1.
Sensors (Basel) ; 24(11)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38894459

RESUMEN

S-parameters are widely used to detail the scattering parameters of radio frequency (RF) components and microwave circuit modules. The vector network analyzer (VNA) is the most commonly used device for measuring S-parameters. Given the multiple frequency points, complex values, and intricate uncertainty propagation involved, accurately assessing the uncertainty of S-parameter measurements is difficult. In this study, we proposed a new method for assessing S-parameter uncertainty based on the covariance matrices, tracing back to the nominal uncertainty of calibration standards. First, we analyzed the relevant theory of uncertainty assessment using covariance matrices and subsequently deduced the mechanism of Type B uncertainty propagating from calibration standards to error model coefficients and S-parameter measurements to evaluate Type B measurement uncertainty. In this study, a novel measurement system was constructed for measuring grounded coplanar waveguides by using a VNA and calibration standards with 8- and 12-error models. Initially, the model assessed the Type B uncertainty of measuring four S-parameters of a grounded coplanar waveguide. Next, the VNA calibrated with the 12-error model was used to conduct multiple repeated measurements to assess the Type A uncertainty of the grounded coplanar waveguide. Finally, the composite uncertainty was constructed, which demonstrated that the proposed method can be used for assessing the uncertainty of S-parameters.

2.
Sensors (Basel) ; 23(9)2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37177548

RESUMEN

A grounded coplanar waveguide (GCPW), as a millimeter wave special transmission line, can be used to calibrate broadband oscilloscope probes. A method to change the through-hole structure to widen the GCPW is investigated in this paper. The effect of the through-hole array on the band-width of the GCPW is investigated and verified using COMSOL Multiphysics simulation software. Finally, the S-parameters of the fabricated GCPWs are measured by a vector network analyzer, and the results show that they have an insertion loss > -3 dB and return loss < -10 dB in the frequency range of DC to 60 GHz, which satisfies the design requirements.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA