Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Genome Res ; 28(1): 75-87, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29208629

RESUMEN

Simultaneous sequencing of the genome and transcriptome at the single-cell level is a powerful tool for characterizing genomic and transcriptomic variation and revealing correlative relationships. However, it remains technically challenging to analyze both the genome and transcriptome in the same cell. Here, we report a novel method for simultaneous isolation of genomic DNA and total RNA (SIDR) from single cells, achieving high recovery rates with minimal cross-contamination, as is crucial for accurate description and integration of the single-cell genome and transcriptome. For reliable and efficient separation of genomic DNA and total RNA from single cells, the method uses hypotonic lysis to preserve nuclear lamina integrity and subsequently captures the cell lysate using antibody-conjugated magnetic microbeads. Evaluating the performance of this method using real-time PCR demonstrated that it efficiently recovered genomic DNA and total RNA. Thorough data quality assessments showed that DNA and RNA simultaneously fractionated by the SIDR method were suitable for genome and transcriptome sequencing analysis at the single-cell level. The integration of single-cell genome and transcriptome sequencing by SIDR (SIDR-seq) showed that genetic alterations, such as copy-number and single-nucleotide variations, were more accurately captured by single-cell SIDR-seq compared with conventional single-cell RNA-seq, although copy-number variations positively correlated with the corresponding gene expression levels. These results suggest that SIDR-seq is potentially a powerful tool to reveal genetic heterogeneity and phenotypic information inferred from gene expression patterns at the single-cell level.


Asunto(s)
ADN de Neoplasias , Secuenciación de Nucleótidos de Alto Rendimiento , Neoplasias , ARN Neoplásico , ADN de Neoplasias/genética , ADN de Neoplasias/aislamiento & purificación , Humanos , Células MCF-7 , Neoplasias/genética , Neoplasias/metabolismo , ARN Neoplásico/genética , ARN Neoplásico/aislamiento & purificación
2.
BMC Genomics ; 20(1): 216, 2019 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-30871467

RESUMEN

BACKGROUND: Target enrichment is a critical component of targeted deep next-generation sequencing for the cost-effective and sensitive detection of mutations, which is predominantly performed by either hybrid selection or PCR. Despite the advantages of efficient enrichment, PCR-based methods preclude the identification of PCR duplicates and their subsequent removal. Recently, this limitation was overcome by assigning a unique molecular identifier(UMI) to each template molecule. Currently, several commercial library construction kits based on PCR enrichment are available for UMIs, but there have been no systematic studies to compare their performances. In this study, we evaluated and compared the performances of five commercial library kits from four vendors: the Archer® Reveal ctDNA™ 28 Kit, NEBNext Direct® Cancer HotSpot Panel, Nugen Ovation® Custom Target Enrichment System, Qiagen Human Comprehensive Cancer Panel(HCCP), and Qiagen Human Actionable Solid Tumor Panel(HASTP). RESULTS: We evaluated and compared the performances of the five kits using 50 ng of genomic DNA for the library construction in terms of the library complexity, coverage uniformity, and errors in the UMIs. While the duplicate rates for all kits were dramatically decreased by identifying unique molecules with UMIs, the Qiagen HASTP achieved the highest library complexity based on the depth of unique coverage indicating superb library construction efficiency. Regarding the coverage uniformity, the kits from Nugen and NEB performed the best followed by the kits from Qiagen. We also analyzed the UMIs, including errors, which allowed us to adjust the depth of unique coverage and the length required for sufficient complexity. Based on these comparisons, we selected the Qiagen HASTP for further performance evaluations. The targeted deep sequencing method based on PCR target enrichment combined with UMI tagging sensitively detected mutations present at a frequency as low as 1% using 6.25 ng of human genomic DNA as the starting material. CONCLUSION: This study is the first systematic evaluation of commercial library construction kits for PCR-based targeted deep sequencing utilizing UMIs. Because the kits displayed significant variability in different quality metrics, our study offers a practical guideline for researchers to choose appropriate options for PCR-based targeted sequencing and useful benchmark data for evaluating new kits.


Asunto(s)
Biomarcadores/análisis , ADN/análisis , Biblioteca de Genes , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Reacción en Cadena de la Polimerasa/métodos , Juego de Reactivos para Diagnóstico/normas , ADN/aislamiento & purificación , Secuenciación de Nucleótidos de Alto Rendimiento/normas , Humanos , Reacción en Cadena de la Polimerasa/normas
3.
Anal Chem ; 86(8): 3735-42, 2014 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-24641782

RESUMEN

Full automation with high purity for circulating tumor cell (CTC) isolation has been regarded as a key goal to make CTC analysis a "bench-to-bedside" technology. Here, we have developed a novel centrifugal microfluidic platform that can isolate the rare cells from a large volume of whole blood. To isolate CTCs from whole blood, we introduce a disc device having the biggest sample capacity as well as manipulating blood cells for the first time. The fully automated disc platform could handle 5 mL of blood by designing the blood chamber having a triangular obstacle structure (TOS) with lateral direction. To guarantee high purity that enables molecular analysis with the rare cells, CTCs were bound to the microbeads covered with anti-EpCAM to discriminate density between CTCs and blood cells and the CTCs being heavier than blood cells were only settled under a density gradient medium (DGM) layer. To understand the movement of CTCs under centrifugal force, we performed computational fluid dynamics simulation and found that their major trajectories were the boundary walls of the DGM chamber, thereby optimizing the chamber design. After whole blood was inserted into the blood chamber of the disc platform, size- and density-amplified cancer cells were isolated within 78 min, with minimal contamination as much as approximately 12 leukocytes per milliliter. As a model of molecular analysis toward personalized cancer treatment, we performed epidermal growth factor receptor (EGFR) mutation analysis with HCC827 lung cancer cells and the isolated cells were then successfully detected for the mutation by PCR clamping and direct sequencing.


Asunto(s)
Separación Celular/instrumentación , Dispositivos Laboratorio en un Chip , Células Neoplásicas Circulantes/patología , Automatización , Células Sanguíneas , Línea Celular Tumoral , Centrifugación por Gradiente de Densidad , Análisis Mutacional de ADN , Receptores ErbB/genética , Humanos , Microfluídica , Reacción en Cadena de la Polimerasa , Medicina de Precisión
4.
Bioconjug Chem ; 23(10): 2114-20, 2012 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-23025585

RESUMEN

New zwitterionic polymer-coated immunoaffinity beads were developed to resist nonspecific protein adsorption from undiluted human serum for diagnostic applications of exosomes. A zwitterionic sulfobetaine monomer with an amine functional group was employed for simple surface chemistry and antifouling properties. An exosomal biomarker protein, epithelial cell adhesion molecule (EpCAM), was selected as a target molecule in this work. The beads were coated with polyacrylic acids (PAA) for increasing biorecognition sites, and protein G was then conjugated with carboxylic acid groups on the surfaces for controlling EpCAM antibody orientation. The remaining free carboxylic acid groups were modified with sulfobetaine moieties, and anti-EpCAM antibody was finally introduced. The amount of anti-EpCAM on the beads was increased by 40% when compared with PAA-uncoated beads. The surfaces of the beads exhibited near-net-zero charge, and nonspecific protein adsorption was effectively suppressed by sulfobetaine moieties. EpCAM was captured from undiluted human serum with almost the same degree of efficiency as from PBS buffer solution using the newly developed immunoaffinity beads.


Asunto(s)
Resinas Acrílicas/química , Anticuerpos/química , Fraccionamiento Celular/métodos , Exosomas/metabolismo , Adsorción , Anticuerpos/inmunología , Antígenos de Neoplasias/inmunología , Moléculas de Adhesión Celular/inmunología , Molécula de Adhesión Celular Epitelial , Humanos , Imanes/química , Microesferas , Propiedades de Superficie
5.
Anal Biochem ; 431(2): 96-8, 2012 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-22982508

RESUMEN

A direct extraction method was developed for exosomal microRNAs. After isolation of exosomes from human serum by immunoaffinity magnetic beads, microRNAs were extracted by just mixing beads with a lysis solution and heating without further purification. The lysis solution was composed of a nonionic detergent and salt (NaCl). The concentration of each component was optimized to maximize lysis efficiency and to inhibit adsorption of extracted microRNAs on beads. MicroRNAs extracted by this method could be quantitatively analyzed by qRT-PCR, indicating that the method could replace conventional methods for extracting microRNAs from immunobead-captured exosomes.


Asunto(s)
Exosomas , Separación Inmunomagnética/métodos , MicroARNs/aislamiento & purificación , Exosomas/metabolismo , Exosomas/ultraestructura , Humanos , MicroARNs/sangre
6.
Exp Mol Med ; 54(12): 2128-2134, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36460793

RESUMEN

Single-cell ribonucleic acid (RNA) sequencing (scRNA-seq) is an effective technique for estimating the cellular composition and transcriptional profiles of individual cells from fresh tissue. Single-nucleus RNA sequencing (snRNA-seq) is necessary to perform this type of analysis in frozen or difficult-to-dissociate tissues, which cannot be subjected to scRNA-seq. This difference in the state of tissues leads to variation in cell-type distributions among each platform. To identify the characteristics of these methods and their differences, scRNA-seq and snRNA-seq were performed in parallel for colon and liver tissues. The two platforms revealed similar diversity but different proportions of cell types in matched tissues. The proportions of epithelial cells in the colon and hepatocytes in the liver were relatively high in snRNA-seq and that of immune cells was relatively high in scRNA-seq. This difference could be explained by variations in the expression scores of adhesion genes due to the disruption of the cytoplasmic contents during scRNA-seq. The enrichment of epithelial cells in the colon resulted in a discrepancy in the differentiation of epithelial cells. This enrichment was also well matched with the images of hematoxylin and eosin staining and the estimated distribution of cell types in bulk RNA sequencing. These results showed that snRNA-seq could be used to analyze tissues that cannot be subjected to scRNA-seq and provides more information in specific cell type analysis.


Asunto(s)
Perfilación de la Expresión Génica , ARN , ARN/genética , Perfilación de la Expresión Génica/métodos , Análisis de Secuencia de ARN/métodos , ARN Nuclear Pequeño/metabolismo , Núcleo Celular/metabolismo
7.
Sci Rep ; 10(1): 20343, 2020 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-33230163

RESUMEN

The use of precision medicine for chemotherapy requires the individualization of the therapeutic regimen for each patient. This approach improves treatment efficacy and reduces the probability of administering ineffective drugs. To ensure accurate decision-making in a timely manner, anticancer drug efficacy tests must be performed within a short timeframe using a small number of cancer cells. These requirements can be satisfied via microfluidics-based drug screening platforms, which are composed of complex fluidic channels and closed systems. Owing to their complexity, skilled manipulation is required. In this study, we developed a microfluidic platform, to accurately perform multiple drug efficacy tests using a small number of cells, which can be conducted via simple manipulation. As it is a small, open-chamber system, a minimal number of cells could be loaded through simple pipetting. Furthermore, the extracellular matrix gel inside the chamber provides an in vivo-like environment that enables the localized delivery of the drugs to spontaneously diffuse from the channels underneath the chamber without a pump, thereby efficiently and robustly testing the efficacy and resistance of multiple drugs. We demonstrated that this platform enabled the rapid and facile testing of multiple drugs using a small number of cells (~ 10,000) over a short period of time (~ 2 days). These results provide the possibility of using this powerful platform for selecting therapeutic medication, developing new drugs, and delivering personalized medicine to patients.


Asunto(s)
Antineoplásicos/farmacología , Evaluación Preclínica de Medicamentos/métodos , Dispositivos Laboratorio en un Chip , Microfluídica/instrumentación , Microfluídica/métodos , Supervivencia Celular/efectos de los fármacos , Humanos , Células K562 , Células MCF-7 , Medicina de Precisión/métodos
8.
Lab Chip ; 18(5): 775-784, 2018 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-29423464

RESUMEN

Single-cell RNA-seq reveals the cellular heterogeneity inherent in the population of cells, which is very important in many clinical and research applications. Recent advances in droplet microfluidics have achieved the automatic isolation, lysis, and labeling of single cells in droplet compartments without complex instrumentation. However, barcoding errors occurring in the cell encapsulation process because of the multiple-beads-in-droplet and insufficient throughput because of the low concentration of beads for avoiding multiple-beads-in-a-droplet remain important challenges for precise and efficient expression profiling of single cells. In this study, we developed a new droplet-based microfluidic platform that significantly improved the throughput while reducing barcoding errors through deterministic encapsulation of inertially ordered beads. Highly concentrated beads containing oligonucleotide barcodes were spontaneously ordered in a spiral channel by an inertial effect, which were in turn encapsulated in droplets one-by-one, while cells were simultaneously encapsulated in the droplets. The deterministic encapsulation of beads resulted in a high fraction of single-bead-in-a-droplet and rare multiple-beads-in-a-droplet although the bead concentration increased to 1000 µl-1, which diminished barcoding errors and enabled accurate high-throughput barcoding. We successfully validated our device with single-cell RNA-seq. In addition, we found that multiple-beads-in-a-droplet, generated using a normal Drop-Seq device with a high concentration of beads, underestimated transcript numbers and overestimated cell numbers. This accurate high-throughput platform can expand the capability and practicality of Drop-Seq in single-cell analysis.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento , Microfluídica , Análisis de Secuencia de ARN , Análisis de la Célula Individual , Animales , Células HEK293 , Humanos , Células K562 , Ratones , Células 3T3 NIH , Tamaño de la Partícula , Propiedades de Superficie
9.
Biomaterials ; 75: 271-278, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26513419

RESUMEN

Efficient isolation of circulating tumor cells (CTCs) from whole blood is a major challenge for the clinical application of CTCs. Here, we report an efficient method to isolate CTCs from whole blood using highly dense and transparent silica microbeads. The surfaces of silica microbeads were fully covered with an antibody to capture CTCs, and blocked by zwitterionic moieties to prevent the non-specific adsorption of blood cells. Owing to the high density of the silica microbeads, the complexation of CTCs with silica microbeads resulted in the efficient sedimentation of CTC-microbead complexes, which enabled their discrimination from other blood cells in density gradient media. Model CTCs (MCF-7, HCC827, and SHP-77) with various levels of epithelial cell adhesion molecule (EpCAM) were isolated efficiently, especially those with low EpCAM expression (SHP-77). Moreover, the transparency of silica microbeads enabled CTCs to be clearly identified without interference caused by microbeads. The improved sensitivity resulted in increased CTC recovery from patient samples compared with the FDA-approved CellSearch system (14/15 using our method; 5/15 using the CellSearch system). These results indicate that the isolation method described in this report constitutes a powerful tool for the isolation of CTCs from whole blood, which has important applications in clinical practice.


Asunto(s)
Separación Celular/métodos , Microesferas , Células Neoplásicas Circulantes/patología , Fenómenos Ópticos , Dióxido de Silicio/química , Antígenos de Neoplasias/metabolismo , Moléculas de Adhesión Celular/metabolismo , Línea Celular Tumoral , Molécula de Adhesión Celular Epitelial , Humanos , Fenómenos Magnéticos
10.
Sci Rep ; 6: 37392, 2016 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-27892470

RESUMEN

Efficient isolation and genetic analysis of circulating tumor cells (CTCs) from cancer patients' blood is a critical step for clinical applications using CTCs. Here, we report a novel CTC-isolation method and subsequent genetic analysis. CTCs from the blood were complexed with magnetic beads coated with antibodies against the epithelial cell adhesion molecule (EpCAM) and separated vertically on a density-gradient medium in a modified well-plate. The recovery rate of model CTCs was reasonable and the cell purity was enhanced dramatically when compared to those parameters obtained using a conventional magnetic isolation method. CTCs were recovered from an increased number of patient samples using our magnetic system vs. the FDA-approved CellSearch system (100% vs. 33%, respectively). In 8 of 13 cases, targeted deep sequencing analysis of CTCs revealed private point mutations present in CTCs but not in matched tumor samples and white blood cells (WBCs), which was also validated by droplet digital PCR. Copy-number alterations in CTCs were also observed in the corresponding tumor tissues for some patients. In this report, we showed that CTCs isolated by the EpCAM-based method had complex and diverse genetic features that were similar to those of tumor samples in some, but not all, cases.


Asunto(s)
Antígenos de Neoplasias/genética , Molécula de Adhesión Celular Epitelial/genética , Separación Inmunomagnética/métodos , Neoplasias Pulmonares/diagnóstico , Proteínas de Neoplasias/genética , Células Neoplásicas Circulantes/metabolismo , Alelos , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/metabolismo , Antígenos de Neoplasias/metabolismo , Línea Celular Tumoral , Variaciones en el Número de Copia de ADN , Molécula de Adhesión Celular Epitelial/metabolismo , Expresión Génica , Frecuencia de los Genes , Humanos , Separación Inmunomagnética/instrumentación , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patología , Proteínas de Neoplasias/metabolismo , Células Neoplásicas Circulantes/patología , Mutación Puntual , Unión Proteica
11.
Org Lett ; 4(23): 4155-8, 2002 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-12423110

RESUMEN

A protein-cleaving catalyst specific for a disease-related protein can be used as a catalytic drug. As the first protein-cleaving catalyst selective for a protein substrate, a catalyst for myoglobin was designed by attaching Cu(II) or Co(III) complex of cyclen to a binding site searched by a combinatorial method using peptide nucleic acid monomers as building units. [reaction: see text]


Asunto(s)
Proteínas/química , Secuencia de Bases , Sitios de Unión , Catálisis , Técnicas Químicas Combinatorias/métodos , Indicadores y Reactivos , Cinética , Ácidos Nucleicos de Péptidos/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Especificidad por Sustrato
12.
J Am Chem Soc ; 125(47): 14580-9, 2003 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-14624608

RESUMEN

Mononuclear, dinuclear, and tetranuclear artificial metalloproteases were prepared by attaching respective catalytic modules containing the Cu(II) complex of cyclen (Cu(II)Cyc) to a derivative of cross-linked polystyrene. The polymeric artificial metalloproteases effectively cleaved peptide bonds of myoglobin (Mb) by hydrolysis. The proteolytic activity increased considerably as the catalytic group density was raised: the ratio of k(cat)/K(m) was 1:13:100 for the mono-, di-, and tetranuclear catalysts. In the degradation of Mb by the dinuclear catalyst, two pairs of intermediate proteins accumulated. One of the two initial cleavage sites leading to the formation of the protein fragments is identified as Gln(91)-Ser(92) and the other is suggested as Ala(94)-Thr(95). On the basis of a molecular modeling study by using the X-ray crystallographic structure of Mb, the site-selectivity is attributed to anchorage of one Cu(II)Cyc unit of the catalytic module to a heme carboxylate of Mb. The high site selectivity for the initial cleavage of a protein substrate and mechanistic analysis of the catalytic action are unprecedented for polymeric artificial enzymes.


Asunto(s)
Metaloproteasas/química , Mioglobina/química , Animales , Materiales Biomiméticos/síntesis química , Materiales Biomiméticos/química , Materiales Biomiméticos/metabolismo , Catálisis , Cromatografía Líquida de Alta Presión , Cobre/química , Caballos , Concentración de Iones de Hidrógeno , Hidrólisis , Cinética , Metaloproteasas/síntesis química , Metaloproteasas/metabolismo , Modelos Moleculares , Mioglobina/metabolismo , Compuestos Organometálicos/síntesis química , Compuestos Organometálicos/química , Compuestos Organometálicos/metabolismo , Conformación Proteica , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Relación Estructura-Actividad
13.
Bioorg Med Chem ; 11(13): 2901-10, 2003 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-12788360

RESUMEN

A protein-cleaving catalyst highly selective for a disease-related protein can be used as a catalytic drug. As the first protein-cleaving catalyst selective for a protein substrate, a catalyst for myoglobin (Mb) was designed by attaching the Cu(II) or Co(III) complex of cyclen to a binding site searched by a combinatorial method using peptide nucleic acid monomers as building units. Various linkers were inserted between the catalytic Co(III) center and the binding site of the Mb-cleaving catalyst. Kinetic data revealed catalytic turnover of the Mb cleavage by the Cu(II) or Co(III) complex. MALDI-TOF MS revealed cleavage of the polypeptide backbone of Mb at selected positions. N-Terminal sequencing of the cleavage products identified the cleavage site and provided evidence for the hydrolytic nature of the Mb cleavage. Various chelating ligands were tested as the ligand for the Co(III) center of the Mb-cleaving catalyst. Among the nine chelating ligands examined, only cyclen and its triaza-monooxo analogue manifested catalytic activity.


Asunto(s)
Endopeptidasas/síntesis química , Endopeptidasas/farmacología , Imitación Molecular , Mioglobina/efectos de los fármacos , Proteínas/efectos de los fármacos , Sitios de Unión , Catálisis , Dominio Catalítico , Cobalto/química , Técnicas Químicas Combinatorias , Cinética , Mioglobina/metabolismo , Proteínas/metabolismo , Especificidad por Sustrato
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA