Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Idioma
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 44(3): 481-4, 493, 2013 May.
Artículo en Zh | MEDLINE | ID: mdl-23898540

RESUMEN

OBJECTIVE: To detect unknown impurities in raw drug material of cefotiam hexetil. METHODS: High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was employed for the determination of impurities in cefotiam hexetil. Agilent SB-C18 column (150 mm x 2.1 mm i. d. , 3.5 microm particles) was used for chromatographic separations of cofotiam hexetil dissolved in deionized water, with mobile phase consisting of (A) 0.1% formic acid and (B) acetonitrile and timed gradient program T (min)/B (%): 0/3, 5/3, 15/20, 20/40, 30/60, 40/80. The flow rate was set at 0. 3 mL/min with DAD detector wavelength fixed at 254 nm. Electrospray ionization source was applied and operated in positive ion MRM mode. The source voltage was kept at 4 kV and cone voltage was 100 V with the mass range m/z 50-1000. Nitrogen was used as nebulizing gas and the nebulizer pressure was 40 psi. The drying gas temperature was 350 degrees C and the drying gas flow was 10 L/min. Results Unknown impurities of cefotiam hexetil were identified. Substance 1 was delta3-isomer of cefotiam hexetil. The structures of 3 other substances were also determined. CONCLUSION: The method is sensitive, rapid and credible for the analysis of cefotiam hexetil and its related impurities, which can be applied in quality control of cefotiam hexetil.


Asunto(s)
Cefotiam/análogos & derivados , Cromatografía Líquida de Alta Presión , Contaminación de Medicamentos , Espectrometría de Masas en Tándem , Cefotiam/química , Contaminación de Medicamentos/prevención & control , Control de Calidad
2.
Fa Yi Xue Za Zhi ; 28(5): 347-50, 2012 Oct.
Artículo en Zh | MEDLINE | ID: mdl-23213784

RESUMEN

OBJECTIVE: To establish a method for determination of strychnine and brucine in formaldehyde fixed tissue by LC-MS/MS analysis. METHODS: The samples were pretreated with solid phase extraction using SCX cartridges and separated on SB-C18 column with mobile phase 0.1% formic acid : 0.1% formic acid-acetonitrile (75:25). Electrospray ionization (ESI) source was utilized and operated in positive ion mode. Multiple reactions monitoring (MRM) mode was applied. External standard method was applied for quantitation. RESULTS: The chromatographic separation of strychnine and brucine in formaldehyde fixed nephritic and hepatic tissues resulted successfully. The standard curve was linear in the range of 0.002-2.0 microg/g for strychnine and brucine in formaldehyde fixed tissues, and the correlation coefficient was more than 0.996. The limits of detection (LOD) of strychnine and brucine in nephritic tissues were 0.06ng/g and 0.03 ng/g, respectively. The LOD of both chemicals were 0.3 ng/g in hepatic tissues. The extraction recovery rate was more than 74.5%. The precision of intra-day and inter-day were both less than 8.2%. CONCLUSION: Strychnine and brucine can be sensitive to be determined in formaldehyde fixed tissue by LC-MS/MS analysis. It can be applied in the forensic toxicological analysis.


Asunto(s)
Cromatografía Liquida/métodos , Formaldehído/química , Límite de Detección , Espectrometría de Masa por Ionización de Electrospray/métodos , Estricnina/análogos & derivados , Toxicología Forense , Formiatos , Riñón/metabolismo , Hígado/metabolismo , Espectrometría de Masas , Estructura Molecular , Reproducibilidad de los Resultados , Estricnina/análisis , Estricnina/química , Espectrometría de Masas en Tándem , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA