Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Pulm Med ; 22(1): 112, 2022 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-35351079

RESUMEN

PURPOSE: This study aims to evaluate the diagnostic application and performance of the metagenomic next-generation sequencing (mNGS) in patients suspected of local pulmonary infection by comparing it to the traditional pathogen detection methods in lung tissue specimens obtained by a computerized tomography-guided biopsy (CT-guided biopsy). METHODS: We retrospectively reviewed patients, admitted to the First Affiliated Hospital of Wenzhou Medical University, China from May 2018 to December 2020, who were suspected of local pulmonary infection. All cases received a CT-guided lung biopsy, tissue samples were sent both for conventional examinations (CE) and mNGS tests. The sensitivity and specificity of the two diagnostic approaches were compared. RESULTS: 106 patients enrolled, 76 patients were diagnosed with a pulmonary infection. Among 49 patients with identified pathogens, CE confirmed pathogenic infections in 32 cases. Mycobacterium spp. and fungi accounted for 37.5% (12/32) and 28.1% (9/32), respectively, with bacteria 34.4% (11/32). The mNGS examination detected extra pathogenic microorganisms in 22 patients that were consistent with the patients' clinical and radiographic pictures. The sensitivity of mNGS was 53.9% vs. 42.1% for the CE, while the specificity was 56.7% versus 96.7%. For detection rate, mNGS was significantly superior to CE in bacterial (96.3% vs. 40.7%, p < 0.05), and mixed infections (100% vs. 50%, p < 0.05), but inferior to CE in fungal (60% vs. 90%, p > 0.05) and Mycobacterium spp. infections (66.7% vs. 100%, p > 0.05) with no significant difference. Among 31 cases diagnosed with lung abscess, the diagnostic performance of the detection rate was 67.7% (21/31) in favour of mNGS compared to 29.0% (9/31) for CE (p < 0.05). Most polymicrobial infections were induced by anaerobic species that coexisted with Streptococcus constellatus. And Klebsiella pneumoniae was the most common isolated monomicrobial infection. CONCLUSIONS: The most commonly detected causative pathogens for local pulmonary infections were bacteria, Mycobacterium spp. and fungi. Compared with the CE, the advantages of mNGS in the pathogens detection lie in the discovery of bacterial and mixed infections, as well as in the detection of lung abscess. Conversely, mNGS is not good enough to be recommendable for the detection of Mycobacterium spp. and fungi.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento , Metagenómica , Biopsia , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Pulmón/diagnóstico por imagen , Metagenómica/métodos , Estudios Retrospectivos
2.
Future Oncol ; 15(10): 1125-1134, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30880466

RESUMEN

Computed tomography-guided lung biopsy is a valid and safe procedure for characterizing pulmonary nodules. In the past years, this technique has been mainly used to confirm the malignant nature of undetermined pulmonary lesions; however, today its role has been completely renewed. With the advent of target therapy and immunotherapy, it has arisen for lung cancer, in inoperable patients, the necessity to obtain adequate bioptical material to perform a correct molecular characterization of the lesion. Moreover, the possibility of acquired drug-resistance mechanisms makes it necessary in some cases to rebiopsy these lesions over time. For these reasons, it is likely that the request of computed tomography-guided lung biopsy will increase in the future, therefore every radiologist should be confident with its most important aspects.


Asunto(s)
Biopsia Guiada por Imagen/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirugía , Medicina de Precisión , Tórax/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Pronóstico
3.
AJR Am J Roentgenol ; 204(1): 29-34, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25539234

RESUMEN

OBJECTIVE: CT-guided lung biopsy is a well-established diagnostic method for pulmonary lesions. The aim of our study was to evaluate the diagnostic outcomes and safety profile of conventional CT-guided lung biopsies. MATERIALS AND METHODS: We retrospectively analyzed the results of CT-guided lung biopsies for 750 patients to determine the diagnostic accuracy, complication rates, and independent risk factors for diagnostic failure and severe pneumothorax. RESULTS: Diagnostic accuracy was 92.9%. Independent risk factors for diagnostic failure were malignant lesions (odds ratio [OR], 4.20; 95% CI, 1.66-14.1; p = 0.001), lesions in the lower lobe (OR, 2.01; 95% CI, 1.17-3.47; p = 0.011), lesions 2.0 cm or smaller (OR, 2.87; 95% CI, 1.59-5.48; p < 0.001), and the presence of pneumothorax during the procedure (OR, 2.18; 95% CI, 1.27-3.78; p = 0.004). Pneumothorax requiring drainage occurred in 7% of patients. Independent risk factors for pneumothorax requiring drainage were age of 73 years or older (OR, 2.19; 95% CI, 1.21-4.05; p = 0.009), the presence of emphysema (OR, 4.29; 95% CI, 2.05-8.82; p < 0.001), benign lesions (OR, 2.33; 95% CI, 1.20-4.40; p = 0.012), supine positioning of the patient (OR, 2.61; 95% CI, 1.44-4.84; p = 0.001), and length from the pleura to the lesion of 1.5 cm or greater (OR, 3.08; 95% CI, 1.63-6.17; p < 0.001). CONCLUSION: CT-guided lung biopsy has a high diagnostic accuracy. Complication rates were acceptable and comparable to those of previous studies.


Asunto(s)
Biopsia con Aguja Fina/estadística & datos numéricos , Biopsia con Aguja Gruesa/estadística & datos numéricos , Neoplasias Pulmonares/epidemiología , Neoplasias Pulmonares/patología , Neumotórax/epidemiología , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adulto , Anciano , Comorbilidad , Femenino , Humanos , Biopsia Guiada por Imagen , Japón/epidemiología , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Prevalencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Radiol Case Rep ; 19(4): 1239-1242, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38292794

RESUMEN

Air emboli represent rare but severe complications of computed tomography (CT)-guided lung biopsy (CTLB). No reports exist regarding the behavior of air during the early stages of air emboli. We present a case of air emboli following CTLB, evaluated by intermittent CT over a 2-hour period, spanning from onset to resolution. A man in his 60s underwent CTLB for diagnosis of a slowly enlarging pulmonary nodule in the right lower lobe. Immediately post-biopsy, chest CT revealed air emboli in the right coronary artery and apex of the ascending aorta. The patient was in the head-down position on the CT table, and intermittent CT scans were performed over a 2-hour period until the air emboli resolved. Subsequently, the patient was discharged without any complications.

5.
Heliyon ; 10(6): e27914, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38509877

RESUMEN

Systemic air embolism is a fatal complication of computed tomography-guided percutaneous lung biopsy. Here, we report a case of acute coronary artery air embolism following computed tomography (CT) guided percutaneous lung biopsy. The patient exhibited cardiac symptoms, and CT showed air density in left ventricle and aorta, indicating air embolism. Trendelenburg positioning and coronary angiography were performed during the treatment, and the patient was discharged without obvious complications.

6.
Diagnostics (Basel) ; 13(23)2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38066786

RESUMEN

This study aimed to assess the effectiveness of saline sealing in reducing the incidence of pneumothorax after a CT-guided lung biopsy. This was a retrospective case-control study of patients who underwent CT-guided biopsies for lung tumors using 18 G semiautomatic core needles in conjunction with 17 G coaxial needles. The patients were divided into two consecutive groups: a historical Group A (n = 111), who did not receive saline sealing, and Group B (n = 87), who received saline sealing. In Group B, NaCl 0.9% was injected through the coaxial needle upon its removal. The incidence of pneumothorax and chest tube insertion was compared between the two groups. Multivariate logistic regression was performed to verify the contribution of other pneumothorax risk factors. The study included 198 patients, with 111 in Group A and 87 in Group B. There was a significantly (p = 0.02) higher pneumothorax rate in Group A (35.1%, n = 39) compared to Group B (20.7%, n = 18). The difference regarding chest tube insertion was not significant (p = 0.1), despite a tendency towards more insertions in Group A (5.4%, n = 6), compared to Group B (1.1%, n = 1). Among the risk factors for pneumothorax, only the presence of emphysema (OR = 3.5, p = 0.0007) and belonging to Group A (OR = 2.2, p = 0.02) were significant. Saline sealing of the needle tract after a CT-guided lung biopsy can significantly reduce the incidence of pneumothorax. This technique is safe, readily available, and inexpensive, and should be considered as a routine preventive measure during this procedure.

7.
Zhongguo Fei Ai Za Zhi ; 26(8): 572-578, 2023 Aug 20.
Artículo en Zh | MEDLINE | ID: mdl-37752537

RESUMEN

BACKGROUND: Rapid on-site evaluation (ROSE) is a technique used for simultaneous evaluation of biopsy specimens through rapid cytology staining. Diff-Quik (DQ) staining is the most commonly employed method for cytological rapid on-site evaluation (C-ROSE). However, the utilization of DQ staining for on-site cytological interpretation remains uncommon among pathologists in China, posing challenges to the implementation of C-ROSE. This study aims to assess the application of rapid hematoxylin-eosin (HE) staining and DQ staining for C-ROSE during percutaneous needle biopsy of peripheral lung cancer and evaluate the value of rapid HE staining in C-ROSE. METHODS: Computed tomography (CT)-guided lung biopsies were conducted on 300 patients diagnosed with peripheral lung cancer. The patients were randomly assigned to two groups for C-ROSE using either rapid HE staining or DQ staining, and subsequently the two methods were compared and evaluated. RESULTS: The concordance rate between C-ROSE and histopathological diagnosis was 96.7%. The median staining time for rapid HE staining was 160 s, while that for DQ staining was 120 s, representing a significant difference between the two groups (P<0.001). However, there were no significant differences observed in terms of total biopsy time, concordance rate with histopathology, cytology specimen peeling rate, and incidence of serious adverse reactions between the two groups (P>0.05). CONCLUSIONS: Both staining methods comply with C-ROSE criteria in the biopsy setting of peripheral lung cancer. Rapid HE staining is more aligned with domestic clinical requirements and holds potential for further promotion and adoption in C-ROSE.


Asunto(s)
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Eosina Amarillenta-(YS) , Evaluación in Situ Rápida , Biopsia con Aguja/métodos , Coloración y Etiquetado
8.
Clin Imaging ; 95: 92-96, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36706641

RESUMEN

PURPOSE: To summarize imaging and histopathologic characteristics of hydrogel sealant (plug) in lung parenchyma and assess their correlation with time since deployment of sealant. MATERIALS AND METHODS: Among a total of 208 participants randomized to the hydrogel sealant arm of a lung biopsy prospective randomized clinical trial, 51 underwent resection of the biopsied lesion. In 34 participants sealant material was present on histopathologic sections (n = 22), or they had cross-sectional imaging of chest between biopsy and resection (n = 23) or they had both imaging and histopathology (n = 11). Histopathologic and imaging findings were described. The association of these findings with time since sealant deployment was evaluated using the Wilcoxon rank sum test. RESULTS: The mean time since sealant deployment for histopathology was 45.7 days (median 36, range 14-181) and for imaging studies was 99 days (median 32, range 4-527). The sealant was infiltrated by inflammatory cells in 20 (91%) participants. The main general histopathologic pattern of sealant was foamy in 12 (57%) and mesh in 8 (38%) participants. Imaging appearance of sealant was serpiginous in 18 (60%), linear in 10 (33%) or lobulated in 2 (6.7%) participants. In 2 participants the sealant was hypermetabolic with no histopathologic evidence of tumor. No correlation was found between time since sealant deployment and imaging or histopathologic appearances. CONCLUSION: Hydrogel sealant appears as a serpiginous, linear, or lobulated opacity on cross-sectional imaging which can be metabolically active. It is associated with an inflammatory reaction with a foamy or mesh general pattern on histopathological assessment. No correlation was found between time since sealant deployment and imaging or histopathologic appearances.


Asunto(s)
Hidrogeles , Neoplasias Pulmonares , Humanos , Hidrogeles/uso terapéutico , Estudios Prospectivos , Pulmón/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/patología , Tomografía Computarizada por Rayos X/métodos
9.
BMC Res Notes ; 15(1): 353, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36457053

RESUMEN

OBJECTIVES: Complications after CT-guided lung biopsy is a burden both for the individual patient and for the overall healthcare. Pneumothorax is the most common complication. This study determined the association between lung function tests and pneumothorax and chest drainage following CT-guided lung biopsy in consecutive patients in a large university hospital. RESULTS: We prospectively registered 875 biopsy procedures from 786 patients in one institution from January 27th 2012 to March 1st 2017 and recorded complications including pneumothorax with or without chest drainage. Lung function data from 637 patients undergoing 710 of the procedures were available. The association of lung function measures with pneumothorax with or without chest drainage was assessed using multivariable logistic regression analyses. Diffusion capacity for carbon monoxide (DLCO) below 4.70 mmol/min/kPa was associated with increased occurrence of pneumothorax and chest drainage after CT guided lung biopsy. We found no association between FEV1, RV and occurrence of pneumothorax and chest drainage. We found low DLCO to be a risk factor of pneumothorax and chest drainage after CT-guided lung biopsy. This should be taken into account in planning and performing the procedure.


Asunto(s)
Neumotórax , Humanos , Neumotórax/diagnóstico por imagen , Neumotórax/etiología , Tórax , Biopsia Guiada por Imagen/efectos adversos , Tomografía Computarizada por Rayos X , Pulmón/diagnóstico por imagen
10.
Front Microbiol ; 13: 1005241, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36187941

RESUMEN

Objective: This study aimed to investigate the diagnostic efficacy of computed tomography (CT)-guided transthoracic lung core needle biopsy combined with aspiration biopsy and the clinical value of this combined routine microbial detection. Materials and methods: We retrospectively collected the electronic medical records, CT images, pathology, and other data of 1085 patients with sequential core needle biopsy and aspiration biopsy of the same lung lesion under CT guidance in the First Affiliated Hospital of Wenzhou Medical University from January 2016 to January 2021. GenXpert MTB/RIF detection and BD BACTEC™ Mycobacterium/fungus culture were applied to identifying the microbiological results of these patients. We then compared the positive diagnostic rate, false negative rate, and diagnostic sensitivity rate of three methods including core needle biopsy alone, aspiration biopsy alone, and both core needle biopsy and aspiration biopsy. Results: The pathological results of cutting histopathology and aspiration of cell wax were examined for 1085 patients. The diagnostic rates of cutting and aspiration pathology were 90.1% (978/1085) and 86.3% (937/1085), respectively, with no significant difference (P > 0.05). Considering both cutting and aspiration pathologies, the diagnostic rate was significantly improved, up to 98% (1063/1085) (P < 0.001). A total of 803 malignant lesions were finally diagnosed (803/1085, 74.0%). The false negative rate by cutting pathology was 11.8% (95/803), which was significantly lower than that by aspiration biopsy [31.1% (250/803), P < 0.001]. Compared with core needle biopsy alone, the false negative rate of malignant lesions decreased to 5.6% (45/803) (P < 0.05). Next, the aspirates of the malignant lesions highly suspected of corresponding infection were cultured. The results showed that 16 cases (3.1%, 16/511) were infected with Mycobacterium tuberculosis complex, Aspergillus niger, and Acinetobacter baumannii, which required clinical treatment. 803 malignant tumors were excluded and 282 cases of benign lesions were diagnosed, including 232 cases of infectious lesions (82.3%, 232/282). The diagnostic rate of Mycobacterium/fungus culture for infectious lesions by aspiration biopsy (47.4%) was significantly higher than that by lung core needle biopsy (22.8%; P < 0.001). The diagnostic rate of aspiration biopsy combined with core needle biopsy was 56% (130/232). The parallel diagnostic rate of aspirated biopsy for GenXpert detection and Mycobacterium/fungal culture combined with core needle biopsy was 64.7% (150/232), which was significantly higher than that of lung core needle biopsy alone (P < 0.001). Finally, pulmonary tuberculosis was diagnosed in 90 cases (38.8%) of infectious lesions. Compared with the sensitivity of core needle biopsy to detect tuberculosis (27.8%, 25/90), the sensitivity of aspirating biopsy for GenXpert detection and Mycobacterium/fungal culture was significantly higher, at 70% (63/90) and 56.7% (51/90), respectively. Although there was no significant difference in the sensitivity of aspirated biopsy for GenXpert and Mycobacterium/fungal culture to detect pulmonary tuberculosis, the sensitivity was significantly increased to 83.3% (P < 0.05) when the two tests were combined. Moreover, when aspirated biopsies were combined with GenXpert detection, Mycobacterium/fungus culture, and core needle biopsy, the sensitivity was as high as 90% (81/90). Conclusion: CT-guided lung aspiration biopsy has a significant supplementary effect on core needle biopsies, which is indispensable in clinical application. Additionally, the combination of aspiration biopsy and core needle biopsy can significantly improve the diagnostic rate of benign and malignant lesions. Aspiration biopsy showed that pulmonary malignant lesions are complicated with pulmonary tuberculosis, aspergillus, and other infections. Finally, the diagnostic ability of lung puncture core needle biopsy and aspiration biopsy combined with routine microbial detection under CT positioning in the diagnosis of pulmonary infectious diseases was significantly improved.

11.
Respirol Case Rep ; 10(10): e01038, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36090020

RESUMEN

A 76-year-old woman underwent transbronchial lung cryobiopsy (TBLC) and transbronchial lung biopsy (TBLB) for examination of interstitial infiltrates. After the examination, the patient's consciousness became clouded, and head computed tomography showed an air embolus. She was started on 100% oxygen, and her consciousness improved, but she remained hemiplegic on the left side and dysphagic. Vascular air embolism (VAE) is a rare but serious complication. Although cases of VAE have been reported with conventional transbronchial forceps biopsy, cases of VAE after TBLC are quite rare, and thus this case is reported.

12.
Eur J Radiol ; 142: 109874, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34339955

RESUMEN

PURPOSE: [18F]-Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET/CT) has a central role in the lung nodules' characterization even if, with SUV < 2.5, percutaneous CT-guided Lung Biopsy (CTLB) is needed to assess nodule nature. In that scenario, CT Texture Analysis (CTTA) could be a non-invasive imaging biomarker. Our purpose is to test CTTA ability in differentiating malignant from benign nodules. METHOD: Patients that underwent FDG PET/CT followed by CTLB between January 2013 and December 2018 were retrospectively enrolled. Were included patients with lung nodule SUV < 2.5 and histological diagnosis. EXCLUSION CRITERIA: nodules SUV > 2.5, patients who refused CTLB or received oncological treatment before CTLB, indeterminate pathology report, CT motion artifacts. Two radiologists in consensus performed CTTA, drawing a volumetric Region of Interest of nodule with a dedicated first order TA software with and without spatial scaling filters, on preliminary CT performed for CTLB. Statistics included a comparison between malignant and benign neoplasms distribution (2-tailed T-test or Mann-Whitney test according to normal/non-normal data distribution), P-values < 0.05 were considered statistically significant. CTTA accuracy was tested with Receiver Operating Characteristics (ROC) curve. RESULTS: Form an initial population of 1178, 46 patients encountered inclusion criteria. Pathologist reported 27/46 (59%) malignant and 19/46 (41%) benign nodules. In malignant lesions CTTA showed lower Kurtosis' and higher Skewness' values (all P ≤ 0.0013 and all filtered TA P < 0.024, respectively). ROC curve showed significant Area Under the Curve for Kurtosis and Skewness (0.654 and 0.642, P < 0.001) at medium filtration. CONCLUSIONS: CTTA is a promising radiological tool to characterize benign and malignant lung nodules, even in those cases without an altered glucose metabolism.


Asunto(s)
Neoplasias Pulmonares , Tomografía Computarizada por Tomografía de Emisión de Positrones , Biopsia , Fluorodesoxiglucosa F18 , Humanos , Pulmón , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía de Emisión de Positrones , Radiofármacos , Estudios Retrospectivos
13.
J Med Imaging Radiat Oncol ; 65(6): 686-693, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33955169

RESUMEN

INTRODUCTION: To retrospectively evaluate the incidence of and the risk factors for pneumothorax and intercostal catheter insertion (ICC) after CT-guided lung biopsy and to generate a risk prediction model for developing a pneumothorax and requiring an ICC. METHODS: 255 CT-guided lung biopsies performed for 249 lesions in 249 patients from August 2014 to August 2019 were retrospectively analysed using multivariate logistic regression analysis. Risk prediction models were established using backward stepwise variable selection and likelihood ratio tests and were internally validated using split-sample methods. RESULTS: The overall incidence of pneumothorax was 30.2% (77/255). ICC insertion was required for 8.32% (21/255) of all procedures. The significant independent risk factors for pneumothorax were lesions not in contact with pleura (P < 0.001), a shorter skin-to-pleura distance (P = 0.01), the needle crossing a fissure (P = 0.004) and emphysema (P = 0.01); those for ICC insertion for pneumothorax were a needle through emphysema (P < 0.001) and lesions in the upper lobe (P = 0.017). AUC of the predictive models for pneumothorax and ICC insertion were 0.800 (95% CI: 0.745-0.856) and 0.859 (95% CI: 0.779-0.939) respectively. Upon internal validation, AUC of the testing sets of pneumothorax and ICC insertion were 0.769 and 0.822 on average respectively. CONCLUSION: The complication rates of pneumothorax and ICC insertion after CT-guided lung biopsy at our institution are comparable to results from previously reported studies. This study provides highly accurate risk prediction models of pneumothorax and ICC insertion for patients undergoing CT-guided lung biopsies.


Asunto(s)
Neumotórax , Humanos , Biopsia Guiada por Imagen , Pulmón/diagnóstico por imagen , Neumotórax/diagnóstico por imagen , Neumotórax/epidemiología , Neumotórax/etiología , Radiografía Intervencional , Estudios Retrospectivos , Factores de Riesgo , Tomografía Computarizada por Rayos X
14.
J Belg Soc Radiol ; 104(1): 68, 2020 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-33283148

RESUMEN

Teaching point: Early depiction of systemic air embolism after percutaneous lung biopsy allows for timely adequate management to prevent potentially fatal complications.

15.
Jpn J Radiol ; 38(9): 890-898, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32297063

RESUMEN

PURPOSE: To assess the impact of cardiac motion during percutaneous computed tomography (CT)-guided core needle biopsy (PCT-CNB) of small lung lesions near pericardium, focusing on safety and diagnostic accuracy. MATERIALS AND METHODS: Seventy-eight PCT-CNBs were performed between March 2010 and June 2018 in 78 patients with small (≤ 20 mm) lung nodules, each within 10 mm of pericardium. Shifts in distance and length of interface separating lesions from pericardium were calculated and compared by cardiac chambers (left atrium, left ventricle, right atrium, or right ventricle). Risk factors for complications were subjected to univariate analysis, and diagnostic accuracy was assessed. RESULTS: The respective mean values were 0.8 ± 1.1 mm (range 0-5.1 mm) for shifts in distance and 1.5 ± 2.1 mm (range 0-10.8 mm) for length of interface. Neither parameter shifted significantly with respect to cardiac chambers (p > 0.05, both). Pneumothorax ensued in 28 patients (35.9%), and pulmonary hemorrhage occurred in 41 (52.6%). The overall sensitivity, specificity, and accuracy of PCT-CNB were 91.2%, 100%, and 93.2%, respectively. CONCLUSION: Our data indicate that cardiac motion has no impact on either the incidence of complications or the diagnostic accuracy of PCT-CNB in patients with small (≤ 20 mm) lung lesions near pericardium.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Femenino , Corazón/fisiología , Humanos , Biopsia Guiada por Imagen/métodos , Pulmón/diagnóstico por imagen , Pulmón/patología , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Pericardio/fisiología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven
16.
Quant Imaging Med Surg ; 10(5): 1008-1020, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32489925

RESUMEN

BACKGROUND: Pulmonary hemorrhage and hemoptysis are the second-most common and potentially life-threatening complications after pneumothorax following percutaneous computed tomography-guided transthoracic lung biopsy (PCTLB). Preventing hemorrhagic complications after PCTLB requires an accurate estimation of risk factors. This study investigated the risk factors associated with pulmonary hemorrhage and hemoptysis following PCTLB, and whether the ratio of main pulmonary artery diameter (mPAD) to ascending aorta diameter (mPAD/AAD ratio) is a risk factor. METHODS: We retrospectively analyzed 1,090 cases of PCTLB obtained from 1,050 patients using a core needle. The risk factors for overall pulmonary hemorrhage, higher-grade pulmonary hemorrhage, and hemoptysis were evaluated by multivariate analysis of patient characteristics, computed tomography (CT) imaging data including pulmonary artery diameter (mPAD) to ascending aorta diameter (mPAD/AAD) ratio, technical variables related to the biopsy, and pathologic findings. RESULTS: Pulmonary hemorrhage occurred in 31.38% (342/1,090) of PCTLB cases, including lower-grade (24.4%, 266/1,090) and higher-grade hemorrhage (6.97%, 76/1,090). The incidence of hemoptysis was 3.03% (33/1,090). Multivariate analysis revealed significant associations between overall pulmonary hemorrhage and lesion location in the lower lobe, subsolid and smaller lesions, greater lesion depth, and lung metastases. For higher-grade pulmonary hemorrhage, an mPAD/AAD ratio >1, smaller lesions, greater lesion depth, emphysema, and lung metastases were risk factors. Risk factors for hemoptysis were history of hypertension and lower- and higher-grade pulmonary hemorrhage. CONCLUSIONS: Pulmonary artery enlargement detected by CT (mPAD/AAD ratio >1) is independently associated with higher-grade pulmonary hemorrhage following PCTLB.

17.
Cureus ; 11(8): e5408, 2019 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-31632862

RESUMEN

A 61-year-old male with a history of poorly differentiated squamous cell carcinoma of tongue who completed chemo-radiation was found to have bilateral lung nodules on follow-up positron emission tomography (PET) scan. He underwent computed tomography (CT)-guided lung biopsy. Sequential chest scans done during the procedure showed air-fluid level in the left ventricle, suggestive of air embolism. He was hemodynamically stable during the procedure, however at the end of the procedure he developed right-sided face and arm weakness with aphasia. Emergent CT scans including angiography of head and neck were done which did not show any bleed and was also negative for any air in intracranial vasculature. Patient was treated with 100% oxygen. His neurological symptoms resolved in 30 minutes and he was subsequently admitted to intensive care unit (ICU) for further management. Six hours later, repeat CT of chest was done which showed resolution of air embolism.

18.
Cardiovasc Intervent Radiol ; 42(8): 1062-1072, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30863965

RESUMEN

This systematic review and meta-analysis investigated post-biopsy manoeuvres to reduce pneumothorax following computed tomography-guided percutaneous transthoracic lung biopsy. Twenty-one articles were included with 7080 patients. Chest drain insertion rates were significantly reduced by ninefold with the normal saline tract sealant compared to controls (OR 0.11, 95% CI 0.02-0.48), threefold with the rapid rollover manoeuvre to puncture site down (OR 0.34, 95% CI 0.18-0.63), threefold with the tract plug (OR 0.33, 95% CI 0.22-0.48) and threefold with the blood patch (OR 0.39, 95% CI 0.26-0.58). The absolute chest drain insertion rates were the lowest in the normal saline tract sealant (0.8% vs 7.3% for controls), rapid rollover (1.9% vs 5.2%), deep expiration and breath-hold on needle extraction (0.9% vs 1.8%) and standard rollover versus no rollover (2.6% vs 5.2%). These findings highlight post-biopsy manoeuvres which could help reduce pneumothorax and chest drain insertions following lung biopsies. LEVEL OF EVIDENCE: Level 1/no level of evidence, systematic review.


Asunto(s)
Pulmón/patología , Neumotórax/prevención & control , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Biopsia Guiada por Imagen/efectos adversos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Neumotórax/etiología , Estudios Retrospectivos , Factores de Riesgo
19.
Semin Intervent Radiol ; 36(2): 68-71, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31123374

RESUMEN

Systemic air embolism (SAE) is a rare but serious complication of percutaneous core needle biopsy (PCNB) of the lung. Incidence of clinically apparent SAE is estimated at 0.061%, while clinically silent SAE may be as high as 3.8%. We present the complication of a small SAE during PCNB of the lung in a 78-year-old patient, which resulted in a transient myocardial ischemic event. This case highlights the importance of understanding the mechanism, frequency, and management of rare complications of PCNB of the lung; these complications should be considered in preoperative risk stratification. Regarding evaluation of postbiopsy computed tomography, operators should utilize a systematic search pattern to assess for complications. Level of Evidence: Level 4, Case Report.

20.
Eur J Radiol Open ; 6: 175-181, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31080850

RESUMEN

PURPOSE: To assess the success of determining malignancy in subsolid lung nodules by fine needle aspirate of CT-guided transthoracic needle biopsy. MATERIAL AND METHOD: This IRB approved retrospective study analyzed CTguided transthoracic needle biopsy of 86 consecutive subsolid nodules (size 25 + 14 mm; Age 71 + 10 years: M: F, 27:59), with ground glass opacity of = 50% in 64 (74%) and size < 2 cm in 38 (44%). Fine needle aspirate was performed in all and additional core biopsy in 21 (24%). The biopsy results were correlated with resected surgical pathology in 59 (69%) and by long term clinical and imaging follow-up in 27 (31%). The statistical analysis was performed by Fischer exact test to determine the success rate in < 2cm and =2cm nodules and those with <50% and =50% ground glass opacity. RESULTS: The technical success of performing the biopsy was 94.7%. The sensitivity for making a diagnosis of malignancy in small and large subsolid nodules was 88.6 and 95.6% (p=>0.05), with a specificity 100% in both groups. Core biopsy altered the diagnosis only in 1/21 (4.8%). The nondiagnostic biopsy rate was 18 and 11% for lesions with =50% and <50% ground glass opacity (p=>0.05). The incidence of pneumothorax was 21%, none requiring chest tube, and mild hemoptysis in 8%. CONCLUSION: CT-guided transthoracic needle biopsy of both small and large subsolid nodules is highly sensitive and very specific for making the diagnosis of malignancy with a low rate of complications. Additional core biopsy offered no significant advantage over fine needle aspirate biopsy alone.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA