Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Curr Drug Saf ; 18(1): 93-96, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35570532

RESUMEN

BACKGROUND: Lumacaftor/Ivacaftor (LUM/IVA) is an approved combination therapy for cystic fibrosis (CF) patients homozygous for F508del. OBJECTIVE: This study aimed to detect changes in liver stiffness measurement (LSM) in patients under this treatment. METHODS: The study population consisted of CF patients homozygous for F508del, 6 to 11 years old, who had been treated for six months with LUM/IVA. Shear wave elastography (SWE) was performed in all of them, before and 6 months after the commencement of treatment. RESULTS: Thirty-one patients were included in the study. LSM values after treatment were significantly higher than the values before treatment (medians and interquartile ranges of LSM values before and after treatment: 5.6, 5.3-6.3 kPa and, 6.4, 6.0-7.6 kPa, respectively, p<0.001). CONCLUSION: SWE can detect early changes in LSM in some CF patients treated with LUM/IVA.


Asunto(s)
Fibrosis Quística , Diagnóstico por Imagen de Elasticidad , Humanos , Niño , Fibrosis Quística/diagnóstico por imagen , Fibrosis Quística/tratamiento farmacológico , Fibrosis Quística/genética , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Mutación , Combinación de Medicamentos
2.
Eur J Radiol ; 157: 110557, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36274360

RESUMEN

PURPOSE: Chronic liver disease (CLD) is considered one of the main causes of death. Ultrasound Elastography (USE) is a CLD assessment imaging method. This study aims to evaluate a recently introduced commercial alternative of USE, Visual Transient Elastography (ViTE), and to compare it with three established USE methods, Vibration Controlled Transient Elastography (VCTE), Shear Wave Elastography (SWE) and Sound Touch Elastography (STE), using Liver Biopsy (LB) as 'Gold Standard'. METHOD: 152 consecutive subjects underwent a liver ViTE, VCTE, SWE and STE examination. A Receiver Operator Characteristic (ROC) analysis was performed on the measured stiffness values of each method. An inter- intra-observer analysis was also performed. RESULTS: The ViTE, VCTE, SWE and STE ROC analysis resulted in an AUC of 0.9481, 0.9900, 0.9621 and 0.9683 for F ≥ F1, 0.9698, 0.9767, 0.9931 and 0.9834 for F ≥ F2, 0.9846, 0.9651, 0.9835 and 0.9763 for F ≥ F3, and 0.9524, 0.9645, 0.9656, and 0.9509 for F = F4, respectively. ICC scores were 0.98 for Inter-observer and 0.97 for Intra-observer variability analysis. CONCLUSION: ViTE performance in CLD stage differentiation is comparable to the performance of VCTE, SWE and STE.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatopatías , Humanos , Biopsia , Diagnóstico por Imagen de Elasticidad/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Hepatopatías/diagnóstico por imagen , Hepatopatías/patología , Vibración
3.
Diagn Interv Radiol ; 28(5): 418-427, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36218147

RESUMEN

PURPOSE Non-alcoholic fatty liver disease (NAFLD) is the most widespread type of chronic liver disease in the Western countries. Ultrasound (US) is widely used for NAFLD staging. The Resona 7 US system (Mindray Bio-Medical Electronics Co., Ltd.) includes an image optimization and speed of ultrasound-related feature, Sound Speed Index (SSI). SSI is applied in a region of interest (ROI) that could potentially aid in tissue characterization. The purpose of this study is to evaluate the reliability of SSI on various examination parameters on normal subjects. METHODS Twenty normal subjects were examined by two radiologists performing SSI measurements in the liver in different ROI depths and sizes. Intraclass correlation coefficient (ICC) was calculated to measure intra- and inter-observer variability and inter-ROI variability. RESULTS For all ROIs and both radiologists, the mean inter-observer ICC was 0.62 and the mean intraobserver ICC was 0.52 and 0.79. The mean SSI values for all ROIs and examiners were in the range 1528.79-1540.16 m/s. CONCLUSION The results indicate that SSI can lead to reliable measurements on normal subjects, independent of ROI size but dependent on ROI placement. More studies processing NAFLD patients, utilizing reference methods of liver fat quantification either for reliability or correlation with SSI, should be performed to further investigate the relevance of the SSI as a potential biomarker in clinical practice for liver steatosis grading.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Humanos , Hígado/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Ultrasonografía
4.
Ultrasound Q ; 38(2): 124-132, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35353797

RESUMEN

OBJECTIVES: Nonalcoholic fatty liver disease (NAFLD) is the most widespread chronic liver disease type in the Western countries. Ultrasound (US) is used for NAFLD and hepatic steatosis (HS) grading. The most popular US method for NAFLD assessment is the hepatorenal index (HRI), but because of its limitations, other noninvasive methods have been developed. The Resona 7 US system has recently incorporated an US attenuation-related quantitative feature, liver ultrasound attenuation (LiSA), for HS estimation. The purpose of this study is to compare LiSA's and HRI's performance on NAFLD assessment. METHODS: A total of 159 NAFLD patients having a magnetic resonance imaging-proton density fat fraction (MRI-PDFF) examination were examined by 2 radiologists, who performed LiSA and HRI measurements in the liver. Correlation of LiSA's and HRI's measurements with MRI-PDFF values was calculated through Pearson correlation coefficient (PCC). To further investigate the performance of LiSA and HRI, optimum cutoffs, provided by the literature, were used to correspond HS grades to MRI-PDFF results. Moreover, a receiver operating characteristic (ROC) analysis on LiSA measurements and steatosis grades was performed. RESULTS: Magnetic resonance imaging-PDFF was better correlated with LiSA (PCC = 0.80) than HRI (PCC = 0.67). Receiver operating characteristic analysis showed better performance range for LiSA (77.8%-91.8%) than for HRI (72.8%-85.4%) on all HS grades for all studies used for corresponding MRI-PDFF values to HS grades. CONCLUSIONS: The results indicate that LiSA is more accurate than HRI in HS differentiation and can lead to more accurate grading of HS on NAFLD patients.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología , Curva ROC , Ultrasonografía/métodos
5.
Ultrasound Med Biol ; 46(4): 959-971, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31983484

RESUMEN

Chronic liver disease (CLD) is currently a major cause of death. Ultrasound elastography (USE) is an imaging method that has been developed for CLD assessment. Our aim in the study described here was to evaluate and compare a new commercial variant of USE, sound touch elastography (STE), with already established USE methods, shear wave elastography (SWE) and vibration-controlled transient elastography (VCTE), using liver biopsy as the "reference standard." For our study, 139 consecutive patients underwent standard liver STE, SWE and VCTE examinations with the corresponding ultrasound devices. A receiver operator characteristic (ROC) curve analysis was performed on the stiffness values measured with each method. ROC analysis revealed, for SWE, STE and VCTE, areas under the ROC curve of 0.9397, 0.9224 and 0.9348 for fibrosis stage (F), F ≥ F1; 0.9481, 0.9346 and 0.9415 for F ≥ F2; 0.9623, 0.9591 and 0.9631 for F ≥ F3; and 0.9581, 0.9541 and 0.9632 for F = F4, respectively. In conclusion, STE performs similarly to SWE and VCTE in CLD stage differentiation.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Enfermedad Hepática en Estado Terminal/diagnóstico por imagen , Hígado/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad Hepática en Estado Terminal/patología , Femenino , Humanos , Hígado/patología , Masculino , Persona de Mediana Edad , Estándares de Referencia , Reproducibilidad de los Resultados , Vibración , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA