Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.378
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Gastroenterology ; 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38494035

RESUMEN

BACKGROUND & AIMS: Hirschsprung's disease is defined by the absence of the enteric nervous system (ENS) from the distal bowel. Primary treatment is "pull-through" surgery to remove bowel that lacks ENS, with reanastomosis of "normal" bowel near the anal verge. Problems after pull-through are common, and some may be due to retained hypoganglionic bowel (ie, low ENS density). Testing this hypothesis has been difficult because counting enteric neurons in tissue sections is unreliable, even for experts. Tissue clearing and 3-dimensional imaging provide better data about ENS structure than sectioning. METHODS: Regions from 11 human colons and 1 ileal specimen resected during Hirschsprung's disease pull-through surgery were cleared, stained with antibodies to visualize the ENS, and imaged by confocal microscopy. Control distal colon from people with no known bowel problems were similarly cleared, stained, and imaged. RESULTS: Quantitative analyses of human colon, ranging from 3 days to 60 years old, suggest age-dependent changes in the myenteric plexus area, ENS ganglion area, percentage of myenteric plexus occupied by ganglia, neurons/mm2, and neuron Feret's diameter. Neuron counting using 3-dimensional images was highly reproducible. High ENS density in neonatal colon allowed reliable neuron counts using 500-µm2 × 500-µm2 regions (36-fold smaller than in adults). Hirschsprung's samples varied 8-fold in proximal margin enteric neuron density and had diverse ENS architecture in resected bowel. CONCLUSIONS: Tissue clearing and 3-dimensional imaging provide more reliable information about ENS structure than tissue sections. ENS structure changes during childhood. Three-dimensional ENS anatomy may provide new insight into human bowel motility disorders, including Hirschsprung's disease.

2.
J Hepatol ; 80(6): 941-956, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38365182

RESUMEN

BACKGROUND & AIMS: The PNPLA3 rs738409 C>G (encoding for I148M) variant is a risk locus for the fibrogenic progression of chronic liver diseases, a process driven by hepatic stellate cells (HSCs). We investigated how the PNPLA3 I148M variant affects HSC biology using transcriptomic data and validated findings in 3D-culture models. METHODS: RNA sequencing was performed on 2D-cultured primary human HSCs and liver biopsies of individuals with obesity, genotyped for the PNPLA3 I148M variant. Data were validated in wild-type (WT) or PNPLA3 I148M variant-carrying HSCs cultured on 3D extracellular matrix (ECM) scaffolds from human healthy and cirrhotic livers, with/without TGFB1 or cytosporone B (Csn-B) treatment. RESULTS: Transcriptomic analyses of liver biopsies and HSCs highlighted shared PNPLA3 I148M-driven dysregulated pathways related to mitochondrial function, antioxidant response, ECM remodelling and TGFB1 signalling. Analogous pathways were dysregulated in WT/PNPLA3-I148M HSCs cultured in 3D liver scaffolds. Mitochondrial dysfunction in PNPLA3-I148M cells was linked to respiratory chain complex IV insufficiency. Antioxidant capacity was lower in PNPLA3-I148M HSCs, while reactive oxygen species secretion was increased in PNPLA3-I148M HSCs and higher in bioengineered cirrhotic vs. healthy scaffolds. TGFB1 signalling followed the same trend. In PNPLA3-I148M cells, expression and activation of the endogenous TGFB1 inhibitor NR4A1 were decreased: treatment with the Csn-B agonist increased total NR4A1 in HSCs cultured in healthy but not in cirrhotic 3D scaffolds. NR4A1 regulation by TGFB1/Csn-B was linked to Akt signalling in PNPLA3-WT HSCs and to Erk signalling in PNPLA3-I148M HSCs. CONCLUSION: HSCs carrying the PNPLA3 I148M variant have impaired mitochondrial function, antioxidant responses, and increased TGFB1 signalling, which dampens antifibrotic NR4A1 activity. These features are exacerbated by cirrhotic ECM, highlighting the dual impact of the PNPLA3 I148M variant and the fibrotic microenvironment in progressive chronic liver diseases. IMPACT AND IMPLICATIONS: Hepatic stellate cells (HSCs) play a key role in the fibrogenic process associated with chronic liver disease. The PNPLA3 genetic mutation has been linked with increased risk of fibrogenesis, but its role in HSCs requires further investigation. Here, by using comparative transcriptomics and a novel 3D in vitro model, we demonstrate the impact of the PNPLA3 genetic mutation on primary human HSCs' behaviour, and we show that it affects the cell's mitochondrial function and antioxidant response, as well as the antifibrotic gene NR4A1. Our publicly available transcriptomic data, 3D platform and our findings on NR4A1 could facilitate the discovery of targets to develop more effective treatments for chronic liver diseases.


Asunto(s)
Matriz Extracelular , Células Estrelladas Hepáticas , Lipasa , Cirrosis Hepática , Proteínas de la Membrana , Factor de Crecimiento Transformador beta1 , Humanos , Células Estrelladas Hepáticas/metabolismo , Células Estrelladas Hepáticas/patología , Proteínas de la Membrana/genética , Proteínas de la Membrana/metabolismo , Matriz Extracelular/metabolismo , Matriz Extracelular/genética , Lipasa/genética , Lipasa/metabolismo , Cirrosis Hepática/genética , Cirrosis Hepática/patología , Cirrosis Hepática/metabolismo , Factor de Crecimiento Transformador beta1/metabolismo , Factor de Crecimiento Transformador beta1/genética , Células Cultivadas , Hígado/patología , Hígado/metabolismo , Transducción de Señal/genética , Obesidad/genética , Obesidad/metabolismo , Masculino , Aciltransferasas , Fosfolipasas A2 Calcio-Independiente
3.
J Cardiovasc Electrophysiol ; 35(2): 366-369, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38044489

RESUMEN

INTRODUCTION: In patients with prior atrial septal defect (ASD) closure and atrial tachyarrhythmias, transseptal puncture can be challenging. METHODS AND RESULTS: This case report discusses a 65-year-old man who had previously undergone pulmonary vein isolation (PVI) and cavo-tricuspid isthmus ablation for atrial fibrillation before ASD closure, respectively. He developed atrial tachycardia (AT) and underwent catheter ablation. AT was diagnosed as peri-mitral flutter and the mitral isthmus (MI) linear ablation via a trans-aortic approach successfully terminated it. CONCLUSION: This case demonstrates the feasibility and safety of transaortic MI linear ablation in patients with ASD closure devices or anatomical challenges when transseptal puncture is difficult.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Defectos del Tabique Interatrial , Taquicardia Supraventricular , Masculino , Humanos , Anciano , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/cirugía , Atrios Cardíacos , Taquicardia/cirugía , Ablación por Catéter/efectos adversos
4.
J Cardiovasc Electrophysiol ; 35(6): 1061-1068, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38501564

RESUMEN

INTRODUCTION: The relationships between baseline tissue local impedance (LI), contact force (CF), atrial fibrosis, and atrial rhythm are uninvestigated in a clinical setting. We compared the relationship of LI and CF between atrial fibrillation (AF) and sinus rhythm (SR) accounting for the effects of atrial fibrosis as assessed by bipolar voltage and LI. METHODS: Patients undergoing persistent AF ablation were recruited. LI was recorded referenced to patient blood pool (LIr) and concurrent to changes in CF, with data collected at the same locations in AF and SR. RESULTS: Twenty patients were recruited. 109 locations were sampled obtaining 1903 data points (SR: 966, AF: 937). CF correlated strongly with LI (repeated measures correlation = 0.64). The relationship between CF and LIr was logarithmic. Rhythm and CF had a significant main (both p < .0005) and interaction effect (p = .022) on tissue LI: AF demonstrated higher LIr values than SR for similar CF. Bipolar voltage had no effect on the relationship of CF to LIr in either rhythm. Assessing fibrosis using LIr showed an interaction effect with CF for LIr in SR and AF, (SR: p < .0005, AF: p = .01), with increased fibrosis showing lesser change in LIr per gram of CF. CONCLUSIONS: CF and rhythm significantly affect the measured LIr of LA myocardium. Optimal catheter-tissue coupling may be better achieved with higher levels of CF and in AF rather than SR. Atrial fibrosis, as assessed by LIr but not bipolar voltage, affected the CF-LI relationship.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Función del Atrio Izquierdo , Ablación por Catéter , Fibrosis , Atrios Cardíacos , Frecuencia Cardíaca , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Atrios Cardíacos/fisiopatología , Anciano , Factores de Tiempo , Técnicas Electrofisiológicas Cardíacas , Impedancia Eléctrica , Valor Predictivo de las Pruebas , Resultado del Tratamiento , Remodelación Atrial
5.
Artículo en Inglés | MEDLINE | ID: mdl-39011961

RESUMEN

INTRODUCTION: Patients with viral myocarditis can present with challenging life-threatening arrhythmias. Catheter ablation can be a life-saving procedure in some patients with recurrent drug-refractory ventricular arrhythmias. METHODS AND RESULTS: A patient with three prior ablations targeting two different monomorphic ventricular tachycardias (MMVTs) presented with recurrent ventricular tachycardia (VT). Consequently, he underwent epicardial mapping with adjuvant AI-enabled CT images with the creation of a three-dimensional model, which demonstrated a midmyocardial scar. Fractionated potentials were noted during mapping in this region, and entrainment suggested an inner loop. Interestingly, pacing showed two different QRS morphologies identical to his previously ablated VTs with a long stim-QRS at this region. Epicardial ablation carried on during the VT successfully terminated it, but the VT remained inducible and required endocardial ablation to make it noninducible. CONCLUSION: This case emphasizes the importance of recognizing possible three-dimensional VT circuits in some patients and the need to understand and target mid-myocardial substrate from both the endocardium and epicardium to achieve the elimination of the VT circuits.

6.
BMC Cancer ; 24(1): 741, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38890682

RESUMEN

BACKGROUND: Sarcopenia is characterized by reduced skeletal muscle volume and is a condition that is prevalent among elderly patients and associated with poor prognosis as a comorbidity in malignancies. Given the aging population over 80 years old in Japan, an understanding of malignancies, including colorectal cancer (CRC), complicated by sarcopenia is increasingly important. Therefore, the focus of this study is on a novel and practical diagnostic approach of assessment of psoas major muscle volume (PV) using 3-dimensional computed tomography (3D-CT) in diagnosis of sarcopenia in patients with CRC. METHODS: The subjects were 150 patients aged ≥ 80 years with CRC who underwent primary tumor resection at Juntendo University Hospital between 2004 and 2017. 3D-CT measurement of PV and conventional CT measurement of the psoas major muscle cross-sectional area (PA) were used to identify sarcopenia (group S) and non-sarcopenia (group nS) cases. Clinicopathological characteristics, operative results, postoperative complications, and prognosis were compared between these groups. RESULTS: The S:nS ratios were 15:135 for the PV method and 52:98 for the PA method. There was a strong positive correlation (r = 0.66, p < 0.01) between PVI (psoas major muscle volume index) and PAI (psoas major muscle cross-sectional area index), which were calculated by dividing PV or PA by the square of height. Surgical results and postoperative complications did not differ significantly in the S and nS groups defined using each method. Overall survival was worse in group S compared to group nS identified by PV (p < 0.01), but not significantly different in groups S and nS identified by PA (p = 0.77). A Cox proportional hazards model for OS identified group S by PV as an independent predictor of a poor prognosis (p < 0.05), whereas group S by PA was not a predictor of prognosis (p = 0.60). CONCLUSIONS: The PV method for identifying sarcopenia in elderly patients with CRC is more practical and sensitive for prediction of a poor prognosis compared to the conventional method.


Asunto(s)
Neoplasias Colorrectales , Imagenología Tridimensional , Músculos Psoas , Sarcopenia , Tomografía Computarizada por Rayos X , Humanos , Sarcopenia/diagnóstico por imagen , Sarcopenia/patología , Músculos Psoas/diagnóstico por imagen , Músculos Psoas/patología , Masculino , Femenino , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/complicaciones , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/diagnóstico por imagen , Anciano de 80 o más Años , Tomografía Computarizada por Rayos X/métodos , Imagenología Tridimensional/métodos , Pronóstico , Tamaño de los Órganos , Japón/epidemiología , Estudios Retrospectivos
7.
Catheter Cardiovasc Interv ; 103(1): 243-247, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37855193

RESUMEN

A mitral paravalvular leak (PVL) is a significant complication of surgical valve replacement that has a profound impact on the health and survival of patients. Transcatheter closure of PVL has emerged as a promising treatment option. We present the case of a 65-year-old patient who experienced exertional dyspnea, chest tightness, and peripheral edema (New York Heart Association functional class Ⅵ) following surgical aortic and mitral valve replacement. Echocardiography and computed tomography performed on admission revealed a giant mitral PVL (1 bundle, volume 25.0 mL, area 13.0 cm²). Due to the patient's high surgical risk and complex anatomical characteristics, a patient-specific three-dimensional printed model was utilized to visualize anatomical structures and simulate the main procedures. After careful consideration, the surgical team opted to perform transcatheter closure of the giant mitral PVL via a transapical concomitant transseptal approach using two carefully selected devices of different sizes (14-mm and 16-mm Amplatzer Vascular Plug II). The procedure was carried out successfully. During the 1-month follow-up, the patient remained asymptomatic (New York Heart Association functional class Ⅰ). Transcatheter closure of a giant and complex mitral PVL utilizing three-dimensional printing guidance has proven to be a feasible approach.


Asunto(s)
Ecocardiografía Tridimensional , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Anciano , Falla de Prótesis , Resultado del Tratamiento , Cateterismo Cardíaco
8.
Artículo en Inglés | MEDLINE | ID: mdl-38984675

RESUMEN

A 32-year-old man, who was treated for T-cell lymphoma, presented in cardiac arrest. He had been treated for heart failure with reduced ejection fraction. Veno-arterial extracorporeal membrane oxygenation was initiated immediately. We diagnosed him as non-ST elevated myocardial infarction. Coronary angiography demonstrated the occlusion of the trifurcation in the proximal left anterior descending artery (LAD). We failed to advance the first guidewire into the distal LAD by angio-based conventional wiring. Intravascular ultrasonography (IVUS) of the proximal diagonal branch revealed two diaphragms separating the distal lumen without connection, which looks like lotus root-like appearance. We quickly penetrated the plaque using IVUS-based real-time 3D wiring using the tip detection method. The contrast injection via the microcatheter showed the distal diagonal branch (D2). After the balloon dilation in D2, IVUS image revealed a torn plaque between D2 and the distal LAD. Subsequently we advanced the guidewire to the distal LAD using IVUS-based real-time 3D wiring using the tip detection method through the tear of the plaque. Finally, we successfully performed the revascularization of LAD in a preferable procedure time. The patient recovered well and was discharged 39 days after cardiac arrest. This case highlights the efficacy of IVUS-based real-time 3D wiring using the tip detection method even in the emergent and challenging situation.

9.
Am J Obstet Gynecol ; 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38838912

RESUMEN

BACKGROUND: A major goal of contemporary obstetrical practice is to optimize fetal growth and development throughout pregnancy. To date, fetal growth during prenatal care is assessed by performing ultrasonographic measurement of 2-dimensional fetal biometry to calculate an estimated fetal weight. Our group previously established 2-dimensional fetal growth standards using sonographic data from a large cohort with multiple sonograms. A separate objective of that investigation involved the collection of fetal volumes from the same cohort. OBJECTIVE: The Fetal 3D Study was designed to establish standards for fetal soft tissue and organ volume measurements by 3-dimensional ultrasonography and compare growth trajectories with conventional 2-dimensional measures where applicable. STUDY DESIGN: The National Institute of Child Health and Human Development Fetal 3D Study included research-quality images of singletons collected in a prospective, racially and ethnically diverse, low-risk cohort of pregnant individuals at 12 U.S. sites, with up to 5 scans per fetus (N=1730 fetuses). Abdominal subcutaneous tissue thickness was measured from 2-dimensional images and fetal limb soft tissue parameters extracted from 3-dimensional multiplanar views. Cerebellar, lung, liver, and kidney volumes were measured using virtual organ computer aided analysis. Fractional arm and thigh total volumes, and fractional lean limb volumes were measured, with fractional limb fat volume calculated by subtracting lean from total. For each measure, weighted curves (fifth, 50th, 95th percentiles) were derived from 15 to 41 weeks' using linear mixed models for repeated measures with cubic splines. RESULTS: Subcutaneous thickness of the abdomen, arm, and thigh increased linearly, with slight acceleration around 27 to 29 weeks. Fractional volumes of the arm, thigh, and lean limb volumes increased along a quadratic curvature, with acceleration around 29 to 30 weeks. In contrast, growth patterns for 2-dimensional humerus and femur lengths demonstrated a logarithmic shape, with fastest growth in the second trimester. The mid-arm area curve was similar in shape to fractional arm volume, with an acceleration around 30 weeks, whereas the curve for the lean arm area was more gradual. The abdominal area curve was similar to the mid-arm area curve with an acceleration around 29 weeks. The mid-thigh and lean area curves differed from the arm areas by exhibiting a deceleration at 39 weeks. The growth curves for the mid-arm and thigh circumferences were more linear. Cerebellar 2-dimensional diameter increased linearly, whereas cerebellar 3-dimensional volume growth gradually accelerated until 32 weeks followed by a more linear growth. Lung, kidney, and liver volumes all demonstrated gradual early growth followed by a linear acceleration beginning at 25 weeks for lungs, 26 to 27 weeks for kidneys, and 29 weeks for liver. CONCLUSION: Growth patterns and timing of maximal growth for 3-dimensional lean and fat measures, limb and organ volumes differed from patterns revealed by traditional 2-dimensional growth measures, suggesting these parameters reflect unique facets of fetal growth. Growth in these three-dimensional measures may be altered by genetic, nutritional, metabolic, or environmental influences and pregnancy complications, in ways not identifiable using corresponding 2-dimensional measures. Further investigation into the relationships of these 3-dimensional standards to abnormal fetal growth, adverse perinatal outcomes, and health status in postnatal life is warranted.

10.
J Surg Res ; 300: 425-431, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38861866

RESUMEN

INTRODUCTION: Three-dimensional printing (3DP) is being integrated into surgical practice at a significant pace, from preprocedural planning to procedure simulation. 3DP is especially useful in surgical education, where printed models are highly accurate and customizable. The aim of this study was to evaluate how 3DP is being integrated most recently into surgical residency training. METHODS: We performed a structured literature search of the OVID/MEDLINE, EMBASE, and PUBMED databases following the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles published from 2016 to 2023 that met predefined inclusion and exclusion criteria were included. Data extracted included surgical subspecialty using 3DP, application of 3DP, and any reported satisfaction measures of trainees. A thorough analysis of pooled data was performed to evaluate satisfaction rates among studies. RESULTS: A total of 85 studies were included. The median number of participants was 18 (interquartile range 10-27). Fourteen surgical disciplines were represented, with ear, nose, and throat/otolaryngology having the highest recorded utilization of 3DP models among residents and medical students (22.0%), followed by neurosurgery (14.0%) and urology (12.0%). 3DP models were created most frequently to model soft tissue (35.3%), bone (24.7%), vessel (14.1%), mixed (16.4%), or whole organs (6.66%) (Fig.1). Feedback from trainees was overwhelmingly positive regarding the fidelity of the models and their support for integration into their training programs. Among trainees, the combined satisfaction rate with their use in the curriculum was 95% (95% confidence interval, 0.92-0.97), and the satisfaction rate with the model fidelity was 90% (95% confidence interval, 0.86-0.94). CONCLUSIONS: There is wide variation in the surgical specialties utilizing 3DP models in training. These models are effective in increasing trainee comfort with both common and rare scenarios and are associated with a high degree of resident support and satisfaction. Plastic surgery programs may benefit from the integration of this technology, potentially strengthening future surgical curricula. Objective evaluations of their pedagogic effects on residents are areas of future research.


Asunto(s)
Internado y Residencia , Impresión Tridimensional , Humanos , Internado y Residencia/estadística & datos numéricos , Internado y Residencia/métodos , Modelos Anatómicos , Entrenamiento Simulado/métodos , Entrenamiento Simulado/estadística & datos numéricos
11.
J Endovasc Ther ; : 15266028241248600, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38708986

RESUMEN

PURPOSE: The primary aim of this study was to assess the 3-dimensional flare geometry of the Gore Viabahn VBX balloon-expandable covered stent (BECS) after fenestrated endovascular aortic repair (FEVAR) and to determine and visualize BECS-associated complications. METHODS: This multicenter retrospective study included patients who underwent FEVAR between 2018 and 2022 in 3 vascular centers participating in the VBX Expand Registry. Patients with at least one visceral artery treated with the VBX and with availability of 2 post-FEVAR computed tomography angiography (CTA) scans (follow-up [FU] 1: 0-6 months; FU2: 9-24 months) were included. The flare geometry of the VBX, including flare-to-fenestration distance, flare-to-fenestration diameter ratio, flare angle, and apposition with the target artery were assessed using a vascular workstation and dedicated CTA applied software. RESULTS: In total, 90 VBX BECS were analyzed in 43 FEVAR patients. The median CTA FU for FU1 and FU2 was 35 days (interquartile range [IQR], 29-51 days) and 14 months (IQR, 13-15 months), respectively. The mean flare-to-fenestration distance was 5.6±2.0 mm on FU1 and remained unchanged at 5.7±2.0 mm on FU2 (p=.417). The flare-to-fenestration diameter ratio was 1.19±0.17 on FU1 and remained unchanged at 1.21±0.19 (p=.206). The mean apposition length was 18.6±5.3 mm on FU1 and remained 18.6±5.3 mm (p=.550). The flare angle was 31°±15° on FU1 and changed to 33°±16° (p=.009). On FU1, the BECS-associated complication rate was 1%, and the BECS-associated reintervention rate was 0%. On FU2, the BECS-associated complication rate was 3%, and the BECS-associated reintervention rate was 1%. CONCLUSIONS: The flare geometry of the VBX bridging stent did not change significantly during 14 months follow-up in this study. Three-dimensional geometric analysis of the flare may contribute to identify the origin of endoleaks and occlusions, but this should be confirmed in a larger study including enough patients and BECS to compare complicated and uncomplicated cases. CLINICAL IMPACT: The three-dimensional flare geometry of the Gore Viabahn VBX BECS was assessed on the first and second postoperative CTA scans, and geometrical changes during this period were identified. For BECS that were diagnosed with a type 3c endoleak or occlusion, the BECS geometry was analyzed to detect geometrical components that were related to the complication. Geometric analysis of the flare may help to better detect and identify the cause of such complications.

12.
Artículo en Inglés | MEDLINE | ID: mdl-38430486

RESUMEN

The majority of the cavotricuspid isthmus (CTI) region consists of discretely arranged muscle bundles separated by connective tissue. Heterogeneity in the anatomic arrangement of the muscle bundles results in differences in the endocardial and epicardial activation patterns. We present a case of recurrent atrial flutter (AFL) despite the presence of a complete endocardial CTI block. We found epicardial-endocardial breakthrough (EEB) sites on the right atrial high septum. In addition, the epicardial excitation confirmed by endocardial activation mapping was detected as far-field potentials. Radiofrequency ablation was performed at the EEB site. No AFL has recurred for 12 months after the present procedure.

13.
Echocardiography ; 41(3): e15799, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38516862

RESUMEN

Atherosclerosis is the most common cause of heart disease and stroke. Plaque thickness ≥4 mm in the ascending aorta or aortic arch is strongly correlated with cerebral embolic events and ischemic stroke. However, despite imaging workup, the cause of embolic stroke remains unidentified in many patients. Transesophageal echocardiography (TEE) is the preferred echocardiographic method for the evaluation of cardiac source of emboli. 2D TEE imaging evaluates aortic root and aortic arch in a single plane or two planes with biplane imaging. However, 2D TEE often fails to detect mobile or complex components in the ascending aorta and aortic arch plaques. The routine availability of 3D TEE in current ultrasound systems may significantly improve the assessment of aortic plaques as a potential embolic source. In this case series, we present four consecutive patients with stroke who underwent TEE by a single cardiologist for possible cardioembolic source. Some of these patients may have been labelled as "cryptogenic stroke" or "embolic stroke of undetermined source" (ESUS) due to the presence of insignificant or nonmobile ascending aortic or aortic arch plaques on 2D TEE imaging. In our four consecutive patients with ESUS who underwent TEE by a single operator, 3D TEE showed complex aortic arch plaques with ulceration with mobile components and established these plaques as the likely source of embolic stroke.


Asunto(s)
Enfermedades de la Aorta , Aterosclerosis , Accidente Cerebrovascular Embólico , Embolia , Placa Aterosclerótica , Accidente Cerebrovascular , Humanos , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Accidente Cerebrovascular Embólico/complicaciones , Aterosclerosis/complicaciones , Aterosclerosis/diagnóstico por imagen , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Embolia/complicaciones , Enfermedades de la Aorta/complicaciones , Enfermedades de la Aorta/diagnóstico por imagen
14.
BMC Musculoskelet Disord ; 25(1): 558, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39020301

RESUMEN

PURPOSE: This prospective study aimed to compare the postoperative evaluation of the quadrant method measuring four points and Bernard method in femoral tunnel position evaluation on 3-Dimensional (3D) reconstructed computed tomography (CT) following the arthroscopic single-bundle anterior cruciate ligament (ACL) reconstruction. METHODS: Thirty-eight patients with ACL tears that were reconstructed using single-bundle ACL reconstruction between May 2021 and March 2023 were included in this study. Postoperative 3D CT images were obtained after the operation. The femoral tunnel position was measured by use of the quadrant method measuring four points and Bernard method. RESULTS: Average mean position of the femoral tunnel insertion center on the 3D CT image was at 26.16 ± 6.27% in the x-coordinate and at 24.36 ± 5.52% in the y-coordinate according to the Bernard method. Meanwhile, the position of the femoral insertion of the ACL measured by the quadrant method measuring four points was 24.2% ± 6.86% in the x-coordinate and 21.16% ± 5.14% in the y-coordinate. CONCLUSIONS: Both the quadrant method measuring four points and Bernard method were effective in femoral tunnel position evaluation on 3D reconstructed CT. Application of the quadrant method measuring four points on 3D CT showed the advantage that measurement can be taken regardless of the shape of the bone tunnel.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Fémur , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Humanos , Reconstrucción del Ligamento Cruzado Anterior/métodos , Imagenología Tridimensional/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Masculino , Femenino , Adulto , Tomografía Computarizada por Rayos X/métodos , Estudios Prospectivos , Adulto Joven , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Adolescente , Artroscopía/métodos , Persona de Mediana Edad , Ligamento Cruzado Anterior/cirugía , Ligamento Cruzado Anterior/diagnóstico por imagen
15.
Curr Cardiol Rep ; 26(1): 1-14, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38091195

RESUMEN

PURPOSE OF THE REVIEW: The role of multimodality imaging in the evaluation of patients with aortic regurgitation is summarized in this review. RECENT FINDINGS: The etiology (mechanism) of the aortic regurgitation and the severity of aortic regurgitation and hemodynamic consequences are key in the decision making of patients with severe aortic regurgitation. While echocardiography remains as the leading technique to assess all these parameters, other imaging techniques have become essential for the accurate assessment of aortic regurgitation severity and the timing of aortic intervention. The anatomic suitability of transcatheter aortic valve implantation in inoperable patients with severe aortic regurgitation is usually assessed with computed tomography. Aortic regurgitation is a prevalent disease with various pathophysiological mechanisms that need a personalized treatment. The evaluation of the mechanism and severity of aortic regurgitation can be initially performed with echocardiography. Three-dimensional techniques, including echocardiography, have become very relevant for accurate assessment of the regurgitation severity and its hemodynamic consequences. Assessment of myocardial tissue characteristics with cardiac magnetic resonance is key in the risk stratification of patients and in the timing of aortic intervention. Computed tomography is important in the assessment of aortic dimensions and selection of patients for transcatheter aortic valve implantation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Ecocardiografía/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Tomografía Computarizada por Rayos X , Corazón , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Cateterismo Cardíaco/métodos
16.
J Shoulder Elbow Surg ; 33(2): e58-e67, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37506998

RESUMEN

BACKGROUND: Several techniques have been adopted during primary reverse shoulder arthroplasty (RSA) to manage glenoid bone defect. Among bone grafts, humeral head autograft is currently the mainstream option. However, autologous humeral heads may be unavailable or inadequate, and allografts may be a viable alternative. The aim of the present study was to evaluate the functional and radiologic outcomes of femoral head allografts for glenoid bone defects in primary RSA. METHODS: We conducted a retrospective study with prospective data collection enrolling 20 consecutive patients who underwent RSA with femoral head allografts for glenoid bone defects. Indications for surgery were eccentric cuff tear arthropathy in 10 cases (50%), concentric osteoarthritis in 9 cases (45%), and fracture sequelae in 1 case (5%). Each patient was evaluated preoperatively and at follow-up by radiologic and computed tomography (CT) and by assessing the range of motion (ROM) and the Constant-Murley score (CMS). A CT-based software, a patient-specific 3D model of the scapula, and patient-specific instrumentation were used to shape the graft and to assess the position of K-wire for the central peg. Postoperatively, CT scans were used to identify graft incorporation and resorption. RESULTS: After a median follow-up of 26.5 months (24-38), ROM and CMS showed a statistically significant improvement (all P = .001). The median measures of the graft were as follows: 28 mm (28-29) for diameter, 22° (10°-31°) for angle, 4 mm (2-8 mm) for minimum thickness, and 15 mm (11-21 mm) for maximum thickness. Before the surgery, the median glenoid version was 21.8° (16.5°-33.5°) for the retroverted glenoids and -13.5° (-23° to -12°) for the anteverted glenoids. At the follow-up, the median postoperative baseplate retroversion was 5.7° (2.2°-1.5°) (P = .001), and this value was close to the 4° retroversion planned on the preoperative CT-based software. Postoperative major complications were noted in 4 patients: 2 dislocations, 1 baseplate failure following a high-energy trauma, and 1 septic baseplate failure. Partial graft resorption without glenoid component failure was observed in 3 cases that did not require revision surgery. CONCLUSION: The femoral head allograft for glenoid bone loss in primary RSA restores shoulder function, with CMS values comparable to those of sex- and age-matched healthy individuals. A high rate of incorporation of the graft and satisfactory correction of the glenoid version can be expected after surgery. The management of glenoid bone defects remains a challenging procedure, and a 15% risk of major complication must be considered.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Artroplastía de Reemplazo de Hombro/efectos adversos , Cabeza Femoral/trasplante , Estudios Retrospectivos , Escápula/cirugía , Complicaciones Posoperatorias/etiología , Aloinjertos/cirugía , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Resultado del Tratamiento , Rango del Movimiento Articular
17.
J Arthroplasty ; 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38360279

RESUMEN

BACKGROUND: Hydroxyapatite-coated, triple-tapered, shorter-length stems with a medial collar have been reported with good results for a few years. We investigated whether contact between the medial collar and femoral neck affects clinical outcomes and changes in bone mineral density (BMD) in patients who have this type of stem in their total hip arthroplasty construct. METHODS: This was a retrospective, single-center study involving 62 patients scheduled for unilateral total hip arthroplasty using a hydroxyapatite-coated, triple-tapered, shorter-length stem who were followed for at least 1 year postoperatively. All patients had a Dorr type B femoral canal shape. Contact between the medial collar and the femoral neck was evaluated by computed tomography at the third postoperative month, and patients were classified into 2 groups. Postoperative clinical outcomes were investigated by the Western Ontario and McMaster Universities Arthritis Index and the Japanese Orthopaedic Association scores; radiological evaluation included stem fixation, spot welds and cortical hypertrophy, postoperative 3-dimensional stem alignment, and periprosthetic BMD changes. RESULTS: There were 51 patients in the Contact + group (collar and neck contact) and 11 in the Contact-group (no contact). There were no differences between the 2 groups in the improvement of Western Ontario and McMaster Universities Arthritis Index and Japanese Orthopaedic Association scores, stem fixation, occurrence of cortical hypertrophy, or 3-dimensional stem alignment. Radiolucent lines were present in zones 3, 4, and 5 in 6 patients (12%) in the Contact + group only, who had no statistical difference between the 2 groups. Bone mineral density (BMD) decreased most in zone 7 in both groups, with no difference between the 2 groups. CONCLUSIONS: The presence or absence of contact between the medial collar and femoral neck did not affect postoperative BMD changes or radiological or clinical results. LEVEL OF EVIDENCE: Therapeutic Level III.

18.
Nano Lett ; 23(23): 10998-11005, 2023 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-38048073

RESUMEN

We describe here the fabrication of large-area molecular junctions with a configuration of ITO/[Ru(Phen)3]/Al to understand temperature- and thickness-dependent charge transport phenomena. Thanks to the electrochemical technique, thin layers of electroactive ruthenium(II)-tris(phenanthroline) [Ru(Phen)3] with thicknesses of 4-16 nm are covalently grown on sputtering-deposited patterned ITO electrodes. The bias-induced molecular junctions exhibit symmetric current-voltage (j-V) curves, demonstrating highly efficient long-range charge transport and weak attenuation with increased molecular film thickness (ß = 0.70 to 0.79 nm-1). Such a lower ß value is attributed to the accessibility of Ru(Phen)3 molecular conduction channels to Fermi levels of both the electrodes and a strong electronic coupling at ITO-molecules interfaces. The thinner junctions (d = 3.9 nm) follow charge transport via resonant tunneling, while the thicker junctions (d = 10-16 nm) follow thermally activated (activation energy, Ea ∼ 43 meV) Poole-Frenkel charge conduction, showing a clear "molecular signature" in the nanometric junctions.

19.
Surg Innov ; 31(3): 256-262, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38565982

RESUMEN

OBJECTIVE: In this case report, the auxiliary role of deep learning and 3-dimensional printing technology in the perioperative period was discussed to guide transcatheter aortic valve replacement and coronary stent implantation simultaneously. CASE PRESENTATION: A 68-year-old man had shortness of breath and chest tightness, accompanied by paroxysmal nocturnal dyspnea, 2 weeks before presenting at our hospital. Echocardiography results obtained in the outpatient department showed severe aortic stenosis combined with regurgitation and pleural effusion. The patient was first treated with closed thoracic drainage. After 800 mL of pleural effusion was collected, the patient's symptoms were relieved and he was admitted to the hospital. Preoperative transthoracic echocardiography showed severe bicuspid aortic valve stenosis combined with calcification and aortic regurgitation (mean pressure gradient, 42 mmHg). Preoperative computed tomography results showed a type I bicuspid aortic valve with severe eccentric calcification. The leaflet could be seen from the left coronary artery plane, which indicated an extremely high possibility of coronary obstruction. After preoperative imaging assessment, deep learning and 3-dimensional printing technology were used for evaluation and simulation. Guided transcatheter aortic valve replacement and a coronary stent implant were completed successfully. Postoperative digital subtraction angiography showed that the bioprosthesis and the chimney coronary stent were in ideal positions. Transesophageal echocardiography showed normal morphology without paravalvular regurgitation. CONCLUSION: The perioperative guidance of deep learning and 3-dimensional printing are of great help for surgical strategy formulation in patients with severe bicuspid aortic valve stenosis with calcification and high-risk coronary obstruction.


Asunto(s)
Estenosis de la Válvula Aórtica , Aprendizaje Profundo , Impresión Tridimensional , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Stents , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/anomalías , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen
20.
Aesthetic Plast Surg ; 48(3): 398-406, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38133836

RESUMEN

BACKGROUND: The paranasal depression is a common facial feature of Oriental populations. One of the most wildly used method to improve it was paranasal augmentation using expanded polytetrafluoroethylene (ePTFE). The effectiveness of it should be tested by three-dimensional morphological measurements. METHODS: Patients who underwent paranasal augmentation using ePTFE between January 2017 and December 2022 were recruited in the study. The preoperative and postoperative clinical variables and three-dimensional measurement of patients were also collected. The satisfaction outcome were assessed. RESULTS: By establishing a coordinate system based on the Frankfurt plane, 16 landmarks including nasal alar crest, subnasal point, upper lip, pogonion, glabella, sub-cheek, orbitale, tragion in left and right side of faces were marked. Five segments, 4 ratios, and 3 angles were measured based on it. The significant increase of segments, ratios, and angles indicated that paranasal augmentation could increase the protrusion of paranasal area, both in absolute value and relative proportion. The significant decrease of other data indicated that the protrusion difference between paranasal base and upper lip, forehead, and chin, respectively, were shortened after surgery. The average size of implant was 6.54 ± 1.02 mm, and the average increase of paranasal height was 4.38 ± 1.04 mm postoperatively. This indicates that two-thirds of its height will ultimately be reflected effectively in the sagittal elevation of the paranasal base. CONCLUSIONS: Paranasal augmentation using ePTFE could effectively increase paranasal height and improve subunits relationships, and the ePTFE prosthesis should be designed and carve considering the 1/3 loss of height after implantation. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Asunto(s)
Politetrafluoroetileno , Prótesis e Implantes , Humanos , Estudios de Cohortes , Estudios de Seguimiento , Resultado del Tratamiento , Estudios Retrospectivos , Estética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA