonancia Magnética , Glucosa , Ácido gamma-Aminobutírico
20.
J Magn Reson Open ; 16-172023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38090022

RESUMEN

Hyperpolarization chemistry based on reversible exchange of parahydrogen, also known as Signal Amplification By Reversible Exchange (SABRE), is a particularly simple approach to attain high levels of nuclear spin hyperpolarization, which can enhance NMR and MRI signals by many orders of magnitude. SABRE has received significant attention in the scientific community since its inception because of its relative experimental simplicity and its broad applicability to a wide range of molecules, however in vivo detection of molecular probes hyperpolarized by SABRE has remained elusive. Here we describe a first demonstration of SABRE-hyperpolarized contrast detected in vivo, specifically using hyperpolarized [1-13C]pyruvate. Biocompatible formulations of hyperpolarized [1-13C]pyruvate in, both, methanol-water mixtures, and ethanol-water mixtures followed by dilution with saline and catalyst filtration were prepared and injected into healthy Sprague Dawley and Wistar rats. Effective hyperpolarization-catalyst removal was performed with silica filters without major losses in hyperpolarization. Metabolic conversion of pyruvate to lactate, alanine, and bicarbonate was detected in vivo. Pyruvate-hydrate was also observed as minor byproduct. Measurements were performed on the liver and kidney at 4.7 T via time-resolved spectroscopy and chemical-shift-resolved MRI. In addition, whole-body metabolic measurements were obtained using a cryogen-free 1.5 T MRI system, illustrating the utility of combining lower-cost MRI systems with simple, low-cost hyperpolarization chemistry to develop safe, and scalable molecular imaging.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA