Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 25(1): 810, 2024 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-39402546

RESUMEN

INTRODUCTION: Proximal femoral nailing (PFN) offers biomechanical benefits for intertrochanteric fractures but can lead to higher complication rates from poor reduction and technique errors, particularly in obese patients. Incorrect entry points may cause reduction loss, iatrogenic fractures, and misplaced lag screws. The study aims to investigate the effect of using an oriented flexible reamer instead of a rigid reamer on clinical and radiological results to obtain a medial entry point and better positioning of the nail in the intramedullary area in obese intertrochanteric fracture patients. MATERIALS AND METHODS: A retrospective analysis was conducted on patients aged 65 years and older who underwent PFN treatment between March 2020 and June 2022 at a single institution, with at least 1-year postoperative follow-up. Patients were divided into two groups: those applied with a flexible reamer and a rigid reamer. Parameters analyzed from postoperative radiographs included tip-apex distance (TAD), calcar-referenced tip-apex distance (CalTAD), reduction quality, femoral neck-shaft angle, and lag screw placement. Complication rates and types were recorded for each group. RESULT: The analysis included 91 patients, with 45 treated using a flexible reamer and 46 treated using a rigid reamer. There was no statistical difference between the two groups regarding age, gender, BMI, and AO class distributions of the patients (p > 0.05). The Femur neck shaft angle was significantly higher in the flexible reamer group (p < 0.001). As a result of the reduction types analysis, medial type reduction was significantly higher in the group where the flexible reamer was applied (p < 0.001). The CalTAD was shorter in the Flexible reamer group (p = 0.005). Complications and the need for reoperation were statistically significantly higher in the rigid reamer group (p < 0.048). CONCLUSION: The oriented flexible reamer reduces application-related errors in patients undergoing proximal femoral nail (PFN) treatment due to intertrochanteric fracture. The oriented flexible reamer technique allows a more medial entry point. Oriented flexible reamer creates enough space on both fracture sides at the level of intertrochanteric fracture to avoid nail pass-related complications. LEVEL OF EVIDENCE: Level III, Case-control study.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Femenino , Estudios Retrospectivos , Masculino , Anciano , Fracturas de Cadera/cirugía , Fracturas de Cadera/diagnóstico por imagen , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/efectos adversos , Anciano de 80 o más Años , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Obesidad/complicaciones , Resultado del Tratamiento , Tornillos Óseos
2.
Eur J Orthop Surg Traumatol ; 34(6): 3365-3371, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38922404

RESUMEN

Cephalomedullary nailing for unstable proximal femoral fractures is widely utilized, especially for geriatric osteoporotic fractures. There are two starting points for entry, namely trochanteric tip entry and pyriformis fossa entry, both have advantages and disadvantages, the tip of the greater trochanter seems that it is not the ideal starting point for trochanteric entry nails, the study presents the foothill entry point as a reproducible, technically feasible entry point to overcome the shortcoming of both standard starting points, and it could be easy executed with clear intraoperative fluoroscopic landmarks and lead to appropriate nail position without intraoperative complications.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fluoroscopía/métodos , Fracturas de Cadera/cirugía , Fracturas de Cadera/diagnóstico por imagen , Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Fracturas Femorales Proximales
3.
BMC Musculoskelet Disord ; 23(1): 354, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35414068

RESUMEN

BACKGROUND: It is irresponsible if we disregard reduction quality to talk about cut-outs in intertrochanteric fractures (ITF) with internal fixation. The aim of this study is to analyze the risk-factors for cut-outs in geriatric ITF with cephalomedullary nailing after obtaining acceptable reduction. METHODS: In order to investigate the risk-factors for cut-outs in geriatric ITF after obtaining acceptable reduction, we retrospectively reviewed 367 patients who underwent cephalomedullary nail for ITF in our department between September 2016 and December 2021. Potential variables including demographic data and radiological parameters (namely the fracture type, Singh index, lateral wall fracture, cephalic nail position, Parker's ratio index, tip-apex-distance (TAD), and calcar-referenced TAD (CalTAD)) were collected. Logistic regression analysis was performed to identify the significant risk factors for cut-outs. RESULTS: One hundred twenty-one patients were suitable for this study. Of the 121 cases, nine cases (7.4%) were observed with cut-out or pending cut-out. We found that Age (adjusted odds ratio (OR) 1.158, 95% confidence interval (CI) 1.016 to 1.318, p = 0.028), lateral wall fracture (adjusted OR 11.07, 95%CI 1.790 to 68.380, p = 0.01), and CalTAD (adjusted OR 1.277, 95%CI 1.005 to 1.622, p = 0.045) were independent risk-factors for cut-outs. CONCLUSIONS: Age, lateral wall fracture and CalTAD are independent risk-factors for cut-outs in geriatric ITF with cephalomedullary nailing after obtaining acceptable reduction. In order to avoid cut-outs, an optimal CalTAD is necessary even obtaining acceptable reduction, especially in the over-aged patients with lateral wall fracture.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Anciano , Clavos Ortopédicos , Tornillos Óseos , Estudios de Casos y Controles , Fijación Intramedular de Fracturas/efectos adversos , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/etiología , Fracturas de Cadera/cirugía , Humanos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
4.
BMC Musculoskelet Disord ; 23(1): 175, 2022 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-35209887

RESUMEN

BACKGROUND: Maintaining anteromedial cortical support is essential for controlling sliding and decreasing postoperative implant-related complications. However, adequate fracture reduction with cortical support in immediate postoperative fluoroscopy is not invariable in postoperative follow-ups. This study was conducted to investigate the risk factors leading to anteromedial cortical support failure in follow up for pertrochanteric femur fractures treated with cephalomedullary nails. METHODS: This retrospective study enrolled 159 patients with pertrochanteric fractures (AO/OTA- 31A1 and 31A2) that fixed with cephalomedullary nails. All patients were evaluated as adequate fracture reduction in immediate postoperative fluoroscopy before leaving the operation theater. The patients were separated into two groups based on the condition of the anteromedial cortex in the postoperative 3D CT with full-range observation: those with calcar support maintained in Group 1 and those with calcar support lost in Group 2. Demographic information, fracture classification, TAD (tip-apex distance), Cal-TAD, Parker ratio, NSA (neck-shaft angle), reduction quality score, and calcar fracture gapping were collected and compared. Logistic regression analysis was conducted to explore the risk factors leading to anteromedial cortex change. RESULTS: Anteromedial cortical support failure was noted in 46 cases (29%). There was no significant difference between the two groups concerning age, sex, side injury, TAD, Cal-TAD, Parker ratio, or NSA. There was a significant difference in the AO/OTA fracture classification in univariate analysis but no difference in the multivariable analysis. The reduction quality score, calcar fracture gapping in the AP (anteroposterior), and lateral views were significantly associated with anteromedial cortical support failure in follow-up after cephalomedullary nailing in the multivariable analysis. The threshold value of calcar fracture gapping for the risk of loss was 4.2 mm in the AP and 3.8 mm in the lateral fluoroscopies. Mechanical complications (lateral sliding and varus) were frequently observed in the negative anteromedial cortical support group. CONCLUSIONS: Good reduction quality was a protective factor, and larger calcar fracture gapping in the AP and lateral views were risk factors leading to the postoperative loss of anteromedial cortical support. Therefore, we should pay close attention to fracture reduction and minimize the calcar fracture gap during surgery.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Clavos Ortopédicos/efectos adversos , Fémur/cirugía , Fijación Intramedular de Fracturas/efectos adversos , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/etiología , Fracturas de Cadera/cirugía , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
5.
Arch Orthop Trauma Surg ; 142(12): 3787-3796, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34748055

RESUMEN

BACKGROUND: Recently, two novel concepts for intramedullary nailing of trochanteric fractures using a helical blade or interlocking dual screws have demonstrated advantages as compared to standard single-screw systems. However, these two concepts have not been subjected to a direct biomechanical comparison so far. The aims of this study were to investigate in a human cadaveric model with low bone quality (1) the biomechanical competence of nailing with the use of a helical blade versus interlocking screws, and (2) the effect of cement augmentation on the fixation strength of the helical blade. METHODS: Twelve osteoporotic and osteopenic human cadaveric femoral pairs were assigned for pairwise implantation using either a short TFN-ADVANCED Proximal Femoral Nailing System (TFNA) with a helical blade head element or a short TRIGEN INTERTAN Intertrochanteric Antegrade Nail (InterTAN) with interlocking screws. Six osteoporotic femora, implanted with TFNA, were augmented with bone cement. Four groups were created: group 1 (TFNA) paired with group 2 (InterTAN), both consisting of osteopenic specimens, and group 3 (TFNA augmented) paired with group 4 (InterTAN), both consisting of osteoporotic specimens. An unstable trochanteric AO/OTA 31-A2.2 fracture was simulated and all specimens were tested until failure under progressively increasing cyclic loading. RESULTS: Stiffness in group 3 was significantly higher versus group 4, p = 0.03. Varus (°) and femoral head rotation around the femoral neck axis (°) after 10,000 cycles were 1.9 ± 1.0/0.3 ± 0.2 in group 1, 2.2 ± 0.7/0.7 ± 0.4 in group 2, 1.5 ± 1.3/0.3 ± 0.2 in group 3 and 3.5 ± 2.8/0.9 ± 0.6 in group 4, being significantly different between groups 3 and 4, p = 0.04. Cycles to failure and failure load (N) at 5° varus or 10° femoral head rotation around the neck axis in groups 1-4 were 21,428 ± 6020/1571.4 ± 301.0, 20,611 ± 7453/1530.6 ± 372.7, 21,739 ± 4248/1587.0 ± 212.4 and 18,622 ± 6733/1431.1 ± 336.7, being significantly different between groups 3 and 4, p = 0.04. CONCLUSIONS: Nailing of trochanteric femoral fractures with use of helical blades is comparable to interlocking dual screws fixation in femoral head fragments with low bone quality. Bone cement augmentation of helical blades provides significantly greater fixation strength compared to interlocking screws constructs.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Tornillos Óseos , Cementos para Huesos , Uñas , Cadáver , Fracturas de Cadera/cirugía , Clavos Ortopédicos , Fenómenos Biomecánicos
6.
Medicina (Kaunas) ; 58(11)2022 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-36422175

RESUMEN

Background and Objectives: Intramedullary nailing of trochanteric fractures can be challenging and sometimes the clinical situation does not allow perfect implant positioning. The aim of this study was (1) to compare in human cadaveric femoral heads the biomechanical competence of two recently launched cephalic implants inserted in either an ideal (centre-centre) or less-ideal anterior off-centre position, and (2) to investigate the effect of bone cement augmentation on their fixation strength in the less-ideal position. Materials and Methods: Fourty-two paired human cadaveric femoral heads were assigned for pairwise implantation using either a TFNA helical blade or a TFNA screw as head element, implanted in either centre-centre or 7 mm anterior off-centre position. Next, seven paired specimens implanted in the off-centre position were augmented with bone cement. As a result, six study groups were created as follows: group 1 with a centre-centre positioned helical blade, paired with group 2 featuring a centre-centre screw, group 3 with an off-centre positioned helical blade, paired with group 4 featuring an off-centre screw, and group 5 with an off-centre positioned augmented helical blade, paired with group 6 featuring an off-centre augmented screw. All specimens were tested until failure under progressively increasing cyclic loading. Results: Stiffness was not significantly different among the study groups (p = 0.388). Varus deformation was significantly higher in group 4 versus group 6 (p = 0.026). Femoral head rotation was significantly higher in group 4 versus group 3 (p = 0.034), significantly lower in group 2 versus group 4 (p = 0.005), and significantly higher in group 4 versus group 6 (p = 0.007). Cycles to clinically relevant failure were 14,919 ± 4763 in group 1, 10,824 ± 5396 in group 2, 10,900 ± 3285 in group 3, 1382 ± 2701 in group 4, 25,811 ± 19,107 in group 5 and 17,817 ± 11,924 in group 6. Significantly higher number of cycles to failure were indicated for group 1 versus group 2 (p = 0.021), group 3 versus group 4 (p = 0.007), and in group 6 versus group 4 (p = 0.010). Conclusions: From a biomechanical perspective, proper centre-centre implant positioning in the femoral head is of utmost importance. In cases when this is not achievable in a clinical setting, a helical blade is more forgiving in the less ideal (anterior) malposition when compared to a screw, the latter revealing unacceptable low resistance to femoral head rotation and early failure. Cement augmentation of both off-centre implanted helical blade and screw head elements increases their resistance against failure; however, this effect might be redundant for helical blades and is highly unpredictable for screws.


Asunto(s)
Cementos para Huesos , Fracturas de Cadera , Humanos , Clavos Ortopédicos , Tornillos Óseos , Fracturas de Cadera/cirugía , Cadáver
7.
BMC Musculoskelet Disord ; 20(1): 124, 2019 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-30909898

RESUMEN

BACKGROUND: Antiplatelet medication has been frequently performed in elderly patients with hip fracture, because of comorbidities. This observational cohort study was to evaluate the effect of continuous perioperative antiplatelet medication on the outcomes after cephalomedullary nailing (CMN) in elderly patients with a proximal femur fracture. METHODS: One hundred and sixty-two consecutive patients aged ≥70 years undergoing CMN for proximal femur fracture between January 2015 and January 2017 were recruited. Of the 162 patients, 47 (study group) taking antiplatelets preoperatively due to comorbidities were compared with 107 (control group) who were not on antiplatelets. 8 patients taking anticoagulant medication were excluded. Postoperative hemoglobin (Hb) and hematocrit (Hct) levels, transfusion amount and estimated blood loss (EBL), occurrence of venous thromboembolism (VTE) and delirium, intensive care unit (ICU) admission, complications, length of hospital stay, readmission, and in-hospital and 1-year mortalities were measured and compared between the two groups. RESULTS: A higher number of patients in the study group had concomitant cardiovascular (p = 0.006) and endocrinologic (p = 0.004) diseases, received perioperative transfusion (p = 0.003), and were admitted to ICU postoperatively (p = 0.014). However, there were no significant differences in postoperative Hb and Hct levels, EBL, length of hospital stay, and the incidences of VTE and delirium between the two groups. In addition, in-hospital and 1-year mortalities as well as postoperative complications showed no significant differences between both groups. CONCLUSIONS: CMN can be performed without delay in elderly patients with proximal femoral fracture receiving antiplatelet therapy prior to admission without discontinuing antiplatelets, and is as safe as in patients who are not on antiplatelet medication. However, more caution is required with respect to transfusions and ICU care after surgery in these patients.


Asunto(s)
Fracturas del Fémur/tratamiento farmacológico , Fracturas de Cadera/tratamiento farmacológico , Atención Perioperativa/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Complicaciones Posoperatorias/prevención & control , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Fracturas del Fémur/cirugía , Fracturas de Cadera/cirugía , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico , Estudios Retrospectivos
8.
Arch Orthop Trauma Surg ; 138(3): 351-359, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29273922

RESUMEN

BACKGROUND: Cut-out is the most common mechanical complication of the osteosynthesis of pertrochanteric fractures. This complication determines a significant increase in morbidity in elderly patient. Cut-out is defined as the varus collapse of the femoral head-neck fragment with the extrusion of the cephalic screw. Surgical treatment of cut-out might lead to further complications, longer rehabilitation, increased social burden and healthcare system costs. The aim of the study is to identify the predictors of cut-out to prevent its occurrence. MATERIALS AND METHODS: Study population included all patients affected by extracapsular fracture of the proximal femur who were admitted and treated with short cephalomedullary nailing at the Cattinara Hospital-ASUITS of Trieste between 2009 and 2014. A retrospective analysis of clinical and radiographic data was carried out and cut-out cases recorded. The data collected on the study population were analyzed to find an eventual correlation with the occurrence of cut-out. The independent variables were age, gender, side of the fracture, ASA class, Evans classification, nailing system, quality of reduction, TAD, CalTAD, and Parker ratio. RESULTS: The study population counted 813 cases, with an F:M ratio of 4:1 and a mean age of 84.7 years. The cut-out was recorded in 18 cases (2.2%). There was no statistically significant association between cut-out and age, sex, side of fracture, ASA class, and nailing system. The Evans classification, the quality of reduction, the TAD, the CalTAD, and the Parker's ratio demonstrated a significant correlation at univariate analysis with cut-out. The results of multivariate analysis confirmed that TAD, Parker AP, and quality of reduction were independently significantly correlated to cut-out. CONCLUSION: The results of the present study demonstrate that good quality of reduction and correct position of the lag screw are likely to decrease the risk of cut-out complication. A nomogram for cut-out prediction is proposed for clinical validation.


Asunto(s)
Tornillos Óseos/efectos adversos , Fijación Intramedular de Fracturas/efectos adversos , Fracturas de Cadera/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Fracturas de Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Retrospectivos
9.
Int Orthop ; 40(1): 15-20, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25947904

RESUMEN

PURPOSE: Cephalomedullary (CM) nailing is widely used for the treatment of pertrochanteric hip fractures. Fixation failures with CM nailing tend to occur in unstable fracture patterns often necessitating revision surgery. The purpose of this study was to compare the complications and clinical outcomes of primary arthroplasty to CM nailing for the treatment of unstable pertrochanteric hip fractures. METHODS: We conducted an age-, sex-, and fracture type-matched case-controlled study and identified 29 patients who underwent hip arthroplasty for an unstable pertrochanteric fracture (AO/OTA classification type 31A2.2/3 and 31.A3) at our institution. Their outcome was compared to a matched control group of 29 patients treated with a CM nail. RESULTS: There was one major complication in the arthroplasty group (3.4 %), whereas there were six major complications in the nailing group (20.7 %) (P = 0.04). We found no significant difference between the groups with regards to blood loss, operative time, hospitalization time and the number of patients discharged to rehabilitation. Clinical outcome measured with Oxford hip score and SF-12 at the time of final follow-up was not significantly different between the groups. CONCLUSIONS: Arthroplasty is a viable option for treatment of unstable pertrochanteric fractures in an elderly population. Arthroplasty may offer a lower re-operation rate in the treatment of unstable pertrochanteric hip fractures as compared to CM nailing.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Clavos Ortopédicos , Fijación Intramedular de Fracturas/métodos , Fracturas de Cadera/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Casos y Controles , Femenino , Fijación Intramedular de Fracturas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Resultado del Tratamiento
10.
Iowa Orthop J ; 44(1): 167-171, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38919366

RESUMEN

Background: This study aimed to demonstrate the feasibility of lag screw exchange for painful lateral soft tissue impingement in patients initially treated with cephalomedullary nailing (CMN) for an intertrochanteric hip fracture. Methods: Ten patients initially treated with CMN for unstable intertrochanteric fractures presenting with persistent pain and radiographic evidence of lag screw lateral migration were treated with exchange of original screw with shorter lag screw buried in the lateral cortex to prevent impingement. Patients were evaluated for resolution of pain and achievement of pre-fracture ambulatory status at 6 months post-operatively. Results: Average age was 71.5 years (range: 62-88). Average length of follow-up was 24.9 months. All patients were female, with an average Charlson Comorbidity Index of 1.0 (0-3) and average Body Mass Index of 22.2 (16.0-31.1). Five of ten patients (50.0%) were treated with a cortisone injection in the trochanteric bursa prior to screw exchange with temporary pain relief. Five (50.0%) patients presented with limited range of hip motion. Five (50.0%) had history of prior or current bisphosphonate use. Average lag screw prominence was noted to be 12.2mm (7.9-17.6mm) on radiographic evaluation. Screw exchange was performed at an average of 18.6 months (5.4-44.9 months) following the index procedure. Average operating time of the screw exchange procedure was 45.3 minutes (34-69 minutes) and blood loss was <50mL in all cases. Replacement lag screws were an average of 16.0mm (10-25mm) shorter than the initial screw. All patients achieved complete or significant resolution of lateral thigh pain, and nine (90%) returned to pre-fracture ambulatory status by eight weeks after screw exchange. All patients remained pain free at six months after screw exchange. Conclusion: Lag screw exchange is a efficacious method to address the mechanical irritation of laterally protruding lag screws following IT hip fracture, while also prophylaxing against subsequent femoral neck fractures. Level of Evidence: IV.


Asunto(s)
Tornillos Óseos , Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Femenino , Fracturas de Cadera/cirugía , Anciano , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Anciano de 80 o más Años , Persona de Mediana Edad , Resultado del Tratamiento , Reoperación , Clavos Ortopédicos , Rango del Movimiento Articular
11.
Clin Orthop Surg ; 16(3): 397-404, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38827762

RESUMEN

Background: The objective of this study was to investigate the incidence of osteonecrosis of the femoral head (ONFH) after cephalomedullary nailing in elderly patients with pertrochanteric fractures and to analyze the risk factors related to ONFH. Methods: A total of 689 consecutive patients with cephalomedullary nailing for pertrochanteric fractures at our hospital were recruited. Of these, 368 patients who met the inclusion criteria were finally enrolled. ONFH after cephalomedullary nailing was identified by reviewing patients' electronic charts and serial radiographs. The ONFH group was then compared with the non-ONFH group. Results: ONFH was identified in 9 of 368 patients (2.4%). The time to diagnosis of ONFH averaged 23.8 months (range, 5-54 months) after index surgery. The mean age, body mass index, and bone mineral density (T-score in femur neck) were 84.1 ± 7.1 years, 23.7 ± 3.6 kg/m2, and -3.1 ± 0.7 kg/m2, respectively. The times from injury to surgery, from admission to surgery, and operation time averaged 4.2 ± 2.7 days, 3.6 ± 2.6 days, and 87.2 ± 30.0 minutes, respectively. Among 9 patients, 3 underwent conversion arthroplasty. The ONFH group had advanced age (p = 0.029), more basicervical fracture components (p = 0.002), and inadequate reduction (p = 0.045) compared to the non-ONFH group. On multivariate analysis, advanced age (odds ratio [OR], 1.61;, p = 0.022), basicervical fracture components (OR, 24.58; p = 0.001), and inadequate reduction (OR, 4.11; p = 0.039) were identified as risk factors of ONFH. Conclusions: Although ONFH is relatively rare after cephalomedullary nailing for pertrochanteric fractures in elderly patients, its risk may increase with advanced age, basicervical fracture components, and inadequate reduction. Therefore, in patients with these risk factors, meticulous and longer follow-up is needed even after bone union.


Asunto(s)
Necrosis de la Cabeza Femoral , Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Masculino , Femenino , Factores de Riesgo , Anciano , Anciano de 80 o más Años , Fracturas de Cadera/cirugía , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/métodos , Incidencia , Necrosis de la Cabeza Femoral/cirugía , Necrosis de la Cabeza Femoral/etiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Clavos Ortopédicos , Estudios Retrospectivos
12.
Orthop Traumatol Surg Res ; 109(7): 103619, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37044244

RESUMEN

INTRODUCTION: Proximal femur fractures have high rates of morbidity, mortality, and perioperative complications. Limiting anesthesia, especially in the elderly population, is a priority from a medical perspective. The goal of the current study is to present a technique of using local anesthetic with monitored anesthesia care (MAC) for the fixation of intertrochanteric (IT) femur fractures with cephalomedullary nailing (CMN), provide early clinical results in a small series of patients, and evaluate the safety, efficiency, and anesthetic efficacy of our technique. HYPOTHESIS: The use of only local anesthetic with MAC for the fixation of IT fractures is safe and leads to decreased operative times when compared to spinal and general anesthesia. MATERIALS AND METHODS: Patients undergoing cephalomedullary nailing (CMN) with a long nail for IT femur fractures by a single surgeon from January 2020 to June 2021 were identified retrospectively from a prospectively-collected patient registry. Patient demographics, operative time, length of hospital stay, perioperative medication use, and complications were collected. Analysis of variance, Chi2, linear regression, and two-sampled T-tests were performed to analyze potential differences between the local anesthesia group and the general or spinal anesthesia group. RESULTS: Thirty-seven patients were identified. Eleven patients underwent CMN using local anesthesia with MAC, 11 using spinal anesthesia, and 15 using general anesthesia. The local anesthesia group demonstrated significantly lower operating room times and anesthesia induction to incision time compared to other anesthesia techniques. The local anesthesia group also trended towards less need for vasopressors during surgery and less postoperative delirium. No differences were identified in intraoperative narcotic use, complications, patient mortality, or hospital readmissions. CONCLUSIONS: Local anesthesia with MAC for the treatment of IT fractures with CMN was associated with decreased operating room times and had similar complication rates including blood transfusions, readmissions, and mortalities, when compared to spinal and general anesthesia. LEVEL OF EVIDENCE: III, therapeutic.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Fracturas Femorales Proximales , Humanos , Anciano , Anestésicos Locales , Clavos Ortopédicos/efectos adversos , Estudios Retrospectivos , Anestesia Local/efectos adversos , Fracturas de Cadera/cirugía , Fémur , Fijación Intramedular de Fracturas/métodos , Resultado del Tratamiento
13.
J Orthop Surg Res ; 18(1): 542, 2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37507795

RESUMEN

BACKGROUND: Hip fractures are an increasingly common consequence of falls in older people that are associated with a high risk of death and reduced function. The vast majority of intertrochanteric fractures require surgical treatment to withstand early mobilization and weight bearing, which prevents complications due to prolonged bed rest and aids in fracture healing. METHODS: This study is compromised by two parts, the experimental study and the clinical part. In the first part, a standard 130° nail will be used with the appropriate lag screw(s) and dynamic distal locking in synthetic osteoporotic femurs and the transmission of forces in the proximal femur, measured by a cortical surface-strain distribution, will be evaluated using digital image correlation. Finite element parametric models of the bone, the nails and their interface will be also developed. Finite element computations of surface strains in implanted femurs, after being validated against biomechanical testing measurements, will be used to assist the comparison of the nails by deriving important data on the developed stress and strain fields, which cannot be measured through biomechanical testing. In the other part, will set up a prospective, randomized, comparative clinical study among the Gamma3 and IT cephalomedullary nailing, in order to investigate if there are any statistical important differences in the main radiological measurements and functional status in closed unstable intertrochanteric fractures (A21-3) in patients aged over 70 years old at the 24-week follow-up evaluation using patient reported disease-specific outcomes. DISCUSSION: This study will be the first to compare clinical, radiological and biomechanical measurements of the two different cephalomedullary nails. Our main hypothesis is that the IT nail would provide better radiological outcome and probably better clinical results than the Gama3 nail. Clinical trial registration International Standard Randomized Controlled Trial Number (ISRCTN): https://doi.org/10.1186/ISRCTN15588442 , registered on 19/4/2022.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Anciano , Anciano de 80 o más Años , Preescolar , Fijación Intramedular de Fracturas/métodos , Análisis de Elementos Finitos , Clavos Ortopédicos , Estudios Prospectivos , Tornillos Óseos , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto
14.
Injury ; 53(4): 1477-1483, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35120730

RESUMEN

INTRODUCTION: Intramedullary nailing (IMN), which is a common method for treating subtrochanteric fractures, is conducted as cephalomedullary (CMN) or reconstruction (RCN) nailing. Numerous studies have reported the effectiveness of CMN, which requires a shorter surgery time and provides stronger fixation strength with blade-type devices. However, the radiographic and clinical outcomes of the use of CMN and RCN in elderly patients aged ≥65 years have not been compared yet. This study aimed to investigate whether CMN offers superior outcomes over RCN in the treatment of subtrochanteric fractures in elderly patients. MATERIALS AND METHODS: This retrospective study included 60 elderly patients (17 men and 43 women; mean age: 74.9 years) diagnosed with subtrochanteric fractures and treated with IMN with helical blade CMN (CMN group: 30 patients) or RCN (RCN group: 30 patients) between January 2013 and December 2018 with at least 1 year of follow-up period. Radiologic outcomes were evaluated based on the postoperative state of alignment and the achievement and timing of bony union at the final follow-up. Clinical outcomes were evaluated using the Merle d'Aubigné-Postel score. Radiologic and clinical outcomes in the two groups were compared and analyzed, and the occurrence of complications was examined. RESULTS: The difference in malalignment between the two groups was not significant; however, the RCN group achieved more effective reduction. At the final follow-up, bony union was achieved within 18.9 weeks, on average, in 28 patients in the CMN group and within 21.6 weeks, on average, in 27 patients in the RCN group. Twenty patients in the CMN group and 26 in the RCN group showed good or better results according to the Merle d'Aubigné-Postel score. No significant differences were found for any of the parameters. CONCLUSIONS: In the treatment of difficult subtrochanteric fractures in elderly patients, RCN can provide excellent reduction and strong fixation similar to CMN and can result in outstanding clinical and radiologic outcomes.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Anciano , Clavos Ortopédicos , Femenino , Fijación Intramedular de Fracturas/métodos , Curación de Fractura , Mano , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/etiología , Fracturas de Cadera/cirugía , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
15.
Arch Bone Jt Surg ; 10(9): 785-790, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36246028

RESUMEN

Background: Total hip arthroplasty (THA)after previous hip surgery increases the procedure complexity and complication rate. We investigated the complication rates following conversion to total hip arthroplasty from three hip surgeries, namely plate fixation of the intertrochanteric fracture, nailing of the trochanteric fracture, and hemiarthroplasty of the hip. Methods: This retrospective study was conducted using the PearlDiver database (www.pearldiverinc.com, Colorado Springs) and identified all patients undergoing THA between 2010 and 2019. Among this group, we included all patients who had received one of the three procedures , hip hemiarthroplasty (CPT 27125), fixation of the intertrochanteric fracture with plates and screws (CPT 27444), or fixation of hip fracture with nail (CPT 27445) within two years of THA. We analyzed complications in these patients and compared it to the complication rate in primary THA patients. The complications analyzed were 30-day transfusion risk, 90-day surgical site infection (SSI) risk, 90-day periprosthetic fracture risk, 1-year dislocation risk, and 2-, 5-, and 10-year revision risk. Results: A total of 118,209 patients underwent THA between 2010 and 2019. A total of 9,173, 48,326, and 31,632 patients underwent fixation with plates and screws , nailing and hemiarthroplasty respectively. We identified 71, 42, and 160 patients with hemiarthroplasty, plates & screws, and nailing, respectively, within two years of THA. 117,936 primary THA patients were used as a comparison group. The nailing group had the highest rate of transfusion risk (OR=2.34, 95% CI=1.32, 4.13, P<0.05).Furthermore, the hemiarthroplasty group had highest rate of SSI risk (OR=9.25, 95% CI=4.86, 17.63, P<0.05) and highest revision risk at 2 years (OR=10.532, 95% CI= 6.09, 18.19, P<0.05). Conclusion: Conversion of hemiarthroplasty to THA was associated with a higher risk of infection and revision. Hence, surgeons considering primary hip hemiarthroplasty for severely comminuted intertrochanteric fracture should exercise caution, especially for active elderly patients.

16.
J Orthop Surg Res ; 17(1): 27, 2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-35033125

RESUMEN

BACKGROUND: Anteromedial cortical support apposition (positive and/or neutral cortical relations) is crucial for surgical stability reconstruction in the treatment of trochanteric femur fractures. However, the loss of fracture reduction is frequent in follow-ups after cephalomedullary nail fixation. This paper aimed to investigate the possible predictive risk factors for postoperative loss of anteromedial cortex buttress after nail fixation. METHODS: A retrospective analysis of 122 patients with AO/OTA 31A1 and A2 trochanteric femur fractures treated with cephalomedullary nails between January 2017 and December 2019 was performed. The patients were classified into two groups according to the postoperative status of the anteromedial cortical apposition in 3D CT images: Group 1 with contact "yes" (positive or anatomic) and Group 2 with contact "No" (negative, loss of contact). The fracture reduction quality score, tip-apex distance (TAD), calcar-referenced TAD (Cal-TAD), Parker ratio, neck-shaft angle (NSA), and the filling ratio of the distal nail segment to medullary canal diameter in anteroposterior (AP) and lateral fluoroscopies (taken immediately after the operation) were examined in univariate and multivariate analyses. Mechanical complications were measured and compared in follow-up radiographs. RESULTS: According to the postoperative 3D CT, 84 individuals (69%) were categorized into Group 1, and 38 individuals (31%) were classified as Group 2. The multivariate logistic regression analysis showed that the poor fracture reduction quality score (P < 0.001) and decreasing filling ratio in the lateral view (P < 0.001) were significant risk factors for the loss of anteromedial cortical contact. The threshold value for the distal nail filling ratio in lateral fluoroscopy predicting fracture reduction re-displacement was found to be 53%, with 89.3% sensitivity and 78.9% specificity. The mechanical complication (varus and over lateral sliding) rate was higher in Group 2. CONCLUSIONS: The fracture reduction quality score and the decreasing filling ratio of the distal nail to the medullary canal in the lateral view (a novel parameter causing pendulum-like movement of the nail) were possible risk factors for postoperative loss of anteromedial cortical support.


Asunto(s)
Clavos Ortopédicos , Fijación Interna de Fracturas/métodos , Fijación Intramedular de Fracturas , Fracturas de Cadera/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Fijación Intramedular de Fracturas/efectos adversos , Fracturas de Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Uñas , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
17.
Injury ; 53(12): 4072-4085, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36272844

RESUMEN

BACKGROUND: Despite recent advances in implants and surgical techniques, catastrophic and clinical failures in the treatment of intertrochanteric fractures continue to occur, with dire consequences in an overall frail population subset. The aim of the current study is to evaluate the effect of the factors under the surgeons' control, namely fracture reduction and implant selection, on the biomechanical behavior of fracture fixation constructs. MATERIAL-METHODS: An experimental protocol was conducted with the use of instrumented sawbones, in order to validate the finite element models. The implants used were the Gamma3®and DHS systems. Subsequently, a series of scenaria were considered, including various reduction and implant angle combinations. Data were retrieved concerning the peak cancellous bone stresses around the hip screw and the volume of cancellous bone in the femoral head stressed at critical levels, as well as implant stresses and stresses on the cortical bone of the distal fragment. RESULTS: All stable fracture models displayed significantly decreased cancellous bone stresses and implant stresses compared to their unstable counterparts, regardless of implant used. The effect of increasing implant angle led to a decrease in implant stresses in all models studied, but had a beneficial effect on the stresses in the cancellous bone of the proximal fragment only in the subgroups of stable fractures with both implants and unstable fractures treated with a cephalomedullary nail (CMN). In unstable fractures anatomically reduced, the use of CMN led to significantly lower peak stresses in the cancellous bone and a smaller volume of bone stressed at critical levels. Increasing the reduction angle by 5 ° led to a significant decrease in both peak stresses and volume of bone stressed at critical levels, more prominent in the sliding hip screw (SHS) models. Decreasing the reduction angle into varus by 5 or 10 ° led to a significant increase in bone and implant stresses regardless of implant used. CONCLUSIONS: In stable two-part (AO31.A2) fractures the use of the SHS appears to be biomechanically equivalent to CMN. In unstable, anatomically reduced fractures, the use of CMN leads to significantly reduced cancellous bone stresses and decreased rotation of the proximal fragment during loading. A reduction in varus should be avoided at all costs. In unstable fractures treated with SHS a reduction in slight valgus appears to be biomechanically beneficial. The highest implant angle that allows for proper screw position and trajectory in the femoral head should be used for stable fractures with both implants and unstable fractures treated with Gamma3®.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Fijación Intramedular de Fracturas/métodos , Análisis de Elementos Finitos , Tornillos Óseos , Fracturas de Cadera/cirugía , Cabeza Femoral/cirugía , Clavos Ortopédicos
18.
Bone Joint Res ; 11(3): 152-161, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35261280

RESUMEN

AIMS: There are concerns regarding nail/medullary canal mismatch and initial stability after cephalomedullary nailing in unstable pertrochanteric fractures. This study aimed to investigate the effect of an additional anteroposterior blocking screw on fixation stability in unstable pertrochanteric fracture models with a nail/medullary canal mismatch after short cephalomedullary nail (CMN) fixation. METHODS: Eight finite element models (FEMs), comprising four different femoral diameters, with and without blocking screws, were constructed, and unstable intertrochanteric fractures fixed with short CMNs were reproduced in all FEMs. Micromotions of distal shaft fragment related to proximal fragment, and stress concentrations at the nail construct were measured. RESULTS: Micromotions in FEMs without a blocking screw significantly increased as nail/medullary canal mismatch increased, but were similar between FEMs with a blocking screw regardless of mismatch. Stress concentration at the nail construct was observed at the junction of the nail body and lag screw in all FEMs, and increased as nail/medullary canal mismatch increased, regardless of blocking screws. Mean stresses over regions of interest in FEMs with a blocking screw were much lower than regions of interest in those without. Mean stresses in FEMs with a blocking screw were lower than the yield strength, yet mean stresses in FEMs without blocking screws having 8 mm and 10 mm mismatch exceeded the yield strength. All mean stresses at distal locking screws were less than the yield strength. CONCLUSION: Using an additional anteroposterior blocking screw may be a simple and effective method to enhance fixation stability in unstable pertrochanteric fractures with a large nail/medullary canal mismatch due to osteoporosis.

19.
Injury ; 52(7): 2010-2015, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33722405

RESUMEN

An entry point medial to the tip of the greater trochanter is considered optimal for antegrade femur nailing. The deforming forces in a subtrochanteric fracture often make it difficult to establish a perfect entry point during antegrade cephalomedullary nailing. To overcome this problem, we report a simple technique of making a retrograde entry portal for select difficult subtrochanteric fractures. The technique was used in 12 subtrochanteric fractures. Our indications were morbid obesity, revision nailing and atypical fractures. The technique involves creating a nail entry portal through the fracture from distal to proximal taking advantage of the abducted proximal fragment. Fracture reduction and nail insertion then proceeds in a standard manner. Additional reaming of the thick endosteal lateral cortex through the fracture was performed in atypical fractures. Satisfactory fracture reduction was achieved in all patients and 11 out of the 12 fractures united in the series. 1 patient developed an infected nonunion and was considered failure of treatment. The retrograde entry portal is a valuable alternative method that can be considered in nailing of difficult subtrochanteric fractures to establish an ideal entry point and nail trajectory.


Asunto(s)
Fracturas del Fémur , Fijación Intramedular de Fracturas , Fracturas de Cadera , Clavos Ortopédicos , Fémur , Fijación Interna de Fracturas , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/cirugía , Humanos
20.
Geriatr Orthop Surg Rehabil ; 12: 2151459321998611, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33717634

RESUMEN

INTRODUCTION: The failure rate of operations involving the cephalomedullary nail technique for unstable femoral trochanteric fractures is 3-12%. Changing the reduction strategy may improve the stability. This study aimed to confirm whether reducing the proximal fragment with the medial calcar contact, as opposed to utilizing an intramedullary reduction, would improve the stability of such fractures. MATERIALS AND METHODS: The unstable femoral trochanteric fracture model was created with fixation by cephalomedullary nails in 22 imitation bones. The 2 reduction patterns were as follows: one was with the proximal head-neck fragment external to the distal bone in the frontal plane and anterior in the sagittal plane as "Extramedullary," while the other was the opposite reduction position, that is, bone in the frontal plane and sagittal plane as "Intramedullary." We evaluated the tip-apex distance, compression stiffness, change in femoral neck-shaft angle, amount of blade telescoping, and diameter of the distal screw hole after the compression test. Statistical analysis was conducted using the Mann-Whitney U test. RESULTS: No significant differences were seen in compression stiffness (p = 0.804) and femoral neck-shaft angle change (p = 0.644). Although the "Extramedullary" tip-apex distance was larger than the "Intramedullary" distance (p = 0.001), it indicated clinically acceptable lengths. The amount of blade telescoping and the distal screw hole diameter were significantly larger in "Intramedullary" than in "Extramedullary" (p < 0.001, p = 0.019, respectively). Our results showed that "Intramedullary" had significantly larger blade telescoping and distal screw hole diameters than "Extramedullary," and contrary to our hypothesis, no significant differences were seen in compression stiffness and femoral neck-shaft angle change. CONCLUSIONS: As opposed to the "Intramedullary" reduction pattern, the biomechanical properties of the "Extramedullary" reduction pattern improved stability during testing and decreased sliding.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA