J Surg Res ; 296: 1-9, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38181643

RESUMEN

INTRODUCTION: Adrenal venous sampling (AVS) is used to distinguish unilateral from bilateral aldosterone hypersecretion as a cause of primary aldosteronism (PA). Unilateral disease is treated with adrenalectomy and bilateral hypersecretion managed medically. METHODS: We performed a single institution retrospective cohort study of adult patients undergoing adrenalectomy for PA from July 2013 to June 2022. Concordance of imaging findings with AVS was evaluated. Statistical analysis was performed with Mann-Whitney U and chi-squared Fisher's exact. Literature review performed via triple method search strategy. RESULTS: Twenty-one patients underwent AVS and adrenalectomy for PA. Two patients did not have imaging findings and 19 were localized with an adenoma. For patients with image localization, AVS was concordant in nine, discordant in four, and nondiagnostic in six. For patients with discordant findings, age range was 35.8 to 72.4 y compared with concordant patient age range of 49.8 to 71.7 y. Overall discordance between imaging results and AVS was 40%. The aldosterone level was associated with concordance with a median of 52 ng/dL compared with 26 ng/dL if discordant (P = 0.002). There was a significant reduction in antihypertensive medications for the entire cohort from a median of three medications (interquartile range 2-4) to 1 medication (interquartile range 1-2), P < 0.001. CONCLUSIONS: In this cohort, 40% of patients with selective AVS had discordant imaging and AVS results. Aldosterone level was associated with concordance. Hypertension was significantly improved with a median decrease of two antihypertensives. Our results support performance of AVS on all candidates for adrenalectomy for PA.


Asunto(s)
Glándulas Suprarrenales , Hiperaldosteronismo , Adulto , Humanos , Glándulas Suprarrenales/diagnóstico por imagen , Glándulas Suprarrenales/irrigación sanguínea , Aldosterona , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/etiología , Hiperaldosteronismo/cirugía , Estudios de Cohortes , Estudios Retrospectivos , Adrenalectomía/efectos adversos , Tomografía Computarizada por Rayos X/efectos adversos
2.
Front Endocrinol (Lausanne) ; 13: 859347, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35388294

RESUMEN

Since April 2021, the plasma aldosterone concentration has been measured by chemiluminescent enzyme immunoassay (CLEIA) in Japan. In the present study, we developed a new CLEIA using a two-step sandwich method to measure the 24-hour urine aldosterone level. We collected 115 urine samples and measured 24-hour urine aldosterone levels employing radioimmunoassay (RIA), CLEIA, and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The results showed that the 24-hour urine aldosterone levels measured using CLEIA and LC-MS/MS were significantly correlated (ρ = 0.992, P < 0.0001). Based on the results of Passing-Bablok regression analysis, the slope was 0.992 and the intercept -19.3. The 24-hour urine aldosterone levels measured using CLEIA and RIA were also significantly correlated (ρ = 0.905, P < 0.0001). However, the aldosterone level measured by CLEIA was lower than that measured by RIA (slope, 0.729; intercept, 120.9). In Japan, a new guideline for primary aldosteronism has been announced, with changes in the aldosterone measurement method. The cutoff values for oral sodium loading test (OSLT) were changed, but clinical verification using real-world urine samples has not been performed. Therefore, we examined the cut-off value of the 24-hour urine aldosterone level after the OSLT. Receiver operating characteristic analysis revealed a cut-off value for primary aldosteronism of 3 µg/day.


Asunto(s)
Aldosterona , Hiperaldosteronismo , Cromatografía Liquida , Humanos , Técnicas para Inmunoenzimas , Cloruro de Sodio , Espectrometría de Masas en Tándem/métodos