Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Magn Reson ; 26(1): 101042, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38556134

RESUMEN

BACKGROUND: Diastolic left ventricular (LV) dysfunction is a powerful contributor to the symptoms and prognosis of patients with heart failure. In patients with depressed LV systolic function, the E/A ratio, the ratio between the peak early (E) and the peak late (A) transmitral flow velocity, is the first step to defining the grade of diastolic dysfunction. Doppler echocardiography (echo) is the preferred imaging technique for diastolic function assessment, while cardiovascular magnetic resonance (CMR) is less established as a method. Previous four-dimensional (4D) Flow-based studies have looked at the E/A ratio proximal to the mitral valve, requiring manual interaction. In this study, we compare an automated, deep learning-based and two semi-automated approaches for 4D Flow CMR-based E/A ratio assessment to conventional, gold-standard echo-based methods. METHODS: Ninety-seven subjects with chronic ischemic heart disease underwent a cardiac echo followed by CMR investigation. 4D Flow-based E/A ratio values were computed using three different approaches; two semi-automated, assessing the E/A ratio by measuring the inflow velocity (MVvel) and the inflow volume (MVflow) at the mitral valve plane, and one fully automated, creating a full LV segmentation using a deep learning-based method with which the E/A ratio could be assessed without constraint to the mitral plane (LVvel). RESULTS: MVvel, MVflow, and LVvel E/A ratios were strongly associated with echocardiographically derived E/A ratio (R2 = 0.60, 0.58, 0.72). LVvel peak E and A showed moderate association to Echo peak E and A, while MVvel values were weakly associated. MVvel and MVflow EA ratios were very strongly associated with LVvel (R2 = 0.84, 0.86). MVvel peak E was moderately associated with LVvel, while peak A showed a strong association (R2 = 0.26, 0.57). CONCLUSION: Peak E, peak A, and E/A ratio are integral to the assessment of diastolic dysfunction and may expand the utility of CMR studies in patients with cardiovascular disease. While underestimation of absolute peak E and A velocities was noted, the E/A ratio measured with all three 4D Flow methods was strongly associated with the gold standard Doppler echocardiography. The automatic, deep learning-based method performed best, with the most favorable runtime of ∼40 seconds. As both semi-automatic methods associated very strongly to LVvel, they could be employed as an alternative for estimation of E/A ratio.


Asunto(s)
Automatización , Aprendizaje Profundo , Diástole , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas , Disfunción Ventricular Izquierda , Función Ventricular Izquierda , Humanos , Persona de Mediana Edad , Femenino , Masculino , Anciano , Reproducibilidad de los Resultados , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/diagnóstico por imagen , Enfermedad Crónica , Ecocardiografía Doppler , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología
2.
J Cardiovasc Magn Reson ; 26(2): 101070, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39096969

RESUMEN

BACKGROUND: Aortic wall shear stress (WSS) is a known predictor of ascending aortic growth in patients with a bicuspid aortic valve (BAV). The aim of this study was to study regional WSS and changes over time in BAV patients. METHODS: BAV patients and age-matched healthy controls underwent four-dimensional (4D) flow cardiovascular magnetic resonance (CMR). Regional, peak systolic ascending aortic WSS, aortic valve function, aortic stiffness measures, and aortic dimensions were assessed. In BAV patients, 4D flow CMR was repeated after 3 years of follow-up and both at baseline and follow-up computed tomography angiography (CTA) were acquired. Aortic growth (volume increase of ≥5%) was measured on CTA. Regional WSS differences within patients' aorta and WSS changes over time were analyzed using linear mixed-effect models and were associated with clinical parameters. RESULTS: Thirty BAV patients (aged 34 years [interquartile range (IQR) 25-41]) were included in the follow-up analysis. Additionally, another 16 BAV patients and 32 healthy controls (aged 33 years [IQR 28-48]) were included for other regional analyses. Magnitude, axial, and circumferential WSS increased over time (all p < 0.001) irrespective of aortic growth. The percentage of regions exposed to a magnitude WSS >95th percentile of healthy controls increased from 21% (baseline 506/2400 regions) to 31% (follow-up 734/2400 regions) (p < 0.001). WSS angle, a measure of helicity near the aortic wall, decreased during follow-up. Magnitude WSS changes over time were associated with systolic blood pressure, peak aortic valve velocity, aortic valve regurgitation fraction, aortic stiffness indexes, and normalized flow displacement (all p < 0.05). CONCLUSION: An increase in regional WSS over time was observed in BAV patients, irrespective of aortic growth. The increasing WSSs, comprising a larger area of the aorta, warrant further research to investigate the possible predictive value for aortic dissection.

3.
J Cardiovasc Magn Reson ; : 101088, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39214465

RESUMEN

OBJECTIVES: Patients with syndromic heritable thoracic aortic diseases (sHTAD) who underwent prophylactic aortic root replacement are at high risk of distal aortic events, but the underlying mechanisms are poorly understood. This prospective, longitudinal study aims to assess the impact of valve-sparing aortic root replacement (VSARR) on aortic fluid dynamics and biomechanics in these patients, and to examine whether they present altered haemodynamics or biomechanics prior to surgery compared to sHTAD patients with no indication for surgery (sHTAD-NSx) and healthy volunteers (HV). METHODS: Sixteen patients with Marfan or Loeys-Dietz syndrome underwent two 4D flow CMR studies before (sHTAD-preSx) and after VSARR (sHTAD-postSx). Two age, sex and BSA matched cohorts of 40 HV and 16 sHTAD-NSx patients with available 4D flow CMR, were selected for comparison. In-plane rotational flow (IRF), systolic flow reversal ratio (SFRR), wall shear stress (WSS), pulse wave velocity (PWV) and aortic strain were analysed in the ascending (AscAo) and descending aorta (DescAo). RESULTS: All patients with sHTAD presented altered haemodynamics and increased aortic stiffness (p<0.05) compared to HV, both in the AscAo (median PWV 7.4 in sHTAD-NSx; 6.8 in sHTAD-preSx; 4.9m/s in HV) and DescAo (median PWV 9.1 in sHTAD-NSx; 8.1 in sHTAD-preSx; 6.3m/s in HV). Patients awaiting VSARR had markedly reduced in-plane (median IRF -2.2 vs 10.4 cm2/s in HV, p=0.001), but increased through-plane flow rotation (median SFRR 7.8 vs 3.8% in HV, p=0.002), and decreased WSS (0.36 vs 0.47N/m2 in HV, p=0.004) in the proximal DescAo. After VSARR, proximal DescAo in-plane rotational flow (p=0.010) and circumferential WSS increased (p=0.011), no longer differing from HV, but through-plane rotational flow, axial WSS and stiffness remained altered. Patients in which aortic tortuosity was reduced after surgery showed greater post-surgical increase in IRF compared to those in which tortuosity increased (median IRF increase 18.1 vs 3.3cm²/s, p=0.047). Most AscAo flow alterations were restored to physiological values after VSARR. CONCLUSIONS: In patients with sHTAD, VSARR partially restores downstream fluid dynamics to physiological levels. However, some flow disturbances and increased stiffness persist in the proximal DescAo. Further longitudinal studies are needed to evaluate whether persistent alterations contribute to post-surgical risk.

4.
Pediatr Cardiol ; 45(5): 998-1006, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38519622

RESUMEN

We sought to evaluate the potential clinical role of 4D-flow cardiac magnetic resonance (CMR)-derived energetics and flow parameters in a cohort of patients' post-Fontan palliation. In patients with Fontan circulation who underwent 4D-Flow CMR, streamlines distribution was evaluated, as well a 4D-flow CMR-derived energetics parameters as kinetic energy (KE) and energy loss (EL) normalized by volume. EL/KE index as a marker of flow efficiency was also calculated. Cardiopulmonary exercise test (CPET) was also performed in a subgroup of patients. The population study included 55 patients (mean age 22 ± 11 years). The analysis of the streamlines revealed a preferential distribution of the right superior vena cava flow for the right pulmonary artery (62.5 ± 35.4%) and a mild preferential flow for the left pulmonary artery (52.3 ± 40.6%) of the inferior vena cave-pulmonary arteries (IVC-PA) conduit. Patients with heart failure (HF) presented lower IVC/PA-conduit flow (0.75 ± 0.5 vs 1.3 ± 0.5 l/min/m2, p = 0.004) and a higher mean flow-jet angle of the IVC-PA conduit (39.2 ± 22.8 vs 15.2 ± 8.9, p < 0.001) than the remaining patients. EL/KE index correlates inversely with VO2/kg/min: R: - 0.45, p = 0.01 peak, minute ventilation (VE) R: - 0.466, p < 0.01, maximal voluntary ventilation: R:0.44, p = 0.001 and positively with the physiological dead space to the tidal volume ratio (VD/VT) peak: R: 0.58, p < 0.01. From our data, lower blood flow in IVC/PA conduit and eccentric flow was associated with HF whereas higher EL/KE index was associated with reduced functional capacity and impaired lung function. Larger studies are needed to confirm our results and to further improve the prognostic role of the 4D-Flow CMR in this challenging population.


Asunto(s)
Prueba de Esfuerzo , Procedimiento de Fontan , Cardiopatías Congénitas , Arteria Pulmonar , Humanos , Femenino , Masculino , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/fisiopatología , Adulto Joven , Prueba de Esfuerzo/métodos , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Adolescente , Adulto , Imagen por Resonancia Cinemagnética/métodos , Niño , Vena Cava Superior/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Vena Cava Inferior/diagnóstico por imagen
5.
J Cardiovasc Magn Reson ; 25(1): 40, 2023 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-37474977

RESUMEN

Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.


Asunto(s)
Sistema Cardiovascular , Humanos , Velocidad del Flujo Sanguíneo , Valor Predictivo de las Pruebas , Corazón , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
6.
J Cardiovasc Magn Reson ; 25(1): 22, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36978131

RESUMEN

BACKGROUND: Different software programs are available for the evaluation of 4D Flow cardiovascular magnetic resonance (CMR). A good agreement of the results between programs is a prerequisite for the acceptance of the method. Therefore, the goal was to compare quantitative results from a cross-over comparison in individuals examined on two scanners of different vendors analyzed with four postprocessing software packages. METHODS: Eight healthy subjects (27 ± 3 years, 3 women) were each examined on two 3T CMR systems (Ingenia, Philips Healthcare; MAGNETOM Skyra, Siemens Healthineers) with a standardized 4D Flow CMR sequence. Six manually placed aortic contours were evaluated with Caas (Pie Medical Imaging, SW-A), cvi42 (Circle Cardiovascular Imaging, SW-B), GTFlow (GyroTools, SW-C), and MevisFlow (Fraunhofer Institute MEVIS, SW-D) to analyze seven clinically used parameters including stroke volume, peak flow, peak velocity, and area as well as typically scientifically used wall shear stress values. Statistical analysis of inter- and intrareader variability, inter-software and inter-scanner comparison included calculation of absolute and relative error (ER), intraclass correlation coefficient (ICC), Bland-Altman analysis, and equivalence testing based on the assumption that inter-software differences needed to be within 80% of the range of intrareader differences. RESULTS: SW-A and SW-C were the only software programs showing agreement for stroke volume (ICC = 0.96; ER = 3 ± 8%), peak flow (ICC: 0.97; ER = -1 ± 7%), and area (ICC = 0.81; ER = 2 ± 22%). Results from SW-A/D and SW-C/D were equivalent only for area and peak flow. Other software pairs did not yield equivalent results for routinely used clinical parameters. Especially peak maximum velocity yielded poor agreement (ICC ≤ 0.4) between all software packages except SW-A/D that showed good agreement (ICC = 0.80). Inter- and intrareader consistency for clinically used parameters was best for SW-A and SW-D (ICC = 0.56-97) and worst for SW-B (ICC = -0.01-0.71). Of note, inter-scanner differences per individual tended to be smaller than inter-software differences. CONCLUSIONS: Of all tested software programs, only SW-A and SW-C can be used equivalently for determination of stroke volume, peak flow, and vessel area. Irrespective of the applied software and scanner, high intra- and interreader variability for all parameters have to be taken into account before introducing 4D Flow CMR in clinical routine. Especially in multicenter clinical trials a single image evaluation software should be applied.


Asunto(s)
Imagen por Resonancia Magnética , Programas Informáticos , Humanos , Femenino , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Aorta
7.
BMC Cardiovasc Disord ; 23(1): 24, 2023 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-36647000

RESUMEN

BACKGROUND: Measurement of peak velocities is important in the evaluation of heart failure. This study compared the performance of automated 4D flow cardiac MRI (CMR) with traditional transthoracic Doppler echocardiography (TTE) for the measurement of mitral inflow peak diastolic velocities. METHODS: Patients with Doppler echocardiography and 4D flow cardiac magnetic resonance data were included retrospectively. An established automated technique was used to segment the left ventricular transvalvular flow using short-axis cine stack of images. Peak mitral E-wave and peak mitral A-wave velocities were automatically derived using in-plane velocity maps of transvalvular flow. Additionally, we checked the agreement between peak mitral E-wave velocity derived by 4D flow CMR and Doppler echocardiography in patients with sinus rhythm and atrial fibrillation (AF) separately. RESULTS: Forty-eight patients were included (median age 69 years, IQR 63 to 76; 46% female). Data were split into three groups according to heart rhythm. The median peak E-wave mitral inflow velocity by automated 4D flow CMR was comparable with Doppler echocardiography in all patients (0.90 ± 0.43 m/s vs 0.94 ± 0.48 m/s, P = 0.132), sinus rhythm-only group (0.88 ± 0.35 m/s vs 0.86 ± 0.38 m/s, P = 0.54) and in AF-only group (1.33 ± 0.56 m/s vs 1.18 ± 0.47 m/s, P = 0.06). Peak A-wave mitral inflow velocity results had no significant difference between Doppler TTE and automated 4D flow CMR (0.81 ± 0.44 m/s vs 0.81 ± 0.53 m/s, P = 0.09) in all patients and sinus rhythm-only groups. Automated 4D flow CMR showed a significant correlation with TTE for measurement of peak E-wave in all patients group (r = 0.73, P < 0.001) and peak A-wave velocities (r = 0.88, P < 0.001). Moreover, there was a significant correlation between automated 4D flow CMR and TTE for peak-E wave velocity in sinus rhythm-only patients (r = 0.68, P < 0.001) and AF-only patients (r = 0.81, P = 0.014). Excellent intra-and inter-observer variability was demonstrated for both parameters. CONCLUSION: Automated dynamic peak mitral inflow diastolic velocity tracing using 4D flow CMR is comparable to Doppler echocardiography and has excellent repeatability for clinical use. However, 4D flow CMR can potentially underestimate peak velocity in patients with AF.


Asunto(s)
Fibrilación Atrial , Válvula Mitral , Humanos , Femenino , Anciano , Masculino , Estudios Retrospectivos , Válvula Mitral/diagnóstico por imagen , Ecocardiografía Doppler/métodos , Imagen por Resonancia Magnética , Ecocardiografía , Fibrilación Atrial/diagnóstico por imagen , Velocidad del Flujo Sanguíneo
8.
J Cardiovasc Magn Reson ; 24(1): 20, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-35346239

RESUMEN

BACKGROUND: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. METHODS: Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. RESULTS: Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. CONCLUSIONS: In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Rigidez Vascular , Disección Aórtica/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso
9.
J Cardiovasc Magn Reson ; 24(1): 49, 2022 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-35989320

RESUMEN

BACKGROUND: Accurate evaluation of valvular pathology is crucial in the timing of surgical intervention. Whilst transthoracic echocardiography is widely available and routinely used in the assessment of valvular heart disease, it is bound by several limitations. Although cardiovascular magnetic resonance (CMR) imaging can overcome many of the challenges encountered by echocardiography, it also has a number of limitations. MAIN TEXT: 4D Flow CMR is a novel technique, which allows time-resolved, 3-dimensional imaging. It enables visualisation and direct quantification of flow and peak velocities of all valves simultaneously in one simple acquisition, without any geometric assumptions. It also has the unique ability to measure advanced haemodynamic parameters such as turbulent kinetic energy, viscous energy loss rate and wall shear stress, which may add further diagnostic and prognostic information. Although 4D Flow CMR acquisition can take 5-10 min, emerging acceleration techniques can significantly reduce scan times, making 4D Flow CMR applicable in contemporary clinical practice. CONCLUSION: 4D Flow CMR is an emerging CMR technique, which has the potential to become the new reference-standard method for the evaluation of valvular lesions. In this review, we describe the clinical applications, advantages and disadvantages of 4D Flow CMR in the assessment of valvular heart disease.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Imagen por Resonancia Magnética , Velocidad del Flujo Sanguíneo , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas
10.
J Cardiovasc Magn Reson ; 24(1): 61, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36451198

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) offers comprehensive right ventricular (RV) evaluation in pulmonary arterial hypertension (PAH). Emerging four-dimensional (4D) flow CMR allows visualization and quantification of intracardiac flow components and calculation of phasic blood kinetic energy (KE) parameters but it is unknown whether these parameters are associated with cardiopulmonary exercise test (CPET)-assessed exercise capacity, which is a surrogate measure of survival in PAH. We compared 4D flow CMR parameters in PAH with healthy controls, and investigated the association of these parameters with RV remodelling, RV functional and CPET outcomes. METHODS: PAH patients and healthy controls from two centers were prospectively enrolled to undergo on-site cine and 4D flow CMR, and CPET within one week. RV remodelling index was calculated as the ratio of RV to left ventricular (LV) end-diastolic volumes (EDV). Phasic (peak systolic, average systolic, and peak E-wave) LV and RV blood flow KE indexed to EDV (KEIEDV) and ventricular LV and RV flow components (direct flow, retained inflow, delayed ejection flow, and residual volume) were calculated. Oxygen uptake (VO2), carbon dioxide production (VCO2) and minute ventilation (VE) were measured and recorded. RESULTS: 45 PAH patients (46 ± 11 years; 7 M) and 51 healthy subjects (46 ± 14 years; 17 M) with no significant differences in age and gender were analyzed. Compared with healthy controls, PAH had significantly lower median RV direct flow, RV delayed ejection flow, RV peak E-wave KEIEDV, peak VO2, and percentage (%) predicted peak VO2, while significantly higher median RV residual volume and VE/VCO2 slope. RV direct flow and RV residual volume were significantly associated with RV remodelling, function, peak VO2, % predicted peak VO2 and VE/VCO2 slope (all P < 0.01). Multiple linear regression analyses showed RV direct flow to be an independent marker of RV function, remodelling and exercise capacity. CONCLUSION: In this 4D flow CMR and CPET study, RV direct flow provided incremental value over RVEF for discriminating adverse RV remodelling, impaired exercise capacity, and PAH with intermediate and high risk based on risk score. These data suggest that CMR with 4D flow CMR can provide comprehensive assessment of PAH severity, and may be used to monitor disease progression and therapeutic response. TRIAL REGISTRATION NUMBER: https://www. CLINICALTRIALS: gov . Unique identifier: NCT03217240.


Asunto(s)
Hipertensión Arterial Pulmonar , Humanos , Hipertensión Arterial Pulmonar/diagnóstico por imagen , Valor Predictivo de las Pruebas , Ventrículos Cardíacos , Biomarcadores , Remodelación Ventricular , Espectroscopía de Resonancia Magnética
11.
J Cardiovasc Magn Reson ; 24(1): 4, 2022 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-34980199

RESUMEN

BACKGROUND: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) allows quantification of biventricular blood flow by flow components and kinetic energy (KE) analyses. However, it remains unclear whether 4D flow parameters can predict cardiopulmonary exercise testing (CPET) as a clinical outcome in repaired tetralogy of Fallot (rTOF). Current study aimed to (1) compare 4D flow CMR parameters in rTOF with age- and gender-matched healthy controls, (2) investigate associations of 4D flow parameters with functional and volumetric right ventricular (RV) remodelling markers, and CPET outcome. METHODS: Sixty-three rTOF patients (14 paediatric, 49 adult; 30 ± 15 years; 29 M) and 63 age- and gender-matched healthy controls (14 paediatric, 49 adult; 31 ± 15 years) were prospectively recruited at four centers. All underwent cine and 4D flow CMR, and all adults performed standardized CPET same day or within one week of CMR. RV remodelling index was calculated as the ratio of RV to left ventricular (LV) end-diastolic volumes. Four flow components were analyzed: direct flow, retained inflow, delayed ejection flow and residual volume. Additionally, three phasic KE parameters normalized to end-diastolic volume (KEiEDV), were analyzed for both LV and RV: peak systolic, average systolic and peak E-wave. RESULTS: In comparisons of rTOF vs. healthy controls, median LV retained inflow (18% vs. 16%, P = 0.005) and median peak E-wave KEiEDV (34.9 µJ/ml vs. 29.2 µJ/ml, P = 0.006) were higher in rTOF; median RV direct flow was lower in rTOF (25% vs. 35%, P < 0.001); median RV delayed ejection flow (21% vs. 17%, P < 0.001) and residual volume (39% vs. 31%, P < 0.001) were both greater in rTOF. RV KEiEDV parameters were all higher in rTOF than healthy controls (all P < 0.001). On multivariate analysis, RV direct flow was an independent predictor of RV function and CPET outcome. RV direct flow and RV peak E-wave KEiEDV were independent predictors of RV remodelling index. CONCLUSIONS: In this multi-scanner multicenter 4D flow CMR study, reduced RV direct flow was independently associated with RV dysfunction, remodelling and, to a lesser extent, exercise intolerance in rTOF patients. This supports its utility as an imaging parameter for monitoring disease progression and therapeutic response in rTOF. Clinical Trial Registration https://www.clinicaltrials.gov . Unique identifier: NCT03217240.


Asunto(s)
Tetralogía de Fallot , Adulto , Niño , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Función Ventricular Derecha
12.
Echocardiography ; 39(6): 783-793, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35536700

RESUMEN

OBJECTIVES: To determine the 4D Flow Cardiac Magnetic Resonance (CMR) thresholds that achieve the best agreement with transthoracic echocardiography (TTE) for grading mitral regurgitation (MR). METHODS: We conducted a single-center prospective study of patients evaluated for chronic primary MR in 2016-2020. MR was evaluated blindly by TTE and 4D Flow CMR, respectively by two cardiologists and two radiologists with decades of experience. MR was graded with both methods as mild, moderate, or severe. 4D Flow CMR measurements included MR regurgitant volume per beat (RV) and mitral anterograde flow per beat (MF). RF was obtained as the ratio RV/MF. Additionally, MF was compared to left ventricular stroke volume (LVSV) by cine-CMR. RESULTS: We included 33 patients in the initial cohort and 33 in the validation cohort. Inter-observer agreement was excellent for 4D Flow CMR ICC = .94 (95% CI, .86-.97, p < 0.0001). Using recommended TTE thresholds (30 ml, 60 ml, 30%, 50%), agreement was moderate for RV and RF. The best agreement between 4D Flow CMR and TTE was obtained with CMR thresholds of 20 and 40 ml for RV (κ = .93; 95% CI, .8-1) and 20% and 37% for RF (κ = .90; 95% CI, .7-.9). In the validation cohort, agreement between TTE and 4D Flow CMR was good with the optimal thresholds (κ = .78; 95% CI, .61-.94). CONCLUSION: We propose CMR thresholds that provide a good agreement between TTE and CMR for grading MR. Further studies are needed to fully validate 4D-Flow CMR accuracy for primary MR quantification.


Asunto(s)
Insuficiencia de la Válvula Mitral , Ecocardiografía/métodos , Humanos , Imagen por Resonancia Cinemagnética/métodos , Espectroscopía de Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
13.
J Cardiovasc Magn Reson ; 23(1): 138, 2021 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-34865629

RESUMEN

BACKGROUND: Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet tracking in comparison to standard-of-care CMR indirect volumetric method. METHODS: This retrospective study included patients with HCM undergoing 4D flow CMR. By the indirect volumetric method from CMR, MR volume was quantified as left ventricular stroke volume minus forward aortic volume. By 4D flow CMR direct jet tracking, multiplanar reformatted planes were positioned in the peak velocity of the MR jet during systole to calculate through-plane regurgitant flow. MR severity was collected for agreement analysis from a clinical echocardiograms performed within 1 month of CMR. Inter-method and inter-observer agreement were assessed by intraclass correlation coefficient (ICC), Bland-Altman analysis, and Cohen's kappa. RESULTS: Thirty-seven patients with HCM were included. Direct jet tracking demonstrated good inter-method agreement of MR volume compared to the indirect volumetric method (ICC = 0.80, p = 0.004) and fair agreement of MR severity (kappa = 0.27, p = 0.03). Direct jet tracking showed higher agreement with echocardiography (kappa = 0.35, p = 0.04) than indirect volumetric method (kappa = 0.16, p = 0.35). Inter-observer reproducibility of indirect volumetric method components revealed the lowest reproducibility in end-systolic volume (ICC = 0.69, p = 0.15). Indirect volumetric method showed good agreement of MR volume (ICC = 0.80, p = 0.003) and fair agreement of MR severity (kappa = 0.38, p < 0.001). Direct jet tracking demonstrated (1) excellent inter-observer reproducibility of MR volume (ICC = 0.97, p < 0.001) and MR severity (kappa = 0.84, p < 0.001) and (2) excellent intra-observer reproducibility of MR volume (ICC = 0.98, p < 0.001) and MR severity (kappa = 0.88, p < 0.001). CONCLUSIONS: Quantifying MR and assessing MR severity by indirect volumetric method in HCM patients has limited inter-observer reproducibility. 4D flow CMR jet tracking is a potential alternative technique to directly quantify and assess MR severity with excellent inter- and intra-observer reproducibility and higher agreement with echocardiography in this population.


Asunto(s)
Cardiomiopatía Hipertrófica , Insuficiencia de la Válvula Mitral , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Humanos , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
14.
J Cardiovasc Magn Reson ; 21(1): 43, 2019 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-31340834

RESUMEN

BACKGROUND: We hypothesize that dobutamine-induced stress impacts intracardiac hemodynamic parameters and that this may be linked to decreased exercise capacity in Fontan patients. Therefore, the purpose of this study was to assess the effect of pharmacologic stress on intraventricular kinetic energy (KE), viscous energy loss (EL) and vorticity from four-dimensional (4D) Flow cardiovascular magnetic resonance (CMR) imaging in Fontan patients and to study the association between stress response and exercise capacity. METHODS: Ten Fontan patients underwent whole-heart 4D flow CMR before and during 7.5 µg/kg/min dobutamine infusion and cardiopulmonary exercise testing (CPET) on the same day. Average ventricular KE, EL and vorticity were computed over systole, diastole and the total cardiac cycle (vorticity_volavg cycle, KEavg cycle, ELavg cycle). The relation to maximum oxygen uptake (VO2 max) from CPET was tested by Pearson's correlation or Spearman's rank correlation in case of non-normality of the data. RESULTS: Dobutamine stress caused a significant 88 ± 52% increase in KE (KEavg cycle: 1.8 ± 0.5 vs 3.3 ± 0.9 mJ, P < 0.001), a significant 108 ± 49% increase in EL (ELavg cycle: 0.9 ± 0.4 vs 1.9 ± 0.9 mW, P < 0.001) and a significant 27 ± 19% increase in vorticity (vorticity_volavg cycle: 3441 ± 899 vs 4394 ± 1322 mL/s, P = 0.002). All rest-stress differences (%) were negatively correlated to VO2 max (KEavg cycle: r = - 0.83, P = 0.003; ELavg cycle: r = - 0.80, P = 0.006; vorticity_volavg cycle: r = - 0.64, P = 0.047). CONCLUSIONS: 4D flow CMR-derived intraventricular kinetic energy, viscous energy loss and vorticity in Fontan patients increase during pharmacologic stress and show a negative correlation with exercise capacity measured by VO2 max.


Asunto(s)
Agonistas de Receptores Adrenérgicos beta 1/administración & dosificación , Circulación Coronaria/efectos de los fármacos , Dobutamina/administración & dosificación , Prueba de Esfuerzo , Tolerancia al Ejercicio/efectos de los fármacos , Procedimiento de Fontan , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Hemodinámica/efectos de los fármacos , Imagen por Resonancia Cinemagnética , Imagen de Perfusión Miocárdica/métodos , Consumo de Oxígeno/efectos de los fármacos , Adolescente , Femenino , Cardiopatías Congénitas/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
15.
J Cardiovasc Magn Reson ; 21(1): 65, 2019 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-31638997

RESUMEN

BACKGROUND: Three-dimensional time-resolved phase-contrast cardiovascular magnetic resonance (4D flow CMR) enables the quantification and visualisation of blood flow, but its clinical applicability remains hampered by its long scan time. The aim of this study was to evaluate the use of compressed sensing (CS) with on-line reconstruction to accelerate the acquisition and reconstruction of 4D flow CMR of the thoracic aorta. METHODS: 4D flow CMR of the thoracic aorta was acquired in 20 healthy subjects using CS with acceleration factors ranging from 4 to 10. As a reference, conventional parallel imaging (SENSE) with acceleration factor 2 was used. Flow curves, net flows, peak flows and peak velocities were extracted from six contours along the aorta. To measure internal data consistency, a quantitative particle trace analysis was performed. Additionally, scan-rescan, inter- and intraobserver reproducibility were assessed. Subsequently, 4D flow CMR with CS factor 6 was acquired in 3 patients with differing aortopathies. The flow patterns resulting from particle trace visualisation were qualitatively analysed. RESULTS: All collected data were successfully acquired and reconstructed on-line. The average acquisition time including respiratory navigator efficiency with CS factor 6 was 5:02 ± 2:23 min while reconstruction took approximately 9 min. For CS factors of 8 or less, mean differences in net flow, peak flow and peak velocity as compared to SENSE were below 2.2 ± 7.8 ml/cycle, 4.6 ± 25.2 ml/s and - 7.9 ± 13.0 cm/s, respectively. For a CS factor of 10 differences reached 5.4 ± 8.0 ml/cycle, 14.4 ± 28.3 ml/s and - 4.0 ± 12.2 cm/s. Scan-rescan analysis yielded mean differences in net flow of - 0.7 ± 4.9 ml/cycle for SENSE and - 0.2 ± 8.5 ml/cycle for CS factor of 6. CONCLUSIONS: A six- to eightfold acceleration of 4D flow CMR using CS is feasible. Up to a CS acceleration rate of 6, no statistically significant differences in measured flow parameters could be observed with respect to the reference technique. Acquisitions in patients with aortopathies confirm the potential to integrate the proposed method in a clinical routine setting, whereby its main benefits are scan-time savings and direct on-line reconstruction.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Hemodinámica , Angiografía por Resonancia Magnética , Imagen de Perfusión/métodos , Adulto , Aorta Torácica/fisiopatología , Enfermedades de la Aorta/fisiopatología , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Estudios de Factibilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Factores de Tiempo , Adulto Joven
16.
J Cardiovasc Magn Reson ; 21(1): 75, 2019 12 12.
Artículo en Inglés | MEDLINE | ID: mdl-31829235

RESUMEN

BACKGROUND: Arterial pulse wave velocity (PWV) is associated with increased mortality in aging and disease. Several studies have shown the accuracy of applanation tonometry carotid-femoral PWV (Cf-PWV) and the relevance of evaluating central aorta stiffness using 2D cardiovascular magnetic resonance (CMR) to estimate PWV, and aortic distensibility-derived PWV through the theoretical Bramwell-Hill model (BH-PWV). Our aim was to compare various methods of aortic PWV (aoPWV) estimation from 4D flow CMR, in terms of associations with age, Cf-PWV, BH-PWV and left ventricular (LV) mass-to-volume ratio while evaluating inter-observer reproducibility and robustness to temporal resolution. METHODS: We studied 47 healthy subjects (49.5 ± 18 years) who underwent Cf-PWV and CMR including aortic 4D flow CMR as well as 2D cine SSFP for BH-PWV and LV mass-to-volume ratio estimation. The aorta was semi-automatically segmented from 4D flow data, and mean velocity waveforms were estimated in 25 planes perpendicular to the aortic centerline. 4D flow CMR aoPWV was calculated: using velocity curves at two locations, namely ascending aorta (AAo) and distal descending aorta (DAo) aorta (S1, 2D-like strategy), or using all velocity curves along the entire aortic centreline (3D-like strategies) with iterative transit time (TT) estimates (S2) or a plane fitting of velocity curves systolic upslope (S3). For S1 and S2, TT was calculated using three approaches: cross-correlation (TTc), wavelets (TTw) and Fourier transforms (TTf). Intra-class correlation coefficients (ICC) and Bland-Altman biases (BA) were used to evaluate inter-observer reproducibility and effect of lower temporal resolution. RESULTS: 4D flow CMR aoPWV estimates were significantly (p < 0.05) correlated to the CMR-independent Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with the strongest correlations for the 3D-like strategy using wavelets TT (S2-TTw) (R = 0.62, 0.65, 0.77 and 0.52, respectively, all p < 0.001). S2-TTw was also highly reproducible (ICC = 0.99, BA = 0.09 m/s) and robust to lower temporal resolution (ICC = 0.97, BA = 0.15 m/s). CONCLUSIONS: Reproducible 4D flow CMR aoPWV estimates can be obtained using full 3D aortic coverage. Such 4D flow CMR stiffness measures were significantly associated with Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with a slight superiority of the 3D strategy using wavelets transit time (S2-TTw).


Asunto(s)
Aorta/diagnóstico por imagen , Angiografía por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Análisis de la Onda del Pulso , Rigidez Vascular , Adulto , Factores de Edad , Anciano , Aorta/fisiología , Velocidad del Flujo Sanguíneo , Femenino , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo
17.
J Cardiovasc Magn Reson ; 21(1): 8, 2019 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-30661506

RESUMEN

BACKGROUND: To date it has not been possible to obtain a comprehensive 3D assessment of fetal hemodynamics because of the technical challenges inherent in imaging small cardiac structures, movement of the fetus during data acquisition, and the difficulty of fusing data from multiple cardiac cycles when a cardiac gating signal is absent. Here we propose the combination of volumetric velocity-sensitive cardiovascular magnetic resonance imaging ("4D flow" CMR) and a specialized animal preparation (catheters to monitor fetal heart rate, anesthesia to immobilize mother and fetus) to examine fetal sheep cardiac hemodynamics in utero. METHODS: Ten pregnant Merino sheep underwent surgery to implant arterial catheters in the target fetuses. Anesthetized ewes underwent 4D flow CMR with acquisition at 3 T for fetal whole-heart coverage with 1.2-1.5 mm spatial resolution and 45-62 ms temporal resolution. Flow was measured in the heart and major vessels, and particle traces were used to visualize circulatory patterns in fetal cardiovascular shunts. Conservation of mass was used to test internal 4D flow consistency, and comparison to standard 2D phase contrast (PC) CMR was performed for validation. RESULTS: Streaming of blood from the ductus venosus through the foramen ovale was visualized. Flow waveforms in the major thoracic vessels and shunts displayed normal arterial and venous patterns. Combined ventricular output (CVO) was 546 mL/min per kg, and the distribution of flows (%CVO) were comparable to values obtained using other methods. Internal 4D flow consistency across 23 measurement locations was established with differences of 14.2 ± 12.1%. Compared with 2D PC CMR, 4D flow showed a strong correlation (R2 = 0.85) but underestimated flow (bias = - 21.88 mL/min per kg, p < 0.05). CONCLUSIONS: The combination of fetal surgical preparation and 4D flow CMR enables characterization and quantification of complex flow patterns in utero. Visualized streaming of blood through normal physiological shunts confirms the complex mechanism of substrate delivery to the fetal heart and brain. Besides offering insight into normal physiology, this technology has the potential to qualitatively characterize complex flow patterns in congenital heart disease phenotypes in a large animal model, which can support the development of new interventions to improve outcomes in this population.


Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Vasos Sanguíneos/fisiología , Circulación Coronaria , Corazón Fetal/diagnóstico por imagen , Hemodinámica , Imagen por Resonancia Magnética , Imagen de Perfusión Miocárdica/métodos , Diagnóstico Prenatal/métodos , Animales , Velocidad del Flujo Sanguíneo , Vasos Sanguíneos/embriología , Femenino , Corazón Fetal/fisiología , Edad Gestacional , Frecuencia Cardíaca Fetal , Valor Predictivo de las Pruebas , Embarazo , Oveja Doméstica
18.
J Cardiovasc Magn Reson ; 21(1): 63, 2019 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-31607265

RESUMEN

BACKGROUND: Diseases of the descending aorta have emerged as a clinical issue in Marfan syndrome following improvements in proximal aorta surgical treatment and the consequent increase in life expectancy. Although a role for hemodynamic alterations in the etiology of descending aorta disease in Marfan patients has been suggested, whether flow characteristics may be useful as early markers remains to be determined. METHODS: Seventy-five Marfan patients and 48 healthy subjects were prospectively enrolled. In- and through-plane vortexes were computed by 4D flow cardiovascular magnetic resonance (CMR) in the thoracic aorta through the quantification of in-plane rotational flow and systolic flow reversal ratio, respectively. Regional pulse wave velocity and axial and circumferential wall shear stress maps were also computed. RESULTS: In-plane rotational flow and circumferential wall shear stress were reduced in Marfan patients in the distal ascending aorta and in proximal descending aorta, even in the 20 patients free of aortic dilation. Multivariate analysis showed reduced in-plane rotational flow to be independently related to descending aorta pulse wave velocity. Conversely, systolic flow reversal ratio and axial wall shear stress were altered in unselected Marfan patients but not in the subgroup without dilation. In multivariate regression analysis proximal descending aorta axial (p = 0.014) and circumferential (p = 0.034) wall shear stress were independently related to local diameter. CONCLUSIONS: Reduced rotational flow is present in the aorta of Marfan patients even in the absence of dilation, is related to aortic stiffness and drives abnormal circumferential wall shear stress. Axial and circumferential wall shear stress are independently related to proximal descending aorta dilation beyond clinical factors. In-plane rotational flow and circumferential wall shear stress may be considered as an early marker of descending aorta dilation in Marfan patients.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Hemodinámica , Angiografía por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Síndrome de Marfan/complicaciones , Imagen de Perfusión/métodos , Adulto , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/fisiopatología , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Dilatación Patológica , Femenino , Humanos , Masculino , Síndrome de Marfan/diagnóstico , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Flujo Sanguíneo Regional , Estrés Mecánico , Rigidez Vascular , Adulto Joven
19.
J Cardiovasc Magn Reson ; 20(1): 61, 2018 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-30165869

RESUMEN

BACKGROUND: Myocardial infarction (MI) leads to complex changes in left ventricular (LV) haemodynamics that are linked to clinical outcomes. We hypothesize that LV blood flow kinetic energy (KE) is altered in MI and is associated with LV function and infarct characteristics. This study aimed to investigate the intra-cavity LV blood flow KE in controls and MI patients, using cardiovascular magnetic resonance (CMR) four-dimensional (4D) flow assessment. METHODS: Forty-eight patients with MI (acute-22; chronic-26) and 20 age/gender-matched healthy controls underwent CMR which included cines and whole-heart 4D flow. Patients also received late gadolinium enhancement imaging for infarct assessment. LV blood flow KE parameters were indexed to LV end-diastolic volume and include: averaged LV, minimal, systolic, diastolic, peak E-wave and peak A-wave KEiEDV. In addition, we investigated the in-plane proportion of LV KE (%) and the time difference (TD) to peak E-wave KE propagation from base to mid-ventricle was computed. Association of LV blood flow KE parameters to LV function and infarct size were investigated in all groups. RESULTS: LV KEiEDV was higher in controls than in MI patients (8.5 ± 3 µJ/ml versus 6.5 ± 3 µJ/ml, P = 0.02). Additionally, systolic, minimal and diastolic peak E-wave KEiEDV were lower in MI (P < 0.05). In logistic-regression analysis, systolic KEiEDV (Beta = - 0.24, P < 0.01) demonstrated the strongest association with the presence of MI. In multiple-regression analysis, infarct size was most strongly associated with in-plane KE (r = 0.5, Beta = 1.1, P < 0.01). In patients with preserved LV ejection fraction (EF), minimal and in-plane KEiEDV were reduced (P < 0.05) and time difference to peak E-wave KE propagation during diastole increased (P < 0.05) when compared to controls with normal EF. CONCLUSIONS: Reduction in LV systolic function results in reduction in systolic flow KEiEDV. Infarct size is independently associated with the proportion of in-plane LV KE. Degree of LV impairment is associated with TD of peak E-wave KE. In patient with preserved EF post MI, LV blood flow KE mapping demonstrated significant changes in the in-plane KE, the minimal KEiEDV and the TD. These three blood flow KE parameters may offer novel methods to identify and describe this patient population.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Imagen de Perfusión Miocárdica/métodos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Adulto , Anciano , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Medios de Contraste/administración & dosificación , Circulación Coronaria , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Infarto del Miocardio con Elevación del ST/patología , Infarto del Miocardio con Elevación del ST/fisiopatología , Función Ventricular Izquierda
20.
J Cardiovasc Magn Reson ; 20(1): 28, 2018 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-29695249

RESUMEN

BACKGROUND: In patients with bicuspid valve (BAV), ascending aorta (AAo) dilatation may be caused by altered flow patterns and wall shear stress (WSS). These differences may explain different aortic dilatation morphotypes. Using 4D-flow cardiovascular magnetic resonance (CMR), we aimed to analyze differences in flow patterns and regional axial and circumferential WSS maps between BAV phenotypes and their correlation with ascending aorta dilatation morphotype. METHODS: One hundred and one BAV patients (aortic diameter ≤ 45 mm, no severe valvular disease) and 20 healthy subjects were studied by 4D-flow CMR. Peak velocity, flow jet angle, flow displacement, in-plane rotational flow (IRF) and systolic flow reversal ratio (SFRR) were assessed at different levels of the AAo. Peak-systolic axial and circumferential regional WSS maps were also estimated. Unadjusted and multivariable adjusted linear regression analyses were used to identify independent correlates of aortic root or ascending dilatation. Age, sex, valve morphotype, body surface area, flow derived variables and WSS components were included in the multivariable models. RESULTS: The AAo was non-dilated in 24 BAV patients and dilated in 77 (root morphotype in 11 and ascending in 66). BAV phenotype was right-left (RL-) in 78 patients and right-non-coronary (RN-) in 23. Both BAV phenotypes presented different outflow jet direction and velocity profiles that matched the location of maximum systolic axial WSS. RL-BAV velocity profiles and maximum axial WSS were homogeneously distributed right-anteriorly, however, RN-BAV showed higher variable profiles with a main proximal-posterior distribution shifting anteriorly at mid-distal AAo. Compared to controls, BAV patients presented similar WSS magnitude at proximal, mid and distal AAo (p = 0.764, 0.516 and 0.053, respectively) but lower axial and higher circumferential WSS components (p < 0.001 for both, at all aortic levels). Among BAV patients, RN-BAV presented higher IRF at all levels (p = 0.024 proximal, 0.046 mid and 0.002 distal AAo) and higher circumferential WSS at mid and distal AAo (p = 0.038 and 0.046, respectively) than RL-BAV. However, axial WSS was higher in RL-BAV compared to RN-BAV at proximal and mid AAo (p = 0.046, 0.019, respectively). Displacement and axial WSS were independently associated with the root-morphotype, and circumferential WSS and SFRR with the ascending-morphotype. CONCLUSIONS: Different BAV-phenotypes present different flow patterns with an anterior distribution in RL-BAV, whereas, RN-BAV patients present a predominant posterior outflow jet at the sinotubular junction that shifts to anterior or right anterior in mid and distal AAo. Thus, RL-BAV patients present a higher axial WSS at the aortic root while RN-BAV present a higher circumferential WSS in mid and distal AAo. These results may explain different AAo dilatation morphotypes in the BAV population.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Imagen de Perfusión Miocárdica/métodos , Adulto , Anciano , Aorta Torácica/patología , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Estudios de Casos y Controles , Dilatación Patológica , Femenino , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Fenotipo , Valor Predictivo de las Pruebas , Estudios Prospectivos , Flujo Sanguíneo Regional , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA