Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 410(1): 211-221, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29071363

RESUMEN

Digital PCR (dPCR), as a new technology in the field of genetically modified (GM) organism (GMO) testing, enables determination of absolute target copy numbers. The purpose of our study was to test the transferability of methods designed for quantitative PCR (qPCR) to dPCR and to carry out an inter-laboratory comparison of the performance of two different dPCR platforms when determining the absolute GM copy numbers and GM copy number ratio in reference materials certified for GM content in mass fraction. Overall results in terms of measured GM% were within acceptable variation limits for both tested dPCR systems. However, the determined absolute copy numbers for individual genes or events showed higher variability between laboratories in one third of the cases, most possibly due to variability in the technical work, droplet size variability, and analysis of the raw data. GMO quantification with dPCR and qPCR was comparable. As methods originally designed for qPCR performed well in dPCR systems, already validated qPCR assays can most generally be used for dPCR technology with the purpose of GMO detection. Graphical abstract The output of three different PCR-based platforms was assessed in an inter-laboratory comparison.


Asunto(s)
ADN de Plantas/genética , Pisum sativum/genética , Plantas Modificadas Genéticamente/genética , Reacción en Cadena de la Polimerasa/métodos , Zea mays/genética , Dosificación de Gen , Dispositivos Laboratorio en un Chip , Reacción en Cadena de la Polimerasa/instrumentación
2.
Anal Bioanal Chem ; 409(28): 6689-6697, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28921124

RESUMEN

Accurate and precise nucleic-acid quantification is crucial for clinical and diagnostic decisions, as overestimation or underestimation can lead to misguided treatment of a disease or incorrect labelling of the products. Digital PCR is one of the best tools for absolute nucleic-acid copy-number determination. However, digital PCR needs to be well characterised in terms of accuracy and sources of uncertainty. With droplet digital PCR, discrepancies between the droplet volume assigned by the manufacturer and measured by independent laboratories have already been shown in previous studies. In the present study, we report on the results of an inter-laboratory comparison of different methods for droplet volume determination that is based on optical microscopy imaging and is traceable to the International System of Units. This comparison was conducted on the same DNA material, with the examination of the influence of parameters such as droplet generators, supermixes, operators, inter-cartridge and intra-cartridge variability, and droplet measuring protocol. The mean droplet volume was measured using a QX200™ AutoDG™ Droplet Digital™ PCR system and two QX100™ Droplet Digital™ PCR systems. The data show significant volume differences between these two systems, as well as significant differences in volume when different supermixes are used. We also show that both of these droplet generator systems produce droplets with significantly lower droplet volumes (13.1%, 15.9%, respectively) than stated by the manufacturer and previously measured by other laboratories. This indicates that to ensure precise quantification, the droplet volumes should be assessed for each system.


Asunto(s)
ADN/análisis , Reacción en Cadena de la Polimerasa/métodos , Análisis de Varianza , ADN/genética , Procesamiento de Imagen Asistido por Computador , Microscopía , Imagen Óptica , Reacción en Cadena de la Polimerasa/instrumentación , Tamaño de la Muestra , Programas Informáticos
3.
Anal Bioanal Chem ; 409(10): 2601-2614, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28124757

RESUMEN

Quantitative PCR (qPCR) is an important tool in pathogen detection. However, the use of different qPCR components, calibration materials and DNA extraction methods reduces comparability between laboratories, which can result in false diagnosis and discrepancies in patient care. The wider establishment of a metrological framework for nucleic acid tests could improve the degree of standardisation of pathogen detection and the quantification methods applied in the clinical context. To achieve this, accurate methods need to be developed and implemented as reference measurement procedures, and to facilitate characterisation of suitable certified reference materials. Digital PCR (dPCR) has already been used for pathogen quantification by analysing nucleic acids. Although dPCR has the potential to provide robust and accurate quantification of nucleic acids, further assessment of its actual performance characteristics is needed before it can be implemented in a metrological framework, and to allow adequate estimation of measurement uncertainties. Here, four laboratories demonstrated reproducibility (expanded measurement uncertainties below 15%) of dPCR for quantification of DNA from human cytomegalovirus, with no calibration to a common reference material. Using whole-virus material and extracted DNA, an intermediate precision (coefficients of variation below 25%) between three consecutive experiments was noted. Furthermore, discrepancies in estimated mean DNA copy number concentrations between laboratories were less than twofold, with DNA extraction as the main source of variability. These data demonstrate that dPCR offers a repeatable and reproducible method for quantification of viral DNA, and due to its satisfactory performance should be considered as candidate for reference methods for implementation in a metrological framework.


Asunto(s)
Infecciones por Citomegalovirus/diagnóstico , Citomegalovirus/genética , ADN Viral/análisis , Ensayos de Aptitud de Laboratorios/normas , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Citomegalovirus/aislamiento & purificación , Infecciones por Citomegalovirus/genética , Infecciones por Citomegalovirus/virología , ADN Viral/genética , Humanos , Reproducibilidad de los Resultados
4.
J Clin Microbiol ; 54(2): 392-400, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26659206

RESUMEN

Digital PCR (dPCR) is being increasingly used for the quantification of sequence variations, including single nucleotide polymorphisms (SNPs), due to its high accuracy and precision in comparison with techniques such as quantitative PCR (qPCR) and melt curve analysis. To develop and evaluate dPCR for SNP detection using DNA, RNA, and clinical samples, an influenza virus model of resistance to oseltamivir (Tamiflu) was used. First, this study was able to recognize and reduce off-target amplification in dPCR quantification, thereby enabling technical sensitivities down to 0.1% SNP abundance at a range of template concentrations, a 50-fold improvement on the qPCR assay used routinely in the clinic. Second, a method was developed for determining the false-positive rate (background) signal. Finally, comparison of dPCR with qPCR results on clinical samples demonstrated the potential impact dPCR could have on clinical research and patient management by earlier (trace) detection of rare drug-resistant sequence variants. Ultimately this could reduce the quantity of ineffective drugs taken and facilitate early switching to alternative medication when available. In the short term such methods could advance our understanding of microbial dynamics and therapeutic responses in a range of infectious diseases such as HIV, viral hepatitis, and tuberculosis. Furthermore, the findings presented here are directly relevant to other diagnostic areas, such as the detection of rare SNPs in malignancy, monitoring of graft rejection, and fetal screening.


Asunto(s)
Antivirales/farmacología , Farmacorresistencia Viral , Virus de la Influenza A/efectos de los fármacos , Virus de la Influenza A/genética , Gripe Humana/diagnóstico , Gripe Humana/virología , Mutación , Antivirales/uso terapéutico , Genes Virales , Humanos , Subtipo H1N1 del Virus de la Influenza A/efectos de los fármacos , Subtipo H1N1 del Virus de la Influenza A/genética , Gripe Humana/tratamiento farmacológico , Tipificación Molecular , Oseltamivir/farmacología , Polimorfismo de Nucleótido Simple , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad
5.
BMC Infect Dis ; 16: 366, 2016 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-27487852

RESUMEN

BACKGROUND: Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. METHODS: To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. RESULTS: dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. CONCLUSIONS: TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification of Mycobacterium tuberculosis would provide a clinically useful readout. The methods described in this study provide a means by which the technical performance of quantitative molecular methods can be evaluated independently of clinical variability to improve accuracy of measurement results. These will assist in ultimately increasing the likelihood that such approaches could be used to improve patient management of TB.


Asunto(s)
ADN Bacteriano/aislamiento & purificación , Mycobacterium tuberculosis/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Tuberculosis Pulmonar/diagnóstico , Adulto , Femenino , Humanos , Masculino , Microscopía , Técnicas de Diagnóstico Molecular , Patología Molecular , Sensibilidad y Especificidad
6.
Anal Bioanal Chem ; 408(1): 107-21, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26521179

RESUMEN

Digital PCR (dPCR) is beginning to supersede real-time PCR (qPCR) for quantification of nucleic acids in many different applications. Several analytical properties of the two most commonly used dPCR platforms, namely the QX100 system (Bio-Rad) and the 12.765 array of the Biomark system (Fluidigm), have already been evaluated and compared with those of qPCR. However, to the best of our knowledge, direct comparison between the three of these platforms using the same DNA material has not been done, and the 37 K array on the Biomark system has also not been evaluated in terms of linearity, analytical sensitivity and limit of quantification. Here, a first assessment of qPCR, the QX100 system and both arrays of the Biomark system was performed with plasmid and genomic DNA from human cytomegalovirus. With use of PCR components that alter the efficiency of qPCR, each dPCR platform demonstrated consistent copy-number estimations, which indicates the high resilience of dPCR. Two approaches, one considering the total reaction volume and the other considering the effective reaction size, were used to assess linearity, analytical sensitivity and variability. When the total reaction volume was considered, the best performance was observed with qPCR, followed by the QX100 system and the Biomark system. In contrast, when the effective reaction size was considered, all three platforms showed almost equal limits of detection and variability. Although dPCR might not always be more appropriate than qPCR for quantification of low copy numbers, dPCR is a suitable method for robust and reproducible quantification of viral DNA, and a promising technology for the higher-order reference measurement method.


Asunto(s)
Citomegalovirus/genética , ADN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Infecciones por Citomegalovirus/virología , Humanos , Plásmidos/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación
7.
Anal Bioanal Chem ; 408(1): 67-75, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26483186

RESUMEN

DNA extraction before amplification is considered an essential step for quantification of viral DNA using real-time PCR (qPCR). However, this can directly affect the final measurements due to variable DNA yields and removal of inhibitors, which leads to increased inter-laboratory variability of qPCR measurements and reduced agreement on viral loads. Digital PCR (dPCR) might be an advantageous methodology for the measurement of virus concentrations, as it does not depend on any calibration material and it has higher tolerance to inhibitors. DNA quantification without an extraction step (i.e. direct quantification) was performed here using dPCR and two different human cytomegalovirus whole-virus materials. Two dPCR platforms were used for this direct quantification of the viral DNA, and these were compared with quantification of the extracted viral DNA in terms of yield and variability. Direct quantification of both whole-virus materials present in simple matrices like cell lysate or Tris-HCl buffer provided repeatable measurements of virus concentrations that were probably in closer agreement with the actual viral load than when estimated through quantification of the extracted DNA. Direct dPCR quantification of other viruses, reference materials and clinically relevant matrices is now needed to show the full versatility of this very promising and cost-efficient development in virus quantification.


Asunto(s)
Infecciones por Citomegalovirus/virología , Citomegalovirus/genética , ADN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Citomegalovirus/química , Citomegalovirus/aislamiento & purificación , ADN Viral/aislamiento & purificación , Humanos
8.
Anal Bioanal Chem ; 408(17): 4595-614, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27100228

RESUMEN

The emergence of high-throughput, massive or next-generation sequencing technologies has created a completely new foundation for molecular analyses. Various selective enrichment processes are commonly applied to facilitate detection of predefined (known) targets. Such approaches, however, inevitably introduce a bias and are prone to miss unknown targets. Here we review the application of high-throughput sequencing technologies and the preparation of fit-for-purpose whole genome shotgun sequencing libraries for the detection and characterization of genetically modified and derived products. The potential impact of these new sequencing technologies for the characterization, breeding selection, risk assessment, and traceability of genetically modified organisms and genetically modified products is yet to be fully acknowledged. The published literature is reviewed, and the prospects for future developments and use of the new sequencing technologies for these purposes are discussed.


Asunto(s)
Genoma , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Organismos Modificados Genéticamente , Transcriptoma , Transgenes
9.
Anal Bioanal Chem ; 408(17): 4575-93, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27086015

RESUMEN

With the increased global production of different genetically modified (GM) plant varieties, chances increase that unauthorized GM organisms (UGMOs) may enter the food chain. At the same time, the detection of UGMOs is a challenging task because of the limited sequence information that will generally be available. PCR-based methods are available to detect and quantify known UGMOs in specific cases. If this approach is not feasible, DNA enrichment of the unknown adjacent sequences of known GMO elements is one way to detect the presence of UGMOs in a food or feed product. These enrichment approaches are also known as chromosome walking or gene walking (GW). In recent years, enrichment approaches have been coupled with next generation sequencing (NGS) analysis and implemented in, amongst others, the medical and microbiological fields. The present review will provide an overview of these approaches and an evaluation of their applicability in the identification of UGMOs in complex food or feed samples.


Asunto(s)
ADN/genética , Organismos Modificados Genéticamente/genética , Paseo de Cromosoma , Alimentos Modificados Genéticamente , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Hibridación de Ácido Nucleico , Reacción en Cadena de la Polimerasa
10.
Anal Chem ; 87(16): 8218-26, 2015 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-26169291

RESUMEN

Presence of genetically modified organisms (GMO) in food and feed products is regulated in many countries. The European Union (EU) has implemented a threshold for labeling of products containing more than 0.9% of authorized GMOs per ingredient. As the number of GMOs has increased over time, standard-curve based simplex quantitative polymerase chain reaction (qPCR) analyses are no longer sufficiently cost-effective, despite widespread use of initial PCR based screenings. Newly developed GMO detection methods, also multiplex methods, are mostly focused on screening and detection but not quantification. On the basis of droplet digital PCR (ddPCR) technology, multiplex assays for quantification of all 12 EU authorized GM maize lines (per April first 2015) were developed. Because of high sequence similarity of some of the 12 GM targets, two separate multiplex assays were needed. In both assays (4-plex and 10-plex), the transgenes were labeled with one fluorescence reporter and the endogene with another (GMO concentration = transgene/endogene ratio). It was shown that both multiplex assays produce specific results and that performance parameters such as limit of quantification, repeatability, and trueness comply with international recommendations for GMO quantification methods. Moreover, for samples containing GMOs, the throughput and cost-effectiveness is significantly improved compared to qPCR. Thus, it was concluded that the multiplex ddPCR assays could be applied for routine quantification of 12 EU authorized GM maize lines. In case of new authorizations, the events can easily be added to the existing multiplex assays. The presented principle of quantitative multiplexing can be applied to any other domain.


Asunto(s)
Reacción en Cadena de la Polimerasa Multiplex/métodos , Plantas Modificadas Genéticamente/genética , Zea mays/genética , Unión Europea , Reacción en Cadena de la Polimerasa Multiplex/economía , Reproducibilidad de los Resultados
11.
J Clin Microbiol ; 53(7): 2008-14, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25392365

RESUMEN

Nucleic acid-based tests for infectious diseases currently used in the clinical laboratory and in point-of-care devices are diverse. Measurement challenges associated with standardization of quantitative viral load testing are discussed in relation to human cytomegalovirus, BK virus, and Epstein-Barr virus, while the importance of defining the performance of qualitative methods is illustrated with Mycobacterium tuberculosis and influenza virus. The development of certified reference materials whose values are traceable to higher-order standards and reference measurement procedures, using, for instance, digital PCR, will further contribute to the understanding of analytical performance characteristics and promote clinical data comparability.


Asunto(s)
Bacterias/aislamiento & purificación , Carga Bacteriana/normas , Técnicas de Diagnóstico Molecular/normas , Carga Viral/normas , Virus/aislamiento & purificación , Infecciones Bacterianas/microbiología , Carga Bacteriana/métodos , Humanos , Técnicas de Diagnóstico Molecular/métodos , Estándares de Referencia , Carga Viral/métodos , Virosis/virología
12.
Pestic Biochem Physiol ; 122: 59-66, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26071808

RESUMEN

Colorado potato beetle (Leptinotarsa decemlineata Say, CPB) is a major potato pest that adapts readily to insecticides. Several types of protease inhibitors have previously been investigated as potential control agents, but with limited success. Recently, cysteine protease inhibitors from parasol mushroom, the macrocypins, were reported to inhibit growth of CPB larvae. To further investigate the insecticidal potential and mode of action of cysteine protease inhibitors of fungal origin, clitocypin, a cysteine protease inhibitor from clouded agaric (Clitocybe nebularis), was evaluated for its lethal effects on CPB larvae. Clitocypin isolated from fruiting bodies and recombinant clitocypin produced in Escherichia coli slowed growth and reduced survival of CPB larvae in a concentration dependent manner. Clitocypin was also expressed by transgenic potato, but only at low levels. Nevertheless, it reduced larval weight gain and delayed development. We have additionally shown that younger larvae are more susceptible to the action of clitocypin. The inhibition of digestive cysteine proteases, intestains, by clitocypin was shown to be the underlying mode of action. Protease inhibitors from mushrooms are confirmed as promising candidates for biopesticides.


Asunto(s)
Escarabajos/efectos de los fármacos , Inhibidores de Cisteína Proteinasa/farmacología , Proteínas Fúngicas/farmacología , Insecticidas/farmacología , Solanum tuberosum/genética , Animales , Escarabajos/enzimología , Escarabajos/genética , Sistema Digestivo/efectos de los fármacos , Sistema Digestivo/enzimología , Relación Dosis-Respuesta a Droga , Femenino , Proteínas Fúngicas/genética , Regulación de la Expresión Génica/efectos de los fármacos , Larva/efectos de los fármacos , Larva/fisiología , Plantas Modificadas Genéticamente , Proteínas Recombinantes/farmacología
13.
BMC Bioinformatics ; 15: 258, 2014 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-25084968

RESUMEN

BACKGROUND: With the increasing pace of new Genetically Modified Organisms (GMOs) authorized or in pipeline for commercialization worldwide, the task of the laboratories in charge to test the compliance of food, feed or seed samples with their relevant regulations became difficult and costly. Many of them have already adopted the so called "matrix approach" to rationalize the resources and efforts used to increase their efficiency within a limited budget. Most of the time, the "matrix approach" is implemented using limited information and some proprietary (if any) computational tool to efficiently use the available data. RESULTS: The developed GMOseek software is designed to support decision making in all the phases of routine GMO laboratory testing, including the interpretation of wet-lab results. The tool makes use of a tabulated matrix of GM events and their genetic elements, of the laboratory analysis history and the available information about the sample at hand. The tool uses an optimization approach to suggest the most suited screening assays for the given sample. The practical GMOseek user interface allows the user to customize the search for a cost-efficient combination of screening assays to be employed on a given sample. It further guides the user to select appropriate analyses to determine the presence of individual GM events in the analyzed sample, and it helps taking a final decision regarding the GMO composition in the sample. GMOseek can also be used to evaluate new, previously unused GMO screening targets and to estimate the profitability of developing new GMO screening methods. CONCLUSION: The presented freely available software tool offers the GMO testing laboratories the possibility to select combinations of assays (e.g. quantitative real-time PCR tests) needed for their task, by allowing the expert to express his/her preferences in terms of multiplexing and cost. The utility of GMOseek is exemplified by analyzing selected food, feed and seed samples from a national reference laboratory for GMO testing and by comparing its performance to existing tools which use the matrix approach. GMOseek proves superior when tested on real samples in terms of GMO coverage and cost efficiency of its screening strategies, including its capacity of simple interpretation of the testing results.


Asunto(s)
Biología Computacional/métodos , Plantas Modificadas Genéticamente , Programas Informáticos , Toma de Decisiones , Laboratorios , Reacción en Cadena en Tiempo Real de la Polimerasa , Interfaz Usuario-Computador
14.
Anal Bioanal Chem ; 406(26): 6485-97, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25182968

RESUMEN

Cultivation and marketing of genetically modified organisms (GMOs) have been unevenly adopted worldwide. To facilitate international trade and to provide information to consumers, labelling requirements have been set up in many countries. Quantitative real-time polymerase chain reaction (qPCR) is currently the method of choice for detection, identification and quantification of GMOs. This has been critically assessed and the requirements for the method performance have been set. Nevertheless, there are challenges that should still be highlighted, such as measuring the quantity and quality of DNA, and determining the qPCR efficiency, possible sequence mismatches, characteristics of taxon-specific genes and appropriate units of measurement, as these remain potential sources of measurement uncertainty. To overcome these problems and to cope with the continuous increase in the number and variety of GMOs, new approaches are needed. Statistical strategies of quantification have already been proposed and expanded with the development of digital PCR. The first attempts have been made to use new generation sequencing also for quantitative purposes, although accurate quantification of the contents of GMOs using this technology is still a challenge for the future, and especially for mixed samples. New approaches are needed also for the quantification of stacks, and for potential quantification of organisms produced by new plant breeding techniques.


Asunto(s)
ADN/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Organismos Modificados Genéticamente/genética , Reacción en Cadena de la Polimerasa/métodos , Animales , ADN/análisis , Electroforesis Capilar/métodos , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos
15.
Anal Bioanal Chem ; 406(26): 6513-28, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25173868

RESUMEN

Here we report on the first assessment of droplet digital PCR (ddPCR) for detection and absolute quantification of two quarantine plant pathogenic bacteria that infect many species of the Rosaceae and Solanaceae families: Erwinia amylovora and Ralstonia solanacearum. An open-source R script was written for the ddPCR data analysis. Analysis of a set of samples with known health status aided the assessment and selection of different threshold settings (QuantaSoft analysis, definetherain pipeline and manual threshold), which led to optimal diagnostic specificity. The interpretation of the E. amylovora ddPCR was straightforward, and the analysis approach had little influence on the final results and the concentrations determined. The sensitivity and linear range were similar to those for real-time PCR (qPCR), for the analysis of both bacterial suspensions and plant material, making ddPCR a viable choice when both detection and quantification are desired. With the R. solanacearum ddPCR, the use of a high global threshold was necessary to exclude false-positive reactions that are sometimes observed in healthy plant material. ddPCR significantly improved the analytical sensitivity over that of qPCR, and improved the detection of low concentrations of R. solanacearum in potato tuber samples. Accurate and rapid absolute quantification of both of these bacteria in pure culture was achieved by direct ddPCR. Our data confirm the suitability of these ddPCR assays for routine detection and quantification of plant pathogens and for preparation of defined in-house reference materials with known target concentrations.


Asunto(s)
ADN Bacteriano/aislamiento & purificación , Erwinia amylovora/aislamiento & purificación , Enfermedades de las Plantas/microbiología , Reacción en Cadena de la Polimerasa/métodos , Ralstonia solanacearum/aislamiento & purificación , Rosaceae/microbiología , Solanum tuberosum/microbiología , ADN Bacteriano/genética , Erwinia amylovora/genética , Límite de Detección , Ralstonia solanacearum/genética
16.
BMC Bioinformatics ; 14: 256, 2013 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-23965170

RESUMEN

BACKGROUND: Since their first commercialization, the diversity of taxa and the genetic composition of transgene sequences in genetically modified plants (GMOs) are constantly increasing. To date, the detection of GMOs and derived products is commonly performed by PCR-based methods targeting specific DNA sequences introduced into the host genome. Information available regarding the GMOs' molecular characterization is dispersed and not appropriately organized. For this reason, GMO testing is very challenging and requires more complex screening strategies and decision making schemes, demanding in return the use of efficient bioinformatics tools relying on reliable information. DESCRIPTION: The GMOseek matrix was built as a comprehensive, online open-access tabulated database which provides a reliable, comprehensive and user-friendly overview of 328 GMO events and 247 different genetic elements (status: 18/07/2013). The GMOseek matrix is aiming to facilitate GMO detection from plant origin at different phases of the analysis. It assists in selecting the targets for a screening analysis, interpreting the screening results, checking the occurrence of a screening element in a group of selected GMOs, identifying gaps in the available pool of GMO detection methods, and designing a decision tree. The GMOseek matrix is an independent database with effective functionalities in a format facilitating transferability to other platforms. Data were collected from all available sources and experimentally tested where detection methods and certified reference materials (CRMs) were available. CONCLUSIONS: The GMOseek matrix is currently a unique and very valuable tool with reliable information on GMOs from plant origin and their present genetic elements that enables further development of appropriate strategies for GMO detection. It is flexible enough to be further updated with new information and integrated in different applications and platforms.


Asunto(s)
Técnicas de Apoyo para la Decisión , Secuencia de Bases , Genes de Plantas , Plantas Modificadas Genéticamente/genética , Reacción en Cadena de la Polimerasa/métodos
17.
Foods ; 12(22)2023 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-38002213

RESUMEN

The proliferation of genetically modified organisms (GMOs) presents challenges to GMO testing laboratories and policymakers. Traditional methods, like quantitative real-time PCR (qPCR), face limitations in quantifying the increasing number of GMOs in a single sample. Digital PCR (dPCR), specifically multiplexing, offers a solution by enabling simultaneous quantification of multiple GMO targets. This study explores the use of the Naica six-color Crystal dPCR platform for quantifying five GM soybean lines within a single six-plex assay. Two four-color assays were also developed for added flexibility. These assays demonstrated high specificity, sensitivity (limit of detection or LOD < 25 copies per reaction) and precision (bias to an estimated copy number concentration <15%). Additionally, two approaches for the optimization of data analysis were implemented. By applying a limit-of-blank (LOB) correction, the limit of quantification (LOQ) and LOD could be more precisely determined. Pooling of reactions additionally lowered the LOD, with a two- to eight-fold increase in sensitivity. Real-life samples from routine testing were used to confirm the assays' applicability for quantifying GM soybean lines in complex samples. This study showcases the potential of the six-color Crystal dPCR platform to revolutionize GMO testing, facilitating comprehensive analysis of GMOs in complex samples.

18.
Front Microbiol ; 12: 618209, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33584622

RESUMEN

Water scarcity is one of the greatest threats for human survival and quality of life, and this is increasingly contributing to the risk of human, animal and plant infections due to waterborne viruses. Viruses are transmitted through polluted water, where they can survive and cause infections even at low concentrations. Plant viruses from the genus Tobamovirus are highly mechanically transmissible, and cause considerable damage to important crops, such as tomato. The release of infective tobamoviruses into environmental waters has been reported, with the consequent risk for arid regions, where these waters are used for irrigation. Virus inactivation in water is thus very important and cold atmospheric plasma (CAP) is emerging in this field as an efficient, safe, and sustainable alternative to classic waterborne virus inactivation methods. In the present study we evaluated CAP-mediated inactivation of pepper mild mottle virus (PMMoV) in water samples. PMMoV is a very resilient water-transmissible tobamovirus that can survive transit through the human digestive tract. The efficiency of PMMoV inactivation was characterized for infectivity and virion integrity, and at the genome level, using test plant infectivity assays, transmission electron microscopy, and molecular methods, respectively. Additionally, the safety of CAP treatment was determined by testing the cytotoxic and genotoxic properties of CAP-treated water on the HepG2 cell line. 5-min treatment with CAP was sufficient to inactivate PMMoV without introducing any cytotoxic or genotoxic effects in the in-vitro cell model system. These data on inactivation of such stable waterborne virus, PMMoV, will encourage further examination of CAP as an alternative for treatment of potable and irrigation waters, and even for other water sources, with emphasis on inactivation of various viruses including enteric viruses.

19.
Anal Bioanal Chem ; 396(6): 1991-2002, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19876618

RESUMEN

The steady rate of development and diffusion of genetically modified plants and their increasing diversification of characteristics, genes and genetic control elements poses a challenge in analysis of genetically modified organisms (GMOs). It is expected that in the near future the picture will be even more complex. Traditional approaches, mostly based on the sequential detection of one target at a time, or on a limited multiplexing, allowing only a few targets to be analysed at once, no longer meet the testing requirements. Along with new analytical technologies, new approaches for the detection of GMOs authorized for commercial purposes in various countries have been developed that rely on (1) a smart and accurate strategy for target selection, (2) the use of high-throughput systems or platforms for the detection of multiple targets and (3) algorithms that allow the conversion of analytical results into an indication of the presence of individual GMOs potentially present in an unknown sample. This paper reviews the latest progress made in GMO analysis, taking examples from the most recently developed strategies and tools, and addresses some of the critical aspects related to these approaches.


Asunto(s)
Técnicas Genéticas , Ensayos Analíticos de Alto Rendimiento/métodos , Plantas Modificadas Genéticamente/genética
20.
Anal Bioanal Chem ; 396(6): 2023-9, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20087729

RESUMEN

Several techniques have been developed for detection and quantification of genetically modified organisms, but quantitative real-time PCR is by far the most popular approach. Among the most commonly used real-time PCR chemistries are TaqMan probes and SYBR green, but many other detection chemistries have also been developed. Because their performance has never been compared systematically, here we present an extensive evaluation of some promising chemistries: sequence-unspecific DNA labeling dyes (SYBR green), primer-based technologies (AmpliFluor, Plexor, Lux primers), and techniques involving double-labeled probes, comprising hybridization (molecular beacon) and hydrolysis (TaqMan, CPT, LNA, and MGB) probes, based on recently published experimental data. For each of the detection chemistries assays were included targeting selected loci. Real-time PCR chemistries were subsequently compared for their efficiency in PCR amplification and limits of detection and quantification. The overall applicability of the chemistries was evaluated, adding practicability and cost issues to the performance characteristics. None of the chemistries seemed to be significantly better than any other, but certain features favor LNA and MGB technology as good alternatives to TaqMan in quantification assays. SYBR green and molecular beacon assays can perform equally well but may need more optimization prior to use.


Asunto(s)
ADN de Plantas/genética , Plantas Modificadas Genéticamente/química , Plantas Modificadas Genéticamente/genética , Reacción en Cadena de la Polimerasa/métodos , ADN de Plantas/química , Reacción en Cadena de la Polimerasa/economía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA