Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Clin Gastroenterol Hepatol ; 22(4): 878-885.e2, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37743036

RESUMEN

BACKGROUND & AIMS: An increasing burden on health care resources has resulted in a backlog of individuals requiring colonoscopy, with delays in surveillance possibly detrimental for individuals at increased risk of colorectal cancer (CRC). This study investigated the use of a 2-sample fecal immunochemical test (FIT) to establish those most likely to have advanced neoplasia (AN) and in need of prioritized surveillance colonoscopy. METHODS: This was a prospective study conducted in the tertiary care setting. Participants completed a 2-sample FIT (OC-Sensor, Eiken Chemical Company) within 90 days of surveillance colonoscopy. The sensitivity of FIT for detection of AN (CRC or advanced adenoma) in moderate- and high-risk individuals was determined at fecal hemoglobin thresholds between 2 and 80 µg/g feces. RESULTS: A total of 766 patients were included (median age, 66.1 years [interquartile range, 58.1-72.9]; 49.9% male), with AN detected in 8.6% (66/766, including 5 CRC). For moderate-risk individuals (with prior history of adenoma or a significant family history of CRC), sensitivity of FIT for AN ranged from 73.5% at 2 µg/g feces, to 10.2% at 80 µg/g feces. For high-risk conditions (confirmed/suspected genetic syndromes or prior CRC), sensitivity of FIT was similar, ranging from 70.6% at the lowest positivity threshold of 2 µg/g feces, to 11.8% at 80 µg/g feces. Independent variables in the whole cohort for association with detection of AN at surveillance colonoscopy were age (odds ratio, 1.03; 95% confidence interval, 1.00-1.06) and FIT hemoglobin result ≥10 µg/g feces (odds ratio, 1.81; 95% confidence interval, 1.04-3.16). CONCLUSIONS: The use of FIT before surveillance colonoscopy provides clinicians with insights into the risk of AN. This raises the possibility of a method to triage individuals, facilitating the more efficient management of endoscopic resources.


Asunto(s)
Adenoma , Neoplasias Colorrectales , Humanos , Masculino , Anciano , Femenino , Estudios Prospectivos , Neoplasias Colorrectales/diagnóstico , Detección Precoz del Cáncer/métodos , Colonoscopía , Sangre Oculta , Heces/química , Hemoglobinas/análisis , Adenoma/diagnóstico
2.
Cancer Causes Control ; 35(2): 347-357, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37747615

RESUMEN

PURPOSE: To compare the sensitivity and discriminant validity of generic and cancer-specific measures for assessing health-related quality of life (HRQoL) for individuals undergoing diagnostic or surveillance colonoscopy for colorectal cancer. METHODS: HRQoL was assessed using EQ-5D-5L (generic), and EORTC QLQ-C30 (cancer-specific) scales, 14 days after (baseline) and one-year following colonoscopy (follow-up). Utility scores were calculated by mapping EORTC-QLQ-C30 onto QLU-C10D. Differences between participants with different indications for colonoscopy (positive faecal occult blood test (FOBT), surveillance, or symptoms) and colonoscopy findings (no polyps, polyps, or cancer) were tested using Wilcoxon-Mann-Whitney and Kruskal-Wallis H tests. Sensitivity was assessed by calculating the ceiling effects (proportion reporting the best possible level). RESULTS: 246 adults completed the survey, including those undergoing colonoscopy for symptoms (n = 87), positive FOBT (n = 92) or surveillance (n = 67). Those with symptoms had the lowest HRQoL at both baseline and follow-up, with differences observed within the HRQoL domains/areas of role function, appetite loss and bowel function on the QLU-C10D. No differences were found in HRQoL when stratified by findings at colonoscopy with both measures or when comparing baseline and follow-up responses. Participants reporting full health with EQ-5D-5L (21% at baseline and 16% at follow-up) still had problems on the QLU-C10D, with fatigue and sleep at baseline and with role function and fatigue at follow-up. CONCLUSION: Patients undergoing colonoscopy for symptoms had lower HRQoL compared to surveillance or positive FOBT. The cancer-specific QLU-C10D was more sensitive and had greater discriminant ability between patients undergoing colonoscopy for different indications.


Asunto(s)
Neoplasias , Calidad de Vida , Adulto , Humanos , Encuestas y Cuestionarios , Fatiga/diagnóstico
3.
Biomarkers ; 29(4): 194-204, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38644767

RESUMEN

INTRODUCTION: Methylated circulating tumour DNA (ctDNA) blood tests for BCAT1/IKZF1 (COLVERA) and SEPT9 (Epi proColon) are used to detect colorectal cancer (CRC). However, there are no ctDNA assays approved for other gastrointestinal adenocarcinomas. We aimed to characterize BCAT1, IKZF1 and SEPT9 methylation in different gastrointestinal adenocarcinoma and non-gastrointestinal tumours to determine if these validated CRC biomarkers might be useful for pan-gastrointestinal adenocarcinoma detection. METHODS: Tissue DNA methylation data from colorectal (COAD, READ), gastroesophageal (ESCA, STAD), pancreatic (PAAD) and cholangiocarcinoma (CHOL) adenocarcinoma cohorts within The Cancer Genome Atlas were used for differential methylation analyses. Clinicodemographic predictors of BCAT1, IKZF1 and SEPT9 methylation, and the selectivity of hypermethylated BCAT1, IKZF1 and SEPT9 for colorectal adenocarcinomas in comparison to other cancers were each explored with beta regression. RESULTS: Hypermethylated BCAT1, IKZF1 and SEPT9 were each differentially methylated in colorectal and gastroesophageal adenocarcinomas. IKZF1 was differentially methylated in pancreatic adenocarcinoma. Hypermethylated DNA biomarkers BCAT1, IKZF1 and SEPT9 were largely stable across different stages of disease and were highly selective for gastrointestinal adenocarcinomas relative to other cancer types. DISCUSSION: Existing CRC methylated ctDNA blood tests for BCAT1/IKZF1 and SEPT9 might be usefully repurposed for use in other gastrointestinal adenocarcinomas and warrant further prospective ctDNA studies.


Asunto(s)
Adenocarcinoma , Biomarcadores de Tumor , Metilación de ADN , Neoplasias Gastrointestinales , Factor de Transcripción Ikaros , Septinas , Humanos , Septinas/genética , Septinas/sangre , Factor de Transcripción Ikaros/genética , Biomarcadores de Tumor/genética , Biomarcadores de Tumor/sangre , Adenocarcinoma/genética , Adenocarcinoma/diagnóstico , Adenocarcinoma/sangre , Neoplasias Gastrointestinales/genética , Neoplasias Gastrointestinales/diagnóstico , Neoplasias Gastrointestinales/sangre , Masculino , ADN Tumoral Circulante/genética , ADN Tumoral Circulante/sangre , Femenino , Neoplasias Colorrectales/genética , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/sangre , Colangiocarcinoma/genética , Colangiocarcinoma/diagnóstico , Colangiocarcinoma/sangre , Persona de Mediana Edad , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/sangre
4.
Artículo en Inglés | MEDLINE | ID: mdl-38430185

RESUMEN

BACKGROUND AND AIM: Colorectal cancer (CRC) screening programs are most effective at reducing disease incidence and mortality through sustained screening participation. A novel blood test modality is being explored for CRC screening, but it is unclear whether it will provide sustained screening participation. This study aimed to investigate whether a circulating tumor DNA (ctDNA) blood test improved CRC screening re-participation when compared with a fecal immunochemical test (FIT) and to define the predictors of sustained CRC screening in an Australian population. METHODS: South Australians who initially participated in CRC screening using a ctDNA blood test (n = 36) or FIT (n = 547) were offered the same CRC screening test approximately 2 years later through an extended phase of a randomized controlled trial. Surveys collected demographic, psychosocial, and clinical information. Predictors of CRC screening re-participation were explored using chi-square, Wilcoxon tests, and logistic regression. RESULTS: Participants offered a second ctDNA blood test were equally likely to re-participate in CRC screening as those who completed a FIT in the first round and who were offered the same test (61% vs 66% re-participation respectively, P = 0.6). CRC fatalism, health activation, and self-efficacy were associated with repeated screening participation. Test awareness was predictive of repeated FIT-based CRC screening. CONCLUSIONS: Targeted interventions to improve CRC screening awareness and increase patient health activation may improve CRC screening adherence. A ctDNA blood test may be a suitable CRC screening option to maintain CRC screening adherence in people who do not participate in screening with FIT.

5.
Dig Dis Sci ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38753241

RESUMEN

BACKGROUND: The fecal immunochemical test (FIT) is widely used in colorectal cancer (CRC) screening, but limited data exist for its application in individuals at above-average risk for CRC who complete surveillance colonoscopies. AIM: To assess the accuracy, acceptability, and effectiveness of FIT in the interval between surveillance colonoscopies, for predicting advanced neoplasia (advanced adenoma or CRC) at the next colonoscopy. METHODS: Individuals enrolled in an Australian surveillance program were included. Diagnostic accuracy was determined for 614 individuals completing a two-sample FIT (OC-Sensor) ≤ 3 months preceding surveillance colonoscopy. 386 Individuals were surveyed to assess acceptability of interval FIT. Additionally, a retrospective analysis was performed on 7331 individuals offered interval FIT between colonoscopies, where a positive FIT (≥ 20 µg hemoglobin/g feces) triggered an early colonoscopy. Associations between interval FIT results and advanced neoplasia were determined using regression analysis. RESULTS: FIT detected CRC and advanced adenoma with sensitivities of 60.0% (3/5) and 27.1% (35/129), respectively. Most (89.1%, 344/386) survey respondents preferred completing interval FIT every 1-2 years. The detection rate of interval FIT for advanced neoplasia decreased with increasing FIT completion. Individuals returning a positive FIT had a higher risk of advanced neoplasia than those who did not complete FIT. Positive interval FIT reduced time-to-diagnosis for CRC and advanced adenoma by a median of 30 and 20 months, respectively. CONCLUSION: Interval FIT was well accepted and enabled earlier detection of advanced neoplasia in individuals at above-average risk of CRC. Given that interval FIT predicts advanced neoplasia, it may be used to personalize surveillance colonoscopy intervals.

6.
Gut ; 72(10): 1904-1918, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37463757

RESUMEN

OBJECTIVE: New screening tests for colorectal cancer (CRC) are rapidly emerging. Conducting trials with mortality reduction as the end point supporting their adoption is challenging. We re-examined the principles underlying evaluation of new non-invasive tests in view of technological developments and identification of new biomarkers. DESIGN: A formal consensus approach involving a multidisciplinary expert panel revised eight previously established principles. RESULTS: Twelve newly stated principles emerged. Effectiveness of a new test can be evaluated by comparison with a proven comparator non-invasive test. The faecal immunochemical test is now considered the appropriate comparator, while colonoscopy remains the diagnostic standard. For a new test to be able to meet differing screening goals and regulatory requirements, flexibility to adjust its positivity threshold is desirable. A rigorous and efficient four-phased approach is proposed, commencing with small studies assessing the test's ability to discriminate between CRC and non-cancer states (phase I), followed by prospective estimation of accuracy across the continuum of neoplastic lesions in neoplasia-enriched populations (phase II). If these show promise, a provisional test positivity threshold is set before evaluation in typical screening populations. Phase III prospective studies determine single round intention-to-screen programme outcomes and confirm the test positivity threshold. Phase IV studies involve evaluation over repeated screening rounds with monitoring for missed lesions. Phases III and IV findings will provide the real-world data required to model test impact on CRC mortality and incidence. CONCLUSION: New non-invasive tests can be efficiently evaluated by a rigorous phased comparative approach, generating data from unbiased populations that inform predictions of their health impact.


Asunto(s)
Neoplasias Colorrectales , Tamizaje Masivo , Humanos , Estudios Prospectivos , Detección Precoz del Cáncer , Neoplasias Colorrectales/epidemiología , Colonoscopía , Sangre Oculta , Heces
7.
Clin Gastroenterol Hepatol ; 21(9): 2389-2398.e2, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36610499

RESUMEN

BACKGROUND & AIMS: In above-average-risk individuals undergoing colonoscopy-based surveillance for colorectal cancer (CRC), screening with fecal immunochemical tests (FIT) between colonoscopies might facilitate personalization of surveillance intervals. Because a negative FIT is associated with a reduced risk for CRC, we examined the relationship between number of rounds of negative FIT and risk for advanced neoplasia in individuals undergoing surveillance colonoscopy. METHODS: We conducted a retrospective cohort study on 4021 surveillance intervals in 3369 individuals (50-74 years), who had completed a 2-sample FIT between colonoscopies, from 1 to 4 rounds at 1-2 yearly intervals, each with a negative result (<20 µg hemoglobin/g feces). Incidence of advanced neoplasia (CRC or advanced adenoma) was determined at the follow-up colonoscopy. Competing-risk regression was used to assess the association between multiple negative FIT results and the risk of advanced neoplasia within 2 years. RESULTS: The incidence of advanced neoplasia in the cohort was 9.9% and decreased with increasing numbers of rounds of negative FIT results: 11.1% after 1 negative FIT to 5.7% after 4 negative FIT. The risk of advanced neoplasia was significantly lower in participants with 3 (subdistribution hazard ratio, 0.50; 95% confidence interval, 0.24-0.97) and 4 (subdistribution hazard ratio, 0.33; 95% confidence interval, 0.15-0.73) rounds of negative FIT compared with only 1 negative FIT. CONCLUSIONS: There was a low risk of advanced neoplasia after multiple rounds of negative FIT in above-average-risk people undergoing surveillance with no neoplasia or nonadvanced adenoma at prior colonoscopy. This supports the use of interval FIT to personalize surveillance by lengthening colonoscopy intervals following multiple negative FIT results.


Asunto(s)
Adenoma , Neoplasias Colorrectales , Humanos , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/epidemiología , Estudios Retrospectivos , Colonoscopía , Adenoma/diagnóstico , Adenoma/epidemiología , Sangre Oculta , Heces , Detección Precoz del Cáncer/métodos , Tamizaje Masivo/métodos
8.
Clin Chem ; 2023 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-37232052

RESUMEN

BACKGROUND: Fecal immunochemical tests (FITs) are widely used for colorectal cancer (CRC) screening; however, high ambient temperatures were found to reduce test accuracy. More recently, proprietary globin stabilizers were added to FIT sample buffers to prevent temperature-associated hemoglobin (Hb) degradation, but their effectiveness remains uncertain. We aimed to determine the impact of high temperature (>30°C) on OC-Sensor FIT Hb concentration with current FITs, characterize FIT temperatures during mail transit, and determine impact of ambient temperature on FIT Hb concentration using data from a CRC screening program. METHODS: FITs were analyzed for Hb concentration after in vitro incubation at different temperatures. Data loggers packaged alongside FITs measured temperatures during mail transit. Separately, screening program participants completed and mailed FITs to the laboratory for Hb analysis. Regression analyses compared the impact of environmental variables on FIT temperatures and separately on FIT sample Hb concentration. RESULTS: In vitro incubation at 30 to 35°C reduced FIT Hb concentration after >4 days. During mail transit, maximum FIT temperature averaged 6.4°C above maximum ambient temperature, but exposure to temperature above 30°C was for less than 24 hours. Screening program data showed no association between FIT Hb concentration and maximum ambient temperatures. CONCLUSIONS: Although FIT samples are exposed to elevated temperatures during mail transit, this is brief and does not significantly reduce FIT Hb concentration. These data support continuation of CRC screening during warm weather with modern FITs with a stabilizing agent when mail delivery is ≤4 days.

9.
Int J Colorectal Dis ; 38(1): 201, 2023 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-37490150

RESUMEN

PURPOSE: There is increasing demand for colorectal cancer (CRC) surveillance, but healthcare capacity is limited. The burden on colonoscopy resources could be reduced by personalizing surveillance frequency using the fecal immunochemical test (FIT). This study will determine the safety, cost-effectiveness, and patient acceptance of using FIT to extend surveillance colonoscopy intervals for individuals at elevated risk of CRC. METHODS: This multicenter, prospective, randomized controlled trial will invite participants who are scheduled for surveillance colonoscopy (due to a personal history of adenomas or a family history of CRC) and who have returned a low fecal hemoglobin (< 2 µg Hb/g feces; F-Hb) using a two-sample FIT (OC Sensor, Eiken Chemical Company) in the prior 3 years. A total of 1344 individuals will be randomized to either surveillance colonoscopy as scheduled or delayed by 1 or 2 years for individuals originally recommended a 3- or 5-year surveillance interval, respectively. The primary endpoint is incidence of advanced neoplasia (advanced adenoma and/or CRC). Secondary endpoints include cost-effectiveness and consumer acceptability of extending surveillance intervals, determined using surveys and discrete choice experiments. CONCLUSION: This study will establish the safety, cost-effectiveness, and acceptability of utilizing a low FIT Hb result to extend colonoscopy surveillance intervals in a cohort at elevated risk for CRC. This personalized approach to CRC surveillance will lead to a reduction in unnecessary colonoscopies, increases in healthcare savings, and a better patient experience.  TRIAL REGISTRATION: Registration was approved on December 9, 2019 with the Australian New Zealand Clinical Trials Registry ANZCTR 12619001743156.


Asunto(s)
Colonoscopía , Neoplasias Colorrectales , Humanos , Australia , Estudios Prospectivos , Heces , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
10.
Cancer ; 128(10): 1921-1928, 2022 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-35290664

RESUMEN

BACKGROUND: A blood assay measuring methylated BCAT1 and IKZF1 can detect recurrent colorectal cancer (CRC) with high sensitivity but suboptimal specificity. This study aimed to establish an upper reference limit (URL) of these biomarkers in a reference population without CRC, apply that threshold to detecting clinical recurrence in patients who had undergone definitive therapy for CRC, and compare the performance of the biomarkers with carcinoembryonic antigen (CEA). METHODS: The level of methylation was reported as the aggregate methylated BCAT1 and IKZF1 expressed as a percentage of total plasma DNA. A reference population of patients confirmed to have no colorectal neoplasia (n = 857) was used to determine the URL. Test accuracy for clinical recurrence was determined in a post-treatment surveillance population (n = 549; 77 recurrence cases). RESULTS: A methylation level of 0.07%, corresponding to the 98th percentile in the reference population, was set as the URL. In the surveillance population, 60 patients had methylation levels above 0.07%, and 81.7% of these had recurrence. In comparison with no minimum threshold being applied, assay sensitivity with a URL of 0.07% yielded similar sensitivity (63.6% [CI, 51.9%-74.3%] vs 64.9% [CI, 53.8%-74.7%]; P = .87) and higher specificity (97.7% [CI, 95.9%-98.8%] vs 91.3% [CI, 88.4%-93.5%]; P < .001). The BCAT1/IKZF1 test was 2.5-fold more sensitive than CEA for detecting recurrences considered amenable to surgery with curative intent (50.0% vs 20.8%; P = .016). CONCLUSIONS: Applying a threshold for positivity to the methylated BCAT1/IKZF1 blood assay improved the specificity for CRC recurrence without compromising sensitivity. Both the sensitivity and the specificity were superior to those of CEA.


Asunto(s)
ADN Tumoral Circulante , Neoplasias Colorrectales , Biomarcadores de Tumor/genética , Antígeno Carcinoembrionario , ADN Tumoral Circulante/genética , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/genética , Neoplasias Colorrectales/patología , Metilación de ADN , Humanos , Factor de Transcripción Ikaros/genética , Recurrencia , Transaminasas
11.
J Gastroenterol Hepatol ; 37(6): 1067-1075, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35261071

RESUMEN

BACKGROUND AND AIM: Surveillance colonoscopies may be delayed because of pressure on resources, such as the COVID-19 pandemic. This study aimed to determine whether delayed surveillance colonoscopy increases the risk for advanced neoplasia and whether interval screening with faecal immunochemical tests (FITs) and other known risk factors can mitigate this risk. METHODS: A retrospective cohort study of individuals undergoing surveillance colonoscopy for personal or family history of colorectal neoplasia was being provided with FIT between colonoscopies. Colonoscopy ≥ 6 months after the guideline-recommended interval was considered "delayed." Individuals were stratified based on prime colonoscopy findings to nonneoplastic findings, non-advanced adenoma, and advanced adenoma. The relative risk (RR) for developing advanced neoplasia was determined using a robust multivariable modified Poisson regression. RESULTS: Of 2548 surveillance colonoscopies, 1457 (57.18%) were delayed. Prior advanced adenoma, older age (> 60 years) and nonparticipation in interval FIT were associated with increased risk for advanced neoplasia (P < 0.05). There was a trend to increased risk in those with prior advanced adenoma with an increasing colonoscopy delay (P trend = 0.01). In participants who did not complete interval FIT and having advanced adenoma in the prime colonoscopy, risk of advanced neoplasia was 2.48 times higher (RR = 2.48, 95% confidence interval: 1.20-5.13) in participants who had beyond 2 years of delayed colonoscopy compared with those with on-time colonoscopy. Colonoscopy delay did not increase the risk of advanced neoplasia in participants with negative interval FIT results. CONCLUSION: Surveillance colonoscopy can be safely extended beyond 6 months in elevated colorectal cancer risk patients who do not have prior advanced adenoma diagnosis, particularly if interval FIT is negative.


Asunto(s)
Adenoma , COVID-19 , Neoplasias Colorrectales , Adenoma/diagnóstico , Adenoma/epidemiología , Adenoma/prevención & control , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/epidemiología , Neoplasias Colorrectales/prevención & control , Detección Precoz del Cáncer/métodos , Humanos , Sangre Oculta , Pandemias , Estudios Retrospectivos , Factores de Riesgo
12.
Int J Gynecol Cancer ; 32(5): 646-655, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-35437274

RESUMEN

OBJECTIVE: Lynch syndrome is a hereditary cancer syndrome caused by mismatch repair gene mutations, and female carriers are at an increased risk of endometrial and ovarian cancer. The best approach to screening is not yet clear and practice varies across countries and centers. We aimed to provide evidence to inform the best approach to screening and risk reduction. METHODS: A systematic search of the literature was conducted (Medline, Embase, PubMed). Studies evaluating the following were included: women with Lynch syndrome (by mismatch repair mutation or Amsterdam II criteria), screening methods for endometrial and/or ovarian cancer, intervention included endometrial biopsy, transvaginal ultrasound, or serum cancer antigen 125 (CA-125), outcomes evaluated were number of cancers and/or endometrial hyperplasia. RESULTS: A total of 18 studies of Lynch syndrome carriers which screened for endometrial cancer using transvaginal ultrasound and/or hysteroscopy/endometrial biopsy revealed an incidence of 3.9% at the time of screening. Most (64.1%) endometrial cancers detected were from screening, with the balance detected in symptomatic women at the first screening visits, regular review, or between screening intervals. In mismatch repair carriers, the overall sensitivity of endometrial screening was 66.7%, and the number needed to screen ranged between 4 and 38 (median 7). The sensitivity of endometrial biopsy was 57.1% and the number needed to screen was 23-380 (median 78). The sensitivity of transvaginal ultrasound was 34.4% and the number needed to screen was 35-973 (median 170). Fourteen studies which screened for ovarian cancer using transvaginal ultrasound and/or CA-125 revealed an incidence of 1.3% at the time of screening and 42.9% of ovarian cancers were detected at asymptomatic screening. The sensitivity of ovarian screening was 54.6%, and the number needed to screen was 9-191 (median 23) in mismatch repair carriers. Thirteen studies reported 5.8% incident endometrial cancers and 0.5% ovarian cancers at time of risk reducing surgery. CONCLUSIONS: There is limited evidence to support screening for endometrial and ovarian cancer in Lynch syndrome and data on mortality reduction are not available. Further prospective, randomized trials comparing targeted screening methods are needed. Risk reducing surgery remains the most reliable way to reduce endometrial and ovarian cancer risk in Lynch syndrome.


Asunto(s)
Neoplasias Colorrectales Hereditarias sin Poliposis , Neoplasias Endometriales , Neoplasias Ováricas , Carcinoma Epitelial de Ovario , Neoplasias Colorrectales Hereditarias sin Poliposis/diagnóstico , Neoplasias Colorrectales Hereditarias sin Poliposis/genética , Neoplasias Colorrectales Hereditarias sin Poliposis/cirugía , Reparación de la Incompatibilidad de ADN , Detección Precoz del Cáncer/métodos , Neoplasias Endometriales/diagnóstico , Neoplasias Endometriales/genética , Neoplasias Endometriales/cirugía , Femenino , Humanos , Neoplasias Ováricas/diagnóstico , Neoplasias Ováricas/genética , Neoplasias Ováricas/cirugía
13.
Eur J Cancer Care (Engl) ; 31(6): e13713, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36151912

RESUMEN

OBJECTIVE: This is to determine whether health beliefs regarding colorectal cancer (CRC) screening could predict discomfort with a change to CRC surveillance proposing regular faecal immunochemical tests (FIT) instead of colonoscopy. METHODS: Eight hundred individuals enrolled in a South Australian colonoscopy surveillance programme were invited to complete a survey on surveillance preferences. Responses were analysed using binary logistic regression predicting discomfort with a hypothetical FIT-based surveillance change. Predictor variables included constructs based on the Health Belief Model: perceived threat of CRC, perceived confidence to complete FIT and colonoscopy (self-efficacy), perceived benefits from current surveillance and perceived barriers to FIT and colonoscopy. RESULTS: A total of 408 participants (51%) returned the survey (complete data n = 303; mean age 62 years, 52% male). Most participants (72%) were uncomfortable with FIT-based surveillance reducing colonoscopy frequency. This attitude was predicted by a higher perceived threat of CRC (OR = 1.03 [95% CI 1.01-1.04]), higher colonoscopy self-efficacy (OR = 1.34 [95% CI 1.13-1.59]) and lower perceived barriers to colonoscopy (OR = 0.92 [95% CI 0.86-0.99]). CONCLUSIONS: Health beliefs regarding colonoscopy and perceived threat of CRC may be important to consider when changing CRC surveillance protocols. If guideline changes were introduced, these factors should be addressed to provide patients reassurance concerning the efficacy of the alternative protocol.


Asunto(s)
Neoplasias Colorrectales , Sangre Oculta , Humanos , Masculino , Persona de Mediana Edad , Femenino , Australia , Colonoscopía , Detección Precoz del Cáncer/métodos , Neoplasias Colorrectales/diagnóstico , Modelo de Creencias sobre la Salud , Actitud , Tamizaje Masivo/métodos
14.
Med J Aust ; 215(10): 465-470, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-34386988

RESUMEN

OBJECTIVES: To investigate the incidence of advanced neoplasia (colorectal cancer or advanced adenoma) at surveillance colonoscopy following removal of non-advanced adenoma; to determine whether the time interval before surveillance colonoscopy influences the likelihood of advanced neoplasia. DESIGN: Retrospective cohort study. SETTING, PARTICIPANTS: Patients enrolled in a South Australian surveillance colonoscopy program with findings of non-advanced adenoma during 1999-2016 who subsequently underwent surveillance colonoscopy. MAIN OUTCOME MEASURES: Incidence of advanced neoplasia at follow-up surveillance colonoscopy. RESULTS: Advanced neoplasia was detected in 169 of 965 eligible surveillance colonoscopies (18%) for 904 unique patients (median age, 62.0 years; interquartile range [IQR], 54.0-69.0 years), of whom 570 were men (59.1%). The median interval between the initial and surveillance procedures was 5.2 years (IQR, 4.4-6.0 years; range, 2.0-14 years). Factors associated with increased risk of advanced neoplasia at follow-up included age (per year: odds ratio [OR], 1.03; 95% CI, 1.01-1.05), prior history of adenoma (OR, 1.48; 95% CI, 1.01-2.15), two non-advanced adenomas identified at baseline procedure (v one: OR, 1.74; 95% CI, 1.18-2.57), and time to surveillance colonoscopy (OR, 1.21; 95% CI, 1.08-1.37). The estimated incidence of advanced neoplasia was 19% five years after non-advanced adenoma removal, and 30% at ten years. CONCLUSIONS: Increasing the surveillance colonoscopy interval beyond five years after removal of non-advanced adenoma increases the risk of detection of advanced neoplasia at follow-up colonoscopy.


Asunto(s)
Adenoma/diagnóstico , Adenoma/cirugía , Colonoscopía , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/cirugía , Anciano , Australia , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
15.
J Gastroenterol Hepatol ; 36(6): 1620-1626, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33140867

RESUMEN

BACKGROUND AND AIM: Clinically significant serrated polyps are precursors of colorectal cancers, with features considered high risk including size ≥10 mm, dysplasia, and presence of synchronous conventional adenoma. While these features have been described in cohorts undergoing screening colonoscopy, there is little information regarding the prevalence and patient characteristics associated with high-risk sessile serrated polyps (SSPs) in those undergoing surveillance colonoscopy. METHODS: Polyp pathology at the index and first follow-up colonoscopy performed between 2004 and 2019 were examined in patients enrolled in a surveillance program because of an index finding of adenoma and/or SSP. Demographics and pathology features for SSP were compared between the colonoscopies. RESULTS: Of 6297 patients undergoing index colonoscopy, 2035 underwent follow-up colonoscopy after 3.3 years (interquartile range 2.1-4.8 years). The proportion with SSP decreased from 7.6% at index to 5.0% at follow-up (P < 0.001); however, the proportion of SSPs that were considered high risk was not different between the colonoscopies (62.8% vs 62.4%). Female gender was associated with the presence of high-risk SSP at index colonoscopy (odds ratio [OR] 1.62, 95% confidence interval [CI] 1.28-2.06), while age ≥75 years (OR 3.38, 95% CI 1.67-6.81) and previous high-risk SSP (OR 9.40, 95% CI 4.23-20.88) were independently associated with high-risk SSP at follow-up. CONCLUSIONS: The prevalence of SSP falls by one-third at first follow-up colonoscopy although the proportion of SSP with high-risk features remains the same. While females were more likely to have a high-risk SSP at the index colonoscopy, those at greatest risk for high-risk SSP at follow-up colonoscopy were age >75 years and an index high-risk SSP.


Asunto(s)
Pólipos del Colon/patología , Colonoscopía , Neoplasias Colorrectales/patología , Adenoma/diagnóstico , Adenoma/patología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Pólipos del Colon/diagnóstico , Pólipos del Colon/epidemiología , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/prevención & control , Detección Precoz del Cáncer , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Riesgo , Factores Sexuales , Factores de Tiempo , Adulto Joven
16.
Cancer ; 126(7): 1460-1469, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31909823

RESUMEN

BACKGROUND: The sensitive detection of recurrent colorectal cancer (CRC) by the measurement of circulating tumor DNA (ctDNA) might improve the chance of a cure. This study compared a quantitative methylated ctDNA test with carcinoembryonic antigen (CEA) in the setting of surveillance for recurrence. METHODS: Blood samples collected either during surveillance or within 12 months of the confirmation of recurrence were assayed for ctDNA (methylated branched-chain amino acid transaminase 1 [BCAT1]/Ikaros family zinc-finger 1 protein [IKZF1]) and CEA. The optimal ctDNA threshold was determined by receiver operating characteristic analysis, and the test performance for the detection of recurrence was compared with CEA (5 ng/mL threshold). RESULTS: The study cohort comprised 144 eligible patients and included 50 recurrence events. The sensitivity of the methylated ctDNA test for recurrence was 66.0% (95% confidence interval [CI], 57.1%-69.3%), which was significantly higher than the sensitivity of CEA (31.9%; 95% CI, 22.8%-36.6%; P < .001). The sensitivity for resectable recurrence (n = 20) was also higher (ctDNA, 60.0%; CEA, 20.0%; P = .01). The specificity did not differ between the tests (ctDNA, 97.9%; 95% CI, 93.2%-99.6%; CEA, 96.4%; 95% CI, 91.4%-99.0%). When adjustments were made for other predictors of the presence of recurrence, a positive ctDNA test was an independent predictor (odds ratio, 155.7; 95% CI, 17.9-1360.6; P < .001), whereas CEA was not (odds ratio, 2.5; 95% CI, 0.3-20.6; P = .407). CONCLUSIONS: The quantitative ctDNA test showed superior sensitivity in comparison with CEA without a difference in the specificity for detecting recurrent CRC. Longitudinal studies are warranted to further assess the utility (specifically the survival benefit) of methylated BCAT1/IKZF1 ctDNA in the surveillance of patients with CRC.


Asunto(s)
Biomarcadores de Tumor/sangre , ADN Tumoral Circulante/análisis , Neoplasias Colorrectales/sangre , Neoplasias Colorrectales/diagnóstico , Recurrencia Local de Neoplasia/sangre , Recurrencia Local de Neoplasia/diagnóstico , Anciano , Anciano de 80 o más Años , Biomarcadores de Tumor/genética , Antígeno Carcinoembrionario/sangre , Epigénesis Genética , Femenino , Humanos , Factor de Transcripción Ikaros/sangre , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Transaminasas/sangre
17.
Gastroenterology ; 155(3): 909-925.e3, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29958856

RESUMEN

BACKGROUND & AIMS: Colonoscopy examination does not always detect colorectal cancer (CRC)- some patients develop CRC after negative findings from an examination. When this occurs before the next recommended examination, it is called interval cancer. From a colonoscopy quality assurance perspective, that term is too restrictive, so the term post-colonoscopy colorectal cancer (PCCRC) was created in 2010. However, PCCRC definitions and methods for calculating rates vary among studies, making it impossible to compare results. We aimed to standardize the terminology, identification, analysis, and reporting of PCCRCs and CRCs detected after other whole-colon imaging evaluations (post-imaging colorectal cancers [PICRCs]). METHODS: A 20-member international team of gastroenterologists, pathologists, and epidemiologists; a radiologist; and a non-medical professional met to formulate a series of recommendations, standardize definitions and categories (to align with interval cancer terminology), develop an algorithm to determine most-plausible etiologies, and develop standardized methodology to calculate rates of PCCRC and PICRC. The team followed the Appraisal of Guidelines for Research and Evaluation II tool. A literature review provided 401 articles to support proposed statements; evidence was rated using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) system. The statements were voted on anonymously by team members, using a modified Delphi approach. RESULTS: The team produced 21 statements that provide comprehensive guidance on PCCRCs and PICRCs. The statements present standardized definitions and terms, as well as methods for qualitative review, determination of etiology, calculation of PCCRC rates, and non-colonoscopic imaging of the colon. CONCLUSIONS: A 20-member international team has provided standardized methods for analysis of etiologies of PCCRCs and PICRCs and defines its use as a quality indicator. The team provides recommendations for clinicians, organizations, researchers, policy makers, and patients.


Asunto(s)
Colonoscopía/normas , Neoplasias Colorrectales/diagnóstico , Detección Precoz del Cáncer/normas , Guías de Práctica Clínica como Asunto/normas , Colon/diagnóstico por imagen , Colonoscopía/métodos , Consenso , Detección Precoz del Cáncer/métodos , Humanos , Factores de Riesgo , Factores de Tiempo
18.
Dig Dis Sci ; 64(9): 2555-2562, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30835026

RESUMEN

BACKGROUND: Early detection and removal of precursor lesions reduce colorectal cancer morbidity and mortality. Sessile serrated adenomas/polyps (SSP) are a recognized precursor of cancer, but there are limited studies on whether current screening techniques detect this pathology. AIMS: To investigate the sensitivity of fecal immunochemical tests (FIT) and epigenetic biomarkers in blood for detection of SSP. METHODS: A prospective study offered FIT and a blood test (Colvera for methylated BCAT1 and IKZF1) to adults referred for colonoscopy. Sensitivity of FIT and the blood test were determined for four types of pathology: low-risk conventional adenoma, high-risk adenoma, SSP, and absence of neoplasia. Comparisons were made for FIT positivity at 10 and 20 µg hemoglobin (Hb)/g feces. RESULTS: One thousand eight hundred and eighty-two subjects completed FIT and underwent colonoscopy. One thousand four hundred and three were also tested for methylated BCAT1/IKZF1. The sensitivity of FIT (20 µg Hb/g feces) for SSP was 16.3%. This was lower than the sensitivity for high-risk adenomas (28.7%, p < 0.05), but no different to that for low-risk adenomas (13.1%) or no neoplasia (8.4%). A positive FIT result for SSP was not associated with demographics, morphology, concurrent pathology or intake of medications that increase bleeding risk. FIT sensitivity for SSP did not significantly increase through lowering the positivity threshold to 10 µg Hb/g feces (20.4%, p > 0.05). Sensitivity of the blood test for SSP was 8.8%, and 26.5% when combined with FIT. CONCLUSIONS: Both FIT and blood-based markers of DNA hypermethylation have low sensitivity for detection of SSP. Further development of sensitive screening tests is warranted.


Asunto(s)
Adenoma/diagnóstico , Neoplasias del Colon/diagnóstico , Pólipos del Colon/diagnóstico , Metilación de ADN , Detección Precoz del Cáncer/métodos , Sangre Oculta , Adenoma/sangre , Adenoma/patología , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores de Tumor/sangre , Neoplasias del Colon/sangre , Neoplasias del Colon/patología , Pólipos del Colon/sangre , Pólipos del Colon/patología , Femenino , Hemoglobinas/análisis , Humanos , Factor de Transcripción Ikaros/sangre , Factor de Transcripción Ikaros/genética , Inmunoquímica , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Transaminasas/sangre , Transaminasas/genética
19.
Artículo en Inglés | MEDLINE | ID: mdl-37979664
20.
Int J Mol Sci ; 19(9)2018 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-30200383

RESUMEN

Green cincau (Premna oblongifolia Merr.) is a traditional food of Indonesia and provides a natural source of dietary fibre and antioxidants. This study evaluated the ability of green cincau, and other dietary fibres with or without the addition of anti-oxidant, epigallocatechin-3-gallate (EGCG), to prevent colorectal cancer in a 12 week azoxymethane (AOM) rat model. While all dietary treatments stimulated short chain fatty acid production (SCFA) in the digesta and faeces, no one treatment was able to significantly protect against aberrant crypt formation (ACF), when compared to the control diet. However, feeding green cincau leaves or extracts did not result in an increase in ACF compared to the control diet. Unexpectedly, when the dietary fibre source was pectin, 0.1% EGCG increased proliferative activity and liver lipid peroxidation when compared to the control diet containing cellulose. Examination of faecal microbial communities identified the presence of short chain acid producing bacteria, but a distinct community profile was not observed from any individual diet group. Overall, this research implies that combining dietary fibre with an antioxidant does not automatically equate to a beneficial response. Further work is required to investigate the health-promoting properties of green cincau.


Asunto(s)
Neoplasias del Colon/prevención & control , Fibras de la Dieta/uso terapéutico , Ácidos Grasos Volátiles/metabolismo , Lamiaceae/química , Animales , Azoximetano/toxicidad , Células Cultivadas , Colon/efectos de los fármacos , Colon/metabolismo , Colon/microbiología , Neoplasias del Colon/etiología , Fibras de la Dieta/farmacología , Microbioma Gastrointestinal , Peroxidación de Lípido , Masculino , Ratas , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA