Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Magn Reson Med ; 90(5): 1844-1858, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37392413

RESUMEN

PURPOSE: To enable free-breathing and high isotropic resolution liver quantitative susceptibility mapping (QSM) using 3D multi-echo UTE cones acquisition and respiratory motion-resolved image reconstruction. METHODS: Using 3D multi-echo UTE cones MRI, a respiratory motion was estimated from the k-space center of the imaging data. After sorting the k-space data with estimated motion, respiratory motion state-resolved reconstruction was performed for multi-echo data followed by nonlinear least-squares fitting for proton density fat fraction (PDFF), R 2 * $$ {\mathrm{R}}_2^{\ast } $$ , and fat-corrected B0 field maps. PDFF and B0 field maps were subsequently used for QSM reconstruction. The proposed method was compared with motion-averaged (gridding) reconstruction and conventional 3D multi-echo Cartesian MRI in moving gadolinium phantom and in vivo studies. Region of interest (ROI)-based linear regression analysis was performed on these methods to investigate correlations between gadolinium concentration and QSM in the phantom study and between R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and QSM in in vivo study. RESULTS: Cones with motion-resolved reconstruction showed sharper image quality compared to motion-averaged reconstruction with a substantial reduction of motion artifacts in both moving phantom and in vivo studies. For ROI-based linear regression analysis of the phantom study, susceptibility values from cones with motion-resolved reconstruction ( QSM ppm $$ {\mathrm{QSM}}_{\mathrm{ppm}} $$ = 0.31 × gadolinium mM + $$ \times {\mathrm{gadolinium}}_{\mathrm{mM}}+ $$ 0.05, R 2 $$ {R}^2 $$ = 0.999) and Cartesian without motion ( QSM ppm $$ {\mathrm{QSM}}_{\mathrm{ppm}} $$ = 0.32 × gadolinium mM + $$ \times {\mathrm{gadolinium}}_{\mathrm{mM}}+ $$ 0.04, R 2 $$ {R}^2 $$ = 1.000) showed linear relationships with gadolinium concentrations and showed good agreement with each other. For in vivo, motion-resolved reconstruction showed higher goodness of fit ( QSM ppm $$ {\mathrm{QSM}}_{\mathrm{ppm}} $$ = 0.00261 × R 2 s - 1 * - $$ \times {\mathrm{R}}_{2_{{\mathrm{s}}^{-1}}}^{\ast }- $$ 0.524, R 2 $$ {R}^2 $$ = 0.977) compared to motion-averaged reconstruction ( QSM ppm $$ {\mathrm{QSM}}_{\mathrm{ppm}} $$ = 0.0021 × R 2 s - 1 * - $$ \times {\mathrm{R}}_{2_{{\mathrm{s}}^{-1}}}^{\ast }- $$ 0.572, R 2 $$ {R}^2 $$ = 0.723) in ROI-based linear regression analysis between R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and QSM. CONCLUSION: Feasibility of free-breathing liver QSM was demonstrated with motion-resolved 3D multi-echo UTE cones MRI, achieving high isotropic resolution currently unachievable in conventional Cartesian MRI.


Asunto(s)
Gadolinio , Imagenología Tridimensional , Imagenología Tridimensional/métodos , Hígado/diagnóstico por imagen , Respiración , Frecuencia Respiratoria , Imagen por Resonancia Magnética/métodos
2.
Magn Reson Med ; 85(5): 2608-2621, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33432613

RESUMEN

PURPOSE: To enable motion-robust, ungated, free-breathing R2∗ mapping of hepatic iron overload in children with 3D multi-echo UTE cones MRI. METHODS: A golden-ratio re-ordered 3D multi-echo UTE cones acquisition was developed with chemical-shift encoding (CSE). Multi-echo complex-valued source images were reconstructed via gridding and coil combination, followed by confounder-corrected R2∗ (=1/ T2∗ ) mapping. A phantom containing 15 different concentrations of gadolinium solution (0-300 mM) was imaged at 3T. 3D multi-echo UTE cones with an initial TE of 0.036 ms and Cartesian CSE-MRI (IDEAL-IQ) sequences were performed. With institutional review board approval, 85 subjects (81 pediatric patients with iron overload + 4 healthy volunteers) were imaged at 3T using 3D multi-echo UTE cones with free breathing (FB cones), IDEAL-IQ with breath holding (BH Cartesian), and free breathing (FB Cartesian). Overall image quality of R2∗ maps was scored by 2 blinded experts and compared by a Wilcoxon rank-sum test. For each pediatric subject, the paired R2∗ maps were assessed to determine if a corresponding artifact-free 15 mm region-of-interest (ROI) could be identified at a mid-liver level on both images. Agreement between resulting R2∗ quantification from FB cones and BH/FB Cartesian was assessed with Bland-Altman and linear correlation analyses. RESULTS: ROI-based regression analysis showed a linear relationship between gadolinium concentration and R2∗ in IDEAL-IQ (y = 8.83x - 52.10, R2 = 0.995) as well as in cones (y = 9.19x - 64.16, R2 = 0.992). ROI-based Bland-Altman analysis showed that the mean difference (MD) was 0.15% and the SD was 5.78%. However, IDEAL-IQ R2∗ measurements beyond 200 mM substantially deviated from a linear relationship for IDEAL-IQ (y = 5.85x + 127.61, R2 = 0.827), as opposed to cones (y = 10.87x - 166.96, R2 = 0.984). In vivo, FB cones R2∗ had similar image quality with BH and FB Cartesian in 15 and 42 cases, respectively. FB cones R2∗ had better image quality scores than BH and FB Cartesian in 3 and 21 cases, respectively, where BH/FB Cartesian exhibited severe ghosting artifacts. ROI-based Bland-Altman analyses were 2.23% (MD) and 6.59% (SD) between FB cones and BH Cartesian and were 0.21% (MD) and 7.02% (SD) between FB cones and FB Cartesian, suggesting a good agreement between FB cones and BH (FB) Cartesian R2∗ . Strong linear relationships were observed between BH Cartesian and FB cones (y = 1.00x + 1.07, R2 = 0.996) and FB Cartesian and FB cones (y = 0.98x + 1.68, R2 = 0.999). CONCLUSION: Golden-ratio re-ordered 3D multi-echo UTE Cones MRI enabled motion-robust, ungated, and free-breathing R2∗ mapping of hepatic iron overload, with comparable R2∗ measurements and image quality to BH Cartesian, and better image quality than FB Cartesian.


Asunto(s)
Aumento de la Imagen , Sobrecarga de Hierro , Niño , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Sobrecarga de Hierro/diagnóstico por imagen , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Respiración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA