Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Crit Rev Clin Lab Sci ; 60(7): 483-501, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37128734

RESUMEN

In the past decade a remarkable rebirth of serum/plasma lipoprotein(a) (Lp(a)) as an independent risk factor of cardiovascular disease (CVD) occurred. Updated evidence for a causal continuous association in different ethnic groups between Lp(a) concentrations and cardiovascular outcomes has been published in the latest European Atherosclerosis Society (EAS) Lp(a) consensus statement. Interest in measuring Lp(a) at least once in a person's lifetime moreover originates from the development of promising new Lp(a) lowering drugs. Accurate and clinically effective Lp(a) tests are of key importance for the timely detection of high-risk individuals and for future evaluation of the therapeutic effects of Lp(a) lowering medication. To this end, it is necessary to improve the performance and standardization of existing Lp(a) tests, as is also noted in the Lp(a) consensus statement. Consequently, a state-of-the-art internationally endorsed reference measurement system (RMS) must be in place that allows for performance evaluation of Lp(a) field tests in order to certify their validity and accuracy. An ELISA-based RMS from Northwest Lipid Research Laboratory (University of Washington, Seattle, USA) has been available since the 1990s. A next-generation apo(a)/Lp(a) RMS is now being developed by a working group from the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). The envisioned apo(a) RMS is based on the direct measurement of selected proteotypic fragments generated after proteolytic digestion using quantitative protein mass spectrometry (MS). The choice for an MS-based RMS enables selective measurement of the proteotypic peptides and is by design apo(a) isoform insensitive. Clearly, the equimolar conversion of apo(a) into the surrogate peptide measurands is required to obtain accurate Lp(a) results. The completeness of proteolysis under reaction conditions from the candidate reference measurement procedure (RMP) has been demonstrated for the quantifying apo(a) peptides. Currently, the candidate apo(a) RMP is endorsed by the IFCC and recommendations for suitable secondary reference materials have been made in a recent commutability study paper. Ongoing efforts toward a complete apo(a) RMS that is listed by the Joint Committee on Traceability in Laboratory Medicine (JCTLM) are focused on the peptide-based calibration and the establishment of a network of calibration laboratories running the apo(a) RMS in a harmonized way. Once completed, it will be the holy grail for evaluation and certification of Lp(a) field methods.

2.
Int J Mol Sci ; 23(20)2022 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-36293255

RESUMEN

The prospective, multicenter TESTBREAST study was initiated with the aim of identifying a novel panel of blood-based protein biomarkers to enable early breast cancer detection for moderate-to-high-risk women. Serum samples were collected every (half) year up until diagnosis. Protein levels were longitudinally measured to determine intrapatient and interpatient variabilities. To this end, protein cluster patterns were evaluated to form a conceptual basis for further clinical analyses. Using a mass spectrometry-based bottom-up proteomics strategy, the protein abundance of 30 samples was analyzed: five sequential serum samples from six high-risk women; three who developed a breast malignancy (cases) and three who did not (controls). Serum samples were chromatographically fractionated and an in-depth serum proteome was acquired. Cluster analyses were applied to indicate differences between and within protein levels in serum samples of individuals. Statistical analyses were performed using ANOVA to select proteins with a high level of clustering. Cluster analyses on 30 serum samples revealed unique patterns of protein clustering for each patient, indicating a greater interpatient than intrapatient variability in protein levels of the longitudinally acquired samples. Moreover, the most distinctive proteins in the cluster analysis were identified. Strong clustering patterns within longitudinal intrapatient samples have demonstrated the importance of identifying small changes in protein levels for individuals over time. This underlines the significance of longitudinal serum measurements, that patients can serve as their own controls, and the relevance of the current study set-up for early detection. The TESTBREAST study will continue its pursuit toward establishing a protein panel for early breast cancer detection.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/patología , Proteoma/metabolismo , Estudios Prospectivos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Proteínas Sanguíneas/análisis , Biomarcadores , Biomarcadores de Tumor
3.
Anal Chem ; 93(10): 4666-4675, 2021 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-33667082

RESUMEN

Carbohydrates, such as oligo- and polysaccharides, are highly abundant biopolymers that are involved in numerous processes. The study of their structure and functions is commonly based on a material that is isolated from complex natural sources. However, a more precise analysis requires pure compounds with well-defined structures that can be obtained from chemical or enzymatic syntheses. Novel synthetic strategies have increased the accessibility of larger monodisperse polysaccharides, posing a challenge to the analytical methods used for their molecular characterization. Here, we present wide mass range ultrahigh-resolution matrix-assisted laser desorption/ionization (MALDI) Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) as a powerful platform for the analysis of synthetic oligo- and polysaccharides. Synthetic carbohydrates 16-, 64-, 100-, and 151-mers were mass analyzed and characterized by MALDI in-source decay FT-ICR MS. Detection of fragment ions generated from glycosidic bond cleavage (or cross-ring cleavage) provided information of the monosaccharide content and the linkage type, allowing for the corroboration of the carbohydrate compositions and structures.


Asunto(s)
Carbohidratos , Polisacáridos , Análisis de Fourier , Glicósidos , Iones , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
4.
Glycoconj J ; 38(3): 387-395, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33877489

RESUMEN

Breast cancer is the most prevalent cancer in women. Early detection of this disease improves survival and therefore population screenings, based on mammography, are performed. However, the sensitivity of this screening modality is not optimal and new screening methods, such as blood tests, are being explored. Most of the analyses that aim for early detection focus on proteins in the bloodstream. In this study, the biomarker potential of total serum N-glycosylation analysis was explored with regard to detection of breast cancer. In an age-matched case-control setup serum protein N-glycan profiles from 145 breast cancer patients were compared to those from 171 healthy individuals. N-glycans were enzymatically released, chemically derivatized to preserve linkage-specificity of sialic acids and characterized by high resolution mass spectrometry. Logistic regression analysis was used to evaluate associations of specific N-glycan structures as well as N-glycosylation traits with breast cancer. In a case-control comparison three associations were found, namely a lower level of a two triantennary glycans and a higher level of one tetraantennary glycan in cancer patients. Of note, various other N-glycomic signatures that had previously been reported were not replicated in the current cohort. It was further evaluated whether the lack of replication of breast cancer N-glycomic signatures could be partly explained by the heterogenous character of the disease since the studies performed so far were based on cohorts that included diverging subtypes in different numbers. It was found that serum N-glycan profiles differed for the various cancer subtypes that were analyzed in this study.


Asunto(s)
Biomarcadores de Tumor/sangre , Neoplasias de la Mama/sangre , Polisacáridos/sangre , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Persona de Mediana Edad , Polisacáridos/clasificación , Polisacáridos/metabolismo
5.
Int J Mol Sci ; 22(5)2021 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-33800786

RESUMEN

Pancreatic ductal adenocarcinoma (PDAC) is known as a highly aggressive malignant disease. Prognosis for patients is notoriously poor, despite improvements in surgical techniques and new (neo)adjuvant chemotherapy regimens. Early detection of PDAC may increase the overall survival. It is furthermore foreseen that precision medicine will provide improved prognostic stratification and prediction of therapeutic response. In this review, omics-based discovery efforts are presented that aim for novel diagnostic and prognostic biomarkers of PDAC. For this purpose, we systematically evaluated the literature published between 1999 and 2020 with a focus on protein- and protein-glycosylation biomarkers in pancreatic cancer patients. Besides genomic and transcriptomic approaches, mass spectrometry (MS)-based proteomics and glycomics of blood- and tissue-derived samples from PDAC patients have yielded new candidates with biomarker potential. However, for reasons discussed in this review, the validation and clinical translation of these candidate markers has not been successful. Consequently, there has been a change of mindset from initial efforts to identify new unimarkers into the current hypothesis that a combination of biomarkers better suits a diagnostic or prognostic panel. With continuing development of current research methods and available techniques combined with careful study designs, new biomarkers could contribute to improved detection, prognosis, and prediction of pancreatic cancer.


Asunto(s)
Biomarcadores de Tumor/análisis , Carcinoma Ductal Pancreático/diagnóstico , Glicómica/métodos , Glicoproteínas/análisis , Espectrometría de Masas/métodos , Proteínas de Neoplasias/análisis , Neoplasias Pancreáticas/diagnóstico , Proteómica/métodos , Líquidos Corporales/química , Carcinoma Ductal Pancreático/química , Carcinoma Ductal Pancreático/genética , Carcinoma Ductal Pancreático/mortalidad , Toma de Decisiones Clínicas , Diagnóstico Diferencial , Detección Precoz del Cáncer , Humanos , Síndromes Neoplásicos Hereditarios/diagnóstico , Síndromes Neoplásicos Hereditarios/epidemiología , Síndromes Neoplásicos Hereditarios/genética , Neoplasias Pancreáticas/química , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/mortalidad , Pancreatitis Crónica/diagnóstico , Lesiones Precancerosas/diagnóstico , Medicina de Precisión , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Factores de Riesgo
6.
J Proteome Res ; 19(7): 2708-2716, 2020 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-32142289

RESUMEN

Elevated serum prostate-specific antigen (PSA) levels in body fluids may indicate prostate cancer (PCa), but it is noted that the clinical performance is rather poor. Specificity and sensitivity values of 20 and 94% at a cutoff value of 4.1 ng/mL, respectively, result in overdiagnosis and unnecessary interventions. Previous exploratory studies have indicated that the glycosylation of PSA potentially leads to improved PCa diagnosis based on qualitative analyses. However, the applied methods are not suited for a quantitative evaluation or implementation in a medical laboratory. Therefore, in this proof-of-principle study, we have evaluated the use of hydrophilic interaction liquid chromatography (HILIC) in combination with targeted quantitative mass spectrometry for the sialic acid linkage-specific analysis of PSA glyco-proteoforms based on either trypsin or ArgC peptides. The efficiency of PSA proteolysis was optimized as well as the glycopeptide separation conditions (buffer type, strength, and pH). The HILIC-based analysis of PSA glyco-proteoforms presented here has the potential for the clinical validation of patient cohorts. The method shows the feasibility of the use of a HILIC stationary phase for the separation of isomeric glycopeptides to detect specific glyco-proteoforms. This is the first step toward the development and evaluation of PSA glyco-proteoforms for use in a clinical chemistry setting aiming for improved PCa diagnosis or screening.


Asunto(s)
Glicopéptidos , Antígeno Prostático Específico , Cromatografía Liquida , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Masculino , Espectrometría de Masas
7.
Anal Chem ; 92(18): 12429-12436, 2020 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-32803948

RESUMEN

The development of various ionization and fragmentation techniques has been of key importance for establishing mass spectrometry (MS) as a powerful tool for protein characterization. One example of this is matrix-assisted laser desorption/ionization (MALDI) combined with in-source decay (ISD) fragmentation that allows mapping of N- and C-terminal regions of large proteins without the need for proteolysis. Positive ion mode ISD fragments are commonly assigned in the mass region above m/z 1000, while MALDI matrix ions generally hamper the detection of smaller singly charged fragments. The ultrahigh resolving power provided by Fourier transform ion cyclotron resonance (FT-ICR) MS partially overcomes this limitation, but to further increase the detection of smaller fragments we have revisited the application of negative ion mode MALDI-ISD and found good coverage of the peptide chain termini starting from c'2 and z'2 fragment ions. For the first time, we demonstrate that the combination of negative and positive ion MALDI FT-ICR MS is a useful tool to improve the characterization of mAbs. The different specificities of the two ion modes allowed us to selectively cover the sequence of the light and heavy chains of mAbs at increased sensitivity. A comprehensive evaluation of positive and negative ion mode MALDI-ISD FT-ICR MS in the m/z range 46-13 500 showed an increased sequence coverage for three standard proteins, namely, myoglobin, SiLuLite mAb, and NIST mAb. The data obtained in the two ion modes were, in part, complementary.


Asunto(s)
Anticuerpos Monoclonales/análisis , Mioglobina/análisis , Animales , Caballos , Conformación Proteica , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
8.
Anal Chem ; 92(8): 5871-5881, 2020 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-32212639

RESUMEN

Comprehensive determination of primary sequence and identification of post-translational modifications (PTMs) are key elements in protein structural analysis. Various mass spectrometry (MS) based fragmentation techniques are powerful approaches for mapping both the amino acid sequence and PTMs; one of these techniques is matrix-assisted laser desorption/ionization (MALDI), combined with in-source decay (ISD) fragmentation and Fourier-transform ion cyclotron resonance (FT-ICR) MS. MALDI-ISD MS protein analysis involves only minimal sample preparation and does not require spectral deconvolution. The resulting MALDI-ISD MS data is complementary to electrospray ionization-based MS/MS sequencing readouts, providing knowledge on the types of fragment ions is available. In this study, we evaluate the isotopic distributions of z' ions in protein top-down MALDI-ISD FT-ICR mass spectra and show why these distributions can deviate from theoretical profiles as a result of co-occurring and isomeric z and y-NH3 ions. Two synthetic peptides, containing either normal or deuterated alanine residues, were used to confirm the presence and unravel the identity of isomeric z and y-NH3 fragment ions ("twins"). Furthermore, two reducing MALDI matrices, namely 1,5-diaminonaphthalene and N-phenyl-p-phenylenediamine were applied that yield ISD mass spectra with different fragment ion distributions. This study demonstrates that the relative abundance of isomeric z and y-NH3 ions requires consideration for accurate and confident assignments of z' ions in MALDI-ISD FT-ICR mass spectra.


Asunto(s)
Amoníaco/química , Insulina/análisis , Mioglobina/análisis , 2-Naftilamina/análogos & derivados , 2-Naftilamina/química , 2-Naftilamina/metabolismo , Amoníaco/metabolismo , Animales , Caballos , Humanos , Insulina/metabolismo , Iones/química , Iones/metabolismo , Estructura Molecular , Mioglobina/metabolismo , Fenilendiaminas/química , Fenilendiaminas/metabolismo , Procesamiento Proteico-Postraduccional , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Espectrometría de Masas en Tándem
9.
Anal Chem ; 91(3): 2079-2085, 2019 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-30571088

RESUMEN

The emergence of complex protein therapeutics in general and monoclonal antibodies (mAbs) in particular have stimulated analytical chemists to develop new methods and strategies for their structural characterization. Mass spectrometry plays a key role in providing information on the primary amino acid sequence, post-translational modifications, and other structure characteristics that must be monitored during the manufacturing process and subsequent quality control assessment. In this study, we present a novel method that allows structural characterization of mAbs based on MALDI in-source decay (ISD) fragmentation, coupled with Fourier transform ion cyclotron resonance (FT-ICR) MS. The method benefits from higher resolution of absorption mode FT mass spectra, compared to magnitude mode, which enables simultaneous identification of ISD fragments from both the heavy and light chains with a higher confidence in a wide mass range up to m/ z 13 500. This method was applied to two standard mAbs, namely NIST mAb and trastuzumab, in preparation for method application in an interlaboratory study on mAbs structural analysis coordinated by the Consortium for Top-Down Proteomics. Extensive sequence coverage was obtained from the middle-down analysis (IdeS- and GingisKHAN-digested mAbs) that complemented the top-down analysis of intact mAbs. In addition, MALDI FT-ICR MS of IdeS-digested mAbs allowed isotopic-level profiling of proteoforms with regard to heavy chain N-glycosylation.


Asunto(s)
Anticuerpos Monoclonales/análisis , Análisis de Fourier , Conformación Proteica , Procesamiento Proteico-Postraduccional , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
10.
Anal Chem ; 90(20): 11955-11961, 2018 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-30230816

RESUMEN

High-throughput mass spectrometry (MS) glycomics is an emerging field driven by technological advancements including sample preparation and data processing. Previously, we reported an automated protocol for the analysis of N-glycans released from plasma proteins that included sialic acid derivatization with linkage-specificity, namely, ethylation of α2,6-linked sialic acid residues and lactone formation of α2,3-linked sialic acids. In the current study, each step in this protocol was further optimized. Method improvements included minimizing the extent of side-reaction during derivatization, an adjusted glycan purification strategy and mass analysis of the released N-glycans by ultrahigh resolution matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance MS. The latter resolved peak overlap and simplified spectral alignment due to high mass measurement precision. Moreover, this resulted in more confident glycan assignments and improved signal-to-noise for low-abundant species. The performance of the protocol renders high-throughput applications feasible in the exciting field of clinical glycomics.


Asunto(s)
Automatización , Proteínas Sanguíneas/química , Ácido N-Acetilneuramínico/química , Polisacáridos/sangre , Glicómica , Glicosilación , Humanos , Espectrometría de Masas , Polisacáridos/química
11.
Anal Chem ; 88(11): 5996-6003, 2016 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-27123572

RESUMEN

The introduction of standardized matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) platforms in the medical microbiological practice has revolutionized the way microbial species identification is performed on a daily basis. To a large extent, this is due to the ease of operation. Acquired spectra are compared to profiles obtained from cultured colonies present in a reference spectra database. It is fast and reliable, and costs are low compared to previous diagnostic approaches. However, the low resolution and dynamic range of the MALDI-TOF profiles have shown limited applicability for the discrimination of different bacterial strains, as achieved with typing based on genetic markers. This is pivotal in cases where certain strains are associated with, e.g., virulence or antibiotic resistance. Ultrahigh resolution MALDI-FTICR MS allows the measurement of small proteins at isotopic resolution and can be used to analyze complex mixtures with increased dynamic range and higher precision than MALDI-TOF MS, while still generating results in a similar time frame. Here, we propose to use ultrahigh resolution 15T MALDI-Fourier transform ion cyclotron resonance (FTICR) MS to discriminate clinically relevant bacterial strains after species identification performed by MALDI-TOF MS. We used a collection of well characterized Pseudomonas aeruginosa strains, featuring distinct antibiotic resistance profiles, and isolates obtained during hospital outbreaks. Following cluster analysis based on amplification fragment length polymorphism (AFLP), these strains were grouped into three different clusters. The same clusters were obtained using protein profiles generated by MALDI-FTICR MS. Subsequent intact protein analysis by electrospray ionization (ESI)-collision-induced dissociation (CID)-FTICR MS was applied to identify protein isoforms that contribute to the separation of the different clusters, illustrating the additional advantage of this analytical platform.


Asunto(s)
Pseudomonas aeruginosa/clasificación , Pseudomonas aeruginosa/aislamiento & purificación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Análisis del Polimorfismo de Longitud de Fragmentos Amplificados , Proteínas Bacterianas/química , Proteínas Bacterianas/aislamiento & purificación , Análisis por Conglomerados , Pseudomonas aeruginosa/química , Pseudomonas aeruginosa/genética
12.
Expert Rev Proteomics ; 13(12): 1063-1071, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27798968

RESUMEN

INTRODUCTION: Advances in mass spectrometry (MS)-based proteomic strategies have resulted in robust protein biomarker discovery studies often performed on high resolution accurate mass (HRAM) platforms. For successful translation of promising protein biomarkers into useful clinical tests, trans-sector networks and collaboration among stakeholders involved in the biomarker pipeline are urgently needed. Areas covered: In this perspective, literature- and empirical evidence is combined with author's opinions to discuss the progress of ultrahigh resolution MS and provide insight in its potential for validation and development of clinical tests. Expert commentary: Thus far two 'low resolution' MS strategies have been implemented in the clinic: quantification of proteins using triple quadrupole instruments and identification of unknown microorganisms using comparative analysis with spectral libraries on MALDI-TOF instruments. The rise of HRAM technology further boosts the potential of MS-based tests for detection and quantitation of disease-specific biomarkers which meet the analytical performance specifications needed for clinical assays.


Asunto(s)
Espectrometría de Masas/métodos , Proteínas/análisis , Proteómica/métodos , Biomarcadores/análisis , Glicosilación , Humanos , Proteínas/química , Proteínas/metabolismo , Sensibilidad y Especificidad
13.
Clin Chem ; 62(1): 188-97, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26585923

RESUMEN

BACKGROUND: Direct and calculated measures of lipoprotein fractions for cardiovascular risk assessment suffer from analytical inaccuracy in certain dyslipidemic and pathological states, most commonly hypertriglyceridemia. LC-MS/MS has proven suitable for multiplexed quantification and phenotyping of apolipoproteins. We developed and provisionally validated an automated assay for quantification of apolipoprotein (apo) A-I, B, C-I, C-II, C-III, and E and simultaneous qualitative assessment of apoE phenotypes. METHODS: We used 5 value-assigned human serum pools for external calibration. Serum proteins were denatured, reduced, and alkylated according to standard mass spectrometry-based proteomics procedures. After trypsin digestion, peptides were analyzed by LC-MS/MS. For each peptide, we measured 2 transitions. We compared LC-MS/MS results to those obtained by an immunoturbidimetric assay or ELISA. RESULTS: Intraassay CVs were 2.3%-5.5%, and total CVs were 2.5%-5.9%. The LC-MS/MS assay correlated (R = 0.975-0.995) with immunoturbidimetric assays with Conformité Européenne marking for apoA-I, apoB, apoC-II, apoC-III, and apoE in normotriglyceridemic (n = 54) and hypertriglyceridemic (n = 46) sera. Results were interchangeable for apoA-I ≤3.0 g/L (Deming slope 1.014) and for apoB-100 ≤1.8 g/L (Deming slope 1.016) and were traceable to higher-order standards. CONCLUSIONS: The multiplex format provides an opportunity for new diagnostic and pathophysiologic insights into types of dyslipidemia and allows a more personalized approach for diagnosis and treatment of lipid abnormalities.


Asunto(s)
Apolipoproteínas/sangre , Automatización , Dislipidemias/sangre , Dislipidemias/diagnóstico , Fenotipo , Espectrometría de Masas en Tándem , Cromatografía Líquida de Alta Presión , Ensayo de Inmunoadsorción Enzimática , Humanos , Nefelometría y Turbidimetría , Proteómica
14.
Rapid Commun Mass Spectrom ; 30(6): 731-8, 2016 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-26864526

RESUMEN

RATIONALE: Peptide tandem mass spectra can be analyzed by a number of means. They can be compared against predicted spectra of peptides derived from genome sequences, compared against previously acquired and identified spectra, or - sometimes - sequenced de novo. We recently introduced another method which compares spectra between liquid chromatography/tandem mass spectrometry (LC/MS/MS) datasets to determine the shared spectral content, and demonstrated how this can be applied in a molecular phylogenetic study using sera from human and non-human primates. We will here explore if such a method have other, serendipitous uses. METHODS: We used the existing compareMS2 algorithm without modification on a diverse set of experiments. RESULTS: First we conducted a small phylogenetic study, using (mammalian) bone samples to study old material, and human pathogens aiming to distinguish clinically important strains. Although not as straightforward as primate sera analysis, the method shows significant promise for all these applications. We also used the algorithm to compare 24 different protocols for extraction of proteins from muscle tissue. The results provided useful information in comparing protocols. Finally, we applied compareMS2 aiming for quality control of two traceable protein reference standards (troponin) used in clinical chemistry assays, by analysing the effect of storage conditions. CONCLUSIONS: The results illustrate a broad applicability of the metric based on shared tandem mass spectra between LC/MS/MS datasets for analysing protein digests in different types of experiments. There is no reason to assume that our instance of this method is optimal in any of these situations, as it makes limited or no use of accurate mass and chromatographic retention time. We propose that with further improvement and refinement, this type of analysis can be applied as a simple but informative first step in many pipelines for bottom-up tandem mass spectrometry data analysis in proteomics and other fields, comparing or analysing large numbers of samples or datasets.


Asunto(s)
Cromatografía Liquida/métodos , Biología Molecular/métodos , Filogenia , Espectrometría de Masas en Tándem/métodos , Animales , Biomarcadores/análisis , Humanos
15.
Methods ; 81: 74-85, 2015 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-25766926

RESUMEN

A fully automated workflow was developed and validated for simultaneous quantification of the cardiovascular disease risk markers apolipoproteins A-I (apoA-I) and B-100 (apoB-100) in clinical sera. By coupling of stable-isotope standards and capture by anti-peptide antibodies (SISCAPA) for enrichment of proteotypic peptides from serum digests to matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS detection, the standardized platform enabled rapid, liquid chromatography-free quantification at a relatively high throughput of 96 samples in 12h. The average imprecision in normo- and triglyceridemic serum pools was 3.8% for apoA-I and 4.2% for apoB-100 (4 replicates over 5 days). If stored properly, the MALDI target containing enriched apoA-1 and apoB-100 peptides could be re-analyzed without any effect on bias or imprecision for at least 7 days after initial analysis. Validation of the workflow revealed excellent linearity for daily calibration with external, serum-based calibrators (R(2) of 0.984 for apoA-I and 0.976 for apoB-100 as average over five days), and absence of matrix effects or interference from triglycerides, protein content, hemolysates, or bilirubins. Quantification of apoA-I in 93 normo- and hypertriglyceridemic clinical sera showed good agreement with immunoturbidimetric analysis (slope = 1.01, R(2) = 0.95, mean bias = 4.0%). Measurement of apoB-100 in the same clinical sera using both methods, however, revealed several outliers in SISCAPA-MALDI-TOF-MS measurements, possibly as a result of the lower MALDI-TOF-MS signal intensity (slope = 1.09, R(2) = 0.91, mean bias = 2.0%). The combination of analytical performance, rapid cycle time and automation potential validate the SISCAPA-MALDI-TOF-MS platform as a valuable approach for standardized and high-throughput quantification of apoA-I and apoB-100 in large sample cohorts.


Asunto(s)
Apolipoproteína A-I/sangre , Apolipoproteína B-100/sangre , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Anticuerpos Monoclonales , Apolipoproteína A-I/inmunología , Apolipoproteína B-100/inmunología , Biomarcadores/sangre , Calibración , Humanos , Flujo de Trabajo
16.
J Proteome Res ; 14(9): 4080-6, 2015 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-26179816

RESUMEN

Glycosylation is a post-translational modification of key importance with heterogeneous structural characteristics. Previously, we have developed a robust, high-throughput MALDI-TOF-MS method for the comprehensive profiling of human plasma N-glycans. In this approach, sialic acid residues are derivatized with linkage-specificity, namely the ethylation of α2,6-linked sialic acid residues with parallel lactone formation of α2,3-linked sialic acids. In the current study, this procedure was used as a starting point for the automation of all steps on a liquid-handling robot system. This resulted in a time-efficient and fully standardized procedure with throughput times of 2.5 h for a first set of 96 samples and approximately 1 h extra for each additional sample plate. The mass analysis of the thus-obtained glycans was highly reproducible in terms of relative quantification, with improved interday repeatability as compared to that of manual processing.


Asunto(s)
Automatización/métodos , Glicoproteínas/sangre , Glicoproteínas/química , Ensayos Analíticos de Alto Rendimiento/métodos , Ácido N-Acetilneuramínico/metabolismo , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Esterificación , Glicoproteínas/metabolismo , Glicosilación , Ácido N-Acetilneuramínico/química , Reproducibilidad de los Resultados
17.
J Proteome Res ; 14(2): 928-42, 2015 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-25494833

RESUMEN

Clinically actionable quantification of protein biomarkers by mass spectrometry (MS) requires analytical performance in concordance with quality specifications for diagnostic tests. Laboratory-developed tests should, therefore, be validated in accordance with EN ISO 15189:2012 guidelines for medical laboratories to demonstrate competence and traceability along the entire workflow, including the selected standardization strategy and the phases before, during, and after proteolysis. In this study, bias and imprecision of a previously developed MS method for quantification of serum apolipoproteins A-I (Apo A-I) and B (Apo B) were thoroughly validated according to Clinical and Laboratory Standards Institute (CLSI) guidelines EP15-A2 and EP09-A3, using 100 patient sera and either stable-isotope labeled (SIL) peptides or SIL-Apo A-I as internal standard. The systematic overview of error components assigned sample preparation before the first 4 h of proteolysis as major source (∼85%) of within-sample imprecision without external calibration. No improvement in imprecision was observed with the use of SIL-Apo A-I instead of SIL-peptides. On the contrary, when the use of SIL-Apo A-I was combined with external calibration, imprecision improved significantly (from ∼9% to ∼6%) as a result of the normalization for matrix effects on linearity. A between-sample validation of bias in 100 patient sera further supported the presence of matrix effects on digestion completeness and additionally demonstrated specimen-specific biases associated with modified peptide sequences or alterations in protease activity. In conclusion, the presented overview of bias and imprecision components contributes to a better understanding of the sources of errors in MS-based protein quantification and provides valuable recommendations to assess and control analytical quality in concordance with the requirements for clinical use.


Asunto(s)
Fragmentos de Péptidos/análisis , Fragmentos de Péptidos/normas , Proteómica/métodos , Proteómica/normas , Proteínas Sanguíneas/análisis , Proteínas Sanguíneas/química , Cromatografía Liquida , Humanos , Marcaje Isotópico , Fragmentos de Péptidos/sangre , Fragmentos de Péptidos/química , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem , Tripsina
18.
Anal Chem ; 87(6): 3429-37, 2015 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-25719938

RESUMEN

An accurate mass measurement of a known protein provides information on potential amino acid deletions and post-translational modifications. Although this field is dominated by strategies based on electrospray ionization, mass spectrometry (MS) methods using matrix-assisted laser desorption/ionization (MALDI) have the advantage of yielding predominantly singly charged precursor ions, thus avoiding peak overlap from different charge states of multiple species. Such MALDI-MS methods require mass measurement at ultrahigh resolution, which is provided by Fourier transform ion cyclotron resonance (FTICR) mass analyzers. Recently, using a MALDI-FTICR-MS platform equipped with a 15 T magnet, we reported on the mass analysis of intact human serum peptides and small proteins with isotopic resolution up to ∼15 kDa and identified new proteoforms from an accurate measurement of mass distances. In the current study, we have used this FTICR system after an upgrade with a novel dynamically harmonized ICR cell, i.e., ParaCell, for mapping isotopically resolved intact proteins up to about 17 kDa and performed top-down MALDI in-source decay (ISD) analysis. Standard proteins myoglobin (m/z-value 16,950) and ribonuclease B (m/z-value 14,900) were measured with resolving powers of 62,000 and 61,000, respectively. Furthermore, it will be shown that (singly charged) MALDI-ISD fragment ions can be measured at isotopic resolution up to m/z-value 12,000 (e.g., resolving power 39,000 at m/z-value 12,000) providing more reliable identifications. Moreover, examples are presented of pseudo-MS(3) experiments on ISD fragment ions from RNase B by collisional-induced dissociation (CID).


Asunto(s)
Ciclotrones , Análisis de Fourier , Mioglobina/química , Ribonucleasas/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Secuencia de Aminoácidos , Animales , Bovinos , Isótopos , Datos de Secuencia Molecular , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación
19.
Anal Bioanal Chem ; 407(22): 6637-55, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26123437

RESUMEN

In this study, we characterized unexpected side-products in a commercially synthesized peptide with the sequence RPRTRLHTHRNR. This so-called peptide D3 was selected by mirror phage display against low molecular weight amyloid-ß-peptide (Aß) associated with Alzheimer's disease. Capillary electrophoresis (CE) was the method of choice for structure analysis because the extreme hydrophilicity of the peptide did not allow reversed-phase liquid chromatography (RPLC) and hydrophilic interaction stationary phases (HILIC). CE-MS analysis, applying a strongly acidic background electrolyte and different statically adsorbed capillary coatings, provided fast and efficient analysis and revealed that D3 unexpectedly showed strong ion-pairing with sulfuric acid. Moreover, covalent O-sulfonation at one or two threonine residues was identified as a result of a side reaction during peptide synthesis, and deamidation was found at either the asparagine residue or at the C-terminus. In total, more than 10 different species with different m/z values were observed. Tandem-MS analysis with collision induced dissociation (CID) using a CE-quadrupole-time-of-flight (QTOF) setup predominantly resulted in sulfate losses and did not yield any further characteristic fragment ions at high collision energies. Therefore, direct infusion Fourier transform ion cyclotron resonance (FT-ICR) MS was employed to identify the covalent modification and discriminate O-sulfonation from possible O-phosphorylation by using an accurate mass analysis. Electron transfer dissociation (ETD) was used for the identification of the threonine O-sulfation sites. In this work, it is shown that the combination of CE-MS and FT-ICR-MS with ETD fragmentation was essential for the full characterization of this extremely basic peptide with labile modifications.


Asunto(s)
Electroforesis Capilar/métodos , Mapeo Peptídico/métodos , Péptidos/química , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Ácidos Sulfónicos/química , Sitios de Unión , Interacciones Hidrofóbicas e Hidrofílicas , Unión Proteica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Sulfatos/química
20.
Int J Mol Sci ; 16(11): 27133-44, 2015 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-26580595

RESUMEN

Fourier transform mass spectrometry (FTMS) is the method of choice for measurements that require ultra-high resolution. The establishment of Fourier transform ion cyclotron resonance (FTICR) MS, the availability of biomolecular ionization techniques and the introduction of the Orbitrap™ mass spectrometer have widened the number of FTMS-applications enormously. One recent example involves clinical proteomics using FTICR-MS to discover and validate protein biomarker signatures in body fluids such as serum or plasma. These biological samples are highly complex in terms of the type and number of components, their concentration range, and the structural identity of each species, and thus require extensive sample cleanup and chromatographic separation procedures. Clearly, such an elaborate and multi-step sample preparation process hampers high-throughput analysis of large clinical cohorts. A final MS read-out at ultra-high resolution enables the analysis of a more complex sample and can thus simplify upfront fractionations. To this end, FTICR-MS offers superior ultra-high resolving power with accurate and precise mass-to-charge ratio (m/z) measurement of a high number of peptides and small proteins (up to 20 kDa) at isotopic resolution over a wide mass range, and furthermore includes a wide variety of fragmentation strategies to characterize protein sequence and structure, including post-translational modifications (PTMs). In our laboratory, we have successfully applied FTICR "next-generation" peptide profiles with the purpose of cancer disease classifications. Here we will review a number of developments and innovations in FTICR-MS that have resulted in robust and routine procedures aiming for ultra-high resolution signatures of clinical samples, exemplified with state-of-the-art examples for serum and saliva.


Asunto(s)
Líquidos Corporales/metabolismo , Análisis de Fourier , Espectrometría de Masas/métodos , Proteoma , Proteómica/métodos , Líquidos Corporales/química , Humanos , Péptidos/química , Péptidos/metabolismo , Proteínas/química , Proteínas/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA