Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am J Emerg Med ; 76: 63-69, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37995525

RESUMEN

INTRODUCTION: Ludwig's angina (LA) is a life-threatening infection that can affect the floor of the mouth and neck, potentially causing serious airway obstruction. In such cases, rescue airway management and oxygenation can be challenging due to swelling of the mouth floor, trismus, and limited mouth opening. The aim of this study was to assess the efficacy of the Trachway video-stylet (VS) and Pentax AWS hyperangulated videolaryngoscope with channel (HAVL-C) compared to the standard geometric video-laryngoscope (SGVL, Macintosh 3, Trachway) in simulating Ludwig's angina with cadavers. METHODS: Three fresh frozen cadavers were prepared with varying degrees of difficulty to simulate the airway conditions of patients with LA, including mouth floor swelling, restricted mouth opening, and trismus. Fifty-five second-year resident physicians from various specialties participated in the study and received training in airway management using SGVL, VS, and HAVL-C devices. Participants were randomly assigned to intubate simulated LA with cadavers using the three devices in a random order, and intubation times and success rates were recorded. Participants also rated the difficulty of intubation using a visual analogue scale (VAS) score. The primary outcome assessed the first-pass intubation success or failure, while the secondary outcomes measured the intubation time and subjective difficulty using a visual analogue scale with different laryngoscopes. RESULTS: The success rates for intubation within 90 s were 40% for SGVL, 82% for VS, and 76% for HAVL-C. VS and HAVL-C had significantly higher success rates than SGVL, with hazard ratios of 3.4 and 2.7, and 95% confidence intervals (CI) of 2.0-5.7 and 1.6-4.6, p < 0.001, respectively. The odds ratios of successful intubation for VS and HAVL-C were 8.1 and 6.3, respectively, with a 95% CI of 3.7-17.8 and 2.4-16.7, p < 0.001, compared to SGVL. The VAS score was significantly correlated with intubation success rate and time. CONCLUSIONS: In cases of LA, the use of VS and HAVL-C is preferable over SGVL. These findings suggest that using VS and HAVL-C can improve intubation success rates and reduce intubation time in patients with LA.


Asunto(s)
Laringoscopios , Angina de Ludwig , Humanos , Intubación Intratraqueal , Trismo , Cadáver , Grabación en Video , Laringoscopía
2.
J Virol ; 86(15): 8041-9, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22623765

RESUMEN

Genetic engineering of induced pluripotent stem cells (iPSCs) is important for their clinical applications, and baculovirus (BV) holds promise as a gene delivery vector. To explore the feasibility of using BV for iPSCs transduction, in this study we first examined how iPSCs responded to BV. We determined that BV transduced iPSCs efficiently, without inducing appreciable negative effects on cell proliferation, apoptosis, pluripotency, and differentiation. BV transduction slightly perturbed the transcription of 12 genes involved in the Toll-like receptor (TLR) signaling pathway, but at the protein level BV elicited no well-known cytokines (e.g., interleukin-6 [IL-6], tumor necrosis factor alpha [TNF-α], and beta interferon [IFN-ß]) except for IP-10. Molecular analyses revealed that iPSCs expressed no TLR1, -6, -8, or -9 and expressed merely low levels of TLR2, -3, and -4. In spite of evident expression of such RNA/DNA sensors as RIG-I and AIM2, iPSCs barely expressed MDA5 and DAI (DNA-dependent activator of IFN regulatory factor [IRF]). Importantly, BV transduction of iPSCs stimulated none of the aforementioned sensors or their downstream signaling mediators (IRF3 and NF-κB). These data together confirmed that iPSCs responded poorly to BV due to the impaired sensing and signaling system, thereby justifying the transduction of iPSCs with the baculoviral vector.


Asunto(s)
Apoptosis , Baculoviridae/inmunología , Diferenciación Celular , Proliferación Celular , Vectores Genéticos/inmunología , Células Madre Pluripotentes Inducidas/inmunología , Transducción Genética , Animales , Células Cultivadas , Citocinas/inmunología , Proteína 58 DEAD Box , ARN Helicasas DEAD-box/inmunología , Proteínas de Unión al ADN , Glicoproteínas/inmunología , Células Madre Pluripotentes Inducidas/patología , Factor 3 Regulador del Interferón/inmunología , Helicasa Inducida por Interferón IFIH1 , Ratones , FN-kappa B/inmunología , Proteínas Nucleares/inmunología , Proteínas de Unión al ARN , Receptores Toll-Like/inmunología
3.
Sci Rep ; 13(1): 12552, 2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37532861

RESUMEN

To evaluate aerosol exposure risk and prevention strategies during bystander, pre-hospital, and inpatient cardiopulmonary resuscitation (CPR). This study compared hands-only CPR, CPR with a surgical or N95 mask, and CPR with a non-rebreather mask at 15 L/min. 30:2 compression-ventilation ratio CPR was tested with face-mask ventilation (FMV), FMV with a high efficiency particulate air (HEPA) filter; supraglottic airway (SGA), SGA with a surgical mask, SGA with a HEPA filter, or SGA with both. Continuous CPR was tested with an endotracheal tube (ET), ET with a surgical mask, a HEPA filter, or both. Aerosol concentration at the head, trunk, and feet of the mannequin were measured to evaluate exposure to CPR personnel. Hands-only CPR with a surgical or N95 face mask coverings and ET tube ventilation CPR with filters showed the lowest aerosol exposure among all study groups, including CPR with NRM oxygenation, FMV, and SGA ventilation. NRM had a mask effect and reduced aerosol exposure at the head, trunk, and feet of the mannequin. FMV with filters during 30:2 CPR reduced aerosol exposure at the head and trunk, but increased at the feet of the mannequin. A tightly-sealed SGA when used with a HEPA filter, reduced aerosol exposure by 21.00-63.14% compared with a loose-fitting one. Hands-only CPR with a proper fit surgical or N95 face mask coverings is as safe as ET tube ventilation CPR with filters, compared with CPR with NRM, FMV, and SGA. FMV or tight-sealed SGA ventilation with filters prolonged the duration to achieve estimated infective dose of SARS-CoV-2 2.4-2.5 times longer than hands-on CPR only. However, a loose-fitting SGA is not protective at all to chest compressor or health workers standing at the foot side of the victim, so should be used with caution even when using with HEPA filters.


Asunto(s)
COVID-19 , Reanimación Cardiopulmonar , Humanos , Maniquíes , Pacientes Internos , COVID-19/prevención & control , SARS-CoV-2 , Aerosoles y Gotitas Respiratorias , Intubación Intratraqueal , Hospitales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA