Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1253-1263, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38488225

RESUMEN

PURPOSE: This clinical fluoroscopy study investigated knee kinematics of two different cemented fixed-bearing, posterior-stabilised (PS) total knee arthroplasty (TKA) designs: an asymmetric tibial component including an asymmetric insert designed to optimise personalised balance and fit and its precursor symmetrical design with symmetric insert. METHODS: A consecutive series of patients (16 TKAs from each treatment group) participating in a randomised controlled trial comparing TKA migration was included. The exclusion criterion was the use of walking aids. Flat-panel fluoroscopic recordings of step-up and lunge motions were acquired 1-year postoperatively. Medial and lateral contact points (CPs) were determined to calculate CP displacement, femoral axial rotation and pivot position. Using linear mixed-effects modelling techniques, kinematics between TKA designs were compared. RESULTS: During knee extension between 20° flexion and full extension, the CPs moved anteriorly combined with a small internal femoral rotation (a screw-home mechanism). Whereas CP movement was reversed: femoral rollback, external femoral rotation while flexing the knee between full extension and 20° knee flexion, At larger flexion angles, femoral axial rotation (FAR) occurred around a lateral pivot point both during step-up and lunge. The symmetric design had a 2.3° larger range of FAR compared to the asymmetric design during lunge (p = 0.02). All other kinematics were comparable. CONCLUSION: Despite the differences in design, this study showed that the asymmetric and symmetric PS TKA designs had mostly comparable knee kinematics during step-up and lunge motions. It is therefore expected that the functionality of the successor TKA design is similar to that of its precursor design. LEVEL OF EVIDENCE: Level II, prospective comparative study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Diseño de Prótesis , Rango del Movimiento Articular , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Fluoroscopía , Fenómenos Biomecánicos , Femenino , Masculino , Anciano , Tibia/cirugía , Persona de Mediana Edad , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Rotación , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/fisiopatología
2.
Bone Joint J ; 103-B(5): 855-863, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33934647

RESUMEN

AIMS: The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). METHODS: A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively. RESULTS: A linear mixed-effect model using RSA data of 31 asymmetrical and 38 symmetrical TKAs did not show a difference in mean MTPM migration pattern of the tibial or femoral components. Mean tibial component MTPM at two years postoperative of the asymmetrical TKA design was 0.93 mm and 1.00 mm for the symmetrical design. For the femoral component these values were 1.04 mm and 1.14 mm, respectively. No significant differences were observed in other migration parameters or in clinical and PROM measurements. CONCLUSION: The TKA design with an asymmetrical tibial component has comparable component migration with the proven TKA with a symmetrical tibial component. This suggests the risk of long-term aseptic loosening of the two designs is comparable. Cite this article: Bone Joint J 2021;103-B(5):855-863.


Asunto(s)
Migración de Cuerpo Extraño/diagnóstico por imagen , Prótesis de la Rodilla , Diseño de Prótesis , Análisis Radioestereométrico , Adulto , Anciano , Anciano de 80 o más Años , Artritis Reumatoide/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Falla de Prótesis
3.
Rheumatol Ther ; 8(1): 499-515, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33608843

RESUMEN

INTRODUCTION: Likely due to ignored heterogeneity in disease pathophysiology, osteoarthritis (OA) has become the most common disabling joint disease, without effective disease-modifying treatment causing a large social and economic burden. In this study we set out to explore responses of aged human osteochondral explants upon different OA-related perturbing triggers (inflammation, hypertrophy and mechanical stress) for future tailored biomimetic human models. METHODS: Human osteochondral explants were treated with IL-1ß (10 ng/ml) or triiodothyronine (T3; 10 nM) or received 65% strains of mechanical stress (65% MS). Changes in chondrocyte signalling were determined by expression levels of nine genes involved in catabolism, anabolism and hypertrophy. Breakdown of cartilage was measured by sulphated glycosaminoglycans (sGAGs) release, scoring histological changes (Mankin score) and mechanical properties of cartilage. RESULTS: All three perturbations (IL-1ß, T3 and 65% MS) resulted in upregulation of the catabolic genes MMP13 and EPAS1. IL-1ß abolished COL2A1 and ACAN gene expression and increased cartilage degeneration, reflected by increased Mankin scores and sGAGs released. Treatment with T3 resulted in a high and significant upregulation of the hypertrophic markers COL1A1, COL10A1 and ALPL. However, 65% MS increased sGAG release and detrimentally altered mechanical properties of cartilage. CONCLUSION: We present consistent and specific output on three different triggers of OA. Perturbation with the pro-inflammatory IL-1ß mainly induced catabolic chondrocyte signalling and cartilage breakdown, while T3 initiated expression of hypertrophic and mineralization markers. Mechanical stress at a strain of 65% induced catabolic chondrocyte signalling and changed cartilage matrix integrity. The major strength of our ex vivo models was that they considered aged, preserved, human cartilage of a heterogeneous OA patient population. As a result, the explants may reflect a reliable biomimetic model prone to OA onset allowing for development of different treatment modalities.

4.
Int Orthop ; 33(5): 1255-61, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18758777

RESUMEN

We evaluated the influence of CT-free or CT-based computer assisted orthopaedic surgery (CAOS) on the alignment of total knee prostheses (TK) and micromotion of tibial components. This randomised study compared 19 CT-free, 17 CT-based CAOS TK, and a matched control group of 21 conventionally placed TK. Using Roentgen stereophotogrammetric analysis (RSA) the migration was measured. The alignment and component positions were measured on radiographs. No significant difference in leg and tibial component alignment was present between the three groups. A significant difference was found for micromotion in subsidence, with the conventional group having a mean of 0.16 mm, compared to the CT-free group at 0.01 mm and the CT-based group at -0.05 mm. No clinical significant difference in alignment was found between CAOS and conventionally operated TK. More subsidence of the tibial component was seen in the conventional group compared to both CAOS groups at two year follow-up.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Cementos para Huesos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Cirugía Asistida por Computador , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Cementación , Humanos , Inestabilidad de la Articulación/fisiopatología , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Estudios Prospectivos , Falla de Prótesis , Reproducibilidad de los Resultados , Tibia , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA